Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹4.3 L+₹97,528 (29.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
14 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR MAINTENANCE OF SUMMER APPLIANCES AT VARIOUS UNITS BHALRA MIL STN UNDER GE I 873 EWS
2023_MES_594932_1
NIT-13 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹300
GE(I) 873 EWS
₹10,000
Yes
24 Jul 2023
12 May 2023
17 Jun 2023
12 May 2023
14 Jun 2023
26 May 2023
Amount
SPLIT TYPE AIR CONDITIONER
Taking out existing unserviceable AC of capacity 1.5/2 tonne Split type unit by carefully disconnecting existing electrical connection, removing aside, packing and servicing after proper cleaning checking of all electrical connection, checking for leakage etc if any complete all as specified and directed.
Installation of AC 1.5/2 tonne capacity after servicing and testing complete all as specified and directed.
Vacuuming leak testing, flushing and gas charging including supply of Gas for AC 1.5/2 tonne with Mafron – 22/Freon-22 refrigerant and testing complete all as specified and directed.
Supply and fixing air filter for AC of 1.5/2 tonne capacity including taking down old unserviceable air filter complete all as specified and directed.
Supply and fixing remote control with sensor circuit for AC of 1.5/2 tonne capacity including taking down old unserviceable remote control complete all as specified and directed.
Supply and fixing blower motor fan of suitable type/model of reputed Firm/Company for AC 1.5/2 tonne capacity including taking down old unserviceable blower motor fan complete all as specified and directed.
Supply and fixing thermostat for AC of 1.5/2 tonne capacity including taking down old unserviceable thermostat complete all as specified and directed.
Supply and fixing relay assembly for AC of 1.5/2 tonne capacity including taking down old unserviceable relay assembly complete all as specified and directed.
Supply and fixing cooling coil assembly for AC of 1.5/2 tonne capacity including taking down old unserviceable cooling coil assembly complete all as specified and directed.
Taking out unserviceable wiring complete for split type AC 1.5/2 tonne capacity and rewiring with suitable copper wire and testing complete all as specified and directed.
Supply and fixing condensing coil suitable for AC of 1.5/2 tonne capacity including taking down old unserviceable condensing coil complete all as specified and directed.
Supply and fixing strainer suitable for AC of 1.5/2 tonne capacity including taking down old unserviceable strainer complete all as specified and directed.
Supply and fixing running capacitor suitable for AC of 1.5/2 tonne capacity including taking down old unserviceable capacitor complete all as specified and directed.
Supply and fixing starting capacitor suitable for AC of 1.5/2 tonne capacity including taking down old unserviceable stating capacitor complete all as specified and directed.
Supply and fixing overload protection suitable for AC of 1.5/2 tonne capacity including taking down old unserviceable overload protection complete all as specified and directed.
Taking down carefully unserviceable compressor unit for AC 1.5/2 tonne capacity from base by dismantling all electrical /gas connection and S&F sealed compressor unit complete excluding vacuuming and gas charging and connecting all electrical and gas pipe connection and testing complete all as specified and directed.
Supply and fixing 1/2" dia copper tube with connection in AC including taking down old unserviceable copper tube complete all as specified and directed.
All as per item No. 1.18 above but 3/8" dia copper tube.
All as per item No. 1.18 above but 1/4" dia copper tube.
Material and labour for 1/2" to 1/4" dia PVC water pipe with all fittings and laid in floors or fixed on walls including taking down old PVC water pipe complete all as specified and directed.
Material and labour for PVC insulated, single core copper conductor (Flexible) heavy duty electric cable 1100V grade, cross-sectional area 6.0 sqmm, fixed in concealed on wall including taking down old PVC cable complete all as specified and directed.
Disconnecting the Voltage stabilizer of capacity 5 KVA from the system, repairing & refixing the same place properly making electrical connection for proper function of instrument complete all as specified and as directed.
All as per item No. 1.23 above but capacity 4 KVA
All as per item No. 1.23 above but capacity 3 KVA
All as per item No. 1.23 above but capacity 2 KVA
REFRIGERATOR
Taking out existing unserviceable Refrigerator of capacity 190 ltrs unit by carefully disconnecting existing electrical connection, removing aside, packing and servicing after proper cleaning checking of all electrical connection, checking for leakage etc if any complete all as specified and directed.
All as per item No. 2.01 above but 270 ltrs capacity.
All as per item No. 2.01 above but 310 ltrs capacity.
Installation of Refrigerator 190 ltrs capacity after servicing and testing complete all as specified and directed.
All as per item No. 2.04 above but 270 ltrs capacity.
All as per item No. 2.04 above but 310 ltrs capacity.
Material and labour gas charging (Mafron 12/freon 12) in the system including replacement of capillary tube and strainer for 190 ltrs capacity refrigerator complete all as specified and as directed.
All as per item No. 2.07 above but 270 ltrs capacity.
All as per item No. 2.07 above but 310 ltrs capacity.
Material and labour for spray painting to the outer surface of body and frame complete with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after complete removal of old paint for 190 ltrs capacity refrigerator complete all as specified and directed.
All as per item No. 2.10 above but 270 ltrs capacity.
All as per item No. 2.10 above but 310 ltrs capacity.
Supply and fixing of box type relay assembly for refrigerator 190 lit capacity including taking out old unserviceable relay assembly complete all as specified and directed.
All as per item No. 2.13 above but 270 ltrs capacity.
All as per item No. 2.13 above but 310 ltrs capacity.
Supply and fixing of thermostat with switch and knob for refrigerator 190 lit capacity including taking out old unserviceable thermostat with switch complete all as specified and directed.
All as per item No. 2.16 above but 270 ltrs capacity.
All as per item No. 2.16 above but 310 ltrs capacity.
Supply and fixing of suitable size chill tray for refrigerator of 190 lit capacity including taking out old unserviceable chill tray complete all as specified and directed.
All as per item No. 2.19 above but 270 ltrs capacity.
All as per item No. 2.19 above but 310 ltrs capacity.
Supply and fixing of cooling coil complete for refrigerators of different make for the capacities 190 lit including taking out old unserviceable cooling coil complete all as specified and directed.
All as per item No. 2.22 above but 270 ltrs capacity.
All as per item No. 2.22 above but 310 ltrs capacity.
Supply and fixing of door gasket for refrigerator 190 lit capacity including taking out old unserviceable door gasket set complete all as specified and as directed.
All as per item No. 2.25 above but 270 ltrs capacity.
All as per item No. 2.25 above but 310 ltrs capacity.
Supply and fixing ice tray for refrigerators including taking out old unserviceable ice tray complete all as specified and directed.
Supply and fixing bulb for refrigerator of any type (screw/pin type) including taking out old unserviceable bulb complete all as specified and directed.
Supply and fixing PVC insulated stranded copper conductor flexible cable, 1100 volts grade of size 2.5 Sqmm, 3 core including taking out old unserviceable cable complete all as specified and directed.
Supply and fixing plug top 5/6 amps capacity including taking out old unserviceable plug top complete all as specified and directed.
Supply and fixing PVC stand for refrigerator 190 lit capacity including taking out old unserviceable PVC stand complete all as specified and directed.
All as per item No. 2.32 above but 270 ltrs capacity.
All as per item No. 2.32 above but 310 ltrs capacity.
Supply and fixing of freezer door for 190 lit capacity refrigerator including taking out old unserviceable freeze door complete all as specified and2 directed.
All as per item No. 2.35 above but 270 ltrs capacity.
All as per item No. 2.35 above but 310 ltrs capacity.
Supply and fixing vegetable tray for 190 lit capacity refrigerator including taking out old unserviceable vegetable tray complete all as specified and directed.
All as per item No. 2.38 above but 270 ltrs capacity.
All as per item No. 2.38 above but 310 ltrs capacity.
Supply and fixing hermetically sealed compressor of refrigerator 190 lit capacity including taking out old unserviceable hermetically sealed compressor complete all as specified and directed.
All as per item No. 2.41 above but 270 ltrs capacity.
All as per item No. 2.41 above but 310 ltrs capacity.
Material and labour for rubber door gasket suitable for refrigerator of any capacity/make and provn for making air tight of the system complete all as specified and directed.
Taking out of old unserviceable door lock of refrigerator of any capacity of new door lock to match with the existing complete all as specified and directed.
Disconnecting the Voltage stabilizer of capacity 1 KVA from the system, repairing & refixing the same place properly making electrical connection for proper function of instrument complete all as specified and directed.
All as per item No. 47.46 above but capacity 0.5 KVA.
CEILING FAN
Taking down of Ceiling Fan any size from site for repair and hanging the same after repair, connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed
Dismantling of 1200/1400 mm Ceiling Fan for re-winding with suitable size of copper super enamelled wire including necessary heat varnish ,over hauling, complete and re-assembling & testing all as directed by Engineer-in-Charge
Replacement of unserviceable spares parts of suitable size for ceiling fans of different sizes/sweep:-
(a) Bushes
(b) Ball bearing. No 6201 Make : TATA/SKF
(c) Ball bearing. No 6202 Make : TATA/SKF
(d) Ball bearing. No 6203 Make : TATA/SKF
(e) Condenser 3 MFD.
(f) Condenser 2.5 MFD.
(g) Rubber Bush / Reel Insulator
(h) Canopy (set).
(j) Condenser stand / bracket made of PVC.
(k) GI nuts & bolts & washers.
(l) Split Pin.
(m) Jam nuts.
(n) Mild Steel `J’ hook for hanging fan .
EXHAUST FAN
Dismantling of 300/450 mm Exhaust Fan for re-winding with suitable size of copper super enamelled wire including necessary heat varnish ,over hauling, complete and re-assembling & testing all directed.
Replacement of unserviceable spares parts of suitable size for Exhaust fans of different sizes/sweep:-
(a) Bushes
(b) Ball bearing. No 6301 Make : TATA/SKF
(c) Fan Blade suitable for 300 mm sweep
(d) Fan Blade suitable for 450 mm sweep
(e) Condenser 3.5 MFD.
(f) Rubber Bush / Reel Insulator
PEDESTAL FAN
Dismantling of 400/450/600 mm Pedestal Fan for re-winding with suitable size of copper super enamelled wire including necessary heat varnish ,over hauling, complete and re-assembling & testing all as directed.
Replacement of unserviceable spares parts of suitable size for Pedestal fans of different sizes/sweep:-
(a) Bushes
(b) Ball bearing. No 6302 Make : TATA/SKF
(c) Fan Blade suitable for 400 mm sweep
(d) Fan Blade suitable for 450 mm sweep
(e) Fan Blade suitable for 600 mm sweep
(f) Condenser 2.5 MFD.
(g) Rubber Bush / Reel Insulator
GEYSER
Taking down UNSV geyser and replaced the defective parts by new one including reassemble the same as original and re-fixing at same place complete reconnecting and testing, all as specified and directed.
Replacement of unserviceable spares parts of suitable size for Geyser of different sizes:-
(a) Heating Element (Electric rod) of capacity up to and including 2 KW having rubber washer.
(b) Heating Element (Electric rod) of capacity up to and including 3 KW having rubber washer.
(c) Connecting pipe for geyser of inlet side
(d) Connecting pipe for geyser of outlet side
(e) Switch socket combination 5 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified & directed. Make - Legrand/Havells/Anchor.
(f) MCB SPN 40-63 Amp 10 KA 240 Volts, 'C' curvecomplete all as specified and as directed. (Make :- ABB / Siemens / Legrand / Havells / Scheinder)
(g) Plug Top, 3 pin 16 Amp, 220 volt complete all as specified and directed by Engr-in-charge.
(h) Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, in PVC casing caping of size 20/30mm with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 2.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed.
(j) Gun metal globe/gate valve 20mm bore ISI marked including jointing material.
(k) Gun metal globe/gate valve 15mm bore ISI marked including jointing material.
narayan construction
Bidder Name
CONTRACTORS INDIA
narayan construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .