Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.1 LAccepted-AOC | 1 | Accepted-AOC Due to L-1 and credit | |
| 2 | 2₹10.4 L+₹1.4 L (15.6%)Rejected-Finance FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹10.8 L+₹1.8 L (20.5%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹12.9 L+₹3.9 L (43.1%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹13.9 L+₹4.9 L (54.1%)Rejected-Finance H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 5 | Rejected-Finance Being other than L-1 |
| Sl No | Description | Qty | Unit | Ganga Enterprises L2 | Balaji Associate L4 | H.S.Kochhar n Sons L5 | BUILDTECH ASSOCIATES L1 | MUKTA AND COMPANY L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Preventing maintenance / attending complaints of both the indoor/outdoor units of Tower type A/C/ Spilts AC/ Window Type AC/Refrigerator/Water Coolers/desert Coolers of any capacity of any make checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc in if necessary replacement of existing size magnetic contactor, relay over load protector, relay, thermostat and internal wirring and service complete all as directed at site.
Note : (i) Fixing of spares parts such as Compressor, starting capacitor, running capacitor, fan motor, blower motor, copper tubes, PVC pipes etc. if found defective will be measured and paid separately as supply only.
(ii) Charging of gas if required will be paid separately as supply only. | 400 | Each Job | 500 ₹2,00,000 | 150 ₹60,000 | 50 ₹20,000 Lowest | 200 ₹80,000 | 200 ₹80,000 |
| 2.00 | Servicing of both the indoor/outdoor units of Tower type A/C 4.0 TR capacity of any make by cleaning of cooling and condenser coil of indoor & outdoor unit, cleaning filters removing internal dust by using vacuum cleaners, oiling, greasing wherever required, complete all as directed at site. | 12 | Each Job | 1,200 ₹14,400 | 1,100 ₹13,200 | 1,000 ₹12,000 | 300 ₹3,600 Lowest | 400 ₹4,800 |
| 3.00 | All as per item No. 1 above but for 1.5/2.0 TR capacity of spilt/window type AC. | 200 | Each Job | 1,200 ₹2,40,000 | 430 ₹86,000 | 1,000 ₹2,00,000 | 200 ₹40,000 Lowest | 400 ₹80,000 |
| 4.00 | Supply only fins and tube type air cooled condenser suitable for any make split type AC of cap of 1.5/ 2 TR | 5 | Each | 50 ₹250 Lowest | 2,200 ₹11,000 | 100 ₹500 | 3,000 ₹15,000 | 1,000 ₹5,000 |
| 5.00 | Supply only new fan motor for outside condenser unit of split AC of capacity 1.5/ 2 TR/ 54 Watt, 220 V or existing size and testing complete all as directed.
Make- American Universal/Khaitan / Usha or equivalent | 20 | Each | 100 ₹2,000 Lowest | 800 ₹16,000 | 1,000 ₹20,000 | 400 ₹8,000 | 800 ₹16,000 |
| 6.00 | Supply only blower fan motor of spilt type AC 1.5/2 Ton capacity and testing complete all as directed.
Make- American Universal/Khaitan / Usha/ LG/Blue star/Voltas/Hitachi or equivalent | 24 | Each | 100 ₹2,400 Lowest | 850 ₹20,400 | 1,000 ₹24,000 | 400 ₹9,600 | 1,000 ₹24,000 |
| 7.00 | Supply only double shaft of 1/5, 1/7 HP fan motor of window type AC 1.5/2 Ton capacity and testing complete all as directed.
Make- American Universal/Khaitan / Usha/ LG/Blue star/Voltas/Hitachi or equivalent | 20 | Each | 100 ₹2,000 Lowest | 1,000 ₹20,000 | 1,500 ₹30,000 | 400 ₹8,000 | 1,000 ₹20,000 |
| 8.00 | Supply only copper refrigerant pipe one run1/4/1/2 Inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as directed.
Note One Run of 1/4 inches dia pipe with insulation will be measured as one RM. | 60 | RM | 50 ₹3,000 Lowest | 200 ₹12,000 | 50 ₹3,000 Lowest | 180 ₹10,800 | 100 ₹6,000 |
| 9.00 | Supply only copper refrigerant pipe one run 5/8 inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as directed
Note:- One Run of 5/8 inches dia pipe with insulation will be measured as one RM. | 50 | RM | 50 ₹2,500 Lowest | 220 ₹11,000 | 75 ₹3,750 | 270 ₹13,500 | 80 ₹4,000 |
| 10.00 | Supply only copper/brass valve 1/4/1/2inches dia, inculding suitable size of pipe, with cap, dead nuts etc for fixing of suction line/delivery spilt type AC outdoor unit complete all as directed. | 20 | Each | 100 ₹2,000 Lowest | 210 ₹4,200 | 125 ₹2,500 | 200 ₹4,000 | 300 ₹6,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
13 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adm Area Agra
GE (AF) Adm Area Agra UP 282008
REPAIR MAINTENANCE OF SUMMER COOLING APPLIANCES AND OTHER CONNECTED WORK UNDER GE (AF) ADM AREA AGRA.
2025_MES_721332_1
8000-2267/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE AF Adm Area Agra
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE AF Adm Area Agra
₹30,000
Yes
6 Oct 2025
18 Jul 2025
15 Aug 2025
18 Jul 2025
13 Aug 2025
1 Aug 2025
Amount
Preventing maintenance / attending complaints of both the indoor/outdoor units of Tower type A/C/ Spilts AC/ Window Type AC/Refrigerator/Water Coolers/desert Coolers of any capacity of any make checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc in if necessary replacement of existing size magnetic contactor, relay over load protector, relay, thermostat and internal wirring and service complete all as directed at site. Note : (i) Fixing of spares parts such as Compressor, starting capacitor, running capacitor, fan motor, blower motor, copper tubes, PVC pipes etc. if found defective will be measured and paid separately as supply only. (ii) Charging of gas if required will be paid separately as supply only.
Servicing of both the indoor/outdoor units of Tower type A/C 4.0 TR capacity of any make by cleaning of cooling and condenser coil of indoor & outdoor unit, cleaning filters removing internal dust by using vacuum cleaners, oiling, greasing wherever required, complete all as directed at site.
All as per item No. 1 above but for 1.5/2.0 TR capacity of spilt/window type AC.
Supply only fins and tube type air cooled condenser suitable for any make split type AC of cap of 1.5/ 2 TR
Supply only new fan motor for outside condenser unit of split AC of capacity 1.5/ 2 TR/ 54 Watt, 220 V or existing size and testing complete all as directed. Make- American Universal/Khaitan / Usha or equivalent
Supply only blower fan motor of spilt type AC 1.5/2 Ton capacity and testing complete all as directed. Make- American Universal/Khaitan / Usha/ LG/Blue star/Voltas/Hitachi or equivalent
Supply only double shaft of 1/5, 1/7 HP fan motor of window type AC 1.5/2 Ton capacity and testing complete all as directed. Make- American Universal/Khaitan / Usha/ LG/Blue star/Voltas/Hitachi or equivalent
Supply only copper refrigerant pipe one run1/4/1/2 Inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as directed. Note One Run of 1/4 inches dia pipe with insulation will be measured as one RM.
Supply only copper refrigerant pipe one run 5/8 inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as directed Note:- One Run of 5/8 inches dia pipe with insulation will be measured as one RM.
Supply only copper/brass valve 1/4/1/2inches dia, inculding suitable size of pipe, with cap, dead nuts etc for fixing of suction line/delivery spilt type AC outdoor unit complete all as directed.
Supply only copper/brass valve 5/8 inches dia, inculding suitable size of pipe, with cap, dead nuts for fixing of suction line/delivery spilt type AC outdoor unit complete all as directed.
Supply only PVC drain water pipe dia heavy duty transparent flexible for drainage water system of split AC complete with clamp fitting and drilling all as per ground requirement and as directed.
Supply only complete indoor/out door PCB of spilt type AC/window type AC of Cap 1.5TR/2 TR with remote assembly with suitable battery for any type & make of Split/window AC.
Supply only complete indoor /out dooor PCB of invertor type spilt type AC/window type AC of Cap 1.5TR/2 TR with remote assembly with suitable battery for any type & make of Split/window AC.
Supply only running oil capacitor combined of Cap 50/6, 55/4, 60/4, suitable for 1.5 TR/2 TR split/ window AC at site and making connection using PVC insulated copper wire and thimbles complete all as directed. Make-Tesla/Asian/ Keltron/Sarada/Unistar.
Supply only starting dry capacitor combined of Cap 80/100, 100/120 MFD suitable for 1.5 TR/2 TR split/ window AC at site and making connection using PVC insulated copper wire and thimbles complete all as directed. Make-Tesla/Asian/ Keltron/Sarada/Unistar.
Supply only and taking out unserviceable compressor sealed unit of 1.5 TR capacity, reciprocating/Rotary from the spilt type AC (Make : LG/Blue star/Voltas/Hitachi etc.) single phase 230 volts and replacing the same with new compressor sealed unit fixing and vacuumization pressure testing leakage rectification and charging refrigerant gas and testing complete. Note :- Compressor supplied shall be of same make as of existing make.
All as per item No. 17 above but for 2.0 TR capacity.
All as per item No. 17 above but for 1.5TR/2.0 TR capacity of Window type.
Supply only spilt type indoor unit complete of existing cap/make including removing and refixing the same place complete all as specified and as directed.
Supply only in replacement of existing cap/make/type spilt type outdoor unit body complete including heating coil, Motor, compressor with Gas of existing cap/make complete all as specified and as directed
Taking down 1.5/2.0 ton capacity split type AC complete with indoor unit, outdoor unit and refrigerant pipe and re-fixing the same in other room of same building or another building including testing and commissioning detailed as under :- (a) Cooling unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water including fixing of interconnection pipe all as directed. (b) Erection of condenser, compressor unit on outside of the building, fixed over suitable size of clamp/bracket.(Old clamp/bracket retrieved from demolition shall be reused in case old clamp/bracket found serviceable) (c) All civil work as plastering, cementing, whitewashing, filling of existing hole etc. required to be done as per site requirement at both the places(from where taken down and at place of re-fixing) NOTE:- (i) Charging / toping up gas if required will be measured & paid separately as supply only. (ii) Additional length of copper tubing if required will be measured & paid separately.
Taking down 1.5/2.0 ton capacity Window type AC complete and refixing the same in other room of same building or another building including testing and commissioning detailed as under :- (a) All required requisite work such as cutting/drilling/fixing shall be part of the Job in quoted rate. NOTE:- (i) Charging / toping up gas if required will be measured & paid separately as supply only.
S&F waterproof ply wood 4 mm thick commercial type including cutting, drilling and making good the disturbed surface all as directed.
Supply only metal clamp /bracket for outdoor unit of split type AC 1.5/2.0 ton capacity.
S&F in repairs foam armor of size 5/8" for copper refrigerant pipe of AC complete.
S&F in repairs foam armor of size 1/4" for copper refrigerant pipe of AC complete.
Supply only complete Remote of spilt type AC/window type AC of Cap 1.5TR/2 TR with remote assembly with suitable battery for any type & make of Split/window AC.
M&L for pressure testing of split type AC 1.5/2.0 Ton capacity and rectifying the leakage of refrigerant gas in the system, including vacuuming and charging only gas, replacing the capillary tube and copper liquid filter including testing and commissioning complete. NOTE- Supply only gas will be measured & paid separately.
Servicing of Refrigerator of any capacity and make by cleaning of cooling and condenser coil of checking of refrigerant pressure, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as starting capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as directed ncluding if necessary replacement of minor spare parts i.e thermostate, relays , capactor, contractor etc. Note : (i) Fixing of spares parts such as Compressor, etc if found defective will be measured and paid separately as supply only. (ii) Charging of gas if required will be paid separately as supply only.
Taking out unserviceable compressor sealed unit of refrigerator(make-Whirlpool/Kelvinator/Genius Supreme/LG/Samsung etc) 165 to 210 litres capacity, single phase 230 volts and replacing the same with new compressor sealed unit Fixing & connecting the same including vacuumization, pressure testing leakage rectification and supply charging refrigerant gas and testing complete.
M&L for taking out unserviceable compressor sealed unit of refrigerator(make-Whirlpool/Kelvinator/Genius Supreme/LG/Samsung etc) 280 to 330 litres capacity, single phase 230 volts and replacing the same with new compressor sealed unit Fixing & connecting the same including vacumization, pressure testing leakage rectification and supply charging refrigerant gas and testing complete. Note for item No. 29 & 30:- Compressor supplied shall be of same make as of existing make.
Preventing maintenance/Servicing of Deep Freezer of any capacity and make by cleaning of cooling and condenser coil of checking of refrigerant pressure, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as directed ncluding if necessary replacement of mior spare parts i.e thermostate, relays , capactor etc
Preventing maintenance/Servicing of Water cooler of any capacity and make by cleaning of cooling and condenser coil of checking of refrigerant pressure, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as starting capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as directed including if necessary replacement of mior spare parts i.e thermostate, relays , capactor motor condenser coil etc . Note for (i) Fixing of spares parts such as Compressor, if found defection will be measured and paid separately as supply only. (ii) Charging of gas if required will be paid separately as supply only.
Taking out unserviceable compressor sealed unit of water cooler (Make-Shriram/ Usha/ Blue star) of capacity 40/80/150 liter capacity, single phase 230 volts, & replacing the same with new compressor sealed unit fixing & connecting the same including vacuumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete. NOTE- Compressor supplied shall be of same make as of existing make.
Suuply only gas charging the system with correct quantity of R-32/R-22/R-410/R-407/R-134 gas for split/window type A/C of 1.5 TR/2 TR/3 TR/4 TR capacity/Refrigerator/Deepfreezer/Water cooler and repairing the leakage in tube /lines by brazing and charging the unit with compressor oil charging replacing the capillary tube and copper liquid filter complete including fixing the same in position and testing and commissioning complete all as specified and directed. Note : contractor should be gas deposit the MES store with Gas cylinder.
Repair/Maintenance/Over all servicing of desert cooler including all fitting and fixtures, if required replacement of grass pad set of any size of desert cooler to cover the entire area (one desert cooler consist three grass pad), PVC pipe and distribution cap, with replacement of internal wiring of Cap CC X2.5 Sqmm copper cable, PVC connecting, existing size of clamp, nut bolts, including welding, grinding work etc including painting inner surface with one coat of black bituminous paint and outer surface of with grey/existing colour after preparation of the surface complete all as specified and directed Note : (i) Fixing of spares parts such as Motor, grass, clamp, pump etc if found defection will be measured and paid sperately as supply only.
Supply only suitable size electric fan Exhaust fan motor 1400 rpm, 450 mm swip including Blade, single phase 230 volts for desert cooler/ ductable cooler. Make- Crompton Greaves/Khaitan/Bajaj/Everst or equivalent
Supply only water lift pump (fully submersible) of existing size/capacity/makes for desert cooler. Make- Murfi/Everst/Bunsal/Maxcool or equivalent.
Supply only wood wool pads complete all as directed.
Servicing of heavy duty plastic body ductable Air coolers (Which cools on the principle of water evaporation) having option of air discharge from the top or bottom 200 liters water storage capacity, Axial fan with 1.1 KW, 3 phase, 50Hz Ac motor and 10000 CFM air flow capable to cool 1000 Sqft area with standard height of 10 feet. All sides of cooling cabinet shall be provided with 100 mm thick paper based honeycomb structure cooling media including if necessary replacement of MS Clamp, PVC pipe, float valve, connecion pipe Capacitor, etc complete all as specified and directed. NOTE (i) Fixing of spares parts such as Motor, grass pad, capacitor, submersible pumps , canvas cloths, and internal wiring, clmaps etc if found defective will be measured and paid sperately as supply only.
Supply only PVC water pipe distribution and PVC pipe connection pieces for water distribution for Ductable/disert cooler incl. testing complete all as specified and directed.
Supply only heavy duty motor capacity Axial fan with 1.1 KW, 3 phase, 50Hz Ac for ductable Air coolers including testing and commissioning complete all as specified and directed.
Supply only heavy duty water lifting pump (fully submersible) of existing size/capacity/make of Air Ductable Coolers) including testing and commissioning complete all as specified and directed.
Supply only canvas cotton duck canvas cloth with natural/existing color with existing size/color/make of ductable cooler including fixing arrangements such as nut bolts washers and clamp etc complete all as directed.
Supply only honey comb pad of 100mm size for suitable size of ductable air cooler complete all as directed.
Supply and fixisng of in replacement of 3 Phase starter of Cap 1 HP with single phase preventer and over load protector and 63 Amp MCB of suitable for Ductable cooler complete all as specified and directed.
Disconnection and taking down the fan motor of Ductable cooler and refixing at the same location after rewinding by super enameled copper winding wire with existing size & guage with all insulation material including, varnishing & heating complete of the fan motor of desert cooler all as specified & directed.
S&F in replacement sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth metal plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
To file the complaint on Customer care service Centre (LG/Hitachi/bluestar /Samsung/Lloyd /Daikin etc) of AC/Refrigerator/water Cooler for attending the unserviceable complaint for attending the complaints. If any items are unserviceable which is in under warranty its are replaced by Existing OEM and other items are paid by seperately. Commplaint slip will be recorded.
Supply and Replacement of GI sheet of 22 gauge thick with TDF flange rectangular / square duct made out of 'L' shaped, hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket, strengthening angle iron of suitable size & Length for supporting duct, Canvas, air deliver controlled fins, suitable size of each air deliver duct complete all as specified and directed.( Note: All accessories/material required for proper functioning of duct shall deemed to be included in quoted Rate)
Supply fixingl testing and commissioning of Thermal Insulation 13 mm with Nitrile Rubber with fixing material/chemical of ducatble air cooler duct which is installed single/double story building including provide to suitable size of ladder or fixing arrangement (structure) complete all as specified and directed.
Ganga Enterprises (BID ID -3384512)
MUKTA AND COMPANY (BID ID -3392467)
Balaji Associate (BID ID -3384982)
H.S.Kochhar n Sons (BID ID -3391872)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .