Loading…
Loading…
Tender Value
₹65.3 Cr
EMD Value
₹1.3 Cr
Closing Date
28 Jul 2026, 12:00 pm
Construction of Road Over Bridge, Approach Road, Quarters etc. in connection of Nimpura Reception Yard-Kharagpur 3rd line work under jurisdiction of Dy CE/Con/II/Kharagpur, S. E. Railway, Kharagpur.
4640-GRC-CE-C-SO-23-2026
4640-GRC-CE-C-SO-23-2026
Open
18 Months
Dholpur, Rajasthan
₹0
₹1.3 Cr
30 Jun 2026
30 Jun 2026
14 Jul 2026
A-Execution of all work as per schedule 3269992.63 Below/P
B-Execution of all work as per schedule 345758846.33 Below/P
C-Execution of all work as per schedule 75913.84 Below/P
D-Execution of all work as per schedule 220176766.13 Below/P
E-Execution of all work as per schedule 44312036.24 Below/P
F-Execution of all work as per schedule 779531.65 Below/P
G-Execution of all work as per schedule 1079992.95 Below/P
H-Execution of all work as per schedule 7930022.00 Below/P
I-Execution of all work as per schedule 8906441.00 Below/P
J-Execution of all work as per schedule 2827500.00 Below/P
K-Execution of all work as per schedule 12220553.00 Below/P
L-Execution of all work as per schedule 2138650.00 Below/P
M-Execution of all work as per schedule 1899949.73 Below/P
N-Execution of all work as per schedule 1207472.00 Below/P
O-Execution of all work as per schedule 481587.50 Below/P
Item Breakup - A-Execution of all work as per schedule
Using Soil Class SQ2 Providing portable fencing along running track where work is to be done in close vicinity of track, maintaining during execution of work and removing after completion of the work as per direction of the Engineer. Fencing shall consist of self supporting steel angles of size 50mm x 50mm x 6mm, 1.5m long provided with hooks etc. and embedded in CC 1:2:4 block of size 0.23m x 0.23m x 0.23m placed at c/c distance of 2m along track. 12mm dia rods in three horizontal layers shall be tack welded with angle p o s t s . Note : Released material will be property of the contractor after completion of work. Cost of cement required for CC blocks shall be paid separately. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
With provision of one 50mm Metre wide retro-reflective tape in horizontal direction, duly secured/tight with vertical posts.
Supplying, erecting in all types of soils, hard wood pile 5m to 7m long without joint, 125mm average dia. for protection of bank slope including two coats of coal tar paint complete, as directed. Note: Payment will be made as per actual driven length of pile.
Driving rails 90R/52 Kg Metre section below average ground level within the slope/toe of embankment including making of nose with contractor's own arrangement complete in all respect Note: Payment will be made as per actual driven length of rail which will be supplied free by Railways at the site of work.
Shoring with 'Z' section MS Sqm sheet piles side by side in all kinds of soil mechanically or manually as per approved drawing with contractor's own arrangement complete in all respects and removal of sheet piles after completion of the work as directed by engineer in-charge Note: Payment will be made as per actual driven length of pile. Total 2988478.00
Item Breakup - B-Execution of all work as per schedule
20m to 30m SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
30m to 40m Drilling of NX size borehole (75mm dia.) in all types of hard rock and collection of rock core samples from boreholes and preserving in boxes.
20m to 30m Conducting in-situ full size Plate Load Test (PLT) at selected location as per IS:1888 including making loading arrangements & casting of RCC/cast in-situ concrete footing as per codal provisions including excavation and refilling of trial pit.
Plate size 30cm x 30cm
Plate size 45cm x 45cm
Plate size 60cm x 60cm
Taking out 100mm dia. & Each 450mm long undisturbed samples of soil from bore holes, including provision of air tight containers for packing and, labeling incl. transporting the samples to laboratory. Piston sampler shall be used for extracting undisturbed samples where necessary. Samples shall be collected as per IS:2720.
Taking out 100mm dia. & Each 450mm long disturbed samples of soil from bore holes, including provision of air tight containers for packing, labeling and transporting the samples to laboratory. Samples shall be collected as per IS:2720.
Conducting penetration test as per IS:2131 at approximate1.5m intervals in bore holes, as directed by the Engineer in charge
Collection of water samples Each at required intervals Conducting laboratory Tests on collected soil samples as per relevant IS code
Moisture Density
Atterberg Limits
Specific Gravity
Grain size analysis including Each Hydrometer analysis
Direct Shear Test
Natural Density
Consolidation Test SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Tri-axial Test Conducting Laboratory tests on collected ROCK SAMPLES as per relevant IS code
Water Absorption & Porosity Each
Point Load Test
Modulus of Elasticity
Abrasion Testing
C o n d u c t i n g chemical Each analysis of soil samples to d e t e r m i n e aggressiveness in relation to attack on concrete / reinforcement including determination of pH value Earthwork in excavation by mechanical means (Hydraulic Excavator)/Manual Means for foundations and floors of the bridges, retaining walls etc. including setting out, dressing of sides, ramming of bottom, getting out the excavated material, back filling in layers with approved material and consolidation of the layers by ramming and watering etc. including all lift, disposal of surplus soil up to a lead of 300m, all types of shoring and strutting with all labour and material complete as per drawing and technical specification as directed by Engineer in charge. Note: This item will be used for excavation work in connection with other miscellaneous works also like side drains, foundation for OHE masts and other miscellaneous structures in connection with Gauge Conversion, Doubling, New lines.
All kinds of soils
Soft rock blasting)
Hard prohibited ) SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Providing and laying in position Plain cement concrete of specified Nominal Mix for miscellaneous works like side drains, foundation for OHE masts and other miscellaneous structures excluding the cost of C e m e n t , centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse cum sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1:3:6 (1 Cement : 3 coarse cum sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
P r o v i d i n g and laying in cum position machine batched, machine mixed and machine vibrated Cement Concrete of specified grade as per approved Design Mix (mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved plants) using 20mm graded crushed stone aggregate and coarse sand of approved quality in RCC raft foundation & Pile cap including finishing, using Plasticiser in approved proportions (as per IS:9103), to modify workability without impairing strength and durability complete as per specifications and direction of the Engineer in charge. N o t e : 1. Payment for cement, reinforcement and shuttering shall be made extra under relevant item. 2. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons for not using plasticiser at the stage of Mix Design and in that case deduction shall be made as per relevant item. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY P r o v i d i n g and laying in position machine batched, machine mixed and machine vibrated Cement Concrete of specified grade as per approved Design Mix (mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved plants) using 20mm graded crushed stone aggregate and coarse sand of approved quality for the following Reinforced cement concrete structural elements up to height of 9.0 m from foundation top level, including finishing, using Plasticiser in approved proportions (as per IS:9103), to modify workability without impairing strength and durability complete as per specifications and direction of the Engineer in charge. N o t e : 1. Payment for cement, reinforcement and shuttering shall be made extra under relevant item. 2. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons for not using plasticiser at the stage of Mix Design and in that case deduction shall be made as per relevant item.
Abutment & Pier
Wing wall and Return wall
Abutment cap, Pier Cap, cum Inspection Platform & Pedestal over Pier cap, Fender wall, Diaphragm wall etc.
Approach slab at formation cum level, Dirt wall/ ballast wall at formation level
Extra for every increase of cum 1m or part thereof in the height above 9.0 m
Providing and fixing Weep Metre Holes in Abutments, Wing walls and Return walls etc., of new bridges with 110mm dia UPVC pipe Type A ISI marked with all contractor's men, material, transportation, all taxes as per specifications and as directed by Engineer-in- Charge. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Boring, providing and installation of bored cast in- situ Reinforced Cement Concrete piles using Hydraulic piling Rig of specified diameter and length below pile cap of specified grade with Design Mix Cement Concrete, using 20mm graded crushed stone aggregate and coarse sand of approved quality, to carry a safe working load not less than specified, concreting by machine batching, machine mixing, scaffolding, using Admixture in approved proportion (as per IS:9103), placing with tremie pipe, chipping off of pile top to remove laitance concrete above cut off level etc., pumping and bailing out water complete in all r e s p e c t as per approved drawing, specification and direction of the Engineer in charge. N o t e : 1. Payment for only cement, reinforcement shall be made extra. 2. Length of the pile for payment shall be measured up to the bottom of RCC pile Cap. 3. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons for not using plasticiser at the stage of Mix Design and in that case deduction shall be made as per relevant item.
1200mm diameter
Providing, fabricating and MT installing permanent casing pipe for bored piles for all diameters with specified thickness of steel plate including all labour, materials, tools & complete as per approved drawing & specifications complete in all respect as per the direction of Engineer in charge. Note: Payment shall be made as per the weight of circular plate of casing pipe only. E x t r a for chiselling in addition to boring of piles, if chiselling is required to be resorted to in hard rock or big stone boulders larger than 30cm, manually or by any other means. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
1200mm diameter pile Conducting load test of a single pile up to specified capacity in accordance with IS:2911 (Part-IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. with all labour, material, tool & plants, equipment, machinery, etc. complete as per drawing and specification, as directed by the Engineer.
Initial load test above 100 Each ton and up to 250 T capacity pile
Extra for every increase of Each 50 ton in pile capacity or part thereof over 250 ton
Routine Load Test above Each 100 ton capacity up to 250 ton capacity pile Lateral load testing of single pile in accordance with "IS Code of practice IS:2911 (Part-IV) for determining safe allowable lateral load of pile" with all labour, material, tool & plants, equipment, machinery, etc complete as per drawing and specification as directed by the Engineer.
Piles capacity of up to 50 ton
Piles capacity of above 50 ton and up to 100 ton
Pulse Echo Test (PET) for Each integrity testing of piles with contractor's men, materials and machines. The rate includes cost of Inspection of site, preparation of pile head and any other unforeseen cost required for the test, submission of reports in triplicate as per satisfaction of the Engineer in Charge.
Providing and applying two Sqm coats of coal tar or bitumen confirming to IS:3117- latest version on the top and sides of RCC box/slabs @ 1.70 kg/sqm after cleaning the surface with all labour and materials complete job as directed by the Engineer. Centering and shuttering including strutting, propping etc. and removal of form for : SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
All types of bridge sub- Sqm structures, e.g. pier, abutment, wing wall, retaining wall, RCC box type foundations, Abutment cap, Pier Cap, Inspection Platform & Pedestal over Pier cap, Fender wall, Diaphragm wall etc. up to 5m above ground level
All types of bridge super- Sqm structures, e.g. slabs, I- girders, T-girders, Box girders etc. up to 5m above ground level.
Extra for additional height Sqm over item no. 025031 & 025032 wherever required with adequate bracing, propping etc. over initial height of 5 metres for every additional height of 1 metre or part thereof. Supply and using Cement at Worksite
Ordinary Portland Cement MT 53 grade of approved brands/makes
Pozzolana Portland Cement MT approved brands/makes Supply of steel reinforcement of approved brands/makes for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Thermo-Mechanically Treated bars of grade Fe- 500D or more of approved brands/makes.
Making suitable designed cum staging for cast in-situ PSC girders/slabs up to 10.5m height from bed level up to soffit of girder/slab with all contractors materials, machinery, tools and plants, transportation complete in all respects required for casting and removal of the same after completing the work and restoring the site to original. Note: The payment for staging shall be made on the cubical quantity of concrete of main Girders/slabs. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Design, supplying and fixing in Centimetre position elastomeric bearing true to line and level conforming to IS:3400, IS:226, BS-5400 under prestressed concrete girders/ Steel Girders, for Pre-cast as well as cast-in- situ girders as per approved drawing. The rate shall include cost of load test of one no. bearing from Railway approved firms and all fixing materials, equipments, machineries, labour, taxes, loading, unloading, leading, lifting etc. complete. Rates include getting the drawing approved from Railway and cost of inspection during manufacturing from railway approved organization.Note : 1. The rate is for finished item complete and paid only after fixing in position below the girder. 2. The volume shall be as given in the drawing and no deduction shall be made for inserted steel plates etc. Providing and fixing in position of standard preformed sealed and slab type or strip seal elastomeric type expansion joints for Railway bridge or Road Over Bridges as per approved drawings and latest MORTH/IRC specifications complete in all respect as directed by Engineer in-charge.
For 40mm expansion
For 80mm expansion Load testing of one or more spans of bridge as selected by the Engineer as per approved load test procedure following relevant IS/IRC/Railway codes with contractor's labour, deflection measuring instruments, loading materials, recording and analyzing the load testing results including all lead & lift, etc. complete as required. The rates are all inclusive and will be paid after load test is finished and girder is cleared of the kentledges/loading material etc. The load shall be 1.25 times the stipulated design load.
For Span design load up to Each 100 MT SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Extra for every increase of 1 MT MT or part thereof over 100 MT in the span design load capacity up to 800 MT Providing and fixing in position GI Drainage Spouts of required length with Grating in RCC slab and filling bitumen along kerb as shown in drawing with contractor's pipes, bitumen, tools, equipment, lead, lifts etc. complete as per specifications and as directed by Engineer in- charge.
50mm dia. Drainage Spouts Metre
Supplying 160mm dia. PVC Pipes Class-I, capable for a pressure of 2.5 kg/sqm in footpath of ROB for laying cable with all contractor's materials labour, tools, plant, machinery, vehicles, consumables, lead, lift etc. complete as per specifications and as directed by Engineer in- charge. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Supplying, fabrication, assembling of all types of steel girders of specified spans with structural steel conforming to Quality "B0" Grade Designation E250 conforming to IS:2062, erection / slewing / end launching of steel girders with cranes or any other approved launching methods as per site c o n d i t i o n s (not requiring traffic block) on sub- structure including provision of trolley refuges etc., complete as per approved Q A P and drawings conforming to IRS-B1-2001 and other relevant codes and specifications. Note: 1. Detailed fabrication and erection drawings & launching methodology will be prepared by the contractor and got approved from Railway. 2. The rate is all inclusive including launching in position, complete in all respect except cost of (i) Painting / Metalising; (ii) Bearings & (iii) HSFG bolts which shall be paid extra under relevant item. 3. The payment shall be made on the theoretical weight of main components and gusset plates only. 4. Payment Schedule: (i) Receipt of material at site: 40% (ii) Fabrication of girders: 20% (iii) Erection/Launching: 20% (iv) Completion in all respects: 20%
Plate Girder/Semi Through MT Girder/Composite Girder (Steel Work)
Supplying and fixing HSFG Kg bolts of any dia and any length with suitable nuts including DTI washers conforming to IRS-B1-2001 f o r bridges and steel structures with contractors labour, tools and plants and lead and lift etc., complete. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Assembling and erection of fabricated Steel girders on bearings at site with crane/derrick / any other approved means at site on sub structure with labour, equipment, T&P including site bolting with all temporary arrangements, scaffolding etc. with contractors design and scheme for longitudinal launching/side slewing (not requiring traffic block) approved by Railway. Rate includes drifts, service bolts, Holding down bolts etc. as per drawings. Note: Payment for HSFG bolts used if any will be made separately under relevant item.
Plate Girder/Semi Through MT Girder /Composite Girder more than 12.2 m span Metallizing of steel work of girders with sprayed aluminium after surface preparation by Sand/grit blasting, followed by one coat of etch primer (IS:5666) & one coat of Zinc Chrome primer (IS:104) and two coats of aluminium paint (IS:2339) with all labour, T&P and material as a complete job duly conforming to all relevant specifications and process given under Clause 39 of IRS-B1-2001. Note: Nominal Thickness of sprayed Aluminium coating shall be 150 microns. DFT of Zinc chrome primer shall be 25- 30 microns and DFT of each coat of Aluminium paint shall be 12-14 microns.
Providing and fixing railing Kg used in rows for footpath or anti-crash barrier railing with B class G.I. pipe 65/50 mm nominal dia including cost of M.S. angle and channels in vertical posts, welding / bolting, priming painting with one coat ready mix Zinc Chromate conforming to IS:104 with DFT of 25-30Microns, followed by one coat of Zinc Chrome red oxide conforming to IS:2074 with DFT of 25 Microns with all material, labour, T&P as a complete job. Note: Cost of painting shall be paid extra under relevant item. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Providing and fixing various size HTS holding down bolts conforming to relevant Codes/Specification in concrete column or in other structures with proper nuts, bolts, washers/plates, grouting of holes with cement or epoxy concrete with all material, labour, T&P as a complete job.
With Cement Grout. Cost of Kg cement shall be paid extra.
Supplying, Fabricating and MT fixing access ladders, inspection platforms, Trolley r e f u g e s etc., on bridges with structural steel conforming to IS:2062 including welding / bolting, priming painting with one coat of ready mixed paint of Zinc Chromate (IS:104) with DFT of 25-30 microns followed by one coat of Zinc Chrome Red Oxide (IS:2074) with DFT of 25 microns with all material, labour, T&P as a complete job. Note: Painting shall be paid separately under relevant item. Design, supply, fitting and fixing in position true to line and level POT-PTFE bearing of 300MT Capacity, consisting of a metal piston supported by a disc or un reinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be of cast steel / fabricated structural steel, metal and elastomer elements complete as per IS:2062, IS:1030, AISI:304, AISI:316, IS:6911, BS:3784, IS:3400, IS:226, BS-5400, Bridge Code and as per approved drawing and Technical Specifications. The design of the bearings shall be submitted by the manufacturers / contractor and got approved from Railway before fixing. Test report after inspection of the bearings shall be submitted and got approved before the materials are lifted from the manufacturer premises.
POT-cum (Free end)
POT Bearing-Fixed Type SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
POT-cum (L)Bearing
POT-cum (T)Bearing
Supplying of stone boulders cum weighing not less than 35 kg each at specified bridge locations.
Manufacture and supplying Sqm Galvanized Wire Net Trungers made from 4mm galvanised steel wire @ 32 kg/10sqm having minimum tensile strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into mesh with double twist, mesh size not exceeding 100mm x 100mm.
Providing 300mm thick (average) Dry Stone flooring with boulders of not less than 35kg each in weight, hand packed with surface levelled off to the correct section with hammer dressing as necessary on the ground including filling the gaps with quarry spalls and ordinary sand complete including cost of supply of all materials, labour, lead, lift, tools, plants, crossing of tracks and the like as per drawing and technical specification as directed by Engineer in charge.
Supply and laying of quarry cum dust including consolidation, supply of all materials, labour, lead, lift, tools, plants, crossing of tracks as per drawing and technical specification as directed by the Engineer in charge in case loose slush is encountered at site of foundation before casting the foundation or laying the filtering media.
Supply and laying of coarse cum sand including consolidation with all labour, lead, lift, tools, plants, crossing of tracks as per drawing and technical specification as directed by the Engineer in charge in case loose slush is encountered at site of foundation before casting the foundation or laying the filtering media. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Providing and fixing of Metre Drainage Spouts of 110mm UPVC Type A ISI marked (Working pressure 4 kg/sqcm) using suitable clamps and adhesive etc., complete.
Providing and laying of filter cum media consisting of granular materials of GW, GP, SW groups as per IS:1498 (latest) in required profile behind boulder filling of abutments, wing walls / return walls etc. above bed level with all labour and material complete job as per drawing and technical specification of RDSO Guidelines.
Supplying, spreading and cum filling coarse sand (no cohesive materials to be used) of approved quality including watering and ramming in foundation, behind the abutment, wing wall, retaining wall in layers not exceeding 150mm thick including its compaction as per direction of Engineer-in- charge. The rate includes all lead, lift, ascent, descent, crossing of Railway line etc. complete with contractor's labour, materials, tools and plant.
Providing Boulder Backing cum behind wing wall, return wall, retaining wall with hand packed boulders & cobbles with smaller size boulders toward the back including all lead, lift, labour & other incidental charges as complete work in all respect. Payment for boulder/cobbles will be done extra. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Earthwork in excavation by mechanical means (Hydraulic Excavator)/Manual Means for foundations and floors of the bridges, retaining walls etc. including setting out, dressing of sides, ramming of bottom, getting out the excavated material, back filling in layers with approved material and consolidation of the layers by ramming and watering etc. including all lift, disposal of surplus soil up to a lead of 300m, all types of shoring and strutting with all labour and material complete as per drawing and technical specification as directed by Engineer in charge. Note: This item will be used for excavation work in connection with other miscellaneous works also like side drains, foundation for OHE masts and other miscellaneous structures in connection with Gauge Conversion, Doubling, New lines. 90 022011(022020) Extra over item nos. cum 160.00 41.13 6580.80 022011 to 022014 for executing the work under water and/or liquid mud to compensate all additional arrangements including pumping out water as required. Note: The extra percentage rate is applicable only for the quantity of work executed under water. [RATE = 20%] Total 333454379.72
Item Breakup - C-Execution of all work as per schedule
For one shift ( 12 Hrs)
For Half Shift (4 hours)
Fabrication, supplying and Each fixing 600mm x 450mm Bridge Board made from 16 SWG MS Sheet duly welded or riveted to back support of two 600mm long horizontal angles of size 25mm x 25mm x 3mm & two numbers 2.5 metre long vertical support of MS Angle of size 50mm x 50mm x 5mm, welded / rivetted to board. Vertical supports shall have split ends for proper fixing in ground. Vertical supports of board shall be embedded in ground in M 20 Cement Concrete blocks of size 300mm x 300mm x 300mm, complete job including painting & writing of subject matter on bridge board, as directed by Engineer - In charge Note: Excavation & concrete work will be paid separately. Total 70031.22
Item Breakup - D-Execution of all work as per schedule
concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. Providing and fixing PTMT towel rail complete with brackets fixed to wooden 17.73 cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.2 600 mm long towel rail with Each 50 708.95 35447.5 total length of 645 mm, 150 width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 18.0 WATER SUPPLY 18.4S PP-R PIPES SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including 18.4 all PP - R plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of E n g i n e e r- i n - C h a r g e . ( Internal Exposed on walls ) 18.4.1 PN - 16 Pipe, 20mm OD Metre 300 272 81600 151 (SDR-7.4) 18.4.4 PN - 16 Pipe, 40mm OD Metre 300 545.75 163725 152 (SDR-7.4) Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings and fixing 18.5 the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in- C h a r g e . Concealed work, including cutting chases and making good the wall etc. 18.5.1 PN - 16 Pipe, 20mm OD Metre 400 477.85 191140 153 (SDR-7.4) 18.5.2 PN - 16 Pipe, 25mm OD Metre 300 515.2 154560 154 (SDR-7.4) 18.5.3 PN - 16 Pipe, 32mm OD Metre 400 561.45 224580 155 (SDR-7.4) Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & 18.6 cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in- Charge. External work 18.6.1 PN - 16 Pipe, 20mm OD Metre 300 224.95 67485 156 (SDR-7.4) 18.6.2 PN - 16 Pipe, 25 mm OD Metre 200 265.05 53010 157 (SDR-7.4) SER-CONST-HQ-ENGG/SOUTH EASTERN RLY 18.6.3 PN - 16 Pipe, 32 mm OD Metre 200 316.25 63250 158 (SDR-7.4) 18.6.4 PN - 16 Pipe, 40 mm OD Metre 200 415.1 83020 159 (SDR-7.4) 18.6.5 PN - 10 Pipe, 50 mm OD Metre 200 450.95 90190 160 (SDR-11) Providing and fixing PPR 18.6A Unions 161 18.6A.1 PPR Union 20mm Each 100 315.5 31550 162 18.6A.2 PPR Union 25mm Each 100 334 33400 163 18.6A.3 PPR Union 32mm Each 100 403.7 40370 164 18.6A.4 PPR Union 40mm Each 100 543.1 54310 165 18.6A.5 PPR Union 50mm Each 100 782.1 78210 18.7S C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & 18.8 fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 166 18.8.1 15 mm nominal dia Pipes Metre 300 497.8 149340 167 18.8.2 20 mm nominal dia Pipes Metre 300 537.6 161280 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This 18.9 includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 168 18.9.3 25 mm nominal dia Pipes Metre 300 355.4 106620 169 18.9.4 32 mm nominal dia Pipes Metre 300 438.6 131580 170 18.9.6 50 mm nominal dia Pipes Metre 300 794.25 238275 18.15S BRASS FITTINGS Providing and fixing brass 18.15 bib cock of approved quality : 171 18.15.1 15 mm nominal bore Each 200 353.25 70650 Providing and fixing brass 18.16 stop cock of approved quality : 172 18.16.1 15 mm nominal bore Each 90 353.25 31792.5 SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Providing and fixing gun metal gate valve with C.I. 18.17 wheel of approved quality (screwed end) : 173 18.17.1 25 mm nominal bore Each 50 622.4 31120 Providing and fixing C.P. 18.22 brass shower rose with 15 or 20 mm inlet 174 18.22.2 150 mm diameter Each 50 222.35 11117.5 C.I. SLUICE VALVES/ FIRE 18.31S HYDRANTS & FIXTURES 18.48A Providing and fixing Per Litre 24000 11 264000 rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in- 175 charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support including fittings & fixtures for tank shall be paid separately. 18.49S C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved 18.49 quality conforming to IS:8931 : 176 18.49.1 15 mm nominal bore Each 60 506.8 30408 Providing and fixing C.P. brass long nose bib cock of approved quality 18.50 conforming to IS standards and weighing not less than 810 gms. 177 18.50.1 15 mm nominal bore Each 50 820.7 41035 Providing and fixing C.P. brass stop cock (concealed) 18.52 of standard design and of approved make conforming to IS:8931. 178 18.52.1 15 mm nominal bore Each 80 670.45 53636 Providing and fixing C.P. brass angle valve for basin 18.53 mixer and geyser points of approved quality conforming to IS:8931 179 18.53.1 15mm nominal bore Each 80 574.3 45944 18.54S PTMT FITTINGS Providing and fixing PTMT 18.54 bib cock of approved quality and colour. 18.54.2 15 mm nominal bore, 122 Each 30 161.2 4836 180 mm long, weighing not less than 99 gms AIR VALVE & WATER METER 18.59S (BULK TYPE) Providing and fixing C.I. double acting air valve of approved quality with bolts, 18.59 nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : SER-CONST-HQ-ENGG/SOUTH EASTERN RLY 181 18.59.3 100 mm dia Each 20 8893 177860 18.65 Providing and fixing PTMT Each 80 111.45 8916 soap Dish Holder having length of 138mm, breadth 182 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. Providing and fixing PTMT extension nipple for water 18.75 tank pipe, fittings of approved quality and colour. 18.75.1 15 mm nominal bore, Each 60 53.6 3216 183 weighing not less than 32 gms 18.77 Cutting holes up to 15x15 Each 120 452 54240 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. 184 with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard 18.90 with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90 degree 185 18.90.1 For 15.88mm outer dia pipe Each 120 99.6 11952 18.90.2 For 22.22 mm outer dia Each 120 113.8 13656 186 pipe 18.90.3 For 28.58 mm outer dia Each 120 163.6 19632 187 pipe 18.90.4 For 34.00 mm outer dia Each 120 204.85 24582 188 pipe 18.90.5 For 42.70 mm outer dia Each 120 221.95 26634 189 pipe 18.90.6 For 48.60 mm outer dia Each 120 273.15 32778 190 pipe 19.0 DRAINAGE STONE WARE PIPES AND 19.1S FITTINGS Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm 19.2 nominal size) all-round S.W. pipes including bed concrete as per standard design : 191 19.2.1 100 mm diameter S.W. pipe Metre 200 964.75 192950 SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Providing and laying non- pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff 19.6 mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 192 19.6.2 150 mm dia. R.C.C. pipe Metre 300 556.45 166935 193 19.6.4 300 mm dia. R.C.C. pipe Metre 500 994.3 497150 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside 19.7 plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal 19.7.2 diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 19.7.2.1 With common burnt clay Each 60 26405.5 1584330 194 F.P.S. (non modular) bricks of class designation 7.5 Providing and fixing in position pre-cast R.C.C. 19.19 manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 19.19.1.1 Rectangular shape 600x450 Each 30 1437.65 43129.5 195 mm internal dimensions Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with 19.32 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay Each 20 26861.9 537238 196 F.P.S. (non modular) bricks of class designation 7.5 SER-CONST-HQ-ENGG/SOUTH EASTERN RLY 21.0 ALUMINIUM WORK 21.1S General Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ 21.1 neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer- in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.2 Powder coated aluminium Kg 300 530.9 159270 197 (minimum thickness of powder coating 50 micron) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing 21.1.2 of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.1 Anodised aluminium Kg 500 598.6 299300 (anodised transparent or dyed to required shade 198 according to IS: 1868, Minimum anodic coating of grade AC 15) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket 21.3 etc. complete as per the architectural drawings and the directions of engineer- in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.2 With float glass panes of 5 Sqm 300 1505.25 451575 199 mm thickness (weight not less than 12.50 kg/sqm) SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon 21.8 sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. 21.8.1 Upto 5mm depth and 5 mm Metre 2400 96.75 232200 200 width 21.13 Providing and fixing Brass Each 200 528.85 105770 100mm mortice latch and lock with 6 levers without pair of handles (best make 201 of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 22.0 WATER PROOFING 22.1S General 22.5 Providing and laying water Sqm 500 617.05 308525 proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure 202 for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY 22.22A Providing and applying fibre Sqm 1000 563.1 563100 reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self- priming of elastomeric water proofing liquid (dilution with water in the ratio of 3:1) and two coats 203 of undiluted elastomeric water proofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. RAIN WATER HARVESTING & 23.0 TUBEWELLS 23.1S General Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 23.4 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in- charge. 204 23.4.3 200 mm nominal size dia Metre 400 1255.7 502280 23.5 Supplying, filling, spreading cum 200 1509.8 301960 & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required 205 thickness, for all leads & lifts, all complete as per direction of Engineer-in- charge. 23.6 Supplying, filling, spreading cum 200 1538.25 307650 & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the 206 existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in- charge. 23.7 Supplying, filling, spreading cum 200 1538.25 307650 & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required 207 thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. NEW TECHNOLOGIES AND 26.0 MATERIALS SER-CONST-HQ-ENGG/SOUTH EASTERN RLY PREFAB/PRECAST 26.73S TECHNOLOGY Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having 26.86 minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). 208 26.86.1 Frame size 45 x 70 mm Metre 300 705.85 211755 209 26.86.2 Frame size 45 x 85 mm Metre 200 926.35 185270 210 26.86.3 Frame size 50 x 100 mm Metre 200 947.7 189540 211 26.86.4 Frame size 50 x 125 mm Metre 200 1075.7 215140 SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), m i n i m u m compressive 26.88 s t r e n g t h 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. 212 26.88.1 30 mm thick Sqm 300 4764.2 1429260 213 26.88.2 35 mm thick Sqm 200 5432.85 1086570 Total 191458057.50
Item Breakup - E-Execution of all work as per schedule
Making bores of suitable Metre size rotary drillingusing either direct mud circulating method or reverse circulating method with contractor's Rig, Equipments and casing pipes if required. (A) Through all types of soil except rock, stone or boulders for depth. i) From G.L. to 30m.
Making bores of suitable Metre size rotary drillingusing either direct mud circulating method or reverse circulating method with contractor's Rig, Equipments and casing pipes if required. (A) Through all types of soil except rock, stone or boulders for depth. ii) From 30m. to 60m. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Making bores of suitable Metre size rotary drillingusing either direct mud circulating method or reverse circulating method with contractor's Rig, Equipments and casing pipes if required. (A) Through all types of soil except rock, stone or boulders for depth. iii) From 60m. to 90m.
Making bores of suitable Metre size rotary drilling using either direct mud circulating method or reverse circulating method with contractor's Rig, Equipments and casing pipes if required. (A) Through all types of soil except rock, stone or boulders for depth. iv) From 90m. to 120m.
Making bores of suitable Metre size rotary drillingusing either direct mud circulating method or reverse circulating method with contractor's Rig, Equipments and casing pipes if required. (B) For drilling through rock, stone or boulders etc. below ground level
Supplying 300mm dia PVC pipe of '80SCHEDULE' having wall thickness 18 mm of "Ori- plast" or Supreme or anyother approved brand confirming to ASTMD-1785.
Supplying 200mm dia PVC pipe of '80 SCHEDULE' having wall thickness 12.7 mm of "Ori- plast" or Supreme anyother approved brand confirming to ASTMD-1785.
Supply 200mm dia reinforced glass fibre strainer 6mm thick PIONEER or VMT make orapproved brand.
Supplying following PVC Each accessories and specials for tube well assemble - a) Nipple 300mm long,300mm dia - 1no b) Topcap 300mm dia - 1 no. c) reducer 300x250mm dia -1no d) Nipple 150mm long, 250mm dia - 1no. e) reducer 250x200mm dia -1no. f) Tail plug 200mm dia- 1 no. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Doing electric resistivity Each test by some approved institute like IIT with proper report for each location. One location shall include of minimum 3(three) no of points. [Unit'Each' = 'Each Tube Well']
Supplying including fitting Each and fixing and jointing in position 300mm dia MS screwed Cap of suitable size.
Packing the annular space cum around the tube well pipes with 3mm to 6mm size clean gravel with contractors materials.
Supplying and maintaing Set centering guides (each set comprises of three guides).
Supplying, fitting and fixing Each welded MS pipes 200mm dia and 1.80m long long bail plug at the bottom containing inside and lowering in plumb in depth below level.
Development of well with Each contractor's compressor as per direction of the Engineer-in- charge. Note: Here unit Each means Each DT well.
Making trial boreing 50mm Metre dia (Each trial bore not more than 300m depth).
Pumping continuously or a total of 48 hrs. with contractor's pump, labour and equipments and testing the yield.
Doing electric resistivity Each test some approved institute like IIT with proper report for each location. One location shall include a testing of minimum 3 (three) nos. of points.
Supplying, fitting, fixing and Set commisioning of a submersible pump set complete for 5000 GPH capacity with motor name Calama or KSB with suitable starter (make L&T or MEI or Crompton) for 300mm x 200mm dia tube well, 80m head conforming to the requirements as per CEE's specification No. CEE/S/185/Submersible pump/9/98. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of Portland slag MT cement from reputed manufacturer conforming to:IS 455 with latest correction slips, including all handling,loading, unloading, lead, lift,descent, ascent,transportation storage at siteetc. complete.
Conducting CHUM test for Each pile foundation including mobilisation etc. complete
Conducting CBR Test on the Numbers ground and on the top of layer as decided by the Engineer-in-Charge by suitable method and submission of test reports. The work to be done under the supervision of Rly. Officials. The work to be executed by means of dynamic cone penitration method as per ASTMD.6591.09 and IRC/37/0212. The rate is including all taxes, GST.royalty, lead, lift, descent, ascent, road taxes etc. The reports shall be submitted in duplicate.
Execution cantilever footpath slab, Deck slab, Footpath Railing, crash barrier, Girder, T- beam, friction slab etc. as per Indian Railway's drawings and specifications or as directed by Engineer in charge with RCC design mix of M:30/M-35/M-40/M- 45 Grade (Cast in situ) machine mixed, machine vibrated and machine batched using 20mmgraded crushed stone aggregates and coarse sand of approved quality, Admixture in recommended proportion are required to be used in mix design to accelerate or retard setting of concrete and /or improve workability without impairing strength and durability complete as per specification, The rates includes contract or rigid steel shuttering with necessary staging, cantering, cutting, bending binding with contractors galvanized binding wire f16SWG, admiture, all lead lift, descent, royalty, and taxes if any, complete, The payment towards cost of cement & HYSD bars (reinforcement) will be done vide relevant schedule. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supplying testing fitting, Each fixing and welding with stud guns etc. of normal headed shear studs/shear connector 25mm dia And 200mm length conforming to IS 395- 66 as per specification of RDSO Drg. along with ferrules to top flange of girder for deck slabs as per the direction/approval of Engineer in charge. (In case shear connectors of any other size is required the payment shall be made on the pro-rata basis in the portion of the weight of the shear connectors). Note here unit each means each stud.
Storage 1050x450x2100mm to be made out of 25mm PLPB top and 18mm prelaminated board side panels, nshutter,sheive and bottom. All exposed edge to be covered with 2mm th PVC edgebanding.The back to be made of 9mm prelaminated partical board. All hardware to be from Nexgel,hetich, hafle or equivalent. Total 44312036.24
Item Breakup - F-Execution of all work as per schedule
Preparation of Design & Sqm drawing for New office building/steel structures/sheds (Including inside accessories should be as per latest circular). Notes: (i) The contractor will carryout detailed survey and prepare GAD and get it approved from Railway. (ii) The rates are inclusive of visits to site if required. The site of the work falls under the jurisdiction of Dy.CE(Con), KGP II. (iii) The above quantities are approximate. The Railway reserves the right to increase/decrease the same. Additional special conditions of contract: i) The Agency will get the design checked from Railway. For this purpose Agency will ensure the presence of his representative in the offices of Railway authorities whenever required. Nothing extra will be payable for the above and the rate is inclusive of above. ii) After drawing got approved by SER-CONST-HQ-ENGG/SOUTH EASTERN RLY Railway, the Agency will have to submit three copies of initial design calculations with 3 ferro copies of drawings to Railway for record. Design calculation should be clearly written and bound in book form. iii) On clearance of design criteria from Railway for any modification, agency will carry out detailed design again as required without any loss of time after clearance of design parameters. He will also be prompt in clarifying the observations/doubts of the Railways. No extra payment shall be made for the any alterations. iv) Design and drawing after approval shall be property of S. E. Railway who shall have exclusive right to use or reuse it elsewhere. The consultant shall have no claim whatsoever in this regards. v) Based on the design note approved by Rly, the Agency will prepare final general arrangement drawing. Mode of payment: i) Visit to site and collection of field data from site, and detailed design of and preparation of GAD, submission to Railway 3 sets of GAD (Ferro copy), design calculation 3 booklet = 20%. ii) After acceptance of Railway = 50%. iii) Final submission of drawing approved in item (ii) above in reproducing tracing films 3 copies and soft copy on CD, 3 sets of ferro prints for each drawings, final design calculation booklet. Payment will be made after signature of Railway authorities in final drawing =30%. Note: Proof checking of the Design should be done from any Govt. E n g i n e e r i n g College/ University. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Design of Sub-structure and Numbers foundation and making detailed drawings (All structural components excluding Superstructure in ROB Proper) including superstructure of approaches for major bridges / Road OverBridge / Road Under Bridge/ Rly Flyover etc. This rate is inclusive of supplying of soft copy of each drawing in CD ROM, one copy intracing paper & 05 nos. ferroprints. (a) For multiple spans of steel / PSC / Composite girder. Mode of payment: 1. Submission of design caluclations and tentative paper print drawing (two copies) and after approval of Railway (Dy.CE/Con/D&D) prima-facia- 30%. 2. After submission of proofed checked copy of design in book form and drawing in tracing film,soft copy and after approval of Railway (CE/CON) -40% . 3. After signature of all concerned and submission of three design booklet, three tracing film and three ferro print of drawing by the agency - 30%. Note: Proof checking of the Design should be done from any Govt. Engineering College/ University. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Preparation of structural Sqm design & Drawing of scafolding for different types multi storied buildings. The Rate includes all taxes, lead, lift, descend, and ascend, labor, materials etc. complete. The above quantities are approximate. The Railway reserves the right to increase/decrease the same. Additional conditions: I) The Design & Drawing will be proof checked from any any Govt. Engineering College/University. The Agency will get the design checked from Railway. For this purpose Agency will ensure the presence of his representative in the offices of Railway Authorities whenever required. Nothing extra will be payable for the above and the rate is inclusive of above. II) After drawing got approved by Railway, the Agency will have to submit three copies of initial design calculations with 3 copies of drawings to Railway for record. Design calculation should be clearly written and bound in book form. III) On clearance of design criteria from Railway for any modification, agency will carry out detailed design again as required without any loss of time after clearance of design parameters. He will also be prompt in clarifying the observations/doubts of the Railways. No extra payment shall be made for any alterations. IV) Design and drawing after approval shall be property of S. E. Railway who shall have exclusive right to use or reuse it elsewhere. The consultant shall have no claim whatsoever in this regards. V) Based on the design note approved by Rly, the Agency will prepare final arrangement drawings. Mode of payment: i) Visit to site and collection of field data from site and preparation of drawing & design, submission to Railway 3 sets of drawing & Design with approval from Dy.CE/C-II/KGP office = 50%. ii) After approval from Construction HQ = 50%. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Preparation and submission Each of Final report giving complete and comprehensive record of investigations, laboratory test reports and calculations in approved format. Total 779531.65
Item Breakup - G-Execution of all work as per schedule
size 20 cm as per direction of the officer-in-charge. 8.13 Providing and stacking of Each 100 40 4000 Cestrum nocturnum (Raat ki Rani) of height 60- 75 cm. 68 with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. 8.43 Providing a n d stacking of Each 25 40 1000 Largerstroemia i n d i c a of h e i g h t 9 0 - 1 0 5 cm. 69 multibranched in poly bags of size 25 cm as per direction of the officer-in- charge. 8.48 Providing and stacking of Each 50 110 5500 Mussaenda erythrophylla (Rosea) of height 60- 75 cm. 70 multi branched in earthen pots of size 25 cm as per direction of the officer-in- charge. 8.54 Providing and stacking of Each 100 40 4000 Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm 71 in Earthen pots of size 20 cm as per direction of the officer-in-charge. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY 8.58 Providing and stacking of Each 100 35 3500 Tabernaemontana coronaria (Chandni single) of height 72 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.76 Providing and stacking of Each 50 130 6500 Thuja compacta of height 75-90 cm., conical shaped, 73 well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge. 9.0 CREEPER PLANTS 9.1 Providing and stacking of Each 10 45 450 Allamanda cathartica of height 30 cm to 45 cm. in
P l a s t i c p o t s & a s per direction o f the officer-in- charge. 9.8 Providing and stacking of Each 10 30 300 Jasmine grandiflorum (chameli) of height 30 cm to
Earthen pots / Plastic pots & as per direction of the officer-in-charge. . 11.0 MEDICINAL PLANTS 11.10 Providing and Stacking of Each 50 50 2500 Lemon grass of ht. 30 cm with multi branches in Poly 76 bag of size 20 cm. as per direction of the officer-in- charge. 11.14 Providing and Stacking of Each 25 50 1250 Sarpgandha well developed 77 in poly bag of size 20cm as per direction of the officer- in-charge. 11.17 Providing and Stacking of Each 10 30 300 Aprajita Blue well developed 78 in poly bag of size 20cm as per direction of the officer- in-charge. Total 1079992.95
Item Breakup - H-Execution of all work as per schedule
Supply of LED 2x18/20W T- Numbers 8 indoor type Tube Light fitting with Aluminum housing having Luminous fl u x efficacy 120 Lm/Watt,CRI75 for each tube light, with Constant current driver complete with lamp and all accessories.
Supply and erection of LED Numbers Lamp 7-9W,230V.
Supply of 1x18/20W T-8 LED Numbers Tube Light fitting Constant current driver complete with lamp and all accessories. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of Energy efficient Numbers (5-star rating) BLDC AC ceiling fan of 1200mm sweep with regulator i n c l u d i n g suspension arrangement.
Supply of Exhaust fan Numbers 250mm/300mm sweep B L D C Heavy duty copper wound with anticorrosive blade complete with frame, and other accessories.
Supply of Double door Numbers Distribution Board IP-43 wall mounting type with provision of 1x32A, 10kA D o u b l e Pole MCB as Incoming & 4 x Single Pole MCB 6A 16A,10kA as outgoing as per IS/IEC 60898-1,housing in a SP&N Prewired 6-way CRCA steel sheets enclosure with Neutral Link, Earth bar & Din Rail etc.
Supply of LED Street Light Numbers Luminaire in Die Cast Aluminium Body with heat sink in aluminium extrusion, IP66, LED light 50-60 Watt, 5700-6500k
Supply of Heat shrinkable Numbers type indoor/outdoor end termination/Straight through kit as per IS 13573 : Part 3, suitable for 11kV, 3 Core 70/95/120/185-300 Sq.mm XLPE Cable.
Supply of Earth cone of 2.8 Numbers M long, 54.4mm inside dia and 60.2 mm out side dia GI pipe. The pipe having conically tapered at one end and having sufficient no. of holes of 12mm dia. including connection by 2x8.No SWG GI wire and making of earth cone sump box .
Supply of GI pipe 3"/4" dia Metre with socket for laying/verticle lifting of cable.
Supply, erection and testing Numbers of Maintenance free Earthing system comprising of 48.3 mm dia.meter, 3 meter long earthing electrode of low carbon high tensile steel with 250 microns copper coating + carbon based conductive back fill compound & copper Clamp including suitable length earthing GI strip of 40 x 3 mm for termination works. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of MCB 16-25A, Numbers 10Ka with 3/5 modular type socket with starter in a enclosure for A.C point similar to DHDUCDP0253016-25 with complete wiring
Supply of Triple pole 11 Set KVx400 A Capacity gang operated air break switch complete with insulator, DO fuse, support channel, clamps for fixing in 4 pole/DP structure along with operating handle and locking arrangement etc.
Supply complete set with mounting hardware arrangement, metal oxide type (1Set consists of 3 Nos. LA) Make Rly. approved brand.
Supply of 11 KV Pin Numbers insulators complete with all accessories.
Supply of 11 KV Disc Numbers insulators complete with all accessories.
Supply of MS Sheet Cable Numbers Busbar Chamber IP-43 wall mounting type 3 phase and neutral, 416 Volt with 4 Nos copper bus bar of 100A each (similar to Havells Cat.No.IHBC010004)
Supply of Busbar Chamber Numbers IP-43 wall mounting type 3 phase and neutral, 416 Volt with 4 Nos copper bus bar of 400A each, all assembled in 14 SWG sheet steel, powder coated MS Box Enclosure (similar to Havells Cat. No. IHBC040004)
Supply of Busbar Chamber Numbers IP-43 wall mounting type 3 phase and neutral, 416 Volt with 4 Nos copper bus bar of 63A each, all assembled in CRCA steel sheets enclosure (similar to Havells Cat. No.IHBC006304)
Supply & erection of Fire Numbers fighting equipment 5 Kg. capacity (DCPT)
Supply of GI Flate of size Metre 40mm x 3mm for Earthing o f all structure and vital equipment including r e q u i r e d n u t , bolts & sockets etc.
Supply of bulk head fitting Numbers complete with LED lamp of
watt accessories. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of Service main DB Numbers consisting of one no. 5-30A electronics energy meter(LCD display), & RCCB 1x32A, 30 mA as per IS/ IEC 61008-1, housing in duly painted CRCA steel sheets enclosure with cable entry arrangement .
Supply of Street light panel Numbers with Astronomical/digital timer 24hrs, contactor rating 32A/TP MCB rating 40A/TPN. (similar to Havells IHXTS0306A).
Supply of Distribution Board Numbers Double door type IP-43 wall mounting type with provision of 1x63A Double Pole MCB as Incoming & 4 x 20A-32A Double Pole MCB , a s outgoing as per IS/IEC 60898 & 60947-2,housing in a SP&N Prewired MS Box Enclosure with Neutral Link, Earth bar & Din Rail etc.
Supply of LT DB comprising Numbers 1x63A ,16kA TPN MCCB with busbar as incoming and 4x32A, 4x16A,10kA DP MCB as outgoing as per IS/IEC 60898 & 60947-2. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply galvanized flange mounted t y p e continuously tapered, polygonal cross section, 20 s i d e d High mast (Grade BSEN 10025 - S355J0) of 20M normal mounting height with minimum diameters of 200mm at the top and 540 mm at the bottom, Minimum plate thickness 6mm,Base Flange diameter:740mm, Flange thickness:30 mm, PCD (Pitch Circle Diameter) :650mm, complete with 3 point suspension system, head frame canopy, 6mm stainless steel wire ropes to carry up to 12.Nos luminaries complete mounting bracket & accessories, one length 2.5 sqmm 8 core flat electrical trail copper cable 1100V grade, foundation bolt, nut, washer and Top & Bottom templates, lightning arrestors, lantern carraige, double drum winch, 3-phase 2HP Motor, earthing arrangement etc suitable for withstanding basic wind speed of 180KMPH including suitable 3PH power tools, twin aviation obstruction neon light as well as manual arrangement for raising lowering of lantern carriage with all necessary accessories, including suitable size Outdoor stand mounted duly painted Feeder Pillar box made by 1.6mm thick CRCA steel sheets Enclosure with locking arragment comprising 63A Four Pole MCB as incomer, timer, Triple Pole contactor for the Automatic switching of luminaries and power tool control with 9A contactors and raise lower push button.
Supply of high intensity Numbers long range, energy saving d i e cast aluminium IP-66 flood light luminaire with 190-200 W high power LED as light source with reflector and lens of reputed make
Supply of Outdoor type LED Numbers light fitting (IP-66) for front lighting, 70-80 Watt, suitable for voltage 230V AC complete with driver and all other accessories. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of recess mounted Numbers LED panel light 10-12 Watt with driver similar to Havells LHEBLDPFPVNW010 model.
Supply of Electric storage Numbers water heater of 15L capacity geyser with 5star rating similar to Havells GHWCBNTIV015
Supply of Wire Mesh type Metre Cable tray of Stainless Steel, 300mm width with SS fixing bracket, coupler & bend plat with suitable SS nut, bolt & washer etc.
Supply of 1.1 KV 3.5/4 CORE Numbers 50/70/ 95/120 sq.mm LT straight through heat shrinkable kit.
Supply of IP65 (dust proof & Numbers jet water tight) junction box, made of high quality thermoplastic having high grade internally embedded gasket made of Polyurethane, fireretardant & self extinguishing, JB size (L X B X H) of : 300mm X300mm X 170mm fitted with 1No.63A DP MCCB, with minimum 2.Nos 2Cx70/50Sq.mm cable entry arrangement with TPN- 100A, 4-Way cable connector.
Supply of IP65 (dust proof & Numbers jet water tight) junction box, made of high quality thermoplastic,Insulated & c o r r o s i o n free, acidand chemical resistant, having high grade internally embedded gasket made of Polyurethane, fire retardant & self extinguishing, JB having size (L X B X H) of :360mm X 500mm X 180mm fitted with 1No. 160A DP MCCB,with minimum 2.Nos 2Cx150Sq.mm cable entry arrangement with (TP-200A cable connector terminal) / loop in loop out terminal.
Supply of programmable Numbers time switch 24 Hrs code with contracator 3 pole with AC coil i.eAmp-32 make Havells or Similar. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of IP65 (dust proof & Numbers jet water tight) junction box, made of high quality thermoplastic,Insulated & c o r r o s io n free, acid and chemical resistant, having h i g h gradeinternally embedded gasket made of Polyurethane, fire retardant & self extinguishing, JB having size (L X B X H) of :600mm X450mm X 250mm (approx) fitted with 2 No. TPN-100A, cable connector terminal / loop in loop out terminal with minimum 4.Nos 4Cx 70/50Sq.mm cable entry arrangement.
Design, display of wall hanging / Foot fl o o r mounting type LED illuminated glow sign / d i r e c t i o n boards in half elliptical shape. All specifications to be followed as mentioned in GEN.
Supply of Automatic Supply Numbers change over color light signaling panels,160A for 3 source single phase supply suitable for 25KVA,240V AT as per RDSO specification. CLS panel.
Supply of single phase Set Submersible pump set for use in bore wells for handling clear cold water having motor of wet type for continuous rating, Delivery 1.1KW/1.5HP with pump controller/ starter as per site requirement, including PP Rope 14mm, 3COREX4.Sq.mm.FLAT CABLES with flexible copper conductor as per site requirement or minimum 90m SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply consisting with 4-pole MDO (Manually Operated Draw Out) type ACB 800 A, 50KA, Microprocessor Based - 02Nos. as incoming, 4-pole M F (Manually Operated Fixed) type ACB 800 A, 50KA,Microprocessor Based - 01 No. as buscoupler and FP 400A, 50kA microprocessor based MCCB -02 Nos, FP 250A, 50kA microprocessor based MCCB - 05 Nos, FP100A, 36kA microprocessor based MCCB - 03Nos., FP MCB 63A, 10kA with 3PP (Protected Pole) - 02 Nos. as outgoing with suitable Cu.Bus bar, Automatic Fire Ball, Digital Multifunctional Meter in each Incoming & Outgoing MCCB,Capable to measure and display Voltage, Current, Frequency, Power factor, kW, kVAR, kWh, kVAh, kVARh etc., appropriate spreader link f o r MCCB and with necessary item for seal the cable entry and outgoing point.
Supply of 5M HDG (Hot Dip Numbers Galvanized) double arm Octagonal Pole with cable junction compartment Insulated Cable Connector 4-way and SP 6A MCB, Pole top dia.70mm, bottom dia. 130mm, sheet thickness 3 m m , base plate dimensions (L X B X T)- 200mm X 200mm X 12mm with 1000 mm long double arm and foundation bolts etc. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of painted outdoor Numbers pillar box made of 2mm thickness sheet steel, rust protected,powder coated w ith single door & locking arrangement as per IP-54, consisting with FP MCCB 250A, 50kA Microprocessor Based - 01 No. as incoming and FP MCCB 100A, 36kA Microprocessor Based - 02 Nos., FP MCCB 63A, 36kA Microprocessor Based - 04 Nos.as outgoing with suitable Cu. Bus-bar, Digital Multifunctional Meter in eac h Incoming & Outgoing MCCB, Capable to measure a n d display Voltage, Current, Frequency, Power factor, kW, kVAR, kWh, kVAh, kVARh etc., appropriate spreader link for MCCB and with necessary item for seal the c a b l e entry and outgoing point.
Supply of Cable loop box (of Numbers fibre body) for 3-Phase incoming and outgoing connection consists of 3- Phase and neutral terminal and 15/16 Amps K-fuse as p e r relevant ISS, with suitable bridge arrangement of size: 240mmx 140mm x 100mm and all other accessories.
Supply of Industrial Plug & Numbers Socket ofcapacity: 32 A, 5 Pin, 3P+N+E with 32A,10kA FP MCB with 3PP (Protected Pole)-01No. and Plug and Socket Distribution Board.
Supply of VTP & N 8-Way Numbers DB (Double Door) consisting with FP 100A, 36kA Microprocessor Based MCCB - 01 No. as incoming and TP MCB 63A, 10kA- 6 Nos. as outgoing with Cu. bus-bar, Neutral links,Earth bar, c a b l e gland, appropriate spreader link for MCCB etc.
Supply of TP&N 4-Way DB Numbers (Double Door) consisting with FP MCB 63A, 10kA with 3PP (Protected Pole) - 01 N o . as incoming and SP MCB 32A, 10kA- 8 no. or DP MCB 32A, 10 kA- 4 Nos. as outgoing with bus-bar, N e u t r a l links, Earth bar, cable gland etc.
Supply of Switch fuse unit Numbers (rewireable type) 415V TP with Neutral link capacity 63A. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of Switch fuse unit Numbers (rewireable type) 415V TP with Neutral link capacity 100A.
Supply of FP 125 Amps, Numbers 35kA Microprocessor Based MCCB including spreader link and sheet steel powder painted enclosure with proper wiring to complete job.
Supply of FP 200 Amps, Numbers 36kA Microprocessor Based MCCB including spreader link and sheet steel powder painted enclosure with proper wiring to complete job.
Supply & erection of Sand Numbers bucket/ Fire buckets complete set as per IS : 2546 (set of four nos. of 9 litre capaity)
Supply & laying of Electrical Numbers insulated IS marked Insulated rubber mat 2m x 1m x 2cm.
Supply Diagram in originalalong with 06 copies on A-0 papers of different locations showing superimposition of cable route, HT/ LT panels,transformers, location of tubular poles and all other electrical items and works.
Supply & erection of Early Numbers Streamer Emission (ESE) Lightning Arrestor/ Protection system asper NFC 17-102 suitable for an apartment/building upto G+6 storied along with all necessary accessories such as Mounting Base,Conductor Shaddle, Down Conductor, Earthing system,Lightning event counter etc.
Supply of Residual Current Numbers D e v i c e with Socket 16Amp.with Steel Enclosure (SRCD DBOX) for Geyser point. (similar to Havells Cat. No.Havells SRCD WOCP Dboxx Steel Encl)
Supply of Ding Dong Door Numbers Bell. Total 7930022.00
Item Breakup - I-Execution of all work as per schedule
Erection, commissioning of Outdoor T y p e Distribution Transformer, Plinth Mounting type of Rating 250KVA/ 500 KVA, 11KV/433V, 3-phase, 50Hz, O i l Immersed, Non-Sealed type (Transformer tank body and cover are bolted), Copper wound, Primary Winding in Delta and Secondary Winding in Star (Vector symbol- Dyn11), ONAN Cooled Transformer. Conforming to IS 1180 (Part 1):2014 with amendment nos. 1,2,3,4 or latest.All tests performed as per CEGE guide line for EIG of Sub-Station Dated-17-12- 2024. on site at the time of commissioning. (Transformer will be supplied by Railway)
Erection, commissioning of 11kV panel with 01 No VCB of capacity 3 PH, 11kV, 630Amps including copper bus bar all other associated accessories . (VCB Will be Supplied by Railway)
Supply & erection of 110 Metre mm or higher dia. HDPE pipe of grade PE-100 for H D D requirement including laying and jointing of HDPE Pipe with suitable size couplers, plugs, end caps, spacer, T band etc. with min depth of 3 mtrs/ as per the site conditions with proper tools, for cable running applications
Supply & erection of 160 Metre mm or higher dia. HDPE pipe of grade PE-100 for HDD requirement including laying and jointing of HDPE Pipe with suitable size couplers, plugs, end caps, spacer, T band etc. with min depth of 3 mtrs/ as per the site conditions with proper tools, for cable running applications
Erection and installation of Square wall hanging/ floor Foot m o u n t i n g type LED illuminated sign / direction boards in half elliptical shape. All specifications to be followed as mentioned in GEN. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection,testing commissioning of FP 125 A m p s MCCB,FP 200 Amps MCCB, main Switch fuse unit (rewireable type) 415V TP in sheet steel enclosure, 63Amps./100 Amps including necessary masonry work and supply & fixing of all types of cable gland, cable sockets, lugs, requisite nuts & bolts,with rain shed protection etc ,.
Fixing and commissioning of Numbers Cable loop box (of fibre body) for 3-Phase incoming and outgoing connection consists of 3-Phase and neutral terminal and 15/16 Amps K-fuse and all other accessories with proper termination of cables through glands and fixing with 25 X 3 mm MS flat bar.
Erection of LED 2x18/20W Numbers T-8 indoor type Tube Light fitting of including supply & erection of necessary clamps & masonry work,
Erection of 1x18/20W T-8 Numbers impact proof, surface mounting IP65 LED Tube Light fitting with masonry work.
Erection of Energy efficient Numbers (5-star rating) AC ceiling fan with regulator and all accessories
Erection of Exhaust fan with Numbers all accessories, including masonry work.
Erection,testing commissioning of MCB DB i n c l u d i n g necessary masonry work and supply & fixing of all types of cable gland, cable sockets, requisite nuts & bolts etc.
Erection, commissioning of service main energy meter DB including necessary masonry work and supply & fixing of all types of cable gland, cable sockets, requisite nuts & bolts etc.
Erection Galvanised Octagonal street l i g h t pole with all accessories of including earth connection & Erection of LED street light fitting with wiring from MCB to light fitting.
Erection of LED Street Light/ Numbers Outdoor Light Luminair on wall/ structure/ shed (except Octagonal/SST Pole) with all accessories for fixing. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection & termination of Numbers HT Heat shrinkable type i n d o o r / outdoor end termination/Straight through cable jointing kit.
Excavation of earth in any Numbers kind of soil & Erection, testing & commissioning of Earth cone as per Drawing No. CEE/G/A3/P-134.
Erection/ Laying of GI pipe Metre 3"/4" dia with socket/ clamp for laying /vertical lifting of cable
Erection of MCB 16-25A Numbers 10KA with 3/5 pin 15A modular type socket with starter in a enclosure for A.C point similar to DHDUCDP0253016-25 with complete wiring.
Erection,testing commissioning of Triple pole 11 KVx400 A Capacity gang operated air break s w i t c h complete with insulator, DO fuse, support channel, clamps for fixing in 4 pole/DP structure along w i t h operating handle and locking arrangement etc.
Erection of 11 KV LA Set complete set with mounting hardware arrangement, metal oxide type (1Set consists of 3 Nos. LA) Make Rly. approved brand.
Erection Chambers IP-43 wall mounting type including rainshed protection (for outdoor installation) fabrication work,necessary cable termination & masonry work,
Erection of GI Flate of size Metre 40mm x 3mm for Earthing o f all structure and vital equipment including required nut, bolts & sockets etc.
Erection of 33KV/ 11KV/ LT Numbers pin/ disc/ shackle insulator complete with pin,clamp,stalk etc. complete with all acessories.
Erection of bulk head fitting Numbers complete with LED lamp of
watt accessories.
Erection, commissioning of Control box or Panel for Street Light including supply & erection of all fixing bolts, cable termination and masonary work. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection,testing commissioning of out door type (Rain water tight) Feeder Pillar/ Location box floor/ plinth mounted type including necessary masonry work & cable termination work.
Supply , fixing, wiring & Point commissioning of PVC concealed conduit/ PVC conduit surface/ casing c a p p i n g wiring by PVC FRLSH insulated copper cable 1100 V grade 1.5 Sq.mm through PVC conduit with running earth by 14SWG tinned copper wire/ 1.5sqmm copper wire through out the wiring including supply and fixing of hot deep GI sheet concealed Modular switch b o a r d , M o d u l a r switch, socket & electronic fan regulators, ceiling rose/holderetc. (a) Light, Bell & Fan point wiring with 6 Amp, Modular switch with Metal back Plate etc.
Supply , fixing, wiring & Point commissioning of PVC concealed conduit/ PVC conduit surface/casing c a p p i n g wiring by PVC FRLSH insulated copper cable1100 V grade 2.5 Sq.mm throughPVCconduit with running earth by14SWG tinned copper wire/ 2.5sqmm copper wire through out the wiring including supply and fixing of hot deep GI sheet concealed Modular switch b o a r d , M o d u l a r switch, socket & electronic fan regulators, ceiling rose/holderetc. (b)5/6 Amp., 3/5 pin plug socket point wring with 6 Amp, Modular type switch with Metal back Plate & socket. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply , fixing, wiring & Point commissioning of PVC concealed conduit/casing c a p p i n g wiring / PVC conduit pipe wiring by PVC FRLSH insulated copper cable 1100 V grade from the nearest DB along with running earth of 4sqmm copper wire through out the wiring including supply and fixing of hot deep GI sheet concealed switch board for Modular switch, socket and other wiring materials to make the work a complete unit.(c) 15 Amp plug socket point wiring by 4 Sq.mm PVC FRLSH insulated copper cable with 16 Amp, Modular type Metal back Plate switch & socket, etc.
Supply & fixing,wiring & Metre commissioning of PVC concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 4 sqmm PVC FRLSH insulated copper cable 1100V grade through PVC conduit with running earth by 4 sqmm copper wire through out the wiring for drawing/extension of supply from Main D B / B u s b a r chamber to service main board/Circuit DB/Air conditioner point by 4sq.mm cable. Note- (Quantity per meter means: one meter conduit with two meter 4sqmm PVC FRLSH insulated copper cable & one meter 4 sqmm copper wire for running earth)
Supply & fixing,wiring & Metre commissioning of PVC concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 2.5 sqmm PVC FRLSH insulated copper cable 1100V grade through PVC conduit with r u n n i n g earth by 14SWG tinned copper wire/1.5 sqmm copper wire through out the wiring for drawing/extension of supply from Main DB/Circuit DB to switch board/Circuit DB by 2.5 sq.mm cable. Note- (Quantity per meter means: one meter conduit with two meter 2.5sqmm PVC FRLS insulated copper cable & one meter 2.5 sqmm copper wire for running earth). SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply & fixing,wiring & Metre commissioning of PVC concealed conduit/PVC conduit surface /casing capping wiring by 2 Nos 6 sqmm PVC FRLSH insulated copper cable 1100V grade through PVC conduit with running earth by 6 sqmm copper wire through out the wiring for drawing/extension of supply from Main D B / B u s b a r chamber to service main board/Circuit DB Note-(Quantity per meter means: one meter conduit with two meter 6sqmm PVC FRLSH insulated copper cable & one meter 6 sqmm copper wire for running earth)
Laying of HT/LT cable (Rly Metre supplied) along the road and refilling of excavated earth as per CEE/GRC's Drg No. CEE/G/PA3/134 including supply & erection of cable gland, pyramid/Flat sockets, requisite nuts & bolts & all allied works.
Laying of HT/LT cable (Rly Metre supplied) Across the road through GI/RCC/CI pipe and refilling of excavated earth as per CEE/GRC's Drg No. CEE/G/PA3/134 including supply & erection of cable gland, pyramid/Flat sockets, requisite nuts & bolts & all allied works.
Erection of cable In the air, Metre fixing on wall,through pipe/drain rail, structure with MS clamp with nut & bolt.
Laying of extra cables in the Metre excavated same trench duly following GEN.
Excavation of trench in all Metre kinds of soils ,concrete including soft rocky area and clearing of roots oftrees, bushes, rocks, blast etc., to a depth of 1m & width 0.3m including supply and laying of Double wall Corrugated Pipe with collars of 103mm inner dia and 120 mm outer dia with couplers and sockets as per RDSO specf. No RDSO/SPN/204/2011/Ver.1.1 Supply of one coupler for 6m of DWC Pipe and two couplers for 30m of length included. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Boring/punching underground crossing of Railway track/road with pipe pushing by HDD technology & crossing HT/LT power cable below railway t r a c k / r o a d through pipe. Note: The boring profile should be recorded and submitted for verificationof depth and length of boring
Concrete for foundation in cum 1:3:6 ratio in any kind of soil including excavation and supply of all materials viz. sand, cement and ballast for TR plinth/SST pole/Rail Pole//Pillar Box/fencing panel/structure etc.
Dismantling and removal of Each Span existing overhead LT/HT line with accessories. Note: Here Each Span means Span.
Dismantlling / Shifting of Numbers Rail Pole/SST pole/GI/MS Structure/Location box/Control Panels/Busbar chamber/DB/Pre-cooling socket/Lavolite Transformer/Battery charger etc including a s s o c i a t e d cables, light fiiting & wiring with gas cutting or any other means without appreciable damage.
Transportation of Railway MT supply materials from Railways depots in CKP/ADA/KGP/RNC division to site of work with lead
Supply and erection of RCC Numbers make cable route marker size L-12" ,B-6" , H-30".
Supply & Installation of Numbers Standard enameled 33/11 KV/400 Volt danger board size 6x"8" as per IS:255 having impression of skull & bone with written "DANGER" 11000/ 400 Volt 2/2 Hindi, English & local language.
Supply Galvanized stay set as per IS: 2141 - 2000, for overhead line complete with 19/20mm dia x 1.8 M long stay rod, anchor plate of 45 cm x 45 cm x 7.5 mm, thimble stay clamps, turn buckle (20 mm x 600mm) 7/4 mm dia GI stay wire with guy insulators complete with all accessories. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply Erection, fabrication MT & painting of Miscellaneous iron work MS angle, flats, channel required nut, bolts e t c . for Small steel parts except rail pole for Fabrication of cable tray/ Cross arms channel/ 4pole/ 2 pole structures etc.
Erection, commissioning of (a) Hot d i p galvanized flange mounted type polygonal tapered type High mast of 20M long nominal mounting h e i g h t complete with all necessary accessories including LED Flood Light luminaire (200W, 12Nos in each mast). And (b) Outdoor stand mounted Feeder Pillar complete with all necessary accessories including foundation of high mast & Feeder Pillar as per approved drawing.
Erection of Outdoor type Numbers LED light fitting (IP-66) for front lighting 70-100W/190- 200W flood light (exclusive of high mast), suitable for voltage 230V AC complete with driver and all other accessories.
Erection of recess mounted Numbers LED panel light 10-12 Watt with driver including electrical connection, supply & erection of necessary clamps & masonry work.
Installation commissioning of Gyeser 15L Capacity including electrical connection, wiring & necessary masonry work/ plumbing connection work.
Fabrication, installation of Wire Mesh type Cable tray of Stainless Steel, 300mm width with SS fixing bracket, coupler & bend plat with suitable SS nut, bolt & washer etc.
Erection of 1.1 KV 3.5/4 Numbers CORE50/70/ 95/120 sq.mm L T straight through heat shrinkable kit.
Erection box with lugs,spreader link and cable gland.
Erection of CLS panel with Numbers lugs,spreader link and cable gland.
Erection of programmable Numbers timeswitch 24 Hrs code with contractor 3 pole with AC coil i.e Amp-32 make Havells or Similar. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Installation commissioning of single/ t h r e e phase Submersible pump set for use in bore wells for handling clear cold w a t e r with pump controller/starter as per site requirement,including lowering/laying of pipe, RR Rope12mm, FLAT CABLES with flexible copper conductor.
Erection of Plug & Socket Numbers Board, in 3P&N enclosure with 3-pole + SC (scraping earth) Socket with 4P MCB of rating 32 A.
Installation commissionig of 1.5/2 Ton split Air Conditioner with rotary compressor including e l e c t r i c a l connection, additional copper pipe (if required) wiring & necessary masonry work. (Split A.C will be supplied by Railway)
Supply & installation of Set mobile charging a r r a n g e m e n t consisting with 04 nos. 5Amp. modular plug socket 240V 50Hz., 04nos. 6 Amp. modular switch along with indicator and fuse.
Erection,testing commissioning of LT ACB panel with appropriate spreader link for MCCB ,Cable gland & necessary item for seal the cable entry and outgoing point and complete the job including necessary masonry work & cable termination work.
Erection of Residual Current Numbers D e v i c e with Socket 16Amp.with Steel Enclosure (SRCD DBOX) for Geyser point. (similar to Havells Cat. No.Havells SRCD WOCP Dboxx Steel Encl)
Erection of Ding Dong Door Numbers Bell
Erection including supply of Each Fabricated Fencing Uprights as per RDSO approved Drawing No.ETI/C/0186, painted with two coats of red oxide zinc chromate primer and finished with two coats of Aluminum paint to I S ; 2 3 3 9 including barbed wire. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Erection including supply of Metre Fencing Panels as per RDSO approved Drawing , painted with two coats of red oxide zinc chromate primer and finished with two coats of aluminum paint IS:2339
Erection including supply of Metre Gates including locking device as per RDSO approved Drawing No.ETI/PSI/121. The gates will be painted with two coats of red oxide zinc chromate primer to IS: 2074 and finished with two coats of aluminum paint as per particulars specified in para 2.6.12 and IS:2339. NOTE: All fasteners, bolts, nuts, locknuts and washers etc. required for assembly and fixing of steel work shall be galvanized.
Earthwork in filling for cum embankment of building, l o w laying area, etc. in all classifications of soil as d i r e c t e d by Engineer in charge. The rate is inclusive of all labour and materials, machineries etc. with all lead, lift, descent, ascent, loading, unloading royalty, all taxes, tools and plant, breaking clods, dressing to final profile and dimensions etc. complete. The work is to be executed with contractor's earth of approved quality and specifications. The rate is also applicable for cutting of earth and levelling.
Supply, spreading, levelling, cum watering and ramming of moorum.
Supply, levelling of 20mm down g r a d e d ballast, padding 150mm
Dismantling of high mast Numbers tower/ lattice tower with all accessories as per site requirements up to 30mtr and deposition to store.
Erection, fabrication , fixing Metre including Supply of copper strip (25 x 3mm) for Earthing of transformer and to vital equipment including required nut, bolts, sockets etc. Total 8906441.00
Item Breakup - J-Execution of all work as per schedule
Concrete for foundation and cum plinth in all type of soil including hard/rocky soil (including excavation and supply of all materials viz., sand, cement, and ballast etc.) Total 2827500.00
Item Breakup - K-Execution of all work as per schedule
Excavation of trench in all Kilometre kinds of soils including soft rocky area and clearing of r o o t s of trees, rocks, bushes, ballast & reconditioning etc., including bailing out water a n d disposal of extra soil including back filling with excavated earth and ramming of trenches after cable laying for the following depths and widths as specified in Technical Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER or any other latest guidelines. Note: In c a s e , trenches are other than prescribed depth & width, Proportionate payment shall be released. Depth 1.2 meter, Width 0.5 meter.
Excavation of trench in all Kilometre kinds of soils including soft rocky area and clearing of r o o t s of trees, rocks, bushes, ballast & reconditioning etc., including bailing out water a n d disposal of extra soil including back filling with excavated earth and ramming of trenches after cable laying for the following depths and widths as specified in Technical Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER or any other latest guidelines. Note: In c a s e , trenches are other than prescribed depth & width, Proportionate payment shall be released.Depth 1.0 meter, Width 0.3 meter.. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Excavation of trench in all Kilometre kinds of soils including soft rocky area and clearing of r o o t s of trees, rocks, bushes, ballast & reconditioning etc., including bailing out water a n d disposal of extra soil including back filling with excavated earth and ramming of trenches after cable laying for the following depths and widths as specified in Technical Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER or any other latest guidelines. Note: In c a s e , trenches are other than prescribed depth & width, Proportionate payment shall be released. Depth 0.8 meter, Width 0.3 meter.
Excavation including clearing of roots of trees etc. in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom. Supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 10262-2019 or latest and IS-456-2000 as per SEM Drawing No. 15 D3 (Sheet-2) on sieved soil of 30 mm over cable and concreting(1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging a n d carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This also includes supply of collar and all the materials for concreting by the contractor. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Excavation of trench in all Metre kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 metre. Track/Pucca road/Platform crossing/Level crossing as per SEM Drawing No.15-D5 or latest including supply, transportation and laying of RCC Pipes (full) with collar (for jointing pipes) Inner diameter/Outer diameter: 100mm/150mm to Specification No. IS:10262- 2019 or latest and IS 456-
Item Breakup - L-Execution of all work as per schedule
Horizontal Drilling by using Metre manual pushing method (also called moling) at minimum depth of 1.5 meter below the formation level of earth as per decision of Engineer in charge. Boring diameter should be atleast 110mm. The ground level shall be considered ignoring the bank height of the bank of the road. Note: DWC/HDPE/GI Pipe Supply is covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after laying of the cables into DWC/HDPE/GI pipe. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Transportation machine/Micro Tunnelling through Horizontal directional drilling (HDD) machine with accessories including handling of stores materials, preparation of sites, boring and laying of DWC/HDPE/GI pipes for crossing of S&T cable at bridges/culverts/track crossing/pucca road crossing. Boring diameter should be at least 110mm & shall be minimum 3 (three) meter below the river bed and minimum 1 m at track/road/pucca road crossing area etc. In case the site doesn't allow to perform as per schedule, written approval must be obtained from at least site in charge officer. The ground level shall be considered ignoring the bank height of the bank of the road. Note: DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after laying of the cables into DWC/HDPE/GI pipe is laid in the bore. Total 2138650.00
Item Breakup - M-Execution of all work as per schedule
Programming Tagging bytaking latitude & longitude by usingIntegrated Locator or similar inExisting/New S&T cable route withDigital mapping through mobileapplication. Provision of soft andhard copy of Digital route plan,Geo tagging Data long with Railwaytrack to cable distance on digitalmapping considering followingconditions; i. Survey of existingunderground cable u s i n g latesttechnology equipment like-CableRoute Tracer and having RTK basedGPS tagging facility using Catalystcorrection SER-CONST-HQ-ENGG/SOUTH EASTERN RLY service capturing depthand location of U/G cables withGNSS coordinates with accuracy, &capturing distance of cable fromfixed structure/nearest track fromfixed structure/ nearest track.Preparation of such cable routeplan by using suitable softwaretools. Report will show l o c a t i o n , d e p t h of underground cables, anddistance from fixed structure/mastwith suitable intervals as decidedby Railway. Data to be handed overto railway after survey are: - (i)Soft copy/ Coordinates acquired asper the Railway requirement insuitable USB. (ii) Hard copy ofcable route showing depth,Location (coordinates), distancefrom fixed structure, as decided byRailway representative, in 01Tracing & 02 copies of Final Paperprint. ii. S&T cable route locating byGeo Tagging per Route Km ofTrench for signalling cable &Telecom cable etc, should b e withaccuracy, with Minimum depth ofcable In trench based on GroundLevel at that location to beindicated. Data Output should bemapped provided on (.kml) formatwith integrated depth data ofcables mapped. iii. Equipmentutilized should have Utility mappingsoftware used on mobile phone(Mobile phone with Utility mappedsoftware should take data viaBluetooth from both Cable locator &RTK Global Navigation SatelliteSystem receiver with autocorrection service simultaneously toprovide integrated data output). iv.Additional map required with Cabledistanc from nearest Track to beincluded and provided as hard copymap with G c o o r d i n a t e s of cablementioned. Cable Join locations tobe indicated in Route Map. v.Separate colour code to be used fordifferen trench for S&T cables, ifapplicable. vi. In Route Map, GeoTagging may be placed a aninterval distance of 20 metre foapproximate straight path. Fortrack crossing diversion, culvert,jointing SER-CONST-HQ-ENGG/SOUTH EASTERN RLY locations, interva distance shall be less than 20Mtrs or as pesite condition. vii- Data output tobe provided on: 1. USB 2. Hardcopy print Training on Geo -Taggingof
cable SupplyRouteof GNSSto be included. based cable Numbers 1.00 1147194.23 1147194.23 routetracer kit with receiver with built inmount for GNSS receiver, 12W orhigher power transmitter with >=130V Voltage boost, s u i t a b l e fordetecting & mapping undergroundcables with accuracy up to 25 cm,with c u r r e n t direction up/downarrows. Supply shall include locating receiver with RTK receiver powered by locator receiver,transmitter, compatible dual Bluetooth android phone, mobile application pre-installed in android device with 5 years subscription & PC database software access fordirect map generation & downloadincluding depth d a t a , 5 years subscription for GNSS correctionservice & standard accessories, perspecification attached. Make/Model:Rycom Pathfinder PLDL Routelocator with Trimble DA2 GNSSreceiver or similar. Inspection by RITES. Note-1: Item should be compatible to execute with item no.1 above. Note-2: Authorization MOU from OEM/Authorized Indian representative of OEM of underground cable locating and GNSS Mapping tools. In case OEM is located outside India it should have authorized training, repair and service center facility in India certificate should be provided. Hardware and software should provide should not have malicious code. The OEM or there authorized presentative shall have service facility in India. Self -declaration of OEM having service facility in India or service center authorization letter to it's representative in Total 1899949.73
Item Breakup - N-Execution of all work as per schedule
Supply of Steel Apparatus Numbers case Full height as per Drawing No. SK/Drg./OL/SER /198 or latest with E type lock . E-type lock & their key ward No. will be decided by site engineer as per Specification No. IRS: S- 10/78 with Rev. 8 or latest. Supply of Hylam sheets is not covered under this scope. This includes supply of one key & handle for each four Apparatus Case or minimum one.
Supply of Steel apparatus Numbers case (Half) type as per Drawing No. RE/S&T/ALD/SK/ 220/82 Alt.A and 221/82 with Alt. B or latest with E type lock. E type & their key ward No. will be decided by site engineer as per Specification No. IRS:S10/78 with Rev. 8 or latest. This includes one key & handle for each four Apparatus Case or minimum one.
Supply of Steel Apparatus Numbers Case (Quarter) as per Drawing No. RE/S&T/ALD/SK/227/ 82 or latest with E type lock. E type lock & key ward no. will be decided by site engineer as per Specification No. IRS:S- 10/78 with Rev. 8 or latest. This includes one key & handle for each four Apparatus Case or minimum one
Supply of Earth Electrode as Set per Drawing No. 19-D6 of SEM2021 or latest. GI pipe confirming to IS:1239 or latest of 3.17 mm thickness, minimum 2.5 m long, 50.8 mm diameter, 4.76 mm diameter drilled holes staggered at distance of 152.4 mm.
Supply of HDPE pipe as per Kilometre Specification No. RDSO/SPN/TC/45/2013 Rev- 2.0 or latest with OD/ID of size 50mm/42mm with suitable couplers, plugs, end caps, spacer, T band etc. as required during execution at the site.
Supply of Point Junction Box Numbers with angle size 50x50x6x100 mm & without PBT terminal for point machine as per approved drawing. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of Thermo-shrink Numbers jointing (TSF) kits for jointing underground Quad cable of size 0.9mm/1.4mm diameter conductor for straight/condenser/Y- (Derivation)/Loading Coil/Transformer Joints as per Specification No. IRS- TC77/2012 Rev.3 with Amd. 3.0 or latest.
Supply of 35 mm x 6 mm Metre thick MS Flat Plate Strip as per IS: 226-1975 or latest for earth connection to Signal post, L/Box etc.
Supply of basic material to Numbers construct unit Maintenance Free Earth for Single Earth consisting as per Spec. No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/ RDSO/E&B/002 or latest are as under, (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 No. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No. It also includes supply of (i) 35 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter. SER-CONST-HQ-ENGG/SOUTH EASTERN RLY
Supply of 20 Pair CT box Numbers made of 16 SWG CRC sheet with disconnection and reconnection (wago type). The CT Box should be grey colour powder coated with terminal, washer, nut & bolt should be of brass. There shall also be locking arrangement.
Supply of metallic Colour Numbers Light Signal, Multi Unit type Two Aspect complete but without lamp holder, lenses & transformers as per IRS:S- 26/64 or latest and RDSO Drawing No. SA23003 A/M (Adv.) or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post.
Supply of metallic Colour Numbers Light Signal, Multi Unit type Three Aspect complete but without lamp holder, lenses & transformers as per IRS:S- 26/64 or latest and RDSO Drawing No. SA23002 A/M (Adv.) or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post.
Supply of metallic Colour Numbers Light Signal, Multi Unit type Four Aspect complete but without lamp holder, lenses & transformers as per IRS:S- 26/64 or latest and RDSO Drawing No. SA23001 A/M (Adv.) or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post.
Supply of Shunt Signal Numbers Position Light type complete with base, post etc. as per Drg. No.SA- 23840 (Adv.) Alt '1' or latest, S-23203 or latest and Drg. No. 23845(Adv.) or latest for 90 mm dia. mounting socket as per Specification No. IRS: S- 10/78 with Rev. 8 or latest. Total 1207472.00
Item Breakup - O-Execution of all work as per schedule
ISI Marked HDPE pipe Metre 110mm dia conforming to IS.4984 or latest. Made of virgin material and grade of PE63 pressure at 30 degree centigrade PN6 coil type or 6 M t r Length Pipe. Colour: Black. Make: VENUS, Amatron, Apollo, Surya, Finolex or equivalent. Total 481587.50
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril-2022.pdf
ATTACHMENT
AdvanceCorrectionSlipNo1to11_1.pdf
ATTACHMENT
BarChart_1.pdf
ATTACHMENT
STConditions_compressed_1.pdf
ATTACHMENT
ElectricalConditions_1.pdf
ATTACHMENT
16-06-2026e-BGPolicyinEPCGCCPMSPSSAGCPGMSDated16.06.2026.pdf
ATTACHMENT
2026_05_25ForceMajeureClauseFMC.pdf
ATTACHMENT
TD23-2026.pdf
ATTACHMENT
Download all tender documents and submit your bid