Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.8 LAccepted-AOC 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | 1 | Accepted-AOC L1 | |
| 2 | 1₹5.4 LAccepted-AOC 53 54 56 AND 57 HADPSAR IND ESTATE PUNE MAHARASHTRA 411013 | PUNE | PUNE | MAHARASHTRA | 411013 | 1 | Accepted-AOC L1 | |
| 3 | 1₹5.7 LAccepted-AOC 204 205 KAILASH TOWER TONK ROAD JAIPUR RAJASTHAN | JAIPUR | JAIPUR | RAJASTHAN | 302015 | 1 | Accepted-AOC L1 | |
| 4 | 1₹45.1 LAccepted-AOC B WING 601 602 DELPHI BUILDING CENTRAL AVENUE HIRANANDANI BUSINESS PARK POWAI MUMBAI MAHARASHTRA 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | 1 | Accepted-AOC L1 |
Tender Value
Refer Docs
Closing Date
22 Sept 2020, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr.Puneet Khanna (Head-Supply Chain Management)
Worley India Private Limited, New Energy House,RamakrishnaMandir Road, Kondivita, Andheri (East), Mumbai- 400 059, India
FIELD TRANSMITTERS (F, L, P, PD AND T)
2020_REFHQ_122497_1
44AC7500-00-ER-64-0047
Limited
Instrumentation-Goods
Supply
120 days
IOCL PANIPAT, HARYANA INDIA
3 documents required · 3 mandatory
Exempted
4 May 2021
25 Aug 2020
23 Sept 2020
25 Aug 2020
22 Sept 2020
1 Sept 2020
120 days
Field Transmitter: Differential Pressure Flow
DP FLOW TRANSMITTER Element Type: Averaging Pitot Tube (By Others) Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 1250 mm H2O. With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0048)
DP FLOW TRANSMITTER Element Type: Conc. Square Edge Orifice Plate (By Others) Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 2500 mm H2O. With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-
DP FLOW TRANSMITTER Element Type: Conc. Square Edge Orifice Plate (By Others) Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 2500 mm H2O. With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DP FLOW TRANSMITTER Element Type: Conc. Square Edge Orifice Plate (By Others) Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 1250 mm H2O. With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DP FLOW TRANSMITTER Element Type: Conc. Square Edge Orifice Plate (By Others) Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 1250 mm H2O. With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048) Special Requirement: IBR
DP FLOW TRANSMITTER Element Type: Conc. Square Edge Orifice Plate (By Others) Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 3750 mm H2O. With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DP FLOW TRANSMITTER Element Type: Averaging Pitot Tube (By Others) Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 1250 mm H2O. With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
Field Transmitter: Differential Pressure Level
DP LEVEL TRANSMITTER Sensor Material : SS 316 Chemical Seal Material: Extended type (50 mm) SS 316L Process Connection: 4”, 300#, RF, SS 316L Pad Flanged on HP side & LP side open to atm. Flushing Ring: N/A Calibration Range: 5086 mm H2O. (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0048)
DP LEVEL TRANSMITTER Sensor Material: SS 316 Chemical Seal Material: Flush Mount Titanium Process Connection: 3”, 300#, RF, Titanium Flanged on HP & LP Sides. Flushing Ring: Titanium with 2 nos. ½” NPT(F) flushing connections Level Range: 2000 mm. (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0048)
DP LEVEL TRANSMITTER Sensor Material : SS 316 Chemical Seal Material: Flush Mount SS 316L Process Connection: 4”, 300#, RF, SS 316L Pad Flanged on HP & LP Sides. Flushing Ring: N/A Level Range: 2760 mm. (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0048)
DP LEVEL TRANSMITTER Sensor Material : SS 316 Chemical Seal Material: Flush Mount SS 316 Process Connection: 3”, 300#, RF, SS 316 Flanged on HP & LP Sides Calibration Range: 0 to 2780 mm H2O. (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DP LEVEL TRANSMITTER Sensor Material : SS 316 Chemical Seal Material: Flush Mount SS 316 Process Connection: 3”, 300#, RF, SS 316 Flanged on HP & LP Sides Calibration Range: 0 to 4600 mm H2O. (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DP LEVEL TRANSMITTER Sensor Material : SS 316 Chemical Seal Material: Flush Mount SS 316 Process Connection: 3”, 300#, RF, SS 316 Flanged on HP & LP Sides Calibration Range: 0 to 1470 mm H2O. (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DP LEVEL TRANSMITTER Sensor Material : SS 316 Chemical Seal Material: Flush Mount SS 316 Process Connection: 3”, 300#, RF, SS 316 Flanged on HP & LP Sides Calibration Range: 0 to 1460 mm H2O. (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DP LEVEL TRANSMITTER Sensor Material : SS 316 Chemical Seal Material: Flush Mount SS 316 Process Connection: 3”, 300#, RF, SS 316 Flanged on HP & LP Sides Level Range: 605 mm. (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
Field Transmitter: Pressure Transmitters
PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 8 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020)
Field Transmitter: Differential Pressure
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 3 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 0.7 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 0.3 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: -1000 to 1000 mm H2O. With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: -0.7 to 6 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 0.5 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 0.8 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 0.2 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 1.4 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
DIFFERENTIAL PRESSURE TRANSMITTER Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 0.1 kg/cm² With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0048)
Temperature Transmitters
Field Transmitter: Temperature (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0049)
Field Transmitter: Loop Powered Indicators (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0050)
Hand Held HART Communicator as per Specifications listed in RFQ Clause 6.35
Description of Work / Item(s)
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.04 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.05 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.06 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.07 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.04 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.05 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.06 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.07 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.08 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 3.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.04 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.05 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.06 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.07 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.08 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.09 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 4.10 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 5.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 6 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 7 OF BOQ1
YOKOGAWA INDIA LTD
Honeywell Automation India Limited.
Emerson Process Management
Emerson Process Management
YOKOGAWA INDIA LTD
ABB India Ltd
Emerson Process Management
ABB India Ltd
Honeywell Automation India Limited.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .