Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹6.2 L+₹2,363 (0.38%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹6.3 L+₹16,205 (2.63%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹8.7 L+₹2.5 L (40.4%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
12 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AJIT KUMAR DWIVEDI
AGE I AF SINGARSI
Repair Maintenance of DG Sets of under Different capacities at AF Stn Singarsi under AGE I AF Singarsi
2022_MES_557631_1
C/8575/E8
Open Tender
Civil Works
Item Rate
270 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹16,000
Yes
19 Nov 2022
14 Oct 2022
14 Nov 2022
14 Oct 2022
12 Nov 2022
28 Oct 2022
60 days
Amount
Comprehensive maintenance including periodical servicing & regular inspection of 400 KVA /320 KVA DG Sets (Make :(i) KOEL (ii) Cotton Greaves(iii) Kirloskar, Location : Sub Stn -05, Booster) by the authorised technician / service engineer of OEM or their authorised service dealer, checking the mechanical and electrical healthyness of the diesel engine and alternator, routine servicing of the DG set including cleaning & replacement of air filter, changing of fuel filter and lubracating oil filter,draining out unserviceable engine oil from engine and refill with new engine oil, cleaning all sludge/deposits in the oil sump and removed off the site as per schedule, minor adjustment of control parameters, tracing out the defects and replacement of defective spares including taking out the old unserviceable one to keep the DG set healthy and serviceable state as specified and directed by Engr-in-charge at site. Notes :- (a) Spares , engine oil will be measured and paid separastely as applicable. (a) Apart from these routine servicings, major repair/replacement if any as decided by Engr-in-Charge will be measured and paid separately available within the scope of this schedule.
Supply only "O" ring for turbo outlet
Supply only Engine Control Panel with EMS unit for 400 KVA DG Set.
Supply only Jupiter T-Bolt clamp S/F 83 mm O.D. same as per existing of 400 KVA
Supply only lubricating oil pressure sender VDO,Make : same as per existing of 400 KVA
Supply only Preline filter (without water level sensor), As per Existing of 400 KVA
Supply only Schwitzer Turbo master (Turbo charger) (S 200/80H27BECRM/74DA7-0.85A/R-VTE), As per Existing 400 KVA DG sets
Supply only Flange for turbocharger oil drain,Make : same as per existing of 400/320 KVA
Supply only Belt 'V' section (Ax56),Make : As per Existing of 400/320 KVA
Supply only Fuel filter assembly (Consisting of fuel filter & mounting bracket) of 400 /320KVA
Supply only Air filter cleaner primary element for 400 KVA DG set, As per existing DGs
Supply only Air filter cleaner safety element for 400 KVA DG set, As per existing DGs
Supply only lubricating Oil filter for 400 KVA DG set, As per existing DGs
Supply only Diesel Oil filter for 400 KVA DG set, As per existing DGs
Supply only assemble of Stop solenoid for 400 KVA DG set,existing make of DG set.
Supply only 'V' Belt suitable for 400 KVA DG Set same as per existing
Supply only Thermostat element for 400 KVA DG Set, existing make
Supply only AVR suitable for KOEL Alternator Model of 400/320 KVA DG set
Supply only Fuel pipe for 400/320 KVA DG set as per sample.
Supply only Rubber coupling for 400 /320 KVA DG set as per sample.
Supply only Digital Ammeter for 400 /320 KVA DG set
Supply only indicator light for 400 /320 KVA DG set
Supply only Digital Voltmeter for 400 /320 KVA DG set
Supply only Radiator cap for 400 /320 KVA DG set
Supply only door locks suitable for 400 /320 KVA DG set
All as per item No 01 here-in-before but capacity 160 KVAs DG Set (Make : KOEL, Location : Booster & DAM Pump House)
Supply only Engine Control Panel with EMS unit for 160 KVA DG Set.
Supply only Fuel filter pre for 160 KVA DG set, Make : KOEL
Supply only Diesel filter micro for 160 KVA DG set, Make : KOEL
Supply only Fuel pipe for 160 KVA DG set as per sample.
Supply only 'V' Belt suitable for 160 KVA DG Set same as per existing
Supply only assemble of Stop solenoid for 160 KVA DG set,existing make of DG set Make : KOEL
Supply only Relay board for 160 KVA DG set,existing make of DG set Make : KOEL
Supply only AVR suitable for Kirloskar Alternator of 160 KVA DG set
Supply only Thermostat element for 160 KVA DG set for Kirloskar Green, Make : ISI marked.
Supply only lubricating oil pressure (LOP) Sender for 160 KVA DG set, Make : KOEL
Supply only indicator light for 160 KVA DG set as per sample.(Make:L&T/Siemens/GE)
Supply only Digital Ammeter for 160 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Digital Voltmeter for 160 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Radiator cap for 160 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Rubber coupling for 160 KVA DG set as per sample.
All as per item No 01 here-in-before but capacity 62.5 KVA DG Set (Make : KOEL, Location : Pump House No-04)
Supply only Fuel filter pre for 62.5 KVA DG set, Make : KOEL
Supply only Diesel filter micro for 62.5 KVA DG set, Make : KOEL
Supply only 'V' Belt suitable for 62.5 KVA DG Set same as per existing
Supply only Fuel pipe for 62.5 KVA DG set as per sample.
Supply only Rubber coupling for 62.5 KVA DG set as per sample.
Supply only indicator light for 62.5 KVA DG set as per sample.(Make:L&T/Siemens/GE)
Supply only Digital Ammeter for 62.50 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Digital Voltmeter for 62.50 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Radiator cap for 62.50 KVA DG set as per sample.(Make:L&T/Havells/AE)
All as per item No 01 here-in-before but capacity 30 KVA DG Set (Make : Ashok Leylend, Location : SAG Pakur)
Supply only 'V' Belt suitable for 30 KVA DG Set same as per existing
Supply only Fuel Filter for 30 KVA Ashok Layland DG Set.
Supply only Diesel Oil Filter element set for 30 KVA Ashok Layland DG Set.
Supply only Air Cleaner element set for 30 KVA Ashok Layland DG Set.
Supply only Fuel pipe for 30 KVA DG set as per sample.
Supply only Rubber coupling for 30 KVA DG set as per sample.
Supply only indicator light for 30 KVA DG set as per sample.(Make:L&T/Siemens/GE)
Supply only Digital Ammeter for 30 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Digital Voltmeter for 30 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Radiator cap for 30 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Engine Oil, 15W 40, Make : Castrol/Speed/HP/Shell/Viscol/Veedol.
Supply only Engine Oil, 20W 40 Make : Castrol/Speed/HP/Shell/Viscol/Veedol.
Supply only Coolant for radiator Castrol/Speed/HP/Shell/Veedol.
Supply only Battery 12 volts 180 AH heavy duty suitable for DG Set operation. Make: Exide or equivalent as approved.
Taking down the radiator of 400 KVA DG Sets from engine, transportation to the workshop, dismantling the radiator, repairing of top and bottom tank including necessary welding / brazing & making the radiator leak proof, cleaning the complete radiator internally with chemical agent (K Clean) and outside with Kerosene oil and high pressure water jet,filling of coolant including replacement of defective copper core, suction connection, main pipe, stud, stay, spacer, rubber hose (02 Nos) and assembling the radiator including replacement of all old rusted mild steel nuts, bolts washers & gasket sets and hose pipe asembly including transportation from wksp to original work site & fixing to the engine and testing complete.(Coolant for radiator will be measurd and paid separately)
Taking out self starter up to 24 volt from the 400 / 320/160/KVA DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt coil, segrigation of serviceable parts for re-use, rewinding of coil with existing size of copper wire. Reassembling the same with replacement of of carbon brush 01 set, Beadix pinion 01 no, Half clutch assy 01 No, Field coil 01 No, solonoid switch 01 No., commutator 01 nos, fixing the self starter on the engine at site and testing complete all as directed by Engr-in-Charge.
Taking out self starter 12 volt from the 62.5 KVA / 30 KVA DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt coil, segrigation of serviceable parts for re-use, rewinding of coil with existing size of copper wire. Reassembling the same with replacement of of carbon brush 01 set, Beadix pinion 01 no, Half clutch assy 01 No, Field coil 01 No, solonoid switch 01 No., commutator 01 nos, fixing the self starter on the engine at site and testing complete all as directed by Engr-in-Charge.
Taking out turbocharger L/R from the 400 KVA DG Set, transportation to work shop for repair and dismantling the same, cleaning and carrying out thorough inspection of each components/spares segrigation of u/s & serviceable spares for reuse and decarbonising machine, cutting, grinding polishing etc and re-assembling of the turbocharger by replacement of turbocharger shaft, turbocharger kit and connected spare parts to match with the existing , refixing and testing as directed at site by Engineer in Charge.
All as per item No 12 here-in-before but capacity 160 KVA DG Set
Supply and laying in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor (multistranded), 150 Sqmm 3.5 core , 1100 volts grade connected with suitable cable gland and copper lugs of any size laid in trenches or passing through pipes including testing after laying, including taking up old UNSV cable complete of following size all as specified and directed by Engineer-in-Charge. Make : Universal/Plaza/Gloster/Havells/Nicco/CCI.
Supply and fixing Euroload Change over switch 400 Amps rated capacity ,FN- TPN in SS enclosure , mounting on wall /Panel , including cable interlock top & bottom,cofirming to IEC 60947-3, IS/IEC 60947-3 of 50 Hz, 415 Volt as per following amps rated capacitycomplete with cable connection of existing DG set and Transformer as directed by Engr-in Charge . Make- L&T Cat part No. SK90491 or equiavelent
Supply and fixing in replacement of PVC single core 25 sqmm FRLS PVC insulated copper conductor , Make : Havells /Polycab/Anchor or equiavalent
Supply only Copper lugs of size 35/50/70/95 mm
Supply only copper Battery terminal complete with nut , bolt and washer for fixing to existing batteries .
M&L for applying two coats of synthetic enamel spray painting to conopy diffirent capacity DG Sets of existing colour shade on surfaces of any description, exc. 10cm with or girth to external surface of DG sets by spray gun after necessary preparation of old surfaces complete all as specified and as directed by Engr-in-Charge. (Note:- Shade of paint to be approved by AGE(I).
M/S SINGH ENTERPRISE
M/S MBS TRADING CO
DANATION CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .