| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84,500Accepted-AOC GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹85,700+₹1,200 (1.42%)Rejected-Finance | L2 | Rejected-Finance Financially Rejected | |
| 3 | L3₹87,740+₹3,240 (3.83%)Rejected-Finance | L3 | Rejected-Finance Financially Rejected |
| Sl No | Description | Qty | Unit | GLYPTIC L1 | Greentech Solution L3 | Integrated Engineering Solutions L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Intelligent Addressable multisensor detector with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base as required. (Approval standards:VdS & EN54 Standard (Approved Make: Siemens as per exsisting panel). | 8 | Nos | 5,900 ₹47,200 Lowest | 6,000 ₹48,000 | 5,950 ₹47,600 |
| 2.00 | .Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Siemens as per exsisting panel). | 1 | No | 9,800 ₹9,800 Lowest | 10,000 ₹10,000 | 9,900 ₹9,900 |
| 3.00 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Approved Make: Siemens as per exsisting panel). | 1 | No. | 19,000 ₹19,000 Lowest | 19,500 ₹19,500 | 19,300 ₹19,300 |
| 4.00 | Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc (Approved Make: Siemens as per exsisting panel). | 4 | Nos | 250 ₹1,000 Lowest | 310 ₹1,240 | 275 ₹1,100 |
| 5.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded Copper Cable (For Loop) (Make. Finolex / KEI ) with 20 mm NB PVC rigid conduit pipe(Make: Precisson-Medium) on the surface of the wall. | 60 | Mtrs. | 125 ₹7,500 Lowest | 150 ₹9,000 | 130 ₹7,800 |
| 6.00NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. | ||||||
| 7.00TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. | ||||||
| 8.00TERMS & CONDITIONS :- | ||||||
| 9.00The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules | ||||||
| 10.00Defect Liabibility Period 1 (One) year | ||||||
Tender Value
₹85,000
EMD Value
₹1,700
Closing Date
4 Jul 2025, 12:00 pmClosed
Exe. Engr.-I, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
Aircondi. work with allied EI, SITC of UPS System as well as Fire Detection Systems for Estbl. of dedicated four bedded HDU Room from previous ERCP Room, Dept of School of Digestive Liver Diseases at 3rd. floor of SDLD bldg_Fire Detection system
2025_WBPWD_862353_1
WBPWD/EE-I/KSHED/Q24/25-26
Open Tender
FIRE FIGHTING M/R
Item Rate
21 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,700
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
8 Sept 2026
11 Jun 2025
7 Jul 2025
11 Jun 2025
4 Jul 2025
18 Jun 2025
17 Jun 2025
Amount
Supply, Installation,Testing & Commisioning of Intelligent Addressable multisensor detector with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base as required. (Approval standards:VdS & EN54 Standard (Approved Make: Siemens as per exsisting panel).
.Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Siemens as per exsisting panel).
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Approved Make: Siemens as per exsisting panel).
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc (Approved Make: Siemens as per exsisting panel).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded Copper Cable (For Loop) (Make. Finolex / KEI ) with 20 mm NB PVC rigid conduit pipe(Make: Precisson-Medium) on the surface of the wall.
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.
TERMS & CONDITIONS :-
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
Integrated Engineering Solutions (BID ID -6626058)
Greentech Solution (BID ID -6626096)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .