Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC HO MALLAGURI NORTH P O CHAMPASARI PS PRADHAN NAGAR VILL PRADHAN NAGAR DISTT DARJEELING W B PIN 734003 | DARJEELING | WEST BENGAL | 734003 | ₹30.6 L Quoted ₹31.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹33.7 LRejected-Finance | ₹33.7 L | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹34.7 LRejected-Finance | ₹34.7 L | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹35.1 LRejected-Finance | ₹35.1 L | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹35.6 LRejected-Finance | ₹35.6 L | L5 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | M/S STANDARD CONSTRUCTION CO L1 | ADHIKARY CONSTRUCTION L5 | M S ALOK SAHA L4 | SHRI JAYANTA GHOSH L2 | Engineers India L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully old unserviciable copper /aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures, removing materials to store for keeping in safe custody or for taking credit all as directed making good disturbed surfaces of walls with putty, cement and matching the colour of the surface as per existing. | 1,013 | PER POINT | 16 ₹16,208 | 11 ₹11,143 | 17 ₹17,221 | 37 ₹37,481 | 20 ₹20,260 |
| 2.00 | Materials and labour for concealed point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of modular sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting modular switch, sockets, fan regulators etc with modular cover plater for one light / fan point / call bell complete.
NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps | 290 | POINT | 700 ₹2,03,000 | 655 ₹1,89,950 | 720 ₹2,08,800 | 732 ₹2,12,280 | 970 ₹2,81,300 |
| 3.00 | All as per Item Sl No - 02 here in before but for one light point controlled by two 2 way switches complete all as specified and directed. | 4 | PER POINT | 730 ₹2,920 | 725 ₹2,900 | 740 ₹2,960 | 1,030 ₹4,120 | 1,020 ₹4,080 |
| 4.00 | All as per Item Sl No - 02 here in before but for 5 pin, 5/6 A socket point on the independent board complete all as specified and directed. | 60 | PER POINT | 700 ₹42,000 | 695 ₹41,700 | 740 ₹44,400 | 789 ₹47,340 | 960 ₹57,600 |
| 5.00 | All as per Item Sl No - 02 here in before but for 5 pin, 5/6 A socket point on the same board complete all as specified and directed. | 20 | PER POINT | 60 ₹1,200 | 89 ₹1,780 | 280 ₹5,600 | 209 ₹4,180 | 140 ₹2,800 |
| 6.00 | All as per Item Sl No - 02 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete all as specified and directed. | 40 | PER POINT | 800 ₹32,000 | 735 ₹29,400 | 860 ₹34,400 | 834 ₹33,360 | 1,275 ₹51,000 |
| 7.00 | Material and labour for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, in and including PVC casing caping (medium grade) with all fittings & accessories including provn of MS sunk terminal box of minimum size 75 x75 mm fixed flush to wall for mounting switch, socket, fan regulator etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / complete..
NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. | 150 | PER POINT | 615 ₹92,250 | 625 ₹93,750 | 600 ₹90,000 | 532 ₹79,800 | 880 ₹1,32,000 |
| 8.00 | All as per Item Sl No - 07 here in before but for one light point controlled by two 2 way switches complete all as specified and directed. | 2 | PER POINT | 632 ₹1,264 | 675 ₹1,350 | 665 ₹1,330 | 813 ₹1,626 | 920 ₹1,840 |
| 9.00 | All as per Item Sl No - 07 here in before but for 5 pin, 5/6 A socket point on the independent board complete all as specified and directed. | 20 | PER POINT | 608 ₹12,160 | 695 ₹13,900 | 870 ₹17,400 | 532 ₹10,640 | 880 ₹17,600 |
| 10.00 | All as per Item Sl No - 07 here in before but for 5 pin, 5/6 A socket point on the same board complete all as specified and directed. | 10 | PER POINT | 55 ₹550 | 89 ₹890 | 880 ₹8,800 | 121 ₹1,210 | 140 ₹1,400 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
11 Mar 2026, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
REPAIR TO INTERNAL ELECTRIFICATION, SUB MAIN WIRING AND CONNECTED WORKS AT MAP ACCNS OF SEVOKE ROAD MIL STN UNDER GE SEVOKE ROAD
2026_MES_752253_1
8557/SEV OF 2025-26
Open Tender
Civil Works
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUS
8 documents required · 8 mandatory
₹500
GE SEVOKE ROAD
₹94,000
28 Mar 2026
11 Feb 2026
13 Mar 2026
11 Feb 2026
11 Mar 2026
26 Feb 2026
12 Feb 2026 - 20 Feb 2026
Taking down carefully old unserviciable copper /aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures, removing materials to store for keeping in safe custody or for taking credit all as directed making good disturbed surfaces of walls with putty, cement and matching the colour of the surface as per existing.
Materials and labour for concealed point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of modular sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting modular switch, sockets, fan regulators etc with modular cover plater for one light / fan point / call bell complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps
All as per Item Sl No - 02 here in before but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per Item Sl No - 02 here in before but for 5 pin, 5/6 A socket point on the independent board complete all as specified and directed.
All as per Item Sl No - 02 here in before but for 5 pin, 5/6 A socket point on the same board complete all as specified and directed.
All as per Item Sl No - 02 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete all as specified and directed.
Material and labour for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, in and including PVC casing caping (medium grade) with all fittings & accessories including provn of MS sunk terminal box of minimum size 75 x75 mm fixed flush to wall for mounting switch, socket, fan regulator etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / complete.. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per Item Sl No - 07 here in before but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per Item Sl No - 07 here in before but for 5 pin, 5/6 A socket point on the independent board complete all as specified and directed.
All as per Item Sl No - 07 here in before but for 5 pin, 5/6 A socket point on the same board complete all as specified and directed.
All as per Item Sl No - 07 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete all as specified and directed.
Material & labour for wiring in existing conduit with two single core PVC insulated, unsheathed, multistranded copper conductor FRLSH of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor FRLSH of size 1.50 sqmm green in colour as earth lead including provn of MS sunk terminal box of appropriate size suitable for flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete all as specified and directed by Eng-in-charge. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per Item Sl No - 12 here in before but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per Item Sl No - 12 here in before but for 5 pin, 5/6 A socket point on the independent board complete all as specified and directed.
All as per Item Sl No - 12 here in before but for 5 pin, 5/6 A socket point on the same board complete all as specified and directed.
All as per Item Sl No - 12 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete all as specified and directed.
Supply and Fixing ceiling rose, surface PVC 25mmx50mm 3/2 terminals completed all as specified and as directed.
Supply and Fixing in repair lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as directed
Supply and Fixing Bell Ding Dong AC , 230 volts single pole completed all as specified and as directed.
Supply and Fixing Bell buzzer AC , 230 volts completed all as specified and as directed.
Supply and Fixing electronic step regulator, switch type (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed.
Supply and Fixing electronic step regulator, socket type (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed.
Supply and Fixing modular electronic step regulator (speed regulation in 5 steps) 1module type suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete.
Supply and Fixing modular electronic step regulator (speed regulation in 5 steps) 2module type suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete.
Supply and fixing modular switch one way 6/10 Amps 230 volts,1 module all as specified and as directed by the Engineer in charge
Supply and fixing modular bell push 6 Amps 230 volts,2 module all as specified and as directed by the Engineer in charge
Supply and fixing modular switch one way with indicator 16 /20 Amps 230 volts, 2 module all as specified and as directed by the Engineer in charge
Supply and fixing modular switch two way 6 Amps 230 volts,1 module all as specified and as directed by the Engineer in charge
Supply and fixing modular socket 2 in 1, 2/3 pin ,6/10 Amp, 2 module all as specified and as directed by the Engineer in charge.
Supply and fixing modular socket 3 pin, 16/20 Amp, 2 module combined shuttered specified and as directed .
Supply and fixing modular white cover plate with frame 1 module inclusive of inner & outer plate complete all as specified and as directed
Supply and fixing modular white cover plate with frame 2 module inclusive of inner & outer plate complete all as specified and as directed .
Supply and fixing modular white cover plate with frame 3 module inclusive of inner & outer plate complete all as specified and as directed
Supply and fixing modular white cover plate with frame 4 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
Supply and fixing modular white cover plate with frame 6 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
Supply and fixing modular white cover plate with frame 8 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
Supply and fixing modular white cover plate with frame 12 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in charge.
Supply and Fixing modular metal flush box 1/2 module all as directed
Supply and Fixing modular metal flush box 3 module all as directed
Supply and Fixing modular metal flush box 4 module all as directed
Supply and Fixing modular metal flush box 6/8 module all as directed
Supply and Fixing modular metal flush box 12 module all as directed
Taking out existing unserviceable one and supply and fixing new modular switch one way 6/10 Amps 230 volts,1 module all as specified and as directed by the Engineer in charge
Taking out existing unserviceable one and supply and fixing new modular switch one way 6/10 Amps 230 volts,2 module all as specified and as directed by the Engineer in charge
Taking out existing unserviceable one and supply and fixing new modular switch two way 6/10 Amps 230 volts,1 module all as specified and as directed by the Engineer in charge
Taking out existing unserviceable one and supply and fixing new modular bell push switch one way 6 Amps 230 volts,1 module all as specified and as directed by the Engineer in charge
Taking out existing unserviceable one and supply and fixing new modular socket 16/20 Amps 230 volts, 2 module all as specified and as directed by the Engineer in charge
Taking out existing unserviceable one and supply and fixing modular socket 2 in 1, 2/3 pin ,6/10 Amp, 2 module all as specified and as directed by the Engineer in charge.
Supply and fixing PVC GANG BOX complete with SSC 5/6 A complete all as specified and directed
Supply and fixing PVC GANG BOX complete with SSC 6/16 A complete all as specified and directed
Material & labour for removing old rusted sunken metel box from wall and fixing new MS box of size 4x4,4x5,4x6 inch including suitable size hylum sheet 3mm thick (switch,socket and regulators like accessories will measured and paid separately) and making surface good including building material work and painting complete all as directed by Engineer in Charge .
Material & labour for removing old rusted sunken metel box from wall and fixing new MS box of size 4x10 inch including suitable size hylum sheet 3mm thick (switch,socket and regulators like accessories will measured and paid separately) and making surface good including building material work and painting complete all as directed by Engineer in Charge .
Material & labour for removing old rusted sunken metel box from wall and fixing new MS box of size 8x10,6x10,8x8 inch including suitable size hylum sheet 3mm thick (switch,socket and regulators like accessories will measured and paid separately) and making surface good including building material work and painting complete all as directed by Engineer in Charge .
Taking down existing unservisiable FTL light fitting and S&F decorative box type fitting with LED tube 10 watt 2 feet with Aluminium extruded batten luminaire for 230 volt AC complete all as directed by Engineer in Charge
Taking down existing unservisiable FTL light fitting and S&F decorative box type fitting with LED tube 10 watt 2 feet with PVC batten luminaire for 230 volt AC complete all as directed by Engineer in Charge
Taking down existing unserviceable FTL light fitting and S&F decorative batten type fitting with LED light fitting 20 watt 4 feet with Aluminium extruded batten luminaire for 230 volt AC all as directed.
Taking down existing unserviceable FTL light fitting and S&F decorative batten type fitting with LED light fitting 20 watt 4 feet with PVC batten luminaire for 230 volt AC all as directed.
Taking down existing unserviceable light fitting and S & F spot light 8 Watt 220 Volts AC including driver and accessories,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Taking down existing unserviceable light fitting and S & F round/square shape 20 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Taking down existing unserviceable light fitting and S & F round/square shape 15 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Taking down existing unserviceable light fitting and S & F round/square shape 12 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Taking down existing unserviceable light fitting and S & F round/square shape 9/10 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Supply and fixing new LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Taking down existing u/s light fitting and S&F in repair wall fancy light fitting (as per existing size and shape or in equivalent) with E-27 type holder and E-27 15/20watt white/warm colour 230 Volts necessery fixing arrangements complete all as specified and directed.
Taking down existing unserviceable light fitting and supply and fixing picture light upto 12 W and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing energy saving and environmental friendly long life LED security/street Light fittings 35 watts, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover, IP 66 protection, inbuilt driver, connecting with suitable size copper wire, complete all as specified and as directed.
Materials &Labour for GI bracket made out of 25 mm bore medium grade GI Pipe with two sets of clamps grouted in wall with four number of wall fastners , bend to shape all as directed, length of GL Pipe shall not be less than 1.5 meter for fixing of light fitting including taking out old unservicable bracket complete all as specified and as directed.
Supply and fixing in repair MCB distrubution board TPN 4way, double door, IP 43, IK-09, sheet steel, phosphatised,powder coated with 200 amps rated bus-bar,neutral link,earth bar and din rail, 415 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 12 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 8 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 6 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 4 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 2 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and Fixing MCB, SP, 10KA, 230V, "C" curve, 06-32 A, ISI Marked complete all as specified and directed.
Supply and Fixing MCB, DP, 10KA, 415V, "C" curve, 06-32 A, ISI Marked complete all as specified and directed.
Supply and Fixing MCB, TPN, 10KA, 415V, "C" curve, 40/63 Amp, ISI Marked complete all as specified and directed.
Materials &Labour for laminated sheet for existing Distribution Board upto 12Way SPN/ 4Way TPN any size any type including brass screw complete all specified and as directed by Engr-in-Charge.
Materials &Labour for laminated sheet 3mm thick of size 4x4,4x5,4x6 inch including brass screw 04 Nos each sheet and making surface good complete all as specified and directed by Engr-in-Charge.
Materials &Labour for laminated sheet 3mm thick of size 4x8, 4x10, 4x12 inch including brass screw 04 Nos each sheet and making surface good complete all as specified and directed by Engr-in-Charge.
Materials &Labour for laminated sheet 3mm thick of size 8x10,6x10,8x8, 8x12 inch including brass screw 04 Nos each sheet and making surface good complete all as specified and directed by Engr-in-Charge.
Materials &Labour for concealed submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 1.5 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 1.5 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge. (Note: Two runs of 1.5 Sqmm cable and one run of 1.5 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Materials &Labour for concealed submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 2.5 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 2.5 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge. (Note: Two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Materials &Labour for concealed submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 4.0 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 4.0 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge. (Note: Two runs of 4 Sqmm cable and one run of 4 Sqmm earthing cable along with conduit altogether shall be measured as one unit)
Materials &Labour for concealed submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 6.0 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 6.0 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge . (Note: Two runs of 6 Sqmm cable and one run of 6 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Material and labour for submain wiring in existing conduit with two single core PVC insulated, unsheathed, FRLSH stranded copper conductor of size 1.5 Sqmm and one single core PVC insulated, unsheathed solid copper conductor 1.5 Sqmm green in colour as earth lead in existing cancealed PVC conduit with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring from existing concealed conduit complete all as specified and directed by Eng-in-Charge (Note: Two runs of 1.5 Sqmm cable and one run of 1.5 Sqmm earthing cable altogether shall be measured as one unit.)
Material and labour for submain wiring in existing conduit with two single core PVC insulated, unsheathed, FRLSH stranded copper conductor of size 2.5 Sqmm and one single core PVC insulated, unsheathed solid copper conductor 2.5 Sqmm green in colour as earth lead in existing cancealed PVC conduit with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring from existing concealed conduit complete all as specified and directed by Eng-in-Charge (Note: Two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm earthing cable altogether shall be measured as one unit.)
Material and labour for submain wiring in existing conduit with two single core PVC insulated, unsheathed, FRLSH stranded copper conductor of size 4.0 Sqmm and one single core PVC insulated, unsheathed solid copper conductor 4.0 Sqmm green in colour as earth lead in existing cancealed PVC conduit with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring from existing concealed conduit complete all as specified and directed by Eng-in-Charge (Note: Two runs of 4 Sqmm cable and one run of 4 Sqmm earthing cable altogether shall be measured as one unit.)
Material and labour for submain wiring in existing conduit with two single core PVC insulated, unsheathed, FRLSH stranded copper conductor of size 6.0 Sqmm and one single core PVC insulated, unsheathed solid copper conductor 6.0 Sqmm green in colour as earth lead in existing cancealed PVC conduit with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring from existing concealed conduit complete all as specified and directed by Eng-in-Charge (Note: Two runs of 6 Sqmm cable and one run of 6 Sqmm earthing cable altogether shall be measured as one unit.)
Material and labour for submain wiring with and including PVC casing caping with two single core PVC insulated, FRLSH unsheathed, stranded copper conductor of size 1.5 Sqmm one single core PVC insulated, FRLSH unsheathed solid copper conductor 1.5 Sqmm and green in colour as earth lead with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring complete all as specified and directed (Note: Two runs of 1.5 Sqmm cable and one run of 1.5 Sqmm earthing cable along with casing caping altogether shall be measured as one unit.)
Material and labour for submain wiring with and including PVC casing caping with two single core PVC insulated, FRLSH unsheathed, stranded copper conductor of size 2.5 Sqmm one single core PVC insulated, FRLSH unsheathed solid copper conductor 2.5 Sqmm and green in colour as earth lead with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring complete all as specified and directed (Note: Two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm earthing cable along with casing caping altogether shall be measured as one unit.)
Material and labour for submain wiring with and including PVC casing caping with two single core PVC insulated, FRLSH unsheathed, stranded copper conductor of size 4 Sqmm one single core PVC insulated, FRLSH unsheathed solid copper conductor 4 Sqmm and green in colour as earth lead with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring complete all as specified and directed (Note: Two runs of 4 Sqmm cable and one run of 4 Sqmm earthing cable along with casing caping altogether shall be measured as one unit.)
Material and labour for submain wiring with and including PVC casing caping with two single core PVC insulated, FRLSH unsheathed, stranded copper conductor of size 6 Sqmm one single core PVC insulated, FRLSH unsheathed solid copper conductor 6 Sqmm and green in colour as earth lead with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring complete all as specified and directed (Note: Two runs of 6 Sqmm cable and one run of 6 Sqmm earthing cable along with casing caping altogether shall be measured as one unit.)
S&F in repair plug top 3 pin 15 amps ISI marked complete all as directed
S&F in repair plug top 3 pin 5 amps ISI marked complete all as directed
Materials and labour for aluminium strip 25x3 mm with saddles and fixing screws etc for roof conductors and down conductors above ground in multystoried buildings including necessary scaffolding and safty equipmenta completer all as specified and as directed
Materials and labour for porcelain insulator suitable for fixing earthing strip to the wall / floor etc all as specified and as directed
Materials and labour for test point terminal block with cover made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw all as specified and directed
Taking down ceiling fans/exhaust fan of any size,dismantling blades and removing fan and blades to MES store complete all as specified and directed.
Materials and labour for cleaning of existing LT Panels, busbar from ground to top (G + 4&5) of MAP blocks including lift equipment room and checking of earthing, removing of waste materials/debris from inside the electric equipment areas (from ground to top) as and when directed by Engineer-in-Charge and clean with suitable chemical & submit feedback form complete all in specified & as directed by Engr-in-Charge.
Labour only for checking of switch boards ( light/power) in the each MAP qtr (MAP ORs/JCOs/Offrs) as and when directed and submit details of unserviceable lights, switch/socket, wiring etc to the Engineer-in-Charge.
Material and labour for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 25 X 4mm dia GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed. Note: The earth resistance value shall be less than 3 Ohm and test report shall be submitted to the department.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_842553.xls
BOQ • 1.37 MB
TENDERDOCUMENTS8557.pdf
Tender Documents • 1.22 MB
Download all tender documents and submit your bid