Loading…
Loading…
Tender Value
₹50.8 L
EMD Value
₹1.0 L
Closing Date
5 Oct 2026, 10:00 am
Executive Engineer
Electrical Division PWD B and R Jalandhar
Installation of 2 Nos 15 Passenger Lifts 1no for Public and 1 no for Judges at Judicial Court Complex at Phillaur Disst Jalandhar
2026_CEPW_175951_1
17 dt. 22.09.2026
Open Tender
Electrical Works
Percentage
Phillaur Distt Jalandhar
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
₹1.0 L
23 Sept 2026
23 Sept 2026
5 Oct 2026
23 Sept 2026
5 Oct 2026
23 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1S/I/T/C of Elevator Type Passenger elevator Capacity 1020 kg or 15 persons Speed 1 m/s Stops & Openings 3 stops & 3 openings, Single entrance car Travel height 10 m Elevator Grouping Simplex Full Collective Control Well Dimension 2560 mm width and 1900 mm depth (required) or 2000mm (width) and 2560mm (Depth) as per well size available at site, Head Room height 4500 mm (minimum) Pit Height 1500 mm (required) MAP Floor Position Topmost floor (TOP) Car dimensions 1600 mm wide x 1500 mm deep or as required (2.4 m2 area) x 2300 mm high Door dimensions 1000 mm wide x 2000 mm internal height Door type Two-panel centre opening Plain Panel Finishes Car design SS silver brushed Car Panel Finish Honeycomb textured StSt Handrail Round Bend Handrail Silver brushed stainless steel (ST4) at Rear Wall Ceiling & Lighting Integrated roof RS60 Brushed stainless steel SUS304 (ST4) Round spot LED light Flooring 20 mm Silver brushed stainless steel AISI304 finishing (ST4) Car Door Finish Brushed stainless steel SUS304 (ST4) Car operating panel 1 Full Height ST4 - Silver Brushed St. St. AISI304 Silver brushed StSt Segmented LCD display Square surface mounted Buttons with braille Landing Signalization Silver brushed stainless steel (ST4) 7 segment display Flush Mounted Silver brushed StSt Square,surface mounted with braille Features Standard Car Emergency Light Fireman Drive Curtain of Light 169 Beams Accurate Relevelling, Automatic Closed Door Emergency Rescue Device with audio announcer Three-way intercom Nudging service Attendant Service Lift Announcer Round spot LED light 2 hours fire rated landing doors Automatic Brake Inspection -Every Day automatic brake testing to ensure safe and smooth travel. CAR FINISH:- HONEYCOMB/ VANDAL/Linen | |||||
| 1.1 | Manual Rescue Lever-Mechanical Operated Inbuild Car Gate lock for safety of Passenger-Automatic locks the car doors when stuck between floors. Battery Operated Emergency Light with Rechargeable Battery Battery Operated Emergency Alarm with Rechargeable Battery Micro Movement L.E.D. based Buttons Load Weighing device with overload Bypass feature Handrail on Rear Side Double Phase - Fire Man Drive Fire Man Switch at Main Lobby Motor compatible for 180 Starts Per hour. Automatic Phase Reversal Protection Motor Heat Protection Power Saving Mode in Ideal Condition complete in all respect as desired by Engineer in charge at site and features mentioned below. | - | - | - | - |
| 1.2 | Car Entrance: Center Opening Automatic Doors in Stainless Steel Panels in hairline Finish Scratch Resistance/Vandal proof There should be no difference in level between the lih door a door and building floor should not be more than 12 mm.
Hoist way Entrance: Ground to second panel Center opening Automatic Door's of Stainless steel Finish Scratch Resistance/Vandal proof with provision of emergency key opening at landings with a clear opening of 800mm (wide) X 2000mm (high)
Door operation: Automatic DC Door operation with adjustable door opening and closing timings
Control Simplex full selective collective control with and without attendant
Operation: Automatic
Power Supply: 415 Volts, 3-phase, 50Hz Alternating Current
Flooring: Floor Skid- Resistant as per standard
Fan: Blower Fan in Car for ventilation with Auto cut off
Lighting: LED for Car Lighting | - | - | - | - |
| 1.3 | Indicators: LED Dot matrix/Digital 3 segement direction and position indicators in the car and at all landings
Hand Raill: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear)
Call Button Height: Call Button (outside the lift) placed at a height between 800mm- 1meter from the floor level and have a clear floor space minimum 900mmX1200mm
Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level with no obstruction placed to prevent a wheelchair user from reaching it and have buttons with Braille/raised letters and in sharp contrast from the background to naid people with visual impairments.
Lift Signage: Signs indicating the location of an accessible lift should be provided in a location that is clearly visible form the building enterence. The sign should incorporate representation of the International Symbol for Access. A Sign indicating the number of the floor should be provided on each lift landing on the wall opposite the lift.It is also recommended to install a floor directory of the main facilities and services available on the lift landing, along with an accessible emergency egress route that clearly indicates the location of nearest refuge areas for persons with Disabilities.
Audio and Visual Indicators. The lift should have a voice announcement system along with a visual display to indicate the floor level and also the information that the door of the cage is open or closed for enterence or exit. The announcement system should be clearly audible i.e the announcement should be 50 decibel.
Free service One years after the S/I/T/C work and all std. Govt. features | - | - | - | - |
| 1.4 | Other Features:
1.Battery operated emergency light with rechargeable battery. 2.Battery operated emergency alarm with rechargeable battery. 3.Adjustable Guide shoes. 4.Micro moves LED based buttons. 5.Door open and Close Buttons. 6.Emergency intercom provided inside the elevator. 7.Emergency Intercom usable without the voice communication. 8.Load weighing device with overload bypass feature and overload function with audio visual indication. 9.Steel items, door frames, sill angle's fascia plates, spring buffers. 10.Automatic phase reversal device and phase failure protection. 11.Call registration. 12.Audio and video system installed in the lift indicating arrival at a floor. 13.Manual Brake lever. 14.Additional car gate lock. 15.Automatic brake testing infrared safety curten. 16.Braille Buttons (Inside and Outside) with Braille instructions for the communication system . 17.Kick Plate/ Skirting. 18.Lift announcement System to announce floor levels in english language only and indication of door for entrance/exit is either open or close. 19.Car Operating Panel. 20.Car plateform constructed out of cold rolled grain oriented formed sheets of steel. 21.Phase two device fire man drive. 22.Fireman switch at main lobby. 23.Car false ceiling in stainless steel. 24.Pit ladder 25.Anti nuisance car call protection. 26.Door nudging. 27.Automated rescue device to bring the elevator to the nearest landing in case of power failure. 28.The use of visually and acoustically reflective wall surfaces should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuty of people with impairments. 29.The floor of the lift car should be slip resistant and have similar frictional qualities to the floor of the lift landing to decrease the risk of stumbling. 30.The provision of a mirror on the wall of the lift car opposite the lift door is a positive aid to navigation for wheelchair users it allows the wheelchair user to see if anyone is behind them and also to see the floor indicator panel. The mirror should not extended below 900mm from the lift door to avoid confusing people with impaired sight. 31.The emrgency communication system should be coupled with an induction loop system installed all around the lift . Telephone units where provided, should have an inbuilt inductive coupler to assist persons using hearing aids 15 passenger lift to be provided which allows easy maneuverability of wheel chair. | 2 | Each | 24,20,390 | ₹48,40,780 |
| 2SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- | |||||
| 2.1 | Wiring light point | 8 | Each | 711.11 | ₹5,688.88 |
| 2.2 | Wiring 6Amp. wall socket point | 8 | Each | 617.61 | ₹4,940.88 |
| 3PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: | |||||
| 3.1 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.04 MB
Additionalconditions.pdf
Additional Documents • 4.98 MB
BOQ_358124.xls
BOQ • 0.29 MB
SBD.pdf
Tender Documents • 15.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .