Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹24.3 L+₹23,324.90 (0.97%)Rejected-AOC | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹26.0 L+₹2.0 L (8.10%)Rejected-AOC NO 45 5TH CROSS MALLAPPA LAYOUT BABUSAPALYA KALYAN NAGAR BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-AOC Higher bid value | |
| 4 | L4₹26.8 L+₹2.7 L (11.3%)Rejected-AOC | L4 | Rejected-AOC Higher bid value | |
| 5 | L5₹28.0 L+₹3.9 L (16.1%)Rejected-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L5 | Rejected-AOC Higher bid value |
Tender Value
Refer Docs
EMD Value
₹59,000
Closing Date
18 Oct 2022, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
SPECIAL REPAIR TO ROOF AT VARIOUS LOCATIONS IN HOSPITAL AREA (OTM) AND PROVN OF FLAME PROOF LIGHT FITTING AND CONNECTED ITEMS FOR VARIOUS OXYGEN MANIFOLD ROOMS (OXYGEN PLANT MED DIV AND ART CENTRE) AT CHAF BANGALORE
2022_MES_553695_1
8938/GE/62
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹59,000
Yes
25 Nov 2022
22 Sept 2022
20 Oct 2022
22 Sept 2022
18 Oct 2022
4 Oct 2022
23 Sept 2022 - 28 Sept 2022
Amount
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings dressed stone work and precast concrete articles etc complete all as specified and directed.
Demolition of cemet concrete any description and in any position not otherwise specifically provided for etc complete all as specified and directed.
Demolition of cemet concrete padding or mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) etc complete all as specified and directed.
M&L for providing, cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate as in roof kerbs, padding or mud stops, rounded or chamfered on edges etc complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with soild blocks, type C1 (1:3:6) using 20mm graded aggregate exc 10 cm in width and setting in cement mortar (1:6) complete etc complete all as specified and directed.
Supply only liquid water proofing compound
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry (1:3) complete all as specified and directed.
M&L for water proofing treatment on horizontal and vertical surfaces with applying of oil bound bitumen primer @ 0.20 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.0 Kg/Sqm reinforced with non woven polyester matt weighing not less than 160 grm/Sqm having softening point not less than 150 degree centigrade, having tensile strength of 650 N/5cm and 350 N/5cm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180N by torch on application including minimum 10cm side over lap and 15 cm end lap applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.20 Kg/Sqm finished with solar reflective bituminus aluminium paint @ 0.10 kg per sqm including removing of existing water proofing treatment of any description and cleaning with roof surface with wire brush and water complete all as specified and directed by Engr in charge.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubing down with water etc complete all as specified and as directed
M&L for rendering 15 mm thick Cement plaster in CM 1 :4, (5 mm thick with WP compound/liquid over 10 mm thick cement plaster in two layers) on fair faces of brick work or concrete surfaces with water proofing compound @ 200ml per 50kg of cement or as per manufacturer's instruction etc finished even and fair complete all as specified and as directed.(Note : WPC shall be measured and paid separately as supply only under relevent item)
M&L for rendering 10mm thick in cement mortar 1:3 on roof padding finished even and fair with approved water proofing compound @ 200ml per 50kg of cement or as per manufacturer's instruction all as specified and as directed.(Note : WPC shall be measured and paid separately as supply only under relevent item)
S&F tubing,medium grade,15mm bore with all fittings and fixed complete to walls and ceiling or laid in floors including testing complete all as specified and directed Note : Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
S&F tubing,medium grade,20mm bore with all fittings and fixed complete to walls and ceiling or laid in floors including testing complete all as specified and directed. Note : Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
S&F tubing,medium grade, 25mm bore with all fittings and fixed complete to walls and ceiling or laid in floors including testing complete all as specified and directed Note : Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Taking up or down steel tubing and connections, fittings etc 15mm bore including cleaning for serviceable pipe for re-fixing or removal of unserviceable pipe from site of work complete all as directed. Note : Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Taking up or down steel tubing and connections, fittings etc 20mm bore including cleaning for serviceable pipe for re-fixing or removal of unserviceable pipe from site of work complete all as directed. Note : Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Taking up or down steel tubing and connections, fittings etc 25mm bore including cleaning for serviceable pipe for re-fixing or removal of unserviceable pipe from site of work complete all as directed. Note : Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Refixing 15mm bore steel tubing and connections in new or old position (walls,ceiling, floor etc) including testing complete all as directed.
Refixing 20mm bore steel tubing and connections in new or old position (walls,ceiling, floor etc) including testing complete all as directed.
Refixing 25mm bore steel tubing and connections in new or old position (walls,ceiling, floor etc) including testing complete all as specified and directed.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete all as specified. Note : Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete all as specified. Note : Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or new location position capacity exc 250 & n exc 500 ltr complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or new location position capacity exc 500 & n exc 1000 ltr complete all as specified and directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tank (cylindrical or vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I and dismantling existing water tanks and removing from site all as specified and as directed.
S&F 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical or vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I and dismantling existing water tanks and removing from site all as specified and as directed.
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair Ball brass valves, 20mm bore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed.
Removing building materials (any type) to a distance of 30 Km beyond the lead including in the rates, including loading, unloading and stacking at the destination all as specified and as directed. (Note : All debris shall be removed from MoD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
M&L point wiring for armoury with PVC insulated 1.5 sqmm multistranded bunched copper conductor cable , FRLSH , 1100 volt grade drawn in and surface mountedsteel conduit stove enamelled , black steel conduit not less than less 19 mm dia with and including flame proof bends and elbows , couplers , bell mouth reducer except junction box all as per relevant IS and type tested / approved by CMRI fixed with solid baked distance saddles and elevated MS spacer plate fixed with nettle fold Gl screws along with 1.5 sqmm PVC insulated solid strand copper conductor FRLSH 1100 Volt grade as ECC connected to common earth dolly . ( a ) One light point controlled by one rotary switch / MCB
Supply and fixing LED light fitting 1x40Watt flameproof , CMRI certified recommended for gas / vapour group of IIA & IIIB , Zone 1 & 2 and IP 65 protectionwith die cast aluminum housing with heat resistant toughened glass , with LED tube light fixtures driver , holders , connector etc. Complete with all accessoriesprewired and including connecting up with three core , flexible copper conductor cable with suitable size all as specified and directed
Supply and fixing Switch flame proof rotarytype with termination box inLM6 , 16A , single pole 250V.all as specified and directed
M & L sub main wiring with Two single core PVC insulated cable with copper conductor FRLSH multistranded 1100 volts grade 2x4 sqmm in and including heavy grade steel conduit and its accessories with fixing arrangements on surface , wall , floor or ceiling etc including 2.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed Note : One run of earth continuity conductor , one run of steel conduit and three runs of copper conductor together taken as one length for measuring unit length
Supply and fix sheet metal enclosure double door type for DBS for mounting of MCB for 240V , 4 way with 200 Amps rated Bus bar , single pole & neutral , fixed in repairs complete all as specified and directed
Supply and fix miniature circuit breaker ( MCBs ) SPN , 240 volts , 10KA , 32 Amps c series complete all as specified and directed
Supply and fix miniature circuit breaker ( MCBs ) single pole , 240 volts , 10KA , 6 to 32 Amps C series complete all as specified and directed
C R R CONSTRUCTIONS
M/S Suresh Raju
B5BUILDING SOLUTIONS
G K CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .