Loading…
Loading…
Tender Value
₹51.8 L
EMD Value
₹1.0 L
Closing Date
6 Jun 2026, 11:00 amDue today
Executive Engineer (E)
Executive Engineer (E),PWD NES/M-251, LM Bund Road, Ramesh Park, Delhi
Supplying, Installation, Testing and Commissioning of Lift at FOB Near Shyamlal Collage, G.T. Road, Delhi.
2026_PWD_292351_1
26/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
120 days
N-2533
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.0 L
Yes
30 May 2026
30 May 2026
6 Jun 2026
30 May 2026
6 Jun 2026
30 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Sub Head I | |||||
| 1.1 | Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:-
(i) Speed-1 MPS
(ii) Floors-2 (G+1)
(iii) Travel - 6 to 8 Meters (approx.)
(iv) Stops & opening- 1 stops and 1 openings (All Floor are opening in same side)
(v) Controller: A.C. variable voltage & variable
frequency
(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required.
vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/ without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system
(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.
(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.
....................Cont................................ | - | - | - | - |
| 1.2 | (xi) Type of doors
(a) Car: Power operated, center opening horizontal sliding stainless steel scratch proof
(b) Landing doors: stainless steel scratch proof.
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.
(xiii)Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.
(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload
detection and protection, Overspeed Governer, Dot Matrix LED D &
P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency.
(xvi) An appropriate technological support be provided (Through emergency messaging services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness.
...................Cont............................ | - | - | - | - |
| 1.3 | (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided
(After installation of lift one year is defect liability period & no extra amount will be paid for any kind of repair/maintenance) | - | Each | 0.9 | - |
| 2Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete asrequired:-(i) Speed-1 MPS(ii) Floors-2 (G+1)(iii) Travel - 6 to 8 Meters (approx.)(iv) Stops & opening- 1 stops and 1 openings (Ground Floor & First Floor are opening opposite side)(v) Controller: A.C. variable voltage & variablefrequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/ without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors ..................Cont........................ | |||||
| 2.1 | (a) Car: Power operated, center opening horizontal sliding stainless steel scratch proof.
(b) Landing doors: stainless steel scratch proof .
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.
(xiii)Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.
(xiv) Closed loop Control System, protection against power fluctuation, self-diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency.
(xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness.
(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided
(After installation of lift one year is defect liability period & no extra amount will be paid for any kind of repair/maintenance) | - | Each | 0.19 | - |
| 3Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | |||||
| 4Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | |||||
| 5Supplying and laying of following PVC insulated and PVC sheathed /XPLE armounrd Aluminum Conductor power cable of 1.1 KV grade of following size in the existing RCC/ HUME METAL/PVC pipe as required. | |||||
| 5.1 | 4 X 10 Sq. mm armounrd Aluminum conductor power cable | - | Mtr | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.31 MB
BOQ_388279.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid