Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹30.5 L+₹7.3 L (31.4%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹32.1 L+₹8.9 L (38.3%)Rejected-AOC 451 NEAR RADHA KRISHAN MANDIR VPO MAMUN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹33.6 L+₹10.4 L (45.0%)Rejected-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹35.3 L+₹12.1 L (52.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
28 Sept 2022, 6:00 pmClosed
Garrison Engineer (N) Mamun
Garrison Engineer (N) Mamun Pin-145001
REPAIR/ MAINTENANCE AND REPLACEMENT OF SECURITY LIGHTS, LT PANELS, EARTHING, MCCBS AND CONNECTED ITEMS AT D-1A ZONE, MAP BHASKER, D-III ZONE AND D-IV ZONE AREA UNDER AGE E/M -1 OF GE (N) MAMUN
2022_MES_549011_1
GE(N)/M-12/2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (N) Mamun
₹80,000
16 Nov 2022
1 Sept 2022
30 Sept 2022
1 Sept 2022
28 Sept 2022
16 Sept 2022
Amount
Dismantling and taking down security light/flood light fitting of any wattage or size from pole or high mast lights for repair, checking all wiring and serviceability of all components, repairing of minor faults of any type or replacing burnt/ un-serviceable accessories, refixing at the same or different location complete all as specified and directed. Note :- Replacement of burnt and un serviceable items shall be measured and paid separetly.
S&F in replacement electronic driver suitable for LED fittings 45 watts any type and make (as per sample) complete all as specified and directed.
S&F in replacement electronic driver suitable for LED fittings 90 watts any type and make (as per sample) complete all as specified and directed .
S&F in replacement surge protection device 10 kv any type and make (as per sample) all as specified and directed .
M&L for preparation of old painted steel surface of poles by sanding, scratching etc, priming surface with red oxide primer , applying two coats of aluminium paint including painting the poles with alternate layer of 30 cm, white and green paint with synthetic enamel paint upto 1.5 mtr above from the coping and writing pole No complete all as specified and directed.
S&F in replacement LED street light 45W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing, power coated pressure die cast aluminimum housing, IP 65 protection, high power LED street light with heat resistent toughened glass lens and making electrical connections with twin core twisted copper conductor flexible copper wire of suitable size from street light to junction specified and as directed. Notes:- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 for 50000 burning hours 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. PCB used shall be MC PCB type 8 The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
All as per item 6 but LED street ligh 90W
S&F in replacement junction box, water proof, outdoor type made out of SMC of exterenal dimensions 250 x 250 x 105 mm, single door type hinged with locking arrangement front operated with one number MCB 06 Amps capacity for housing 3 phase and neutral busbar including connecting the incoming/outgoing cables including cable glands and fixed to the existing poles with mild steel clamp flat of size 25 mm x 4 mm with nut, bolts complete all as specified and directed.
M&L in replacement for PVC insulated PVC sheathed multicore flexible copper cable conductor of 1100 Volts grade confirming to IS-694/2010 of size 1.5 sqmm 3 core including necessary drilling on pole complete all as specified and as directed.
Dismantling and taking down LED traffic light fitting of any wattage from traffic pole for repair, checking all wiring and serviceability of all components, repairing of minor faults of any type or replacing burnt/un-serviceable accessories, PCBs board, LED 1.5 v, opening glass etc and refixing same complete all as specified and directed. .
S&F in replacement MCCB 3 pole 415 volts , fixed type 100 Amps with breaking capacity 25 KA, fixed thermal from 80 to 100% & fixed magnetic release with Ics = 100% Icu, including spreadres after taking out old U/S one all as specified and directed.
S&F in replacement MCCB 3 pole 415 volts fixed type 200 Amps with breaking capacity 25 KA, fixed thermal from 80 to 100% & fixed magnetic from 5 to 10 In with Ics = 100% Icu including spreadres after taking out old U/S one all as specified and directed.
S&F in replacement MCCB 4 pole 415 volts fixed type 100 Amps with breaking capacity 25 KA, fixed thermal from 80 to 100% & fixed magnetic release with Ics = 100% Icu , including spreaders after taking out old U/S one all as specified and directed.
S&F in replacement MCCB 4 pole 415 volts fixed type 200 Amps with breaking capacity 25KA fixed thermal from 80 to 100% & fixed magnetic release adjustable from 5 to 10 In with Ics = 100% Icu, including spreaders after taking out old U/S one all as specified and directed .
S&F in replacement MCCB 4 pole 415 volts fixed type 400 Amps with breaking capacity 36KA thermal release adjustable from 80 to 100% & magnetic release adjustable from 5 to 10 In with Ics = 100% Icu, including spreaders after taking out old U/S one all as specified and directed .
S&F in replacement MCCB 4 pole 415 volts fixed type 630 Amps with breaking capacity 36KA thermal release adjustable from 80 to 100% & magnetic release adjustable from 5 to 10 In with Ics = 100% Icu, including spreaders after taking out old U/S one all as specified and directed .
Disconnecting incomimg/outgoing cable of LT panel and cleaning, servicing and remove any type dust, corbon on MCCBs reconnecting same cable after all processing of replacing of MS/CRCA sheet where ever required , door higes/door locing arrangements and complete scrubing the LT panel and painting with two coats of enamelled paint , refinshing paint of approved colour over one coat of red oxide including cutting bushes,levelling the area around LT panel etc including surface excavation not exceeding 30 cm deep and average 15cm deep and geting out roots etc and removing from site not less than 50mtrs and surface dressing with PCC work (1:4:8) all as specified and directed . Note :- MS /CRCA sheet,MS but hinges,MS door sliding door bolts(locking system) , MS angle will measured separetly.
Repair and maintenance of LT panel denting and welding works for re-sahaping the dameged portion of panel by manual process all as specified and directed.
Supply and welded in repairs, cold rolled mild steel butt hinges medium weight, 100mm long complete all as specified and directed
Supply and welded in repairs, mild steel sliding door bolt (loking system) 250mm long complete all as specified and directed
M&L in replacement for LT panel door fabricated from suitable size of thick MS /CRCA sheet cutting , bending welding and smooth surface finishing size suitable for existing panel.Mild steel plain, black sheet in wall cladding , steel gates and similar work, cut to size, holes , punched , including round headed screws clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams , including bending or turning up , mitred angles etc. as required size of existing door complete all as specified and directed..
Lifting existing LT panel by help of hydro machine operated with manual from below ground level including shifting on other place and again lifting the panel for landing the same old places after completion of all work, all as specified and directed. Note :- MS angle iron, excavation for trenches , laying of cable, returning filling of cable, removal of soli will measured separetly.
Dismantling and Material and labour in replacement for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat with synthetic enamel paint complete all as specified and as directed.
Taking out LT cable,1100 volts grade heavy duty,aluminium conductor of any size up to 25 sq mm from trench/cable duct/through wall/pole carefully, removing defective length and stacking aside for re use or for taking credit to contractor all as specified and directed. Note: Excavation and other earth work shall be measured and paid seperately under relevant item.
All as per Srl Item 31 here in above but of size 35 Sqmm to 50 Sqmm
All as per Srl Item 31 here in above but of size 70 Sqmm to 185 Sqmm
All as per Srl Item 31 here in above but of size 240 Sqmm to 300 Sqmm
Laying only cable of any size up to 25 Sqmm all as specified and directed.
Laying only cable of size up to 50 sqmm all as specified and directed.
Laying only cable of size 70 to 185 sqmm all as specified and directed.
Laying only cable of size 240 to 300 sqmm all as specified and directed.
Supply, laying, connecting and testing in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 16 Sqmm 4 core with aluminium termination lugs, laid in trench/cable duct/through wall/pole and making good disturbed surface complete all as specified.
All as above mentioned in item No 39 here in above but Size 25 sqmm 3.5 core
All as above mentioned in item No 39 here in above but Size 35 sqmm 3.5 core
All as above mentioned in item No 39 here in above but Size 50 sqmm 3.5 core
All as above mentioned in item No 39 here in above but Size 95 sqmm 3.5 core
All as above mentioned in item No 39 here in above but Size 185 sqmm 3.5 core
All as above mentioned in item No 39 here in above but Size 240 sqmm 3.5 core
All as above mentioned in item No 39 here in above but Size 300 sqmm 3.5 core
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
Supply of brick sub class 'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable (total 23cm punned thickness) to trenches complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregrate for coping of poles and foundation of stay complete all as specified.
Dismantling /taking out existing GI tubing , S&F GI tubing, light grade 40 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed. (clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as mentioned in item No 53 here in above but 50 mm bore
All as mentioned in item No 53 here in above but 80 mm bore
All as mentioned in item No 53 here in above but 100 mm bore
M&L for Cable end jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16sqmm 4 core complete all as specified and as directed. Note: Cost of excavation, returning filling if required is deemed to be included in quoted rate.
All as above mentioned in item No 57here in above but Size 25 sqmm 3.5 core
All as mentioned in item No 57 here in above but size of 35 - 50 sq mm, 3.5 core
All as mentioned in item No 57 here in above but size of 70-150 sq mm, 3.5 core
All as mentioned in item No 57 here in above but size of 185-240 sq mm, 3.5 core
M&L for Cable straight through jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for 2/3.5 core XLPE armoured aluminium conductor cable of size up to 50 sqmm size complete all as specified and as directed. Note: Cost of excavation,returning filling if required is deemed to be included in quoted rate.
All as mentioned in item No 62 here in above but size of 70-150 sq mm, 3.5 core
All as mentioned in item No 62 here in above but size of 185-240 sq mm, 3.5 core
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by 25X4 mm GI strip as earth lead by means of nuts and bolt,thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,80 mm thick RCC pit cover 320mm x 320 mm of RCC 1:2:4 Type B1 using 20 mm graded stone aggregate reinforced with XPM jelly and charcoal ,dust and common salt all as shown in electrical plate No 5 of MES SSR Part -1 (1991) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia medium grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete all as specified and directed. Note: RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 96,073.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
M/S MULTI ENGINEERS
RD Engineers
M/S SHRI RAM BUILDERS
dinesh enterprises
KULBHUSHAN AGGARWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .