Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-Finance PLOT N0 15 PEER MUSCHALLA ZIRAKPUR PATIALA PUNJAB 140603 | S A S NAGAR | PUNJAB | 140603 | L1 | Accepted-Finance The amount mentioned (after special rates provided by the L1). GST shall be extra as applicable | |
| 2 | L2₹59.5 L+₹19.1 L (47.3%)Accepted-Finance B 2 46 SECTOR 18 ROHINI DELHI 110089 | DELHI | NORTH WEST DELHI | DELHI | 110089 | L2 | Accepted-Finance The Quoted amount is exclusive of GST and comply as per tender terms and conditions. | |
| 3 | L3₹67.2 L+₹26.8 L (66.2%)Accepted-Finance | L3 | Accepted-Finance The Quoted amount is exclusive of GST and comply as per tender terms and conditions. | |
| 4 | Rejected-Technical 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | - | Rejected-Technical Not comply as per tender terms and conditions |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
1 Oct 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MANAGER ADMIN
KNOWLEDGE CITY SECTOR 81 MOHALI
Annual O and M of Heating, Ventilation and Air-conditioning System
2020_NABI_584856_1
NABI/7(234)/2020-Works
Open Tender
Electrical Works
Works
365 days
NABI CAMPUS
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
NABI
₹1.6 L
Yes
21 Dec 2020
18 Sept 2020
5 Oct 2020
18 Sept 2020
1 Oct 2020
18 Sept 2020
90 days
Annual Operation & Maintenance cost of HVAC system of NABI as per the scope of work defined in Volume-1 of tender document
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (500mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (450mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (300mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (250mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (200mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (150mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes(125mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (100mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (80mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (65mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (50mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (40mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (32mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes (25mm dia)
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes(20mm dia)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All kinds of soil) for Pipes, cables etc, not exceeding 80 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All kinds of soil) for Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre)
Aircon Technique Pvt Ltd
CHILL POINT ENGINEERS PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .