Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹45,954Qualified Make: safex
Model: SAFEX IS BASED GAS CARTRIDGE 9 WATER 52 2ND FLOOR AMARWADI NATH MADHAV PATH C P TANK MUMBAI MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | Make: safex
Model: SAFEX IS BASED GAS CARTRIDGE 9 WATER | ₹45,954 | L2 | Qualified |
| 2 | L3₹42,550Qualified Make: fireteks
Model: 9 liter water cartridge KRUNAL COMPUND GALA NO 1 GANPATI PADA SARUVE NO 285 NEAR HINDALCO VITAWA KALWA E THANE 400605 THANE CITY MAHARASHTRA 400605 | THANE | MAHARASHTRA | 400605 | Make: fireteks
Model: 9 liter water cartridge | ₹42,550 Quoted ₹49,634 | L3 | Qualified |
| 3 | Qualified Make: SAFETY FIRST
Model: SF WC02-9 C 210 BHAICHAND TEXTILE MILL LBS MARG BHANDUP WEST MUMBAI MAHARASHTRA 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | Make: SAFETY FIRST
Model: SF WC02-9 | - | - | Qualified |
| 4 | Disqualified Make: intime
Model: CW9 21 A GHANSHYAM INDL ESTATE VEERA DESAI ROAD ANDHERI MUMBAI MAHARASHTRA 400053 | MUMBAI SUBURBAN | MAHARASHTRA | 400053 | Make: intime
Model: CW9 | - | - | Disqualified |
| 5 | Disqualified Make: SOMAIYAS101
Model: WGC-9 22 RICHHAI INDUSTRIAL AREA JABALPUR JABALPUR MADHYA PRADESH 482010 | JABALPUR | MADHYA PRADESH | 482010 | Make: SOMAIYAS101
Model: WGC-9 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
25 May 2018, 3:00 pmClosed
Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 23 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Gas Cartridge Type Stored Pressure
Gas Cartridge Type Extinguishing Media Water Based Water Based
Foam Based
Powder Based
Carbon Dioxide Based
Clean Agent Expellant Medium CO2 Cartridge Based CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire Extinguisher Capacity (Kg) NA 1
2
NA 1/3 Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2
3
4.5
NA Water Based Fire Extinguisher Capacity 9 9 Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 14.0 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire false - Fire Extinguisher Suitable for Class -C Fire false - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire false - Performance Operating Temperature (° C) +5° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar
Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 30 Fire Rating for Class -A Fire Extinguisher 3A - 2/3 Fire Rating for Class -B Fire Extinguisher NA - Certification BIS Marking Yes - CM/L No.* with Validity Period 8200025296 21/11/2017 TO 20/11/2018 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. NTL/CVL/282127003 - Test Report Date 31/10/2017 - Name of the Lab NABL NTL - Address of the Lab DELHI - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 ANUBHA AGGARWAL 160002
Plot No 183 Industrial Area Phase 1 Chandigarh 23 15 EMD Required No ePBG Required No
89622
GEM/2018/B/12787
Portable Fire Extinguishers IS 15683
15 days
Chandigarh; Chandigarh
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 23 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Gas Cartridge Type Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Water Based Water Based | - | - | - |
| Foam Based | - | - | - |
| Powder Based | - | - | - |
| Carbon Dioxide Based | - | - | - |
| Clean Agent Expellant Medium CO2 Cartridge Based CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire Extinguisher Capacity (Kg) NA 1 | - | - | - |
| 2 | - | - | - |
| NA 1/3 Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA Water Based Fire Extinguisher Capacity 9 9 Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 14.0 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire false - Fire Extinguisher Suitable for Class -C Fire false - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire false - Performance Operating Temperature (° C) +5° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar | - | - | - |
| Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 30 Fire Rating for Class -A Fire Extinguisher 3A - 2/3 Fire Rating for Class -B Fire Extinguisher NA - Certification BIS Marking Yes - CM/L No.* with Validity Period 8200025296 21/11/2017 TO 20/11/2018 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. NTL/CVL/282127003 - Test Report Date 31/10/2017 - Name of the Lab NABL NTL - Address of the Lab DELHI - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 ANUBHA AGGARWAL 160002 | - | - | - |
| Plot No 183 Industrial Area Phase 1 Chandigarh 23 15 EMD Required No ePBG Required No | - | - | - |
Exempted
25 May 2018
15 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_89622.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .