Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.1 LAccepted-AOC HOUSE NO 254P SECTOR 6 ROHTAK OPPOSITE RAJIV GANDHI STADIUM VPO MAKRUALI KALAN 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | ₹12.1 L | 1 | Accepted-AOC Work allotted |
| 2 | 2₹14.2 L+₹2.1 L (17.4%)Rejected-Finance | ₹14.2 L+₹2.1 L (17.4%) | 2 | Rejected-Finance Not lowest |
| 3 | 3₹14.7 L+₹2.6 L (21.8%)Rejected-Finance | ₹14.7 L+₹2.6 L (21.8%) | 3 | Rejected-Finance Not lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not ok |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not ok |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
8 Feb 2021, 5:00 pmClosed
Execurtive Engineer Provn Divisn PWD BandR Jind
Executive Engineer Provn Divisn PWD BandR Jind
Construction of side drain on Ghimana-Behbalpur app. road in Jind Distt. (Road ID 6612)
2021_HRY_156984_1
PWD/JInd/Side drain on Ghimana Behbalpur road
Open Tender
Civil Works
Works
182 days
Jind
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹25,000
Yes
Execurtive Engineer Provn Divisn PWD BandR Jind
9 Jun 2021
19 Jan 2021
9 Feb 2021
19 Jan 2021
8 Feb 2021
19 Jan 2021
29 Jan 2021
Amount
Earth work in excavation in foundations, trenches etc. in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres. (HSR 6.6)
Cement concrete 1:8:16 with stone aggregate 40 mm Nominal sie in foundation and plinth. (HSR 10.28)
Cement concrete 1:6:12 with stone aggregate 40mm nominal size in foundation and plinth. (HSR 10.32)
Cement concrete 1:4:8 with stone aggregate 40 mm nominal size in foundation & plinth. (HSR 10.39)
Cement concrete 1:2:4 with stone aggregate 20mm nominal size in foundation and plinth.(HSR 10.41)
Cement Concrete 1:1:1/2:3 with stone aggregate 20mm nominal size in first storey upto 4 meters above plinth level. (HSR 10.60)
Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. [HSR. 10.82 + 10.95 (a)].
First class brick work laid in cement sand mortar 1:4 in foundation plinth. (HSR 11.4)
Brick on edge or tile flooring laid in cement sand mortar1:4 on 75mm thick cement concrete 1:8:16 and 100mm sand filling and cement pointing 1:2 on top. (HSR 14.23)
12 mm Thick Cement Plaster 1:4 on the rough side of single or half brick wall. (HSR 15.5)
Cement pointing 1:2 deep variety on brick and tile work.(HSR 15.60)
Steel reinforcement TMT bars FE-550/EQR/FE-500 D grade or more for RCC work, where no included in the complete rate or RCC including straightening, bending, binding wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths/storeys/basements etc. (HSR 18.22) Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps, wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Providing, lowering, cutting, jointing and testing RCC pipe Class NP-3 as per IS 458-2003 with Spigot and Socketed joints manufactured with ISI marked Sulphate Resistance Cement as per ISI 12330 with rubber rings ISI marked, antitermite as required at site, into trenches, for all depths and laying out the same to correct alignment, gradients and levels including dressing and trimming and cutting of concrete beds and sides of trenches, if required, Jointing with rubber rings in trenches and jointing with 1:1½ cement sand mortar and with end dowels filled with 1:1½ cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in HSR item No. 29.38,29.44,29.45 & 29.46 including cartage, loading and unloading complete in all respects. (HSR 29.96-ix) 600mm dia
Narender Koshik, Contractor
The Ved Ashri Gate Pindara Ghati Coop LandC Society Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .