Executive Engineer HSVP Electrical Division SCO No.24 First Floor near SRS Mall, Sector-12 Faridabad Pin Code- 121007
Providing Ceiling Fan, exhaust fan, exhaust fan louver and AC in 33 KV Switching Substation Sector-75 at Faridabad. (Including 1 (one) Year defect liability period free of cost).
2026_HBC_548187_1
20262B207010 4DC5 4112 8133 717BDC3F968B364HSV
Open Tender
Electrical Works
Works
30 days
Faridabad (MC)
Providing Ceiling Fan, exhaust fan, exhaust fan louver and AC in 33 KV Switching Substation Sector-75 at Faridabad. (Including 1 (one) Year defect liability period free of cost).
2 documents required · 2 mandatory
₹250
₹2,300
Yes
16 Sept 2026
16 Sept 2026
24 Sept 2026
16 Sept 2026
22 Sept 2026
16 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm) | 11 | Each | 2,054 | ₹22,594 |
| 2 | [21.104.1]Supplying, erection, testing and
commissioning of submersible motor pumping set non clog for sewerage having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation
Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect 1. Discharge Capacity (LPM) - 20 Power Capacity (BHP) - 1 | 1 | Each | 31,539 | ₹31,539 |
| 3 | [23.11]Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required | 4 | Each | 381 | ₹1,524 |
| 4 | [23.12]Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required | 4 | Each | 256 | ₹1,024 |
| 5 | [23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. | 11 | Metre | 106 | ₹1,166 |
| 6 | [24.5.1.1]MISCELLANEOUS ITEMS 1.1. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.
Submersible Copper Cable 3 Core 1.5 sqmm | 50 | Per Metre | 88.4 | ₹4,420 |
| 7 | Supply and erection of Exhaust Fan Louver Shutter Cover Fleper (600 mm), 24 inch, shutter type, material- aluminuim, shape- square, finish – powder coated Complete with necessary fitting on wall complete in all respect up to the Entire satisfaction of Engineer-In-Charge. | 4 | Each | 2,910 | ₹11,640 |
| 8 | Supply, Installation, Testing and Commissioning of 4 KVA stabilizer copper wound complete in all respect up to the entire satisfaction of the engineer in-charge of the work. Make:- Microtek /Logistic (Rate without GST) | 1 | Each | 4,370 | ₹4,370 |
| 9 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and
Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature).
Inverter Type- Cooling only
Split Air Conditioner 1.5 Ton | 1 | Each | 36,897 | ₹36,897 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
BOQ_627886.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .