Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC 58 1ST FLOOR PATEL NAGAR BATHINDA | BATHINDA | BATHINDA | PUNJAB | L1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L2₹31.0 L+₹1.2 L (3.92%)Rejected-Finance HOUSE NO 104 WARD NO4 MOHALLA WADHERIAN PATHANKOT GURDASPUR PUNJAB 145001 UDYAM PB 16 0006453 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Higher side quoted amount | |
| 3 | L3₹33.6 L+₹3.8 L (12.9%)Rejected-Finance NH 44 BUILDING COLONY NO 01 SUJANPUR TEH DISTT PATHANKOT PUNJAB 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L3 | Rejected-Finance Higher side quoted amount | |
| 4 | L4₹34.4 L+₹4.6 L (15.6%)Rejected-Finance BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Higher side quoted amount | |
| 5 | L5₹34.8 L+₹5.0 L (16.9%)Rejected-Finance VILL NAYA GUGNAN PO SUJANPUR TEH DISTT PATHANKOT 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L5 | Rejected-Finance Higher side quoted amount |
| Sl No | Description | Qty | Unit | kay gee construction co L6 | OMKAR SHARMA AND CO L7 | GANDOTRA CONSTRUCTION CO L4 | Substantial Const. Co. L5 | M/S RUDRA CONSTRUCTION CO L1 | DABGOTRA BUILDERS L8 | Ambika Construction Co L2 | M/S Raghuvanshi Builders L9 | HARI OM ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Sch 'A' Part-I B/R Portion:-
Surface excavation not exceeding 30 cm deep and average 15cm deep and getting out in soft / loose soil, complete all as specified. | 215 | Sqm | 6 ₹1,290 Lowest | 15 ₹3,225 | 22 ₹4,730 | 20 ₹4,300 | 22 ₹4,730 | 55 ₹11,825 | 50 ₹10,750 | 55 ₹11,825 | 45 ₹9,675 |
| 2.00 | Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point complete all as specified and directed. | 66.09 | Cum | 45 ₹2,974.05 Lowest | 155 ₹10,243.95 | 88 ₹5,815.92 | 50 ₹3,304.5 | 55 ₹3,634.95 | 55 ₹3,634.95 | 150 ₹9,913.5 | 99 ₹6,542.91 | 77 ₹5,088.93 |
| 3.00 | M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate in sub basefor pavment, floor etc. complete all as specified and directed. | 215 | Sqm | 80 ₹17,200 Lowest | 90 ₹19,350 | 222 ₹47,730 | 200 ₹43,000 | 150 ₹32,250 | 105 ₹22,575 | 250 ₹53,750 | 155 ₹33,325 | 299 ₹64,285 |
| 4.00 | M&L for 80 mm thick Machine pressed precast concrete interlocking paver block (glossy finish with red & yellow in colour) with grey cement and pigment of shape and size as approved by GE confirming to IS 15658-2006, M-40 Grade including 50mm thick sand cushion complete all as specified and directed. | 215 | Sqm | 1,585 ₹3,40,775 | 950 ₹2,04,250 | 999 ₹2,14,785 | 900 ₹1,93,500 | 900 ₹1,93,500 | 1,100 ₹2,36,500 | 800 ₹1,72,000 | 1,039 ₹2,23,385 | 701 ₹1,50,715 Lowest |
| 5.00 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in rounded or chamfered on edges in any description complete all as specified and directed. | 1.9 | Cum | 5,500 ₹10,450 | 4,000 ₹7,600 | 6,666 ₹12,665.4 | 4,000 ₹7,600 | 5,000 ₹9,500 | 3,500 ₹6,650 | 5,000 ₹9,500 | 4,000 ₹7,600 | 3,333 ₹6,332.7 Lowest |
| 6.00 | Surface dressing n exc 15 cm deep in any type of soil complete all as specified and directed by Engr-in-Charge. | 140.6 | Sqm | 6 ₹843.6 Lowest | 15 ₹2,109 | 7 ₹984.2 | 10 ₹1,406 | 20 ₹2,812 | 20 ₹2,812 | 50 ₹7,030 | 53 ₹7,451.8 | 55 ₹7,733 |
| 7.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft & loose soil complete all as specified and directed by Engr-in-Charge. | 32 | Cum | 185 ₹5,920 | 350 ₹11,200 | 222 ₹7,104 | 150 ₹4,800 | 250 ₹8,000 | 350 ₹11,200 | 300 ₹9,600 | 125 ₹4,000 Lowest | 199 ₹6,368 |
| 8.00 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling or mass concrete as specified and directed | 6.5 | Cum | 3,500 ₹22,750 | 3,200 ₹20,800 | 2,222 ₹14,443 | 2,000 ₹13,000 Lowest | 3,000 ₹19,500 | 2,900 ₹18,850 | 3,000 ₹19,500 | 2,500 ₹16,250 | 2,666 ₹17,329 |
| 9.00 | M&L for concrete bed to drain pipe in PCC (1:4:8) type C-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 150 mm bore pipe, complete all as specified and directed by Engr-in-Charge. | 48 | RM | 50 ₹2,400 Lowest | 122 ₹5,856 | 77 ₹3,696 | 250 ₹12,000 | 111 ₹5,328 | 55 ₹2,640 | 50 ₹2,400 Lowest | 199 ₹9,552 | 199 ₹9,552 |
| 10.00 | M&L for 150mm bore SGSW pipe grade 'A' laid and jointed complete with collars complete all as specified and directed by Engr-in-Charge. | 50 | RM | 600 ₹30,000 | 500 ₹25,000 | 888 ₹44,400 | 425 ₹21,250 | 400 ₹20,000 Lowest | 400 ₹20,000 Lowest | 500 ₹25,000 | 599 ₹29,950 | 888 ₹44,400 |
Tender Value
Refer Docs
EMD Value
₹82,520
Closing Date
13 Aug 2025, 6:00 pmClosed
GE(WEST)PATHANKOT
GE (WEST) PATHANKOT
PROVN OF 02 X TOILET BLOCK (EACH HAVING 10 X WC, 03 X URINAL POINTS AND 04 X BATH) AT 272 TRANSIT CAMP UNDER GE (WEST) PATHANKOT
2025_MES_720494_1
GE/PKT-33/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (WEST) PATHANKOT
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE(WEST)PATHANKOT
₹82,520
19 Sept 2025
15 Jul 2025
15 Aug 2025
15 Jul 2025
13 Aug 2025
29 Jul 2025
Amount
Sch 'A' Part-I B/R Portion:- Surface excavation not exceeding 30 cm deep and average 15cm deep and getting out in soft / loose soil, complete all as specified.
Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate in sub basefor pavment, floor etc. complete all as specified and directed.
M&L for 80 mm thick Machine pressed precast concrete interlocking paver block (glossy finish with red & yellow in colour) with grey cement and pigment of shape and size as approved by GE confirming to IS 15658-2006, M-40 Grade including 50mm thick sand cushion complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in rounded or chamfered on edges in any description complete all as specified and directed.
Surface dressing n exc 15 cm deep in any type of soil complete all as specified and directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft & loose soil complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling or mass concrete as specified and directed
M&L for concrete bed to drain pipe in PCC (1:4:8) type C-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 150 mm bore pipe, complete all as specified and directed by Engr-in-Charge.
M&L for 150mm bore SGSW pipe grade 'A' laid and jointed complete with collars complete all as specified and directed by Engr-in-Charge.
Returning, Filling in, including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil complete all as specified and directed.
M&L for burnt clay brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for Brickwork in half brick thick wall with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work ,concrete surface of wall finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:6 on other than fair faces of brick work ,concrete surface of wall finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for Providing precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in precast cover slab (for manhole etc incl all use of forms, mould or machine moulds and setting the blocks, slabs etc in cement mortar 1:4, complete all as specified and directed.
M&L for MS TMT bars of Grade Fe 500D, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
All as per srl item No. 18 here-in-before but 5 to 10mm dia in stirrups, spacers & binders etc complete complete all as specified and directed.
M&L for Cement Concrete , 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in lintel upto 1.50 m span, cills, steps, seismic and other silmilar bands, plinth courses, sring courses,lacing courses, parapets and railings upt 60 cm in height, copings, kneelers, apex stones, bed plates, water troghs and the like including weathering, slightly rounded or camphered angles and throating, complete all as specified and directed by Engr-in-Charge.
Use & Waste Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
Use & Waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Use & Waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions
Use & Waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Use & Waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide
M&L for RCC, M-25 (Design Mix) using 20mm graded crushed stone aggregate for Foundations, Including rafts, footings, foundation beams; plinth beams, bases for columns, etc and Mass Concrete complete all as specified and directed.
M&L for RCC, M-25(Design Mix) using 20mm graded crushed stone aggregate for beams, lintels, lintel Bands complete all as specified and directed.
M&L for RCC, M-25 (Design Mix) using 20mm graded crushed stone aggregate for Columns, pillars etc complete all as specified and directed.
M&L for RCC, M-25(Design Mix) using 20mm graded crushed stone aggregate for roof Slab supported on wall, beam and column etc complete all as specified and directed.
M&L for Preparation of newly plastered surface of wall and applying 2mm thick wall care putty and making the surface smooth and applying two coat of oil bound distemper, white or tinted shade complete all as specified.
M&L for preparation of new plastered surfaces of ceiling and applying three Coats of White Wash, complete all as specified and directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified .
S&F factory made Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 105mm x 60mm Pressed steel frames for doors with one or more rebates made out of 1.25mm thick mild steel sheet including necessary fixing lugs, hinges, lock strike plate, etc. including tarring/black bituminous paint to unexposed surface, and two coat of synthetic enemal paint over a coat of red oxied primer, complete, as specified and directed.
M&L for PCC 1:3:6 nominal mix, type C-1 using 20 mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats, complete all as specified & directed.
S&F steel window/Ventilator factory made out of box type and shutter (double shutter) with sash bar made out of section using flash butt welding, hinges shall be provided to both shutters complete including all fittings including grills, glazing (glass of plain or figured type as required) , guaging (wire mesh stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts ) and two coat synthetic enamel paint over a coat of red oxide primer all as per drg No CEPZ/ TD/245/01 Sheet 1/1 and CEPZ/TD-246/01 sheet No 1/2 & 2/2 including taking down old window complete all as specified and directed by Engr-in-Charge.
S&F 100mm long Butt hinges, heavy weight, cold rolled mild steel, and fixed ISI marked
S&F aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) & fixing clips of sheet, cast and extruded section & fixing bolt & sliding bolt of extruded section of size 300mm long ISI marked complete all as specified and directed.
S&F 150 mm long 10 mm dia aluminium barrel tower bolt ISI marked complete all as specified and directed.
S&F Aluminium anodized handle cast type anodised 125mm long ISI marked
M&L for broken stone or boulders in hardcore of gauge exc 63 mm but n exc 100 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rolled/rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick Cement concrete type D-2, 1 : 4 : 8 (using 40mm graded crushed stone aggregate) as in sub floors/sub bases etc. complete all as specified and as directed.
M&L for 75mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub base even and rough finish complete all as specified and as directed.
M&L for Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed.
M&L for Glazed coloured ceramic tiles in vertical surface 450X 350X 7-8mm thick such as skirting dado, etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shed of tile including laid over 10mm thick backing layer of cement mortar (1:4) complete all as specified and as directed
M&L for 18-20mm thick Granite (of approveed colour) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including laid over 15mm thick CM 1:6 screed or backing layer complete all as specified and as directed
S&F Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position with all fittings all as specified in SSR Part I including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) complete all as specified and as directed.
S&F tube medium grade galvanized with all fittings and fixed to walls or laid in floors of 15mm bore including cutting chasing in walls etc if required complete all as specified and directed.
S&F tubes medium grade galvanized with all fittings and fixed to walls or laid in floors of 20mm bore including cutting chasing in walls etc if required complete all as specified and directed.
S&F 15 mm bore long body CP brass Bib taps cast copper alloy fancy type with crutch or butterfly handle (chromium plated), screwed down , high pressure for iron pipe complete all as spd & directed.
S&F fancy type CP stop valve/angle valve cast copper alloy screwed down high pressure ,with crutch or butterfly handle screwed both ends for iron pipe or for union of 15 mm bore complete all as specified & directed
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, Bore dia of pipe 20 mm
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, Bore dia of pipe 15 mm
S&F fancy type CP stop valve/angle valve cast copper alloy screwed down high pressure ,with long shank and cup (concealed type) for iron pipe or for union of 15 mm bore complete all as specified & directed
S&F Vitreous china wash basin,counter sunk of size 550 x 400 mm, including cutting for and pinning in ends of brackets or erecting stand including 32 mm bore CP waste pipe long screw thread and 32 mm dia flexible waste pipe incl fixing of taps including RCC slab and TMT bars to facilitate complete all as spd and directed.
S&F Vitreous China Urinal, Half stall type, white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, , flush pipe, grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) fixed incl supply and fixing of CP coupling, waste pipe and cp brass spreder all necessary fittings, complete all as specified and directed.
S&F CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F vitreous china water closet squatting pan ‘Orrissa pattern” size 580x440mm white with integral foot rests including provision of of cement concrete bedding, connection to flush pipe and making good the disturbed portion of floor to match with the existing surface jointing to PVC/CI bend and flush pipe complete all as specified and as directed by Engr-in-Charge.
S&F 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets ,fush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified.
S&F 15 mm dia PVC connection of 450mm long, PTMT nuts.
S&F brass CP Soap Dish or Soap Holder Dish round/oval shaped for Bathroom with fixing arrangement complete all as specified and as directed.
S&F swivel shower of CP brass of size 150x150mm arm of 450mm long for fixing with 15mm pipe with 45 degree with flange complete all as specified.
S&F 75mm bore cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating complete all as specified & directed.
M&L for Cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints, fixed on wall complete all as specified and as directed.
S&F 100mm dia cast iron bend with ovel access door and jointed with neat cement paste complete all as specified and as directed.
S&F 75mm dia cast iron bend with ovel access door and jointed with neat cement paste complete all as specified and as directed.
M&L for Cast iron soil, waste and vent pipes 75mm dia in any length with or without ears, with cement joints, laid on tranches or fixed on wall complete all as specified and as directed.
S&F 75mm cast iron cowl.
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof
M&L for APP modified roof treatment over existing non-accessible RCC roof slab/chajjah/canopy/ parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and as directed. (a)cleaning the top surface of RCC roofing properly with water. (b) 15 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer's instructions (c) Applying oil bound bitumen primer @ 0.3 ltr/sqm manufacture by the same agency as that of APP with a density 0.87-0.89 kg/ltr at 25 degrees centigrade on prepared surface. (d)Laying of membrane not less than 3 mm thick APP modified water proofing membrane weighing not less than 3 kg/Sqm reinforced with non-woven polyester fibre weight not less than 150 Gms/Sqm using butane by torch application with 10cm side laps and 15 cm end lap complete (e) APP membrane shall laid using butane torch by torch application with minimum 10 cm side over lap and 15 cm end lap (f)Top of membrane shall be provide with solar reflective bituminous aluminium paint @ 0.1 Kg/sqm as prescribed by manufacturer of membrane. (g) APP membrane shall be stick inside parapet where available by chase cutting and sealed with PCC 1:2:4 type B-0.
M&L for construction of soakage well of size 3.5m dia x 4m deep, including earth work in any type of soil, PCC foundation 1:3:6, old size burnt clay brick work for honey combed masonry in cement mortar 1:4 with top ring of M-25 concrete, including intercepting chamber and screen chambermade of brick masonary in CM 1:4, M-25 RCC cover slab, interlocking pipes of RCC/DWC, rest of this complete all as per Drawing No. TD- CEPZ/C-TD/ 13/13 sheet No. 1/5 and 5/5 all as specified and as directed by Engg-in-Charge.
M&L for construction of septic tank for 50 users effective depth 1.5 m and overall depth 3 meter, including earth work in any type of soil, PCC foundation 1:2:4, old size burnt clay brick work for honey combed masonry in cement mortar 1:4 with top ring of M-25 concrete, including intercepting chamber and screen chambermade of brick masonary in CM 1:4, M-25 RCC cover slab, interlocking pipes of RCC/DWC, rest of this complete all as per Drawing No. TD- CEPZ/C-TD/ 13/13 sheet No. 1/5 and 5/5 all as specified and as directed by Engg-in-Charge.
Sch 'A' Part-I E/M Portion:- M & L for point wiring with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC rigid concealed conduit heavy duty of suitable size ISI marked all fittings including anodise sheet steel/CI terminal box of adequate size with hylem/masonite sheet ISI marked for switches and sockets , including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed. Note:-1. insulation test of point wiring and colour coading is to be maintain.
All as per Srl item No 77 here-in-before but for 5 pin 5 amps socket outlet on independent board complete all as specified and directed.
All as per Srl item No 77 here-in-before but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
M & L for point wiring with 2.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC rigid concealed conduit heavy duty of suitable size ISI marked all fittings including anodise sheet steel/CI terminal box of adequate size with hylem/masonite sheet ISI marked for switches and sockets , including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed. Note:-1. insulation test of point wiring and colour coading is to be maintain.
S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S&F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
S & F energy saving decorative LED box type 20 W, 3000K, Warm white , Lumen efficiency 110 lumen/Watt, light fitting light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired without tube and making connections with twisted flexible copper cable of suitable size from ceilling rose/PVC connector to light fittings complete all as spd and directed by Engr -in -charge.
S & F bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length not less than 0.9 mtr fixing with clamp etc and making connections using suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing MS ventilating fans Single phase, 230 volts 300 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F MCB SP 240 volts any rating from 6 to 40 amps, 'B' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F MCB SPN 240 volts any rating from 6 to 40 amps, 'B' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Supply and installation of the electric water storage heater of ABS body type, 25 ltr capacity with rated power 2KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm bore with GI hexagonal adopters/nuts on both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangements and mounting on wall with suitable size of anchor bolts including connection with PVC pipe of suitable size (hot & cold type) including with complete connection of water including testing after installation complete all as specified and as directed.
M & L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Supply, laying and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 2 core complete all as specified
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified (Note:-Punned thickness shall be measured and paid)
M&L for brick covering equal to length of bricks as mechanical protection to cable with well burnet sub class ‘B’ bricks laid as directed by the Engr-in-Charge.
Returning, Filling in, including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point complete all as specified and directed.
S&F GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole including fittings /clamp complete all as specified and directed.
S&F tubes medium grade galvanized with all fittings and laid in tranches, floor, along with wall/ceiling etc. of 25mm bore including cutting chasing in walls, bend, clamps, nut bolts and washers etc. if required complete all as specified and directed.
S&F 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
M&L for cutting/drilling of GI pipe upto 50/80 mm dia for connecting of 25/50mm GI pipe including all required accessories complete all as specified and as directed.
Ambika Construction Co (BID ID -3384194)
HARI OM ENTERPRISES (BID ID -3384968)
GANDOTRA CONSTRUCTION CO (BID ID -3392347)
Substantial Const. Co. (BID ID -3392573)
kay gee construction co (BID ID -3383368)
OMKAR SHARMA AND CO (BID ID -3384509)
DABGOTRA BUILDERS (BID ID -3384972)
M/S Raghuvanshi Builders (BID ID -3385124)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .