| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.9 L+₹45,347 (1.54%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹29.9 L+₹46,150 (1.57%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹32.9 L+₹3.4 L (11.6%)Rejected-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L4 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BHaratpur
GE BHaratpur
REPAIR/MAINTENANCE OF VARIOUS COMPONENT OF LT OVERHEAD / UG NETWORK SYSTEM AND CONNECTED ITEMS AT 39 FAD UNDER GE BHARATPUR
2020_MES_377326_1
8972/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE BHaratpur
Class D category b(I)
7 documents required · 7 mandatory
₹500
Yes
GE BHaratpur
₹60,000
Yes
19 Oct 2020
14 Sept 2020
12 Oct 2020
14 Sept 2020
10 Oct 2020
27 Sept 2020
60 days
Amount
M&L for attending, repair and rectification of external LT/HT electric supply compliants on 1100 Volts grade, under ground / over head system alongwith necessary T & P, safety devices as per site requirement for the following type of compliants complete all as specified and directed:- (a) Replacement of wornout jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Disconnecting cable from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Notes:- (i) LT Jointing kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the Pole coping and inserting the cable along with protection pipes.
Disconnecting faulty LT cables from MCCB/MCB of LT Panel/DB box , cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables replacement of warn out aluminium lugs including crimping with crimping tools and cable gland from under ground loop line and rejoining the same to restore electric supply. Notes:- (i) Aluminium lugs if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive pattiy item such as insulation tap . (iii) Earth work for loop opening and returniing filling will be included in the quotated rate
S&F in repairs, LT overhead line PVC separator with accessories viz clamps, screws and locking arrangement for fixing on four conductors system (for 4 wire) complete all as specified and directed.
S&F in repairs, LT overhead line PVC separator with accessories viz clamps, screws and locking arrangement for fixing on two conductors system (for 2 wire) complete all as specified and directed.
Supply only Alluminium ligs of following sizes :- (a) 10 sqmm
Supply only pin type reducer Alluminium lugs of following sizes: (a) 10 sqmm
Supply only cable gland Double Compression Armoured Weather Brass Cable Glands for following sizes: (a) Overall diameter 23mm to 26 mm
Overall diameter 30mm to 33mm
Overall diameter 37 mm to 41 mm
Overall diameter 46 mm to 52 mm
Overall diameter 61 mm to 66 mm
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified and as directed by Engineer-in-Charge. (Taking out old brick from trenches shall be measured separately and deduction for brick shall be made on this account).
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L Protection to cable with one layer of bricks laid flat abutting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks, complete all as specified and as directed by Engineer-in-Charge.
M&L Un washed machine sand as cushioning of under ground cable (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) and punned after laying complete all as specified and as directed by Engineer-in-Charge. Note: Only punned thickness will be measured
Taking out old un-servicable/ faulty PVC armoured LT under ground cable of any size any core complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C1 using 20mm grade stone aggregate in copping including necessary form work complete all as specified.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
S&F and laying Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts grade of cross-sectional area 150 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.)
Ditto all as per Srl item No 17 here in before but size of cable 120 x 3.5 core
Ditto all as per Srl item No 17 here in before but size of cable 95 x 3.5 core
Ditto all as per Srl item No 17 here in before but size of cable 50 x 3.5 core
Ditto all as per Srl item No 17 here in before but size of cable 35 x 3.5 core
Ditto all as per Srl item No 17 here in before but size of cable 16 x 4 core
M&L stay assembly complete set of size 16mm rod with accessories as shown electrical plate No.1, incl loop type insulator stay clamp etc all as specified and directed by Engineer in Charge.
Supplied and fixed in repair loop type insulator porcelain vitreous white, brown or green with overall dimensions of 90 x 140 mm, clearance of hole 25.5 mm for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner
Supplied and fixed in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia. for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner
S&F in repair for shackle type, vitreous, white, brown, or green insulators, including galvanised mild steel strips, washers, insulators bolts, washers and nut for working pressure 1100 Volt, 100mm height 115mm dia, glavanised steel fitting strips of size 21 x 5mm, 14mm dia bolts complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner ceramics/ Mysore.
S&F Off- load changeover switch in sheet metal enlosure with front handle operating system, powder coated, factory made of capacity 200 Amps, 4 pole with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- C&S Cat No: CSCSOF200CO4 or equivalent make in Havells/Legrand/IndoAsian.
Supply only PVC insulated multi stranded Aluminium conductor twin core of size 10 Sqmm complete all as specified and as directed by engineer in Charge
S&F cable PVC insulated aluminium conductor of size 6 sqmm, Two core, cut to length all as required at site with thimbles of appropriate size, drawn into conduit/pipe fixed to wall or pole for connection of energy meters to DB etc complete all as specified and as directed by engineer in Charge
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed by engineer in Charge
Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 120 KVARs and up to12 stages installed at various locations including carrying out complete maintenance/repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/MCCBs for isolation (with all the accessoires) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed. Notes:-(i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, replacement of defective control wiring, small part such as Push button, lugs any auxilary contatct,auto selctor switch etc and necessary servicing repair by expert technician and register will be maintaned for the same.(iii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/MCCB and fixing/installing/testing and commissioning the complete system. (iii) capacitors bank, APFC relay, power contactor, control CT, MCBs/MCCB shall be measured and paid saperatly
Supply only power factor correction capacitor, 5 KVAR, ultra heavy duty oil filled 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed. Make: L&T in cat No:LTBCU or equivalent makes mention in Appx B
Ditto all as per item No 32 above but 10 KVAR Capactor Bank. Make: L&T in cat No:LTBCU
S&F APFC relay suitable for existing panel upto 12 stage, including taking down old unserviceable one complete all as specified and directed. Make: L&T Modeel No:etaCON L12/Schneider/HPL/Indo Asian or equvivalent.
S&F in repairs, capacitor duty contactor, type MOC built in auxillary contact blocks, 8.5 KVAR, 415 volts, 3 phase, 50 Hz, type MO C8.5 complete all as specified and directed. Make: L&T/ IndoAsian/Standard/HPL.
Diitto all as per item No 37 above but capacitor duty contactor, type MO C12.5 complete all as specified and directed. Make: L&T/ IndoAsian/Standard/HPL.
S&F power contactor heavy duty, 3 pole, 40 Amps with 2 No + 2NC, type ML3 including taking down old unserviceable one complete all as specified and directed. Make:- L&T Cat No SS90721 or equivalent make in IndoAsian /Standard/HPL.
M&L for Aluminum Conductor Steel Reinforced (ACSR) conductor of LT OH line including straightening and stringing of any size and pattern as required at site including jointing the conductor with new conductor on existing pole and binding with the new aluminium binding wire 2 mm dia inclulding taking down existing old unserviceable conductor complete all as specified and as directed. Notes: (i) Trimming of tree branches upto 1.50 Mtrs distance around conductor is included in the unit rate quoted. (ii) Extra aluminium conductor requiured for jumpers and binding purpose is included in the unit rate quoted.
Trimming/prunning and removing of tree branches or any other forein objects from LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system complete all as specified and directed. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
S&F in replacement MCCB 04 pole 100 Amp, DPX3 160 Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420055 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 04 pole 63 Amp, DPX3 160 Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420053 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 04 pole 200 Amp, DPX3 250 Thermal maganatic, breaking capacity not less than 25 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420218 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 04 pole 250 Amp, DPX3 250 Thermal maganatic, breaking capacity not less than 25 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420219 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 03 pole 160 Amp, DPX3 160 Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420007 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB TPN 63 Amp Thermal maganatic, breaking capacity not less than 16 KA, 415 volts complete all as specified and as directed by Engineer-in-Charge.
S & F or laying galvanixed steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 40mm bore complete all as specified and as directed by Engineer-in-Charge.
S & F or laying galvanixed steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 100mm bore complete all as specified and as directed by Engineer-in-Charge.
M&L earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts check nuts and washers of galvanised iron or steel all as showin in electrical plate No 3 connected to earthing test point all as specified or indicated includig testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of size 6 Sqmm to 16 Sqmm complete all as specified and as directed by Engineer-in-Charge. Make:3 M, Y-Denson or equivalent makes mention in Appx B
Ditto all as per Srl item No 48 here in Before but size 25 Sqmm to 50 Sqmm
Ditto all as per Srl item No 48 here in Before but size 70 Sqmm to 120 Sqmm
Ditto all as per Srl item No 48 here in Before but size 150 Sqmm to 240 Sqmm
M & L Cross arms bracings supports clamp and back plate fabricated from structral steel section including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint
Supply installed testing and comminsioning indoor type , outdoor type,Self standing, double door, front and back openable, APFC panel compartmental type with APFC relay 5 stage with heavy duty MPP capacitor bank 120KVAR ( 10 KVAr - 2Nos, 25KVAr-02 Nos, 50KVAr-01 Nos, with 7% detuned harmonics filter reactor. ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each control and MCCB TPN 250 Amp 36 KA as incomer including control CT & control wiring complete having following assessories including control wiring with HR FRLS copper wire complete all as specified. (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry. (ii) Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Incoming of APFC panel of MCCB TPN 250 Amps, 36 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating. (iv) 120KVAR ( 10 KVAr-02 No, 25KVAr-02 Nos, 50KVAr-01 Nos ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor. (v) High performance microprocessor based 3 phase APFC relay 5 stage with Auto/Manual Option.(vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No). (vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors. (viii) Induced air system provided with axial flow fan/ centrifugal fan.(ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front
Supply, install, testing and commissioning factory made (CPRI test certified) LT cubical panel board 3 Phase 4 wire system outdoor type front and back opening separate compartment for each control gear,cable alley, provision of knock out type plates for various sizes of cable in and out , incoming and outgoing feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15 mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Angle iron frame of 50x50x6mm thick duly painted and embedded in PCC 1:3:6 45 CM below ground level and 15 Cm above ground level and consisting the following: Location S.S No. 2, Outside MT. (a) Incoming MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA : 01 No.(b) Busbar alluminium 500 A capacity .(c) Out Going- MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA :2 Nos. (d) Out Going- MCCB 4 Pole, 415 V, Fixed magnetic type, 125 Amps with breaking capacity 16 KA :1 Nos . (e) Out Going- MCCB 4 Pole, 415 V, Fixed magnetic type, 63 Amps with breaking capacity 16 KA :1 Nos. (f) Indicator lamp and seletor switch = 1 Set . (g) Volt meter 0-500 V Squair type 144x144 mm : 1 Set .(h) Ammeterr 10-200 V Squair type 144x144 mm: 1 Set .Note: space of out going MCCB 1 Nos to be provide and panel mounted on 2' height PCC platform
Scrapping & cleaning old surface of Panel box, painting with synthetic enamelled paint over a coat of primer for size of Panel boxes upto 01 to 04 Sqm area of sheets including angles canopy and legs etc.
M&L for preparation of external surfaces of steel tubular poles / rail / garden poles of any height by rubbing sand paper and cleaning, applying two coats of aluminium paint complete and after that apply 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide all as specified and directed.
Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with 5 Nos terminals of 100 A rating, glands including with flat iron clamps of size 30 x 6mm, nuts and bolts. Make Hansel Cat part No:KF 2525 G or FIBOX(SOLID PC 2528 13G)
S&F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 60 watts with suitable drivers and included 10KV SPD etc and connecting with 4.0 sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall / pole with and including bracket made out of GI pipe of suitable dia light grade not less than 1.5 mtr long, bent to shape, fixed to Pole/Wall in any position with flat iron clamps of size 30 x 6mm including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make:- Crompton Cat Part NoLSTP-60-CDL-Mor equivalent model of Philips/Bajaj/Havells.
S & F in replacement cable copper multi stranded of size 1.5 Sqm 3 core from Junction box to street light fitting complete all as directed by Engineer-in-charge.
Supply, fabricate and Install as in replacement of double sided glow sign board of size 1.5 mtr x 1.2 mtr x 40 cm, made out of 25 mm bore MS pipe 'H' frame, covered with PGI sheet 24SWG gauge on all sides except front side, front side with flex sheet duly digital print embossing as directed by Engineer-in charge showing location /details of power house /tech area as directed and writing of letters (Block, Roman, Italic), in two or three rows, the same letters should be printed on both sides of the sign board, fixed with aluminium equal angle 25 x 25 x 3 mm thick fixed with screws and providing inside LED tube light fittings 1 x 9 Watt - 4 Nos for glowing the sign board at night with necessary internal electrical connections fixed on wall/pole and the sign board shall be fixed with MS channel 40 x 40 x 4 mm thick by means of nuts, bolts and grouted in ground up to 1.5 Mtr above GL and 0.45 belew GL with 50 mm dia GI pipe stand embedded in PCC bed block of size 300x300x450mm with PCC 1:3:6 type C1 using 20 mm graded stone aggregate and the MS frames/pipes shall be given two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe up 100mm dia complete Note :- GI pipe shall be measured and paid in concern Item
Repair and maintenance/serviceing of LT panel having 2 Nos ACBs, including repacement of U/S MCCBs, repacement of incommer bus bas 4Nos capacity 1200 Amp with copper bus bar approx lenght each approx 400mm making shap as required, serviceing and overhauling of ACB 800 Amp including greasing oiling of moveable part, making tripping mechnism serviceable, painting of outdoor surface with approved colour complete Note MCCB will be measured and paid separatly
krishna Associate
S D POWER SOL
Pioneer Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .