Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹49.5 L+₹1.5 L (3.14%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-Finance Being other than Lowest tenderer | |
| 3 | L3₹49.9 L+₹1.9 L (4.04%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L3 | Rejected-Finance Being other than Lowest tenderer | |
| 4 | L4₹50.8 L+₹2.8 L (5.83%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L4 | Rejected-Finance Being other than Lowest tenderer | |
| 5 | L5₹51.1 L+₹3.1 L (6.49%)Rejected-Finance | L5 | Rejected-Finance Being other than Lowest tenderer |
Tender Value
₹48.7 L
EMD Value
₹98,000
Closing Date
18 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col NG Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8462 REPAIR MAINT TO VENTILATION AT VARIOUS UNDERGROND GALLERIES AT JETTY WHARF AT NAVAL DOCKYARD MUMBAI
2022_MES_541511_1
8462/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
31 Oct 2022
28 Jul 2022
20 Aug 2022
4 Aug 2022
18 Aug 2022
11 Aug 2022
28 Jul 2022 - 4 Aug 2022
Amount
Labour only for repair maintenance of ventilation blowers/industrial exhaust fan and control panel incl. cleaning of blower fan, supply and return air duct and drain tap, cleaning & servicing of dampers linkages for free operation, adjustment of belt tension/replacement of same, if required oiling and greasing of blower motor testing functioning of thermostate and sensors complete. Checking/Testing functioning of installation, cleaning of pre filters including replacement of broken and unserviceable filters, repair of worn out connection cable lugs & connectors, replacement of unserviceable electrical accessories of LT pane complete all as directed. Note :- The Electrical accessories i.e voltmeter, amperemeter, single phase preventor, contactors, relays, timers, MCBs and MCCBs, cables as required are measured and paid separately under relavant items here-in-after.
M&L for dismantling electric motor of any make, 3 phase 415V after disconnecting the electric connection of following capacity, opening the motor for rewinding using super enamelled copper wire of suitable gauge to match with the existing winding wire as per manufacturer's design including varnishing & baking, drying and re-assembling the motor, refixing its original location with proper alignment, making electric connection and testing complete including transporting to workshop for rewinding and back to installation after completion of rewinding work complete all as directed.
Supply laying and testing in cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4.0 core laid on wall / ceiling / duct all as directed including taking down old cable complete all as directed. Make of wire : Polycab/ Havells/ Gloster / Plaza Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
All as per Srl Item No. 03 here in before but 35 sq mm 3.5 core
All as per Srl Item No. 03 here in before but 50 sq mm 3.5 core
Labour only for comprehensive day-to-day maintenance of existing soft starter panel for smooth functioning of each ventilation installation blower motor including checkup of control panels wiring and made operational including functional tests of existing blower room temperature and humidity, duct sensor, immersion temperature sensors, humidity sensors, electrical wiring, PCBs, connections for smooth operation, adjustment/ calibration of control relays, meters, sensors and including replacement of defective/ unserviceable electrical spares/accessories with new, replacement of broken/ worn out connection cable, lugs & connectors, repair work of control panel completed by authorised service engineer of OEM and maintain serviceability data of every ventilation air installation in log sheet book per day except Sunday and holiday and furnish the report to Engineer-in-charge. Note : 1. The Electrical accessories i.e.. voltmeter, amperemeter, single phase preventor, contactors, relays, timers, sensors, MCBs and MCCBs, supply cables as required are measured and paid separately under relevant items as "Supply only" here-in-after. 2. Contractor is also responsible for smooth functioning of all air ventilation installation and if any breakdown of any ventilation installation, same will be rectified in minimum period/time for making serviceable complete all as directed.
Supply only in repair of unserviceable 3 phase electronic voltmeter class 1 Make-L&T CAT No WL132010OOOO or equivalent existing make as approved by GE
Supply only in repair of unserviceable 3 phase electronic amperemeter, class 1 Make-L&T CAT No WL131010OOOOor equivalent existing make as approved by GE
Supply only in repair of 3 phase Analogue type Voltmeter of range 0 to 500 V AC class 1 complete all as directed. Make L&T or equivalent existing make as approved by GE
Supply only in repair of unserviceable timer with working pressure of 240 /415 Volt, 50Hz electronic Timer type ST-100 with mounting kit, timing 3-30 secs and also suitable for replacement of ET-100 complete all as directed. Make-L&T CAT No ST80328OOOO or equivalent existing make as approved by GE
Supply only CSXi model digital soft starter in repair of unserviceable existing soft starter suitable for motor with 300% rated starting current 3 wire (Inline connection) or 6 wire (inside Delta Connection) with inbuilt bypass provision and including with all protections remains active during bypass operation of soft starter of essential ventilation air system blower motor capacity 37 KW complete all as specified. Make : L&T Cat No. CSXi-037-41 or equivalent existing make as approved by GE
Supply only CSXi model digital soft starter in repair of unserviceable existing soft starter suitable for motor with 300% rated starting current 3 wire (Inline connection) or 6 wire (inside Delta Connection) with inbuilt bypass provision and including with all protections remains active during bypass operation of soft starter of essential ventilation air system blower motor capacity 30 KW complete all as specified. Make : L&T Cat No. CSXi-030-41or equivalent existing make as approved by GE
Supply only in repair of digital soft starter and repair of unserviceable existing soft starter EMX3 RTD/ Ground Fault Expansion Card of motor soft starter of essential ventilation air system blower motor capacity 37 KW complete all as specified. Make : L&T Cat No. 995-04804-00 or equivalent existing make as approved by GE
Supply only in repair of digital soft starter and repair of unserviceable existing soft starter EMX3 I/O Expansion Card of motor soft starter of essential ventilation air system blower motor capacity 30 KW complete all as specified. Make : L&T Cat No. 995-04803-00 or equivalent existing make as approved by GE
Supply only in repair of Poly -F plus PB classical V- belt size B178 for Air Blower, complete all as directed. Make: Fenner or equivalent existing make as approved by GE
Supply only in repair of V- belt size B168 for Air Blower complete all as directed. Make: Fenner or equivalent existing make as approved by GE
Supply only in repair of V- belt size B158 for Air Blower complete all as directed. Make: Fenner or equivalent existing make as approved by GE
Supply only in repairs Duct temperature sensor complete all as directed. Make : Honeywell Cat No - C7080A3100 or equivalent existing make as approved by GE
Supply only in repairs Air differential pressure switch sensor of Make : Honeywell Cat No - DPS400A or equivalent existing make as approved by GE
Supply only in repairs Combined Room Humidity / Temperature sensor complete all as directed. Make : Honeywell Cat No - H7080B3103 or equivalent existing make as approved by GE
Supply only in repair Power contactor 2 NO + 2 NC , 3TS5022-0A..2-8K, 3 pole 440 volt, 105 Amps suitable for 55 KW motor of Make Siemens or equivalent existing make as approved by GE
Supply and fix in repair of unserviceable nylon mesh pre-filters Box/Flange type with efficiency of 90% down to 10 microns fabricated in size 610mm x 610mm x 50mm of Air Ventilation Plants rooms No 01, 02, 03, 04, 05, 06, 07, 08 and 09 of SBW, CBW and of UG Sub Stations as specified and directed. Make : Dyna Filters/Thermodyne/AAF/Airtech or Equivalent.
Supply only in repair of unserviceable Over Load Relay suitable for any capacity of starter electric panel
Supply only in repair of unserviceable Single phase preventer suitable for any capacity of electric starter panel L&T/ABB or equivalent existing make as approved by GE
Supply only in repair of unserviceable electric motor starter automatic star delta starter capacity suitable for 30/40 KW/ HP motor complete all as directed. Make-L&T cat No SS94366 or equivalent existing make as approved by GE
Supply only in repair of unserviceable electric motor starter automatic star delta starter capacity suitable for 15/20 KW/ HP motor complete all as directed. Make-L&T cat No SS94362 or equivalent existing make as approved by GE
Supply only in repair of unserviceable electric motor starter automatic star delta starter capacity suitable for 22/30 KW/ HP motor complete all as directed. Make-L&T cat No SS94364 or equivalent existing make as approved by GE
Supply only in repair of unserviceable electric motor starter star delta starter contactor AC1, type ML-1.5 with auxiliary contacts 2NO+2NC and coil volt 220V complete all as directed. Make - L&T Cat No SS91851 or equivalent existing make as approved by GE
Supply only in repair of unserviceable electric motor starter star delta starter contactor AC1, type ML-2 with auxiliary contacts 2NO+2NC and coil volt 220V complete all as directed. Make - L&T Cat No SS90701 or equivalent existing make as approved by GE
Supply only in repair of unserviceable electric motor starter star delta starter contactor type ML-4 with auxiliary contacts 2NO+2NC and coil volt 220V complete all as directed. Make - L&T Cat No SS90910 or equivalent existing make as approved by GE
Supply only in repair of unserviceable MCCB 160 Amp 4 Pole 36kA, Thermal magnetic protection OL/SC, confirming to IS/IEC60947-2& IEC 60947-2 including spreader Terminal, internal and external accessories complete for AC Plant electric panel complete all as specified Make - L&T cat No CM92109OON1OG or equivalent in Legrand, Havells, Schneider
Supply only in repair of unserviceable MCCB 125 Amp 4 Pole, 25kA,Thermal magnetic protection OL/SC, confirming to IS/IEC60947-2& IEC 60947-2 including spreader Terminal, internal and external accessories complete for AC Plant electric panel complete all as specified Make - L&T cat No CM90642OOLO or equivalent in Legrand, Havells, Schneider
Supply only in repair of unserviceable MCCB 100 Amp 4 Pole 25kA, Thermal magnetic protection OL/SC, confirming to IS/IEC60947-2& IEC 60947-2 including spreader Terminal, internal and external accessories complete for AC Plant electric panel complete all as specified Make - L&T cat No CM90642OOLO or equivalent in Legrand, Havells, Schneider
Supply only in repair of unserviceable MCCB 63 Amp 16kA, 4 Pole hermal magnetic protection OL/SC, confirming to IS/IEC60947-2& IEC 60947-2 including spreader Terminal, internal and external accessories complete for AC Plant electric panel complete all as specified Make - L&T cat No CM91712OOJOOG or equivalent in Legrand, Havells, Schneider
Supply only in repair of unserviceable pedestal bearings set of two nos (front and rear) bearing size double row type, cylindrical with bearing cat No. NN30211 make SKF of ventilation air plant complete all as specified and directed.
Supply only in repair of unserviceable pedestal bearings set of two nos (front and rear) bearing size double row type, cylindrical with bearing cat No. NN30212 make SKF of ventilation air plant complete all as specified and directed.
Supply only in repair of unserviceable pedestal bearings set of two nos (front and rear) bearing size double row type, cylindrical with bearing cat No. NN30213 make SKF of ventilation air plant complete all as specified and directed.
Supply only in repair of unserviceable pedestal bearings set of two nos (front and rear) bearing size double row type, cylindrical with bearing cat No. NN30216 make SKF of ventilation air plant complete all as specified and directed.
Supply only in repair of unserviceable pedestal bearings set of two nos (front and rear) bearing size double row type, cylindrical with bearing cat No. NN30217 make SKF of ventilation air plant complete all as specified and directed.
Supply only in repair of unserviceable pedestal bearings set of two nos (front and rear) bearing size double row type, cylindrical with bearing cat No. NN30218 make SKF of ventilation air plant complete all as specified and directed.
Supply only in repair of unserviceable pedestal bearings set of two nos (front and rear) bearing size double row type, cylindrical with bearing cat No. NN30219 make SKF of ventilation air plant complete all as specified and directed.
Material & Labour for repair of unserviceable ventilation blower, dismantling after disconnecting all electric connection and opening inspection of unserviceable blower and transporting to workshop for repairing work of blower shaft and blower drum including replacement of broken/damaged blower with new in existing size i.e blower diameter 2340mm, width 2060mm and length 2760mm, Nos of blower fins 12, remetalling of shaft with electric welding, grinding, finishing, polishing and matching with pedestal bearings and blower drum shaft hollow diameter 80mm including replacement of pedestal bearings two nos front and rear of size NN30316 of SKF including transporting back to installation location and refixing, alignment, re-electric connection testing on load after completion of repair work complete all as specified and directed.
Material & Labour for repairing of unserviceable ventilation blower dismantling after disconnecting all electric connection and opening inspection of unserviceable blower and transporting to workshop for repairing work of blower shaft and blower drum including replacement of broken/damaged blower with new in existing size i.e blower diameter 1630mm, width 1260mm and length 1010mm, Nos of blower fins 12, remetalling of shaft with electric welding, grinding, finishing, polishing and matching with pedestal bearings and blower drum shaft hollow diameter 58mm including replacement of pedestal bearings two nos front and rear of size NN30312 of SKF including transporting back to installation location and refixing, alignment, re-electric connection testing on load after completion of repair work complete
Material & Labour for repairing of unserviceable ventilation blower dismantling after disconnecting all electric connection and opening inspection of unserviceable blower and transporting to workshop for repairing work of blower shaft and blower drum including replacement of broken/damaged blower with new in existing size i.e blower diameter, 2650mm, width 2180mm and length 1830mm, Nos of blower fins 12, remetalling of shaft with electric welding, grinding, finishing, polishing and matching with pedestal bearings and blower drum shaft hollow diameter 91mm including replacement of pedestal bearings two nos front and rear of size NN30318 of SKF including transporting back to installation location and refixing, alignment, re-electric connection testing on load after completion of repair work complete all as specified and directed.
Material & Labour for repair of unserviceable ventilation blower, dismantling after disconnecting all electric connection and opening inspection of unserviceable blower and transporting to workshop for repairing work of blower shaft and blower drum including replacement of broken/damaged blower with new in existing size i.e blower diameter 2340mm, width 1700mm and length 1530mm, Nos of blower fins 12, remetalling of shaft with electric welding, grinding, finishing, polishing and matching with pedestal bearings and blower drum shaft hollow diameter 80mm including replacement of pedestal bearings two nos front and rear of size NN30315 of SKF including transporting back to installation location and refixing, alignment, re-electric connection testing on load after completion of repair work complete all as specified and directed.
Material & Labour for repair of unserviceable ventilation blower, dismantling after disconnecting all electric connection and opening inspection of unserviceable blower and transporting to workshop for repairing work of blower shaft and blower drum including replacement of broken/damaged blower with new in existing size i.e blower diameter 1800mm, width 1510mm and length 1410mm, Nos of blower fins 12, remetalling of shaft with electric welding, grinding, finishing, polishing and matching with pedestal bearings and blower drum shaft hollow diameter 65mm including replacement of pedestal bearings two nos front and rear of size NN3013 of SKF including transporting back to installation location and refixing, alignment, re-electric connection testing on load after completion of repair work complete all as specified and directed.
Material & Labour for repair of unserviceable ventilation blower, dismantling after disconnecting all electric connection and opening inspection of unserviceable blower and transporting to workshop for repairing work of blower shaft and blower drum including replacement of broken/damaged blower with new in existing size i.e blower diameter 1940mm, width 1530mm and length 1420mm, Nos of blower fins 12, remetalling of shaft with electric welding, grinding, finishing, polishing and matching with pedestal bearings and blower drum shaft hollow diameter 70mm including replacement of pedestal bearings two nos front and rear of size NN30314 of SKF including transporting back to installation location and refixing, alignment, re-electric connection testing on load after completion of repair work complete all as specified and directed.
Material & Labour for painting of ventilation blowers/industrial exhaust fan and control panel with super enamelled paint after scraping with wire brush and emery paper of old painting layer incl. cleaning of blower fan and drain tap, cleaning & servicing of dampers linkages for free operation of ventilation air plant complete all as specified and directed.
cooltech engineering services
M/S SOMANATH ENTERPRISES
shakti engineering and electrical works
georson constructions
elite enterprises
shubham construction
United Engineers and Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .