Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹4.5 L
EMD Value
₹12,500
Closing Date
2 Jun 2025, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
jyoti
Shifting of 100kVA Transformer at Anandnagar Byahatti plot 1st cross road of ward no.33 of Hubli Division
DMA/2025-26/EL/WORK_INDENT39035
DMA/2025-26/EL/WORK_INDENT39035
Open
Electrical
Electronic Documents, First(One Cover)
DMA City Corporation Hubballi-Dharawada
6 documents required · 6 mandatory
₹500
₹12,500
22 May 2025
22 May 2025
23 May 2025
Shifting of 100kVA Transformer at Anandnagar Byahatti plot 1st cross road of ward no.33 of Hubli Division
Spun Pole Pre-Stressed Tubular Spun Pole - 11 Mtr Long, 500 Kg WL (Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158: 1991
Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr depth (Mechnised Labour)
22.07 Three H Frame without Transformer Seating and
Seating angle support cross arm for 11 Mtr Spun Pole
for 63/100/250/500 kVA (UG Cable) - MS
(Dwg No. BESCOM/GM/QS&S/69 Dtd 24.11.2018) Single Pole M...
4.02 For Three H Frame with Transformer Seating and Seating
angle support cross arm for 11 Mtr Spun Pole up to and
including 250 kVA (UG Cable) (excluding erection of Pole)
Erection of Double Pole Tra...
8.02 Erection of 100 kVA Transformer
Fixing of HT/LT Single Top Support
11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod)
Rabbit ACSR Conductor
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
Stringing of Conductor do - for Rabbit ACSR
15.05 Wiring of 2 Circuits of LT Wiring for for 25/63/100 kVA DTC
to the existing LT protection Kit/Distribution Box via metering
box. (includes fixing of necessary supports like 2 Pin cross
Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr
A) Base concreting For 11 M Spun Pole (1000x1000x150 mm)
B) Pole concreting For 11 M Spun Pole (1000x1000x2500 mm)
Coping for Poles 390 mm all around the pole for an height of 300 mm for Spun Pole(1130x1130x300 mm)
(3.251 mm Dia), Std Wt: 82 Kg/KM
7/10 SWG GI Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM
Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, includin...
HDPE/PLB Pipe 50/42 mm
11 kV, HG Fuse Unit with Solid Core Insulator
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring
11 kV, 200 Amps Single Break GOS
Fixing of GOS including wiring (11 kV Single Break 200 Amps)
Pipe Grounding GI grounding Pipe,B-class,42mm dia,2.5mtr long 3.2mm thick with bolt,nut,GI strips and washer compleete.Minimum weight of GI pipe:7.3kg.
Good Quality well burnt charcoal for grounding purposes packed in non returnable gunny bag of 30 kg each
Good Quality salt for grounding purposes packed in 50kg gunny bag
Rod type of earthing using 40mm dia 3 mtr long M.S rod as ground rod,in earth pit of 300mm width and 3300mm depth and using 50X6 mm flat welded to ground rod as terminal is connected to equipment grou...
Digging of pit for providing GI Pipe type Earthing.
PVC Wire - 120 Sqmm
Al Wt: 32 Kg, Total Wt: 45.5Kg/100 Mtr Coil
Heavy Duty Copper Terminal Long Barrel 120 Sqmm Copper Terminal, Apprx Wt: 64 Gm
PG Clamp Rabbit to Insulated Wire 120 Sqmm
Fixing LT Electronic Tri-Vector Meter 5 Amps, -0.5/1.0 Accuracy Class
Fixing Lightning Arrester Lightning Arrester, Metal oxide,10 kV, 5 kA Polymeric Type with ground disconnector
HT UG Cable 36.01) 95 Sqmm, (54 GI Wires - 2.5 mm Dia) 11 kV, 3 Core, XPLE HTUG Cable with
pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2)
Armouring wires dia and Resistivi...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT cable
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 to 240 Sqmm
LT UG Cable 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per ...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm
Epoxy Terminating Kit (Pothead) suitable
for 1.1 kV, LTUG Cable 3.5 x 225/240/300 Sqmm
Fixing HT Pothead Heat shrinkable Type Terminations
Sand Artificial/Manufacture Sand
Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand)
Ug Cable Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, b...
Refilling Around Cable Refilling available earth around trenches/pipelines cables in layers not exceeding 20 cm in depth compacting each deposited layer by ramming after watering with a lead upto 50 m...
Straight Joint Heat Shrinkable Straight Through Jointing Kit for PILC Cable with Copper Lug & Al Ferrule 3x240 Sqmm
Straight Joint Fixing Heat shrinkable Straight Through Joint 3x185 to 3x240 Sqmm
Releasing RCC/PSC Pole 9 Mtrs, 8 Mtrs Dismanting of Steel/I- Beam 90% of the Pole erection charges
Releasing of 2/4 Pin cross arm with Insulator and Braces fixing
Releasing of V-Shape/Horizontal cross arm including Single Top Support Brace
and Insulator fixing
Releasing GOS Fixing of GOS including wiring (11 kV Single Break 200 Amps)
Releasing of H-Frame for mounting GOS
Releasing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring)
Releasing 1 Circuit of LT Wiring for 250/500 kVA Transformers via metering box.
(includes fixing of necessary supports like 2 Pin cross arm, Spacer etc)
Releasing Wiring of 1 Circuit of LT Wiring for for 25/63/100 kVA DTC to the existing LT protection Kit/ Distribution Box via metering box. (includes fixing of necessary supports like 2 Pin cross arm, ...
Releasing 9 Mtrs RCC Transformer Structure DP 100 KVA & 250 KVA DTC The Consolidated labour charges for 1 to 4 Pole works for Service connection and E&I works. This amount includes all charges includi...
Releasing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring
Lightning Arrester 10 kV, 5 kA Lightning Arrester Polymeric type with
GROUND DISCONNECTOR
Caution/Danger Board ESCOMs SR 2023-24 Page No 368 Item No 68.17
ixing Caution/Danger Board ESCOMs SR 2023-24 Page No 381 Item No 5.15
Anticlimbing Device GI Barbed wire (12 Mtr/Kg) wire Lumpsum ESCOMs SR 2023-24 [Pg.No:340 I.No:4.02]
Fixing Charges Anticlimbing Device GI Barbed wire (12 Mtr/Kg) ESCOMs SR 2023-24 [Pg.No:381 I.No:5.09
32.08 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm))1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip...
Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., ESCOMs SR 2023-24 Page No 389 [23.07]
Cable Covering Tile 125x250x40 mm ESCOMs SR 2023-24 Page No 368 [68.06]
Laying and Jointing: Joining with mud mortor complete Covering cable with Tiles ESCOMs SR 2023-24 Page No 392 [27.01]
Route & Joint indicating slab with MS Anchor rod ESCOMs SR 2023-24 Page No 32 [68.08]
Fixing of Route Joint Indicating Slab ESCOMs SR 2023-24 Page No 56 [27.02]
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
39035.doc
Tender Document • 1.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .