Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹31.8 L+₹76,180.30 (2.46%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹32.9 L+₹1.9 L (6.19%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹33.0 L+₹2.0 L (6.43%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹33.4 L+₹2.4 L (7.87%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹42.3 L
EMD Value
₹84,680
Closing Date
5 Apr 2024, 6:00 pmClosed
MAJ VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
SPECIAL REPAIR OF BLDG NO P-23 (REPAIR BAY) IN R/O 944 LT AD REGT WKSP (COMP) AT KANPUR CANTT UNDER GE (I) KANPUR
2024_MES_646471_1
GE(I)/KAN/T-93 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹84,680
Yes
29 Jun 2024
14 Mar 2024
12 Apr 2024
14 Mar 2024
5 Apr 2024
29 Mar 2024
Amount
Dismantling of asbestos cement (Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern gates, roof coverings, etc complete all as specified and directed.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
All as per item No 4.00 above but except sheeting on doors (any thickness) fixing only complete all as specified and directed.
Dismantling boarding , any description , fixed in any position with screws complete all as specified and directed.
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595mm of approved texture with Semi perforated 12mm thick micro tegular edged GRG false ceiling tiles, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15 x 32 mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing, complete all as specified and directed.
Taking down cement plaster from brick wall including racking out joints, hacking for key & scrubbing down with water where existing complete all as specified and directed.
Demolition of brick work built in cement mortar complete all as specified and as directed .
M&L Brick work with sub class “B” brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:6 comlete all as specified and as directed.
All as per item No 10.00 above but except bricks complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surface using WPC @ 3% by weight of cement or as per manufacturers instruction finished even and fair without using extra cement complete all as specified and directed. (WPC to be measured separatly).
M&L for 15 mm thick rendering in cement mortar 1:6 on other than fair faces of concrete or brick, finished even and fair without using extra cement complete all as specified and directed.
Supply only water proofing compound, ISI marked complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including cornices plaster etc and applying two coat oil bound distemper of any colour on over a coat of primer over applying a coat of wall care putty on wall including rubbing with sand paper to achieve a smooth surface and sharp straight edges etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint (any Colour ) over a coat alkali?resistant priming paint complete all as specified and directed.
M/L for Preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spots etc and applying one coat of cement paint (any colour ) on wall with brush complete all as specified and as directed.
M/L for Preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spots etc and applying one coat of oil bound distemper (any Colour ) on wall with brush complete all as specified and as directed.
M/L for preparation of old painted surfaces of wood and wood based materials of any description not other wise described over 10 Cm width or girth and applying one coat of Synthetic Enamel paint (any colour )complete all as specified and as directed.
All as per item No 19.00 above but on old steel surfaces complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for Complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 290 Gde E-165 complete all as specified and directed.
All as per item No 22.00 above but fabrication & fixing only complete all as specified and directed.
S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
M&L for preparation of new steel surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat zink chrome red oxide primer complete all as specified and directed.
Hacking out old broken glasses of any description from metal frames including punching or drilling out old glazing pins/springs clips and fixing new ones complete all as specified and directed.
S&F sheet glass 3mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 sq. mtr in each pane complete all as specified and directed.
S & fixed in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Taking down and Refixing window shutters in same opening after easing and readjusting exc 1sqm and not exc.2 sqm complete all as specified and directed.
Demolition of concrete in ground floors and paving n exc. 15cm thickness (below or above ground level) un-reinforced concrete & removal of rubbish beyond defense land complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection & finishing surface even and smooth with using extra cement complete all as specified and directed.
M&L providing PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in, cement concrete in roof kerbs or mud stops, copings, rounded or chamfered on edges complete all as specified and directed.
M & L for 40mm thick PCC 1:2:4 type BO (using 12.5mm graded stone aggregate) as in floor finishing surface even and smooth with using extra cement complete all as specified and directed.
M&L 38mm width glass dividing strips, 3 mm thick and inserted in position, conform to design complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L Non- skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L Glazed ceramic Coloured tiles in vertical surface like skirting, dado complete 350x250mmx7mm/ 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10 mm thick rendering in cm 1:4 complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and directed.
Point wiring for one light/fan/bell/exhaust fan point/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size not less than 20mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed by Engr in Charge & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per srl item No 39.00 above but upto ceiling height and on surface at ceiling complete all as specified and directed.
All as per srl item No 39.00 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl PVC conduit complete all as specified and directed.
All as per srl item No 39.00 above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed.
All as per srl item 39.00 above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts complete all as specified and directed.
Switch piano flush button single pole one way 15/16 amps 230 Volts complete all as specified and directed.
M&L for socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
S & F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed.
S&F in replacement of wall mounted LED light fittings 22 watt, 6500K, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically complete all as specified and directed.
Supply and fix in replacement of 80 watt High efficiency round high bay luminaire with aluminium die cast housing with high lumen efficacy of 110 lm/W complete all as specified and directed.
S & F VTPN distribution board iron clad, double door with IP-54 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to complete with one MCCB 3 pole 415 Volts 125 Amps, 4 pole rating with rupturing cap 26 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 2.5 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 1.5 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 30 to 63 amps,with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
M&L for MCB single pole 240 volts 5 to 30 amps, 'C' curve with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
Disconnecting & taking down upto 1400m sweep ceiling fan anddeposited to MES store yard and Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%,with remote for speed control and all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete all as specified and directed. Note : (a) Make, Model & Colour of fan as approved by GE. (b) Writing MES No. in black synthetic enamel paint by the contractor. (c) T & P will be provided by the contractor for reaching any height of the ceiling.
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion complete all as specified and directed.
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor 10 sq. mm nominal cross section twin core for service connections complete all as specified and directed.
Disconnecting electrically and taking out old unserviceable LT UG cables any type of size upto 50 Sqmm 3.5 core complete all as specified and directed.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables complete all as specified and directed.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed.
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.
PRATAPGARH CONSTRUCTION CO.
Ashirwad Contractor and Supplier
M/s DKS Engineering Works
Khalil Ahmed and Sons
JOG CONSTRUCTION
M/S SDS Construction Co.
Khushi Muskan Engineer & Developer
ESKEY COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .