Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹39.8 L+₹94,370 (2.43%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹44.5 L+₹5.7 L (14.7%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹44.6 L+₹5.7 L (14.8%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical UE Firm and EMD not submitted |
Tender Value
₹48.0 L
EMD Value
₹95,900
Closing Date
7 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINT OF EXHAUST AND VENTILATION SYSTEM AND CONNECTED WORK SUCH AS FILTER MOTOR STARTER WITH CONTROL ETC UNDER AGE EM II IN GE C KIRKEE
2020_MES_358215_3
8366/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹95,900
Yes
22 Oct 2020
17 Aug 2020
8 Sept 2020
17 Aug 2020
7 Sept 2020
25 Aug 2020
17 Aug 2020 - 24 Aug 2020
60 days
Amount
Repair/Maintenance and servicing of electrically operated exhausters, fresh air blower, Air Curtains and Centrifugal fans by dismantling motor, blowers/exhausters and Impeller blades and cleaning the blower chambers by scrubing it with wire brush and removing Dust, black smoke etc and again cleaning the blower chamber with CTC solvent and refixing the blower and motor and balancing the shaft and Impeller complete of following capacities.
Capacity upto 2000M3/hr
Capacity above 2000M3/hr to 5000 M3/hr
Capacity above 5000M3/hr to 10,000 M3/hr
Capacity above 10,000 M3/hr to 20,000 M3/hr
Capacity above 20,000 M3/hr to 40,000 M3/hr
Capacity above 40,000 M3/hr to 60,000 M3/hr
Capacity above 60,000 M3/hr to 1,00,000 M3/hr
Capacity above1,00,000 M3/hr to 1,50,000 M3/hr
Centrifugal fan of capacity 4725cfm. Note- (i) The rate quoted by the contractor include cost of grease, cotton waste, lugs, nut-bolts & washers etc. (ii) Cleaning of Blowers and plant room is deemed to be included in the cost.
Matertial and Labour for double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal with lifting handle, Box/flanged type, aluminium spacer etc, incl taking down old filter all as specified by engr-in-charge of size 610x610x150mm.
All as per item no 2 but of size (630x500x50)mm
All as per item no 2 but of size (610x610x50)mm
All as per item no 2 but of size (630x400x50)mm
All as per item no 2 but of size (610x610x200)mm
S & F of filter "HEPA' with fibre glass paper filtering media capacited 1000 CFM efficiency 99.97% down to particle size of 0.3 micron aluminium frames box type of size 610 x 610 x 300mm incl taking down old filter all as specified & directed by Eng - in - charge
M & L for Washing the unservicable filter of any size for reuse after cleaning with wire brush of High pressure water jet complete all as specified by Engr-in-charge.
Material and Labour for Mild Steel brackets, frames ,supports and stands of type as required made out of angle iron, flat or strip of grade Fe-410-S of any size as per site requirement etc complete with painting two coat with synthetic enemel paint over a coat of red oxide all as specified and as directed by Engr-in-charge.
Supply and fixing of water proof canvas cloth thickness not less than 01mm, cut into required shape and stiched all ends as per required size at site and fixed to exhausters/blowers by means of MS strip/FI clamps, nut bolts and wahers etc including dismantling the existing unserviceable canvas cloth complete all as directed by Engr-in-charge. NOTE : Measurement of finished canvas sheet shall only considered for payment. MS strip/FI clamp, nut bolts etc shall be measured and paid in quoted rate of this item.
Supply and fixing of grooved pulley made out of cast iron, machine finishing suitable for 'V' belt and fixing to shaft of motor or blower by using new shaft key to match with existing including dismantling/removing the existing U/S pully all as directed by Engr-in-charge.
PCD - 118. 2 grooves, Section 'A'
PCD - 200, 2 grooves, Section 'A'
PCD - 140, 3 grooves, Section 'B'
PCD - 140, 4 grooves, Section 'B'
PCD - 200, 4 grooves, Section 'B'
Supply and fixing of HRC fuses,HN type of following capacities :-
Supply and fixing of HRC fuses, cylindrical fuse links type HF of following capacities :-
Supply and fixing of 'V' Belt including removing complete of following sizes all as directed by Engr-in-charge.
Supply and fixing of following ball/roller/tappered bearing suitable for electric motor and blower/exhauster including removing of existing unserviceable bearing of any type or make all as directed by Engr-in-charge.
Disconnecting the electric supply from electric motor, 3 phase, opening the nut bolts from its foundation and removing the burnt electric motor from its foundation and transporting to workshop for repair/rewinding. Dismanlting the motor carefully, taking out rotor assembly and removing the burnt winding from stator, cleaning the stator slots complete by CTC. Rewinding the stator with 'H' class super enameled copper wire of same gauge and varnishing, heating/drying complete. Balancing rotor assembly if required. assemble the motor and complete and transporting back to site and making all connections and testing complete and painting as per existing paint two coat all as directed by Engr-in-charge for following capacities :-
Upto 01 HP Electric induction motor
Above 01 HP up to 02 HP Electric induction motor
Above 02 HP up to 05 HP Electric induction motor
Above 05 HP up to 10 HP Electric induction motor
ditto but of capacity 15 HP Electric induction motor
ditto but of capacity 30 HP Electric induction motor
ditto but of capacity 75 HP Electric induction motor
Supply and fixing of bimetal over load relays with single phasing protection , relay range 9-15 A including removing of old un-serviceable overload relay all as directed by Engr-in-charge
All as per item no 17 but relay range 14-23A.
All as per item no 17 but relay range 20-33A.
Supply and fixing of Power contactor rating 25 Amp, AC-3, rating 415v including removing of old unserviceable power contactor all as directed by Engr-in-charge.
All as per item no 20 but rating 32 Amp
All as per item no 20 but rating 40 Amp
All as per item no 20 but rating 70 Amp
Supply and fixing of MCCB, TP, 400 Amps ,35 KA, ICS=ICU, 415 volt, 50 Hz including removing of old un-serviceable MCCB all as directed by Engr-in-chage.
All as per item no 24 but 250 amps, 35KA
All as per item no 24 but 125 amps, 25 KA
All as per item no 24 but 100 Amps, 25KA
All as per item no 24 but 63 Amps, 25KA
Supply and fixing of MCB, TPN, 40 to 63 Amps ,10 KA,C curve, 415 volt, 50 Hz including removing of old un-serviceable MCB all as directed by Engr-in-charge.
Supply and fixing of MCB, TP, 40 to 63 Amps ,10 KA,C curve, 415 volt, 50 Hz including removing of old un-serviceable MCB all as directed by Engr-in-charge.
Supply and fixing of MCB, SP, 06 to 32 Amps ,10 KA,C curve, 215 volt, 50 Hz including removing of old un-serviceable MCB all as directed by Engr-in-charge.
M & L for Servicing/Cleaning of Air compressor of model KES -75-10.5 of make Kirloskar of capacity 10.5kg/cum by dismantling top cover, fan with fan motor and cleaning the Air filter assy, Oil filter assy Greasing the motor and cleaning the total structure of compressor and control panel with air wash Changing the compressor oil complete and refixing the fan, frill & top cover testing commissioning complete all as directed by Engr-in-charge Note :- (i) The sevicing is to be done by the company manufacturer/OEM . (ii) The compressor oil to be changed will be measured under relevent item.
Supply and fixing of Pre air filter of capacity 500cfm for air compressor of capacity 12cum/min type KPF 600. all as specified and directed. Make - Kirloskar
Supply and fixing of Oil filter for Air compressor with cat part no 274.01.459.50 Make - Kirloskar
Supply and fixing of Air filter for Air compressor with cat part no 270.00.551.50 Make - Kirloskar
M & L for compressor oil suitable for air compressor of type KES - 75-10.5 and taking out old compressor oil, cleaning the oil filter all as directed by Engr-in-charge.
M & L for Cleaning of Damper chambers of exhaust pipe of various beds of Engine test House including removing of all carbon particles, smoke, dust, etc., cleaning of all side walls, supporting beams, pipe supports, brackets complete including removal of existing paint and painting with two coats of synthetic enamel paint over a coat of red oxide primer using spray gun all as specified and as directed.
Taking down carefuly worn out asbestos rope of exhaust pipe at any height complete all as specified and as directed by Engr-in-Charge
Supply & Fixing of Asbestos rope of size 19 mm dia spiral winding (turn by turn) to Engine exhaust pipe at any height, without keeping any gap, duly applying anticorrosive adhesive solution on pipe to avoid heat dissipation suitable for 1200°C working Temp complete all as specified and as directed.
Cleaning and Painting of GI/MS pipes of Air distribution of size 100 / 80 mm dia along with side supports complete with two coats of synthetic enamel paint as per existing colour code all as directed by Engr-in-Charge. Note :- Painting of pipe shall be caried out at hight of up to 10 mtr on wall or air.
Dismantling existing control & power wiring of LT starter Panel of blower motor capcity 15 HP to 75 HP & rewiring with PVC insulated copper wire 4 Sq/6 Sq mm for control & 10/16 Sq. mm for power wiring for proper sequential working of contactors with delay timer, over load relay of Motors, mccb etc. by making proper connections to contactors, relays, fuses, switches, voltmeter,ammter incl testing commissioning complete as directed Note:- (i) Cost of electric cable, lugs & connectors is included in above cost. (ii) The quoted rate include the cost of painting of the panel with two coats of paints complete all as up to satisfection of Engr-in-charge.
Supply, fabricate and errect PGI air duct made out of 20 gauge PGI sheet with necessary suport, jointing with MS angle/flat iron/MS strip etc, cut in to shape, drilled and counter sunk for screw including bending and welding, riveting and painting two coat of existing paint etc, complete and rubber packing suitable size fixed with necessary nut bolts and washers etc. incl taking down old PGI sheet complete all as directed by Engr-in-charge. Note : (i) MS angel iron, flat iron etc shall be measured and paid separately (ii) Neccessary welding and fabrication work to be done at actual site as per existing.
Supply, fabricate and errect PGI air duct made out of 24 gauge PGI sheet with necessary suport, jointing with MS angle/flat iron/MS strip etc, cut in to shape, drilled and counter sunk for screw including bending and welding, riveting and painting two coat of existing paint etc, complete and rubber packing suitable size fixed with necessary nut bolts and washers etc. incl taking down old PGI sheet complete all as directed by Engr-in-charge. Note : (i) MS angel iron, flat iron etc shall be measured and paid separately (ii) Neccessary welding and fabrication work to be done at actual site as per existing.
M/S. OM ENTERPRISES
PAMS ENTERPRISES
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .