Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹12.5 L+₹1.3 L (11.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹13.5 L+₹2.3 L (20.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹15.1 L+₹3.9 L (35.1%)Rejected-Finance LAMBA LINE PB NO 414 JUNGLIGHAT PO PORT BLAIR A N 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Other than lowest |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
14 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I)866EWS CARNICOBAR
GE(I)866EWS CARNICOBAR
SPL REPAIR TO CERTAIN SANIARY BLOCK AT AF STATION CARNICOBAR
2021_MES_468827_1
852121-22/E8
Open Tender
Civil Works
Item Rate
180 days
AREA UNDER GE(I)866EWS CARNICOBAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE(I)866EWS
₹28,000
Yes
18 Oct 2021
17 Aug 2021
20 Sept 2021
18 Aug 2021
14 Sept 2021
31 Aug 2021
60 days
Amount
Dismantling floor,hearth or wall tiling inlcuding cement mortar bedding ( but not backing ) removing to serviceable tiles to store and rubbish of the premises etc complete all as specified.
Taking down chowkats or frames with shutter’s (without taking off shutter’s from frame) not exc 1.50 sqm each all as specified and directed.
Taking down chowkats or frames with shutter’s (without taking off shutter’s from frame) exc 1.50 Sqm & nxc 4.00 Sqm each all as specified and directed.
Taking down cement plaster on brick or concrete suraface or stone wall et. Including racking out joints, hacking for key, scrubbing down with water etc. all as directed by Engineer in Charge.
M&L for rendering in cement mortar (1:4) on fair face of wall, finished fair & even without using extra cement complete all as specified
Demolition of PCC block masonry built in cement mortar including all quions, arches, pillars etc. but excluding aslar fcing, dressed stone works, precast concrete articles etc complete all as directed by Engineer in Charge.
M&L for 1st quality Non Skid ceramic tiles 7 to 8 mm thick, coloured (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM (1:6) complete all as specifeid and directed.
S&F aluminium frames for doors, windows, ventilators with one or more rebates including joining joining cleats for fixing etc complete all as specified and as directed.
S&F anodised aluminium window and ventilator shutter, side hung type type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleat, glazing clips, rubber neoprene packing, anodised aluminium snap beading, scews anodised aluminium fittings such as peg stay 150mm long (01 No), hinges type B-21 100mm long (02 No) suitable handle (01 No) complete all as specified and as directed.
S&F aluminium anodised "Deco" grill, DG 102, 100 x 10 mm x 7 mm thick, approved design for windows/ventilators with and including F/U channel complete all as specified and directed.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of operature 1.40mm and fixed with aluminium wire staples complete all as specified and as directed.
S&F sheet glass 5.5 mm thick orinary quality and glazing with oil putty in square not exc 0.5sqm in each pane complete all as specifed & directed by Engineer in Charge.
S&F excruded aluminium alloy handles, fabricated type anidised 150 mm complete all as specified
M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection & paving , finished even and mooth wijtout using etra cement all as pecified & directed by Engneer in Charge
Demolition of PCC in any description and in any position not otherwise specifically provided for complee all as directed by Engineer in Charge.
M&L for precast cement concretein (1:3:6) type C1 (using 20mm graded stone aggregate) block masonry, exceeding 10cm in width and not exceeding 20cm , built in cment mortar (1:6) complete all as specified & directed by Engineer in Charge.
M&L for PVC door frame of size 50x47mm made out of 5mm thick plain coloured PVC sheet , reinforced with MS square conduit complete all as specified & directed by Engineer in Charge.
M&L for facory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & botto rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain comlour PVC sheets for top rails, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain comlour PVC sheet to be fitted in the MS frame welded / sealed to the stiles, rails with suitable PVC sheet beading, aand jointed together with solvent cement, supplying & fixing in the frme at site all as specified & directed by Engineer in Charge.
S&F alumnium anodised barrel tower bolts of excruded section , size 100mm complete all as specified & directed by Engineer in Charge.
S&F butt hinges, medium weight cold rolled mild steel, size 100mm ISI marked complete all as specified
Taking down old GI tubing and connection 15mm dia complete all as directed by Engineer in Charge.
Taking down old GI tubing and connection 20 mm dia complete all as directed by Engineer in Charge.
S&F in repair concealed stop cock 15mm bore chromium plated cast copper alloy with long shank and cup (Concealed type) all as specified & Directed by Engineer in Charge.
M&L for GI pipe medium grade 15mm dia with all fittings and fixed to wall and ceiling or laid in floors all as specified & directed by Engineer in Charge.
M&L for GI pipe medium grade 20mm dia with all fittings and fixed to wall and ceiling or laid in floors all as specified & directed by Engineer in Charge.
M&L for vitreous china wash down water closet pan (Pedestal pattern) size 55x400mm but including brackets, coupling and waste pipe complete all as specified
M&L for vitreous china squatting pan, 'Orrisa Pattern', size 580x440mm white, with integeral foot rest ( excluding flushing cistern and flush pipe) complete all as specified & directed by Engineer in Charge.
Supply only PVC valve less, syphonic action type flushing cister low level, white with inlet, ball valve, float and handle including brackets , capacity 10 Ltr complete all as specified & directed by Engineer in Charge.
Supply, fix in repair vitreous china white wash hand basin with pedestal type , size 550x400mm excluding taps, waste , chain and plugs and porcelain stopper but including brackets, cutting for and pinning in ends of brackets complete all as specified & directed by Engineer in Charge.
Supply only Pillar tap ,cast copper alloy with capston heads , chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shank and flynut, screwed for iron pipe of 15mm complete all as specified & directed by Engineer in charge.
S&F bib taps, cast copper alloy with crutch or butter handle, screwed down , screwed for iron pipe of 15mm size or for brass ferrul and fixed , chromium plated fancy type long body complete all as specified & directed by Engineer in Charge.
S&F angle valve , cast copper alloy with crutch or butter handle, screwed down , screwed for iron pipe of 15mm size or for brass ferrul and fixed , chromium plated fancy type long body complete all as specified & directed by Engineer in Charge.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall , including socket, bends, elbow etc.complete all as specified and as directed.
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including socket, bends, elbow etc..complete all as specified and as directed.
Supply, fix in repair waste coupling of PTMT (Half or full threaded) minimum weight 32 grass to 45 gramm complete all as specified
M&L for PTMT connection suitable for 15mm iron pipe of length 600mm complete all as specified.
S&F in repair cast copper alloy chromium plated shower rose with or without swival joints, any size, including fixing to steel pipe or union, 125mm size complete all as specified & directed by Engineer in Charge.
M&L for preparation of old decorated brick/concrete plastered/un-plastered surfaces of walls, pillars, cornices including brooming down and one coat of oil bound distemper (oil emulsion) of any tint all as directed by Engineer in Charge
S&F in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
M&l for TMT bars 8 to10mm da and over ,cut to length, bent to shape required, nluding cranking, bending spirally for hooping for colmn, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer in Charge
S&F in repair SS grating 75mm dia with waste pipe hole complete all as specified and as directed.
S&F in repair SS grating 110mm dia without waste pipe hole complete all as specified and as directed.
S&F in repair SS grating 75mm dia without waste pipe hole complete all as specified and as directed.
M&L for Granite (of any colour), prepolshed , machine cut ,20mm thick as in cooking plate form, steps, pillars, window cills and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust mixed with admixture of pigment to mactch with the shade of granite all as specified & directed by Engineer in Charge.
S&F stanless steel Jet Sprey suitable for 15mm , of approved makealong with flexible tube of 90cm long complete all as specified
S&F in repair PVC vent cowl 75mm complete all as diected
S&F in repair PVC vent cowl 100 mm complete all as diected
S&F in repair two way angle valve , 15mmdia bore, chromoum plated fancy type , cast copper alloy screwed and with long shank and cu ( cncealed type ) all as directed by Engineer in Charge.
S&F in reair PVC waste pipe 32 mm dia, 90 cm long for WHB complee all as specified & directed by Engineer in Charge.
S&F in repair ,towel rail ,600mm long of PTMT fxed with and including chromoium plated brass svrewes and wooden / plastic cleats (min weight 190 gms) all as directed byEngineer in Charge
S&F in epar stainless steel soap dish (fancy type) approximate size 160x160x90mm complete all as directed by Engineer in Charge.
S&F cast iron floor trap 75mm dia with grating including joining to waste pipe fixed in cement concrete type B1 (1:2:4) using 20mm graded stone aggregate all as specified
S&F cast iron floor trap 100mm dia with grating including joining to waste pipe fixed in cement concrete type B1 (1:2:4) using 20mm graded stone aggregate all as specified
M&L or precast reinforced cment concrete type B1 (1:2:4) using 20mm graded stone aggregate as in manhole /septik tank cover set in cm (1:4) complete all as directed byEngineer in Charge
Taking down point wiring (light, fan, socket,or power) complete,(including fixture and fittings such as switches,ceiling roses, pendants, regulators,sockets, light fittings etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good distrubed surface of walls, floors ,etc. all as specified and directed by Engineer- in-charge.
M&L for point wiring with 1.5 sqmm PVC insulated unsheathed copper conductor multistranded 1100 volts grade single core including one single core 1.5 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor (colour green)drawn through and including PVC casing and capping with all accessories fixed to all type of electrical fittings and earth terminals /earth dolly, complete with PVC rectangular block and rawl plugs fixed to walls / ceilings/ roofs with & including. 3mm thick MS sheet fabricated terminal boxes , flush mounted for mounting of switches , switch socket combination , fan regulator etc as required with 3mm thick hylam sheet top cover all as specified & as directed for the following :- .
One light /Ceiling fan/Exhaust fan point controlled by one Switch and regulator or without regulator.
One 3 pin switch socket 5 Amps independent board.
One 3 pin switch socket 5 Amps same board.
Supply & fixing switch piano 5 Amps, single pole, AC, 230 Volts, flush type, ISI Mark.
Supply & fixing switch socket combination out let 5 pin 5 Amps flush type.
Supply and Fixing Ceiling rose, 3 phase / PVC / polycarbonate, isolated body.
S&F LED light fittings 18 watt, electronic driver ultra slim with excruded poly carbonate defuser for glare fre light distribution including cnnecting up with white twin core flexible cord and taking don od unserviceable light fitting complete all as directed. Make: Havells Lumiline Cat part No-LHEXBQP6IN1W018 or equivalent model in Philips/Crompton/Bajaj as approved.
S&F Mirror LED light fittings 9 watt, astherically designed linear mirror light, provided with high out put MPPA difuser for glare free light able with suitable size and all as specified & directed by Engineer in Charge . Make: Havells Lumiline Cat part No-LHEXARP6PN1W009 or equivalent model in Philips/Crompton/Bajaj as approved.
Taking down carefully existing celling fan and cleaning , greassing and refixing same all as specified and directedby Engr-in-charge.
S&F Stepped type electronic fan regulator flush 120/280 watt, 220 volts,50Hz all as specified.
S & F sheet metal enclosure for MCB, DB, Double door, SPN, 8 ways, 240 Volts with 200 Amps rated bus bar all as specified.
S & F MCB SP 06 Amps to 32 amps , B curve series, 240 volts all as specified.
S& F MCB SPN 6 to 32 Amps, 'C' Curve series ,240 volts all as specified.
Material and laboure XLPE insulated ,armoured,heavy duty , PVC bedded , galvanised steel strip or wire armoured, electric cable with aluminium conductor ,1100 volts grade ,cross sectional area 10 sq mm 2 core all as directed by Engr-in-charge.
Exavation in trenches n.exc.1.5 mtr depth for foundation and getting out for laying of pipes in any type of soil complete all as specified and directedby Engr-in-charge.
Returning filling in including spreading levelling, watering and well ramming in layers not exc. 25cm in any type of soil all as specified and directedby Engr-in-charge.
Removing exavated materials not exc 50 mtr and depositing where directed at a level not execeeding 1.5 mtr above the starting point all as specified and directedby Engr-in-charge.
Supply and laying of DWC Pipe of size 50/38 for cable protection complete with coupler etc. all as specified and directedby Engr-in-charge.
M&L for earthing complete with GI earth plate electrode of size 600mx600mmx6 mm, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr deep below normal ground level, connected to GI earth wire 4 mm by by means of bolts, nuts, check nuts and washers of GI or steel wire and connected to earthing test point / distribution board/equipments or any other indicated situation all as shown in electrical plate No 3 of SSR Part I (2009) and testing on completion including necessary excavation in any type of soil, returning filling, removing of soil and 1.5 mtr length GI medium grade 20mm dia pipe with funnal and wire mesh, PCC chamber of 1:2:4 type B1 using 20 mm grade stone aggregate, 40 mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways pre cast chamber cover with lifiting handle 16mm dia round bars, Gi pipe medium grade15 mm dia for earth wire protaction including charcol, common salt complete all as specified and directed. (Note:- GI earth wire above to 7.5 mtr long shall be measured and paid separetly)
RS ENGINEERING WORK
Bismi Builders & Enterprises
SB ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .