16 Jul 2022, 11:00 amClosed
Executive Engineer Electrical HPPWD Division Una
Executive Engineer Electrical HPPWD Division Una
.
2022_PWD_62486_1
TA/No. 2722-44 dated 28.06.2022
Open Tender
Electrical Works
Item Rate
365 days
Una
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,500
₹50,500
2 Sept 2024
7 Jul 2022
16 Jul 2022
7 Jul 2022
16 Jul 2022
7 Jul 2022
Amount
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form-
300 mm deep (nominal)(Main Panel)
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:--
300 mm deep (nominal)(Sub Panels in workshops 9 Nos. one each)
Supplying and fixing 4 pole MCCB 630 Amp Ics = 100% icu, 36 KA & @ 415 volts, 50 Hz with Microprocessor release Mtx2.0 & iTRP3 conforms to IS/IEC 60947-2 complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM93007OOOAG ),Legrand, Hager as approved by Engineer-in -charge.
Supplying and fixing 4 pole MCCB 100 Amp Ics = 100% icu, 36KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM97919OOK2OG,),Legrand, Hager , as approved by Engineer-in -charge.
Supplying and fixing 4 pole MCCB 125 Amp Ics = 100% icu, 36KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM9068100LOOG,),Legrand,Hager , as approved by Engineer-in -charge.
Supplying and fixing copper strip bus-bars suitable for 800 Amp. 415 volts capacity 4 No. each of cross-sectional area (50.80mmx9.50mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
S/F indicator set RY &B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.
supplying and fixing CT coil 600/5 amp with burden of VA 15 accuracy class -1 Make:-Automatic Electric Ltd ,L&T,Legrand .
S/F rubber mat 1x2 meter long 12mm thick infront of main panel as required including carriage of material with in all leads and lift.
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
S/F Shock treatment chart on the existing wall etc as required including carriage of material within all leads and lift.
Supplying and fixing Surge protection device protection against indirect/direct lighting surges maxiumum dicharge current- I max upto 100 KA/ 3 pole+neutral Type 1+2 .Make :L&T(AUSP 123PN100),Legrand ,Hagger as approved by Engineer-in charge.
Supplying and fixing 4 pole MCCB 40 Amp Ics = 100% icu, 36KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM97893OOF2OG,),Legrand,Hager ,Schenider as approved by Engineer-in -charge.
Supplying and fixing 4 pole MCCB 63 Amp Ics = 100% icu, 36KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM97919OOH2OG,),Legrand,Hager , as approved by Engineer-in -charge.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, DP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. L&T, legrand,Hager , as approved by Engineer-in -charge.
Supplying and fixing of 4 pole DU 125H/DU100D/DU125D/DNO MCCB Enclosure complete with connection testing and commissiong etc as required .Make:-L&T ( cat no-CM9O9960000), Legrand,Hager , or as approved by Engineer-in -charge.
Supplying and fixing of MPCB Enclosure(8537) 6Way(6module) complete with connection testing and commissiong etcasrequired .Make:-L&T ( cat no-DBENCC006SD), Legrand,Hagger , as approved by Engineer-in -charge.
6 MODULE
Supplying and Fixing Motor protection circuit breaker 1HP rotary type with short circuit and over load protection phase loss protection Icu 100KA, Curent range from 1.6 to 2.5 amps, , complete as required .Drilling holes in the cubical, making connections, etc. as required.Make:-L&T (CODE:-ST41910OOOO),Legrand,Hager , as approved by Engineer-in -charge.
Supplying and Fixing Motor protection circuit breaker 2HP rotary type with short circuit and over load protection , phase loss protection Icu 100KA, Curent range from 2.5 to 4 amps, , complete as required .Drilling holes in the cubical, making connections, etc. as required.Make:-L&T (CODE:-ST41911OOOO),Legrand,Hager , as approved by Engineer-in -charge.
Supplying and Fixing Motor protection circuit breaker 3HP rotary type with short circuit and over load protection phase loss protection Icu 100KA, Curent range from 4 to 6.30 amps, , complete as required .Drilling holes in the cubical, making connections, etc. as required.Make:-L&T (CODE:-ST41912OOOO),Legrand,Hager , as approved by Engineer-in -charge.
Supplying and Fixing Motor protection circuit breaker 5HP rotary type with short circuit and over load protection phase loss protection Icu 100KA, Curent range from 6.30 to 10 amps, , complete as required .Drilling holes in the cubical, making connections, etc. as required.Make:-L&T (CODE:-ST419132OOOO),Legrand,Hager as approved by Engineer-in -charge.
Supplying and Fixing Motor protection circuit breaker 10HP rotary type with short circuit and over load protection phase loss protection Icu 50KA, Curent range from 11 to 16 amps, , complete as required .Drilling holes in the cubical, making connections, etc. as required.Make:-L&T (CODE:-ST41915OOOO),Legrand,Hager , as approved by Engineer-in -charge.
Providing & Laying of one number aluminium conductor, PVC insulated and PVCsheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Make:-KEI(HSN CODE 8544),Havell,Polycab as approved by Engineer-in charge.
Armoured cable 300 sq. mm (3.5 core)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.KEI(HSN CODE 8544), Havell, Polycab. as approved by Engineer in -charge
Armoured cable 300 sq. mm (3.5 core)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed Unarmoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.Make:-KEI(HSN CODE 8544),POLYCAB,Havell as approved by Engineer in -charge
Unarmoured cable 35 sq. mm (3.5 core)
Unarmoured cable 50 sq. mm (3.5 core)
Supplying and making end termination with brass compression gland and alumunium lugs for following size of PVC insulated PVC sheathed/XLPE alumunium conductor cable of 1.1 KV grade as required .
3.5CX35 Sq.mm (32mm)
3.5CX50 Sq.mm (35mm)
3.5CX300 Sq.mm (70mm)
Providing, laying and fixing of PVC round sheathed 2 core 4 sqmm (un armoured)copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Providing, laying and fixing of PVC round sheathed 4 core 6 sqmm(un armoured) copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Providing, laying and fixing of PVC round sheathed 4 core 10 sqmm(un armoured) copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Providing, laying and fixing of PVC round sheathed 4 core 16 sqmm(un armoured) copper conductor flexible cable for voltage grade up to 1100 volt , as required complete in all respect. Make :-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Supplying and drawing 2x6 Sq.mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PV Cconduit/ DLP U-PVC Trunking as required. KEI,Anchor ,L&T as approved by Engineer -in -charge .
Providing and fixing DLP U-PVC adaptable trunking system and accessories 80X50 mm.on existing wall at required height from floor level including fixing flexible cover,internal angle,external angle,flat angle,centre tap complete with end cap etc,as required.( Legrand 010412 or as approved by Engineer-in -charge.
Providing and fixing DLP U-PVC adaptable trunking system and accessories 105x50 mm.on existing wall at required height from floor level including fixing lexible cover,internal angle,external angle,flat angle,centre tap complete with end cap etc,as required.( Legrand Cat.No.010422 or as approved by Engineer-in -charge.
Providing and fixing Internal angle adjustable from 80* to 100* on the DLP U-PVC trunking for making compact joint as required.( Legrand Cat.No.010602 )or as approved by Engineer-in -charge.
Providing and fixing External angle adjustable from 60* to 120* on the DLP U-PVC trunking for making compact joint as required.( Legrand Cat.No.010622 ) as approved by Engineer-in -charge.
Providing and fixing 90* Flat angle on the corner of DLP U-PVC 80x50 mm.trunking for making compact and good looking joint as required.( Legrand Cat.No.010767 )or as approved by Engineer-in -charge.
Providing and fixing 90* Flat angle on the corner of DLP U-PVC 105x50 mm.trunking for making compact and good looking joint as required.( Legrand Cat.No.010785 ) as approved by Engineer-in -charge.
Providing and fixing Flat junction for to tap - off to a branch smaller than 105X50 mm. as required.(Legrand Cat.No.010732 ) as approved by Engineer-in -charge.
Supplying and laying HDPE .pipe of 50 mm. dia underground 1.00 mtr.below ground level for laying the wire/cable etc, as required
Supplying and laying HDPE .pipe of 110 mm. dia underground 1.00 mtr.below ground level for laying the wire/cable etc, as required
Providing and fixing true power make advanced earthing system having copper pipe 3meter long 50mm dia with terminal size,internal strip size 25x3 with 50kg compound including excavation of pit and refilling the same and and making earthing pit cover 13 inch dia as required complete in all respect.make :-True power, Earth Plus, Ashloka or as per best satisfaction of Engineer-in -charge .
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required.
Supplyingandinstalling following size of perforated painted with powder coating M.S.cable trays with perforation not more than 17.5%, in convenient sections, joined withconnectors,suspended from the ceiling with M.S.suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
200 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Ratwan Light House
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .