Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹2.2 L+₹34,000 (17.9%)Admitted-Finance HOUSE NO 97 VILL MAHUAWAN POST MAHUAWAN PACH DEURI GOPALGANJ BIHAR 841437 UDYAM BR 13 0011686 | GOPALGANJ | BIHAR | 841437 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | R P GLOBAL PROJECTS L2 | PLEXUS ELEVATORS AND COMPANY L1 |
|---|---|---|---|---|---|
| 1.00 | Repair to 02 nos Lifts Control Panel:-
by way of thorough inspection, testing, troubleshooting and rectification of faults in the electrical and electronic control system. The work shall include opening of the control panel, checking all internal wiring, connections, terminals, safety circuits, and functional components, and replacing any damaged, burnt, worn-out or defective parts to ensure safe and smooth lift operation. The job shall cover supply, installation, testing and commissioning of all key components typically installed in a standard lift control panel, including but not limited to Main Circuit Breaker (MCB/MCCB) of suitable rating (16–20A, 3-pole), Variable Frequency Drive (VFD) 10 kW, 415V, 3-phase, power contactors (18–22A AC3 duty), overload relays (13–18A), brake contactors (10A, 2-pole), isolation transformer (415V/110V, 500VA), emergency stop circuit integrated with safety loop, safety relays, power supply unit (24V DC, 2A), PLC/lift controller unit, current transformers (50/5A or 100/5A), HMI/control interface with push buttons and display system, panel cooling fan/heater arrangement, terminal blocks, fuses, auxiliary relays, alarm and indication lamps. Replacement of internal wiring with proper size cables (motor wiring 4–6 sq mm and control wiring 1.5–2.5 sq mm) shall also be included wherever required. The complete job shall be executed as per OEM recommendations, safety norms and site requirements. The work includes cost of materials, labour charges, transportation, installation, testing, commissioning and all applicable taxes, complete in all respects. | 1 | job | 2,24,000 ₹2,24,000 | 1,90,000 ₹1,90,000 Lowest |
Tender Value
₹2.3 L
EMD Value
₹4,500
Closing Date
28 Sept 2026, 12:00 pmClosed
EXECUTIVE ENGINEER M AND H DIVISION DODA
KHELLANI DODA
Repairs to 2 nos Patient Passenger lifts in CHC Gandoh
2026_PWDJK_322351_1
MHDD/TS/2026-27/34
Open Tender
Repair and Maintenance Works
Turn-key
15 days
CHC GANDOH
AS PER SBD
2 documents required · 2 mandatory
₹500
EXECUTIVEV ENGINEER M AND H DIVISION DODA
₹4,500
EXECUTIVE ENGINEER M AND H DIV DODA
29 Sept 2026
25 Aug 2026
28 Sept 2026
25 Aug 2026
28 Sept 2026
25 Aug 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repair to 02 nos Lifts Control Panel:-
by way of thorough inspection, testing, troubleshooting and rectification of faults in the electrical and electronic control system. The work shall include opening of the control panel, checking all internal wiring, connections, terminals, safety circuits, and functional components, and replacing any damaged, burnt, worn-out or defective parts to ensure safe and smooth lift operation. The job shall cover supply, installation, testing and commissioning of all key components typically installed in a standard lift control panel, including but not limited to Main Circuit Breaker (MCB/MCCB) of suitable rating (16–20A, 3-pole), Variable Frequency Drive (VFD) 10 kW, 415V, 3-phase, power contactors (18–22A AC3 duty), overload relays (13–18A), brake contactors (10A, 2-pole), isolation transformer (415V/110V, 500VA), emergency stop circuit integrated with safety loop, safety relays, power supply unit (24V DC, 2A), PLC/lift controller unit, current transformers (50/5A or 100/5A), HMI/control interface with push buttons and display system, panel cooling fan/heater arrangement, terminal blocks, fuses, auxiliary relays, alarm and indication lamps. Replacement of internal wiring with proper size cables (motor wiring 4–6 sq mm and control wiring 1.5–2.5 sq mm) shall also be included wherever required. The complete job shall be executed as per OEM recommendations, safety norms and site requirements. The work includes cost of materials, labour charges, transportation, installation, testing, commissioning and all applicable taxes, complete in all respects. | 1 | job | 100 | ₹100 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.25 MB
BOQ_1080061.xls
BOQ • 0.29 MB
Cor3.pdf
PDF • 0.51 MB
Cor2.pdf
PDF • 0.51 MB
cor1.pdf
PDF • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .