Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC SCO 1785 DEEP COMPLEX HALLOMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | CHANDIGARH | L1 | Accepted-AOC L-1 | |
| 2 | L2₹31.1 L+₹65,907.04 (2.17%)Rejected-Finance 108 A MADANGIR NEW DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | L2 | Rejected-Finance L2 | |
| 3 | L3₹36.7 L+₹6.3 L (20.5%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹39.3 L+₹8.8 L (29.1%)Rejected-Finance NO 3 AASHIRWAD APARTMENTS 11 BURKIT ROAD T NAGAR CHENNAI TAMILNADU 600017 UDYAM TN 02 0007200 | CHENNAI | TAMIL NADU | 600017 | L4 | Rejected-Finance L4 | |
| 5 | L5₹39.3 L+₹8.8 L (29.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹74,064
Closing Date
18 Jun 2020, 6:00 pmClosed
AGM (ENGG-E)
AAI, JAIPUR AIRPORT, JAIPUR
Provision of Cold Storage Room for Cargo Building at Jaipur Airport
2020_AAI_50207_1
AAI/JPR/ENGG(E)/W-104/2020-21
Open Tender
Electrical Works
Item Rate
90 days
JAIPUR AIRPORT
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,120
AAI REVENUE COLLECTION A/C NO. 708300300980020
₹74,064
1 Sept 2020
10 Jun 2020
26 Jun 2020
10 Jun 2020
18 Jun 2020
10 Jun 2020
10 Jun 2020 - 14 Jun 2020
Amount
Design, fabrication, supply, installation, testing and commissioning of Combo Cold Storage Room (L- 4.00 mtr x W- 4.00 mtr x H- 3.00 mtr) consisting of Chiller Room (L- 2.25 mtr x W- 4.00 mtr x H- 3.00 mtr) and Freezer Room (L- 1.75 mtr x W- 4.00 mtr x H- 3.00 mtr) as per actual site conditions. The Chiller Room should be suitable to maintain inside temperature range +2°C to +15°C on 48°C ambient temperature by providing one number air cooled chilling unit, 15000BTU/Hr (nominal) Scroll/ Rotary/ Reciprocating Compressor, green gas (R-404a, 407a, 134a etc.),evaporating (indoor) unit, individual control panel unit etc. complete as required. The Freezer Room should be maintain inside temperature range -25°C to +0°C on 48°C ambient temperature by providing one number air cooled 8000BTU/Hr (nominal) Scroll/ Rotary/ Reciprocating Compressor, green gas (R-404a, 407a, 134a etc.) evaporating (indoor) unit, individual control panel unit etc. complete as required. The Chiller Room is to be fabricated with 60 mm thickness of PUF panel covered with 0.51 mm (24 SWG) Stainless Steel (SS 304) on both sides and Freezer Room with 100 mm thickness of PUF panel covered with 0.51 mm (24 SWG), GI antiskid/ chequred plate flooring, suitable installation/ fixing arrangement for indoor & outdoor units, minor civil works, wiring, all other components/ accessories etc. suitable for operation on 415/230V, 50Hz etc. complete as required.
Design, fabrication, supply, installation, testing and commissioning of Combo Cold Storage Room (L- 5.00 mtr x W- 3.00 mtr x H- 3.00 mtr) consisting of Chiller Room (L- 3.00 mtr x W- 3.00 mtr x H- 3.00 mtr) and Freezer Room (L- 2.00 mtr x W- 3.00 mtr x H- 3.00 mtr) as per actual site conditions. The Chiller Room should be suitable to maintain inside temperature range +2°C to +15°C on 48°C ambient temperature by providing one number air cooled chilling unit, 15000BTU/Hr (nominal) Scroll/ Rotary/ Reciprocating Compressor, green gas (R-404a, 407a, 134a etc.),evaporating (indoor) unit, individual control panel unit etc. complete as required. The Freezer Room should be maintain inside temperature range -25°C to +0°C on 48°C ambient temperature by providing one number air cooled 8000BTU/Hr (nominal) Scroll/ Rotary/ Reciprocating Compressor, green gas (R-404a, 407a, 134a etc.) evaporating (indoor) unit, individual control panel unit etc. complete as required. The Chiller Room is to be fabricated with 60 mm thickness of PUF panel covered with 0.51 mm (24 SWG) Stainless Steel (SS 304) on both sides and Freezer Room with 100 mm thickness of PUF panel covered with 0.51 mm (24 SWG), GI antiskid/ chequred plate flooring, suitable installation/ fixing arrangement for indoor & outdoor units, minor civil works, wiring, all other components/ accessories etc. suitable for operation on 415/230V, 50Hz etc. complete as required.
Supply, installation, testing and commissioning of interconnecting copper refrigerant pipes of 12.7 mm (OD 1/2 Inch), 0.80 mm wall thickness & 9.50 mm (OD 3/8 inch), 0.80 mm wall thickness with 13mm insulation or OEM's standard along with 4C x 4.00 sqmm FRLS PVC copper conductor cables between freezer's indoor and outdoor units duly insulated with closed cell elastomeric nitrile rubber type tubular insulation of nominal thickness as per OEM's standard including fixing arrangements etc. as per site requirement.
Supply, installation, testing and commissioning of interconnecting copper refrigerant pipes of 15.9 mm (OD 5/8 inch), 1.00 mm wall thickness & 9.5 mm (OD 3/8 Inch), 0.80 mm wall thickness with 13mm insulation or OEM's standard along with 3C x 4.00 sqmm FRLS PVC copper conductor cables between chiller's indoor and outdoor units duly insulated with closed cell elastomeric nitrile rubber type tubular insulation of nominal thickness as per OEM's standard including fixing arrangements etc. as per site requirement.
Supply, installation, testing and commissioning of 25 mm hard PVC drain piping complete with fittings, supports, valve and 6 mm thick closed nitrile rubber foam insulation complete as required.
CLIMATROL CORPORATION
Metro International
ASVA COOL SOLUTIONS PVT LTD
Superior Aircon Pvt. Ltd.
Airtech Cooling Process Pvt Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .