Shri Niranjan Lal GE(S) BTD
GE (S) Bathinda Bathinda Mil Stn
REPAIR REPLACEMENT OF INTERNAL UNSERVICEABLE POINT REWIRING FITTINGS FIXTURES DBS SUB MAIN WIRING SWITCHES AND CONNECTED ACCESSORIES WORK IN GOVIND AND RANJIT COLONY UNDER GE(S) AT BATHINDA MIL STN
2021_MES_461247_1
GE(S) BTD/TOKEN NO/27/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda Mil Stn
AS PER NIT
10 documents required · 10 mandatory
₹500
GE(S) Bathinda
₹30,000
Yes
3 Sept 2021
19 Jul 2021
18 Aug 2021
19 Jul 2021
16 Aug 2021
2 Aug 2021
20 Jul 2021 - 26 Jul 2021
Amount
Taking down carefully existing copper point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, callbells etc removiing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete all as specified and directed
M & L for point wiring for one light / fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including concealed PVC conduit 20 mm dia medium duty ISI marked, steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) complete all as specified and directed .(Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A' /BOQ ).
All as per srl item No. 2.00 (here-in-before) but socket 3 pin 5 Amp 230 volt flush type on same board complete all as specified and directed
All as per srl item No. 2.00 (here-in-before) but for one socket point out let 3 pin 5 Amp in independent board complete all as specified and directed
All as per srl item No. 2.00 (here-in-before) but for call bell point complete all as specified and directed
All as per srl item No. 2.00 (here-in-before) but for one light point controlled by two two way switchcomplete all as specified and directed
All as per srl item No. 2.00 (here-in-before) but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed
M & L for point wiring for one light / fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi stranded copper conductor cable FR-LSH in existing conduit, and existing sunken boxes but including 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch and /or fan regulator including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly complete all as specified and directed
All as per srl item No. 8.00 (here-in-before) but socket 3 pin 5 Amp 230 volt flush type on same board complete all as specified and directed
All as per srl item No. 8.00 (here-in-before) but for one socket point out let 3 pin 5 Amp in independent board complete all as specified and directed
All as per srl item No. 8.00 (here-in-before) but for call bell point complete all as specified and directed
All as per srl item No. 8.00 (here-in-before) but for one light point controlled by two two way switch complete all as specified and directed
All as per srl item No. 8.00 (here-in-before) but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed
S&F Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed
S&F Switch piano, flush type single pole, two way 5 Amp complete all as specified and directed
S&F bell push 5/6 Amps 230 V AC complete all as specified and directed
S&F Socket outlet 3 pin, 5A, flush type complete all as specified and directed
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed
S&F Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply complete all as specified and directed
S&F call bell ding dong type AC 230 V complete all as specified and directed
S&F wall mounted extruded Aluminium/polycarbonate LED batten fixture T8(G13 holder) 1.2 m, including one LED retrofit tube 20(±10%) watt, 1.2 m T8 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete complete including making connection complete all as specified and directed.
S&F wall mounted LED batten fitting 10 (±10%) watt, 6500K, 0.6m, efficacy not less than 90 lumen/watt , extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete includign making connection complete all as specified and directed.
S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete all as specified and directed
S&F Lamp holder PVC/polycarbonate type with back plate complete all as specified
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit and including all as specified.(Note:- Three lengths of 6 Sqmm cable will be measured as one length). (Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cable will be measured as one running length)
S&F in replacement sheet metal encloser double door 8 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
-do- all as per item No 28 above but 04 way TPN 415 V complete all as specified and directed.
S&F in replacement single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one single pole MCB 20Amp complete all as specified and directed
S&F in repair MCB 6-32 Amp 240V SP 10 KA ‘C’ series complete all as specified and directed
S&F in repair MCB 20-32 Amp 240V SPN 10 KA ‘C’ series complete all as specified and directed
S&F in repair MCB 415V 40 to 100Amp TPN 10 KA ‘C’ series complete all as specified and directed
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable.
NOTE :- ARMAAN COMPLAINT/DAY TO DAY/DOOR TO DOOR COMPLAINTS (From Item No 35.00 to 60.00):- Complaints regarding repair/replacement to these items to be attended unconditionally. All in cost incurred upon deemed to be included in respective items
S&F in repair Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed
S&F in repair Switch piano, flush type single pole, two way 5 Amp complete all as specified and directed
S&F in repair Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed
S&F in repair Bell push 5/6 Amps 230 V AC complete all as specified and directed
S&F in repair Socket outlet 3 pin, 5A, flush type complete all as specified and directed
S&F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed
S&F in repair Call bell AC 230 V single polecomplete all as specified and directed
S&F in repair Lamp holder PVC/polycarbonate type with back plate complete all as specified and directed
S&F in repair wall mounted extruded Aluminium/polycarbonate LED batten fixture T8(G13 holder) 1.2 m, suitable for T8 retrofit tube complete including making connection complete all as specified and directed.
S&F in repair retrofit LED tubelight 20(±10%) watt, 1.2 m T8 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete all as specified and directed.
S&F in repair LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete all as specified and directed
S&F in repair wall mounted LED batten fitting 10 (±10%) watt, 6500K, 0.6m, efficacy not less than 90 lumen/watt , extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete includign making connection complete all as specified and directed.
S&F in repair LED light fitting 9/10W bulkhead luminaires incluing LED light, driver, holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Fixing only and connecting electric meters complete all as specified and directed Note: Meters shall be issued sch 'B' of free for fixing only.
Taking down unsv ceiling fan/exhaust fan, sealing cable end dismentaing blades and removing fan and blades to E/M store yard.
Hanging only ceiling fan and connecting up incluidng provision of cable from ceiling rose or connector to fan. Note: Ceiling Fans will be provided by the E/M store free for fixing only.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan.Note: Exhaust fan will be provided by the E/M store free for fixing only.
S&F in repair rigid non-metallic PVC conduit external dia 20mm in size exclusive of boxes(junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed
S&F in repair PVC junction boxes(1 to 4 way) complete all as specified and directed
S&F in repair Hylam sheet cover 3mm thick of size 5"x5" complete with machine screw/ washer with provision of witches, sockets, fan regulators etc complete all as specified and directed
S&F in repair Hylam sheet cover 3mm thick of size 8"x5" complete with machine screw/ washer with provision of witches, sockets, fan regulators etc complete all as specified and directed
S&F in repair Hylam sheet cover 3mm thick of size 11"x8" complete with machine screw/ washer with provision of witches, sockets, fan regulators etc complete all as specified and directed
S&F in repair MS Sunken box of size 4"x4" with approved depth & thickness complete with earth dolly including making good the disturb surfaces CM (1:3) to match the existing complete all as specified and directed
S&F in repair MS Sunken box of size 7"x4" with approved depth & thickness complete with earth dolly including making good the disturb surfaces CM (1:3) to match the existing complete all as specified and directed
S&F in repair MS Sunken box of size 10"x7" with approved depth & thickness complete with earth dolly including making good the disturb surfaces with CM (1:3) to match the existing complete all as specified and directed
Note:- Net contract sum shall be calculated after deduction of Sch of credit of Rs. 88010.00.
M/s Bhullar Constructions
NASIB ENGINEERS AND CONSTRUCTION
M/s SUPERTECH ENGINEERS
L H ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .