Loading…
Loading…
Tender Value
₹3.3 Cr
EMD Value
₹6.6 L
Closing Date
25 Jun 2026, 5:00 pm
Gopal Prasad Singh
EE PDA
1ST FLOOR, UDYOG BHAWAN EAST GANDHI MAIDAN PATNA 800004
Gopal Prasad Singh
EE PDA
(Re-Tender) Repair, electrical work, painting and drainage system work of the administrative building and hostel located in BAMETI campus.
133773
NIT 16/TEN/IDA/26
Open Tender
CIVIL
Patna
• REGISTRATION
Class
• ELECTRICAL LICENCE REGISTRATION
• "LEGAL STATUS OF BIDDER
ITB clause 4.3 (a)
• PERMANENT ACCOUNT NUMBER (PAN)
• GST REGISTRATION
• "COST OF BOQ
(e payment only)"
• EARNEST MONEY DEPOSIT (BID SECURITY)
• WORK EXPERIENCE OF SIMILAR NATURE (Multistoried Building Work)
Section 1 ITB 4.5 (A) (b) of SBD
• "QUANTITY WISE EXPERIENCE
(EXECUTED QUANTITY IN ANY ONE FINANCIAL YEAR DURING LAST FIVE YEARS ITB clause 4.5 (A)( c ), 4.5 (A) (d) & 4.5(A)(e))
MINIMUM QUANTITY / AMOUNT AS PRESCRIBED IN SBD
RCC+PCC : 43.50 Cum
Earth Work+Local Sand : 177.50 Cum
Electrical+HVAC Work : Rs. 30,94,597.00
PHE Work : Rs. 11,44,370.00
Audio Video Work : Rs. 23,39,265.00
Aluminium Work : 225.00 Kg
Wall Paneling Work : 140 Sqm
False Ceiling Work : 763.50 Sqm
• "ANNUAL FINANCIAL TURN OVER OF LAST FIVE YEARS
ITB clause 4.5 (A)(a)
(Balance Sheet, Profit & Loss And Audit Report duly audited by CA)"
"FY 2020-2021 Amount To be entered (Rs in Lakhs)"
"FY 2021-2022 Amount To be entered (Rs in Lakhs)"
"FY 2022-2023 Amount To be entered (Rs in Lakhs)"
"FY 2023-2024 Amount To be entered (Rs in Lakhs)"
"FY 2024-2025 Amount To be entered (Rs in Lakhs)"
• BANKER'S CERTIFICATE EVIDENCE OF ACCESS TO OR
AVAILABILITY OF CREDIT FACILITIES (10% OF PROJECT COST)
Section 1 ITB 4.2 ( i ) of S.B.D
• BIDDING CAPACITY (BC=A*N*3-B)
Section 1 ITB 4.7 of S.B.D"
• (A) AMOUNT OF EXISTING COMMITMENTS AND ONGOING WORKS
• (B) AMOUNT OF WORK FOR WHICH BID ALREADY SUBMITTED
• "AFFIDAVIT
• CHARACTER CERTIFICATE
• UNDERTAKING
(i) Investment of minimum cash up to 25% of the value of the work during implementation of the contract.
Section 1 ITB 4.2 (ii) of SBD
• (ii) Bid Validity : 120 days
Section 1 ITB 15.1 of SBD
• LITIGATION HISTORY
Section 1 ITB 4.3 ( j ) of SBD"
• "PROPOSED METHODOLOGY AND PROGRAMME OF CONSTRUCTION
Section 1 ITB 4.3 ( l ) of S.B.D"
• TECHNICAL PERSONNEL
Section 1 ITB Clause 4.5 B (b)"
• LIST OF KEY PLANTS & EQUIPMENTS
Section 1 ITB 4.5 B (a)"
CIVIL
ITEM RATE
L1
1
24 documents required · 24 mandatory
₹11,800
Processing Fee: 5900
₹6.6 L
IDA, 1st Floor, Udyog Bhawan, East Gandhi Maidan, Patna 800004
12 Jun 2026
12 Jun 2026
27 Jun 2026
12 Jun 2026
25 Jun 2026
12 Jun 2026
15 Jun 2026
INFRASTURUCTURE DEVELOPMENT AUTHORITY First Floor, Udyog Bhawan, East of Gandhi Maidan, Patna
TECHNICAL BID SHEET
TENDER NUMBER 16/TEN/IDA/26 DATE OF ISSUE OF TENDER 27.05.2026
NAME OF WORK (Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य COST OF WORK AS PER BOQ Rs. 33,115,805.00
BID SECURITY (EARNEST MONEY DEPOSIT) AMOUNT Rs. 662,500.00 COMPLETION PERIOD IN MONTHS 6.0
NAME OF TENDERER ALL COLOURED CELL IS TO BE FILLED ACCORDINGLY
ADDRESS, E-MAIL & MOBILE NUMBER OF TENDERER
S.N. ITEMS REQUIREMENT REMARKS
1 REGISTRATION (Any Contractor Registered in appropriate category with Central Government / Any State Government / Any Public Sector Undertakings or an Agency of National or International repute may tender but Registration with Infrastructure Development Authority will be essential after issue of Letter Of Acceptance.) Department
Registration No.
Date of Validity
2 ELECTRICAL LICENSE REGISTRATION Attach Valid Self Electrical License Or Sub Contractor's Electrical License With Affidavit (Attach An Affidavit As Per Format Prescribed In SBD-Annexure III, On Or After Date Of Tender, Duly Attested By An Executive Magistrate). Department
Registration No.
Date of Validity
3 LEGAL STATUS OF BIDDER Section 1 ITB 4.3 (a) of S.B.D (i) Individual/Partnership/Pvt. Ltd./Public Ltd/Joint Venture
(ii) Place of Registration.
(iii) Principal Place of Business
(iv) Power of Attorney of Signatory Bid
4 JOINT VENTURE (Bids From Joint Ventures Are Acceptable Only Above Rs. 10.00 Crores Project) The tenderer have to submit the Joint Venture documents as per eligibility criteria & other instructions issued vide Road Construction Department Letter No. 8131 (S) dated: 24.07.2012.
5 PERMANENT ACCOUNT NUMBER (PAN) Attach Copy of PAN
6 GST REGISTRATION Attach Copy of GST
7 COST OF BOQ (e payment only) Rs. 11,800.00 (Attach e-payment receipt of BOQ)
8 EARNEST MONEY DEPOSIT (BID SECURITY) Earnest Money Deposit (Bid Security) will be accepted only in online mode (Internet Payment Gateway). No other forms of Earnest Money Deposit (Bid Security) will be accepted. Amount To Be Entered (Rs. In Lakhs) Attach e-payment of Earnest Money Deposit (Bid Security).
9 WORK EXPERIENCE OF SIMILAR NATURE (Interior Work) Section 1 ITB 4.5 (A) (b) of SBD The completion certificate shall be issued by employer not below the rank of Executive Engineer or Equivalent.
10 QUANTITY WISE EXPERIENCE Section 1 ITB 4.5 (A) ( c ) of SBD MINIMUM QUANTITY / AMOUNT AS PRESCRIBED IN SBD
RCC+PCC : 43.50 Cum
Earth Work+Local Sand : 177.50 Cum
Electrical+HVAC Work : Rs. 30,94,597.00
PHE Work : Rs. 11,44,370.00
Audio Video Work : Rs. 23,39,265.00
Aluminium Work : 225.00 Kg
Wall Paneling Work : 140 Sqm
False Ceiling Work : 763.50 Sqm
11 ANNUAL FINANCIAL TURN OVER OF LAST FIVE YEARS ITB Clause 4.5 (A)(a) (Balance Sheet, Profit & Loss And Audit Report Duly Audited By CA) FY 2020-2021 Amount To be entered (Rs in Lakhs)
FY 2021-2022 Amount To be entered (Rs in Lakhs)
FY 2022-2023 Amount To be entered (Rs in Lakhs)
FY 2023-2024 Amount To be entered (Rs in Lakhs)
FY 2024-2025 Amount To be entered (Rs in Lakhs)
12 BANKER'S CERTIFICATE EVIDENCE OF ACCESS TO OR AVAILABILITY OF CREDIT FACILITIES (10% OF PROJECT COST) Section 1 ITB 4.2 ( i ) of S.B.D Certificate Issued By Bank As Per Format Prescribed In Sec-2 Of SBD, On Or After Date Of Tender
13 BIDDING CAPACITY (BC=A*N*3-B) Section 1 ITB 4.7 of S.B.D A = Maximum value of civil engineering works executed in any one year during the last five years (updated to the price level of the year indicated in Appendix) taking into account the completed as well as works in progress. N = Number of years prescribed for completion of the works for which bids are invited. B = Value (updated to the price level of the year indicated in Appendix) of existing commitments and on-going works to be completed during the next 06 Months(period of completion of the works for which bids are invited).
14 (A) AMOUNT OF EXISTING COMMITMENTS AND ONGOING WORKS Attach As Per Sec. 2- 1.4 (A) Of SBD, On Or After Date Of Tender (Bidder must decleare themselve their all exising commitment concealment of any fact shall be sufficient cause for rejection)
(B) AMOUNT OF WORK FOR WHICH BID ALREADY SUBMITTED Attach As Per Sec 2- 1.4 (B) Of SBD, On Or After Date Of Tender
15 AFFIDAVIT (I) Attach An Affidavit As Per Format Prescribed In Sec-2 Of SBD, On Or After Date Of Tender, Duly Attested By An Executive Magistrate.
(II) Attach An Affidavit As Per NIT, On Or After Date Of Tender, Duly Attested By An Executive Magistrate.
16 CHARACTER CERTIFICATE Attach a Valid Character Certificate of Tenderer Issued By Competent Authority.
17 UNDERTAKING (i) Investment of minimum cash up to 25% of the value of the work during implementation of the contract. Section 1 ITB 4.2 (ii) of SBD (I) Attach An Undertaking As Per Format Prescribed In Sec. 2 Of SBD.
(ii) Bid Validity : 120 days Section 1 ITB 15.1 of SBD (II) Attach An Undertaking As Per Format Prescribed In Sec. 8 Of SBD.
18 LITIGATION HISTORY Section 1 ITB 4.3 ( j ) of SBD As Per Format Prescribed In Sec. 2-1.11 Of SBD On Or After Date Of Tender.
19 PROPOSED METHODOLOGY AND PROGRAMME OF CONSTRUCTION Section 1 ITB 4.3 ( l ) of S.B.D Attach Descriptions,Drawings And Charts As Necessary.
20 TECHNICAL PERSONNEL Section 1 ITB Clause 4.5 B (b) Attach As Per Sec-2-1.6 Of SBD. Attach Necessary Certificate And Current Affidavit Of Both Employee And Employer On And After Date Of Tender, Duly Attested By An Executive Magistrate.
21 LIST OF KEY PLANTS & EQUIPMENTS Section 1 ITB 4.5 B (a) Attach As Per Sec 2-1.5 Of SBD (Max. Age 5 Years). Attach Owned Voucher/Cash Memo/Invoice And Affidavit In Case Of Leased/Hire On And After Date Of Tender, Duly Attested By An Executive Magistrate.
I, the undersigned, do hereby certify that all the statements made in the required attachements are true and correct.
INFRASTRUCTURE DEVELOPMENT AUTHORITY
(A GOVERNMENT OF BIHAR UNDERTAKING)
(Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य
QUOTING SHEET FOR BIDDERS
Name of Contractor
Address of Contractor
E-mail ID of Contractor Whatsapp Enabled Mobile Number
NIT - 16/TEN/IDA/26
Sl no. Description Estimated Amount Rate Quoted by Contractor
% Above/Below TOTAL QUOTED AMOUNT Rs.(In Figure) TOTAL QUOTED AMOUNT Rs.(In Words)
1 Total Schedule Amount (Rs.) 22910669.883174147
2 Total Non-Schedule Amount (Rs.) To be Quoted!
TOTAL AMOUNT Rs. 33115805
(Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य
S.No. Particular Amount
1 Schedule Items 22910669.883174147
2 Non-Schedule Items
(Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य
SCHEDULED ITEMS
S.No. BCD SOR-22 DESCRIPTION OF ITEMS Unit Quantity Rate Amount
Civil Work (Schedule Items)
1 2.8.1 Earthwork in excavation in foundation trenches or drains(not exceeding 1.5m in width or 10 sqm on plan)including dressing of sides and ramming of bottom lift upto 1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m All kinds of soil. Cum. 250 360.75 90187.5
2.26 Filling available excavated earth(including rock)in trenches ,plinth,sides of foundation etc.in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead. Cum. 25 123.9 3097.5
2.28 Supplying and Filling in plinth with local sand and under floors including watering ,ramming consolidating and dressing complete. Cum. 80 287.3 22984
4 15.2 Demolishingcementconcreteincludingdisposalofmaterialwithin 50 metre lead:
S.H. III: MASONRY WORK
5 6.1A Brick work with bricks of class designation 100A in foundation and plinth in:
6.1.12/1 cement mortar 1:4 (1 cement : 4 coarse sand) cum 25 5017.9 125447.49999999999
6 6.3A Extra for Brick work in superstructure above plinth level upto floor V level cum 840.25 21006.25
7 6.21A Extra for providing and placing in position 2Nos. 6mm dia. MS bars at every third course of half brick masonry (with F.P.S. brick) sqm. 113.6 2840
SH-IV: CONCRETE WORK
8 5.37 Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended roportions as per IS : 9103 to accelerate/retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer - in - charge. M-25 grade Reinforced cement concrete by using 330 kg of cement per cum of concrete.
A 5.37.1 All works up to Plinth level cum 20 5562.4 111248
B 5.37.2 All works above Plinth level up to floor five level. cum 12 6372 76464
9 5.34 Add or deduct for providing richer or leaner mixes respectively at all floor levels.
10 5.9 Centering and shuttering including strutting,propping etc and removal of form for:
A 5.9.1 Foundation,footing,Bases of column etc for mass concrete. sqm 12 211.6 2539.2
B 5.9.3 suspended floors sqm 20 437.5 8750
C 5.9.5 Lintels,Beams,Plinth beams,girders,bressumers and cantilevers. sqm 24 404.7 9712.8
D 5.9.6 Columns,Pillars,Piers,Abutments,Posts and struts. sqm 25 494.4 12360
SH-V: STEEL WORK
5.22 Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding complete.
A 5.22.7A Thermo-Mechanically Treated barsTMTC-500-8mm dia Kg. 1200 94.5 113400
B 5.22.7B Thermo-Mechanically Treated barsTMTC-500-10mm dia Kg. 2500 92.6 231500
C 5.22.7C Thermo-Mechanically Treated barsTMTC-500-12mm dia Kg. 3000 90.8 272400
S.H. VI : WOOD & ALUMINIUM WORK
12 9.1 Providing wood work in frames of doors, windows, clerestroy windows and other frames, wrought framed and fixed in position:
9.1.1 Second class teak wood cum 5.5 120526.6 662896.3
9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
9.21.1 35 mm thick including ISI marked stainless steel butt hinges with necessary screws sqm 30 1775.3 53259
14 9.74 Providing and fixing bright finished brass tower bolt (barrel type) with necessary screws etc. complete.
9.103 Providing and fixing bright finished brass 100mm mortice latch and lockwith 6 lever handles with necessary screws etc. complete (best make of approved quality) Each 15 655.4 9831
9.81 Providing and fixing bright finished brass handle with necessary screws etc. complete.
9.82 Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. complete. Each 21 108.1 2270.1
9.88 Providing and fixing chromium plated brass 100 mm latch and lock with 6 levers and a pair of handles of approved quality with necessary screws etc. complete Each 6 733.1 4398.6
9.84 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564,embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete Each 21 810.1 17012.100000000002
20 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubula sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 450 418.4 188280
21 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
21.3.2 With float glass panes of 5.50 mm thickness(weight not less than 12.50 kg/sqm Sqm 300 1115.1 334530
22 9.127 Providing&Fixing decorative high pressure laminated sheet of plain/wood graining loss/matt /suede finish with high density protectivesurface layer and reverse side of adhesive bonding quality conforming to IS:2046 Type S, including cost of adhesive of approved quality.
S.H. VII : FLOORING WORK
23 11.72 Providing desination 100 A one brick flat soling joints filled with local sand including cost of watering texes, roualty all complete as per building specification and direction of E/l. sqm 150 283.3 42495
24 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing etc. complete at all levels.
8.2.2 Granite of any colour and shade
8.2.2.2 Area of slab over 0.50 sqm sqm 50 4401.2 220060
8.3 Extra for providing edge moulding to 19 mm thick marble stone counters, Vanities etc. over item no. 8.2 mm thick marble stone counters, Vanities etc. over item no. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Granite work
26 11.41A Providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorptions less than0.08% and conforming to IS : 15622 of approved brand & manufacturer in all colours and shades, laid on 20mm thick cement motar 1:4 (1cement : 4 coarse sand) jointing with grey cement slurry @3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.
A 11.41A.2 Glazed Vitrified floor tile polished finish of size
B 11.41A.3 Glazed Vitrified tile Matt/ Antiskid finish of size
11.41A.3.1 Size of Tile 600 x 600 mm (for floor toilet) sqm 150.72 1054.3 158904.096
27 7.23 Stone work (machine cut edge) forwall lining etc. (veneer work) over 12 mm thick be dofcement lime mortar1:1:6 (1cement:1 lime putty: 6 fine sand ) including pointing in white cement mortar 1:2(1whitecement: 2 stonedust) with an admixture of pigment matching the stone shade: (To be secured to the backing bymeans of cramps which shall be paid for seperately)
A 7.23.1 Red sand stone- exposed face fine dressed with rough backing
B 7.23.2 White sand stone
28 14.72 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Sqm. 2500 178.3 445750
29 25.3 Cleaning the sand stone surface and removing dirt, dust, bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agent as approved by chaeological Survey of India/ Engineer-incharge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building/ structure, all as per direction of Engineer-in-charge (The rate is inclusive of all materials & labours involved except scaffolding). sqm 1500 75.3 112950
30 25.4 Providing and applying antifungal wash treatment using 3% solution of sodium pentachlorophenate, of reputed brand and manufacturer,on cleaned sand stone surface at desired locations as per direction of Engineer-in-charge (The rate is inclusive of all materials & labours involved except scaffolding). sqm 1500 29.8 44700
31 7.25 Providing and fixing gunmetal cramps of required shape for anchoring stonewall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2(1cement: 2finesand) including making the necessary chases.
32 13.11 Cement plaster in course sand 12mm cement plaster of mix :
13.11.4 1:6 (1Cement : 6 Coarse sand) Sqm. 1200 141.5 169800
13.13 20mm cement plaster of mix :
13.13.4 1:6 (1 cement : 6 coarse sand) sqm 1500 192.1 288150
S.H. IX : FINISHING WORK 0
34 13.74 Removing white or colour wash by scraping and sand papering and preparing the surface smooth including necessary repair scratches etc. complete sqm 3000 7.7 23100
35 13.93 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.93.1 Two or more coats on new work Sqm 1500 84.5 126750
13.80 A.1 Providing and applying white cement based putty of average thickness 1mm, of approved brand andmanufacturer, over the plasteredwall surface to prepare the surface even and smooth complete. Sqm 3000 81.1 243299.99999999997
13.92 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.
13.92.1 Two or more coat on new surface. Sqm 3000 86.4 259200.00000000003
38 13.116A Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this drybsurface is again fine wet rubbed smooth, which is further allowedto dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time Sqm 900 786.9 708210
39 2.37. DilutingandinjectingchemicalemulsionforPOSTCONSTRUCTIONAL anti-termites' treatrnent(including the cost of chemical emulsion)
2.37.5 Treatment at points of contact ot wood work by chemical emulsion chlordane. (in oil or kerosene based solution)® 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. metre 600 270.2 162120
SH-X: FALSE CEILING WORK
40 12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made up of special sections power pressed from M.S. sheet and galvanized in accordance with zinc coating of 120 gms/sqm as per IS:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts to the angle hanger of 25x25x5 mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connection clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of
20 mm and 30 mm long, the perimeter of ceiling fixed to wall/ partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long drive-all screws @230 mm interval including jointing and fixing to a flush finish of tapered and square edges of the gypsum board with recommended filler, paper tapes, finishers and two coats of primer suitable for gypsum board as per manufacturers specification and also including the coat of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per the drawing and specification and direction of the the Engineer-in-charge but excluding the cost of painting.
12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board Sqm 600 993 595800
41 12.62 Extra for any sunk or raised moulding in the plaster of paris (Gypsum anhydrous ) ceilng .All complete as per specification and direction of E/I. Sqm 283 169800
42 26.27 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture,design and pattern. The tiles should have Humidity Resistance (RH) of 99%,Light Reflectance≥85%,Thermal Conductivity k=0.057 w/m K,Fire Performance as per (BS 476 pt-6 & 7)in true horizontal level suspended on interlocking T- Grid of hot dipped all round galvanised iron section of 0.33mm thick(galvanized @120gsm)comprising of main T runners of 15x32mm of length 3000mm,cross T of size15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item(galvanised @80gsm) 50mm long 8mm outer diameter M-6 dash fasteners,6mm diameter fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm,spaced at 1200mm centre to centre along main 'T'. The system should rest on periphery walls/partitions with the help of GI perimeter wall angle of size 24x24x3000mm made of 0.40 mm thick sheet, to be fixed to the wall with the help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint,for all heights. The work shall be carried out as per specifications,drawings and as per directions of the engineer-in-charge.
26.27.2 With 20mm thick beveled tegular mineral fibre false ceiling tile (NRC0.7). Sqm. 477.36 2120.7 1012337.352
43 12.54X Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join,C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with
12.54X.1 GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (m nimum), including factory painted after bending. sqm 450 1626.3 731835
SH-XI: WATERPROOFING WORK
44 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C kitchen and thelike consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions. (ii) IInd course of 20mm cement plaster 1:3 (iii) litrd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area. (iv) lvth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC shet should be 100mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). sqm 351.5 480.6 168930.9
22.2 Providing and fixing APP (Atactic Polypropylene Polymer ) modifieid prefabricated five layer 3mm thick water proofing membrane,black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sq. mtr. by the same membrane manufacture of density at 25degree centigrate,0.87 -0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc. and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be : joint strength in longitudinal and transvers direction at 23 degree centigrate as 650 / 450 N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150degree . Cold flexibility shall be upto -2 degree centigrate when tested in accordance with ASTM, D-5147 . The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
46 22.21 Extra for covering top of membrane with Geotexitle , 120 gsm non woven, 100 5% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heatiig the membrane by Butane torch as per manufactures recommendation. sqm 85.2 255600
47 12.38 Providing gola 75 x 75mm in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement: 3 fine sand) as per standerd design:
12.38.1 In 75x75mm deep chase sqm 66 198000
48 12.39 Making khurras 45 x 45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20mm nominal size) overP.V.C sheet 1mx 1m x 400 micron, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement rounding the edes and making and finishing the outlet complete. Each 190 189.4 35986
49 12.52 Grading roof for water proofing treatment with
12.52.2 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate cum 300 3932.2 1179660
50 15.41 Dismantling cement asbestos,Celotaxorotherhardboardceiling or partitionwalls includingstackingof serviceablematerialsand disposal of unserviceable materials within 50 metres lead sqm 23.7 71100
51 CARRIAGE OF MATERIAL
A Coarse sand ( lead of 2K+55 P from Koilwar ) Cum. 200 1550.08 310016
B Local Sand ( Lead local 1K+2P) Cum. 120 310.469152 37256.298240000004
C Stone chips ( lead By Rail from Manpur) Cum. 300 1427.28 428184
D Red Bricks 100A(local lead 1K+7P) Per 1000 1200 1140.59 1368.708
E Cement 5 km P MT 518.09 62.1708
52 EXTRA FOR MATERIALS
A Add for Cement (PSC) MT 120 265.41 31849.200000000004
B Add for Bricks Per 1000 1606.89 1928.2680000000003
TOTAL FOR CIVIL WORK=A 13581916.483040001
SECTION -2 PLUMBING WORKS
S.H. - I : Sanitary Fixture & CP Fittings
53 17.1 Providing and fixing water closet squatting pan (Indian Type W.C. Pan) with 100mm sand cast iron P or S trap. 10 litre low fixtures complete , including cutting and making good the walls and level white P.V.C flushing cistern, including flush pipe, with manually controlled device (handle lever) confirming to IS 7231, with all fittings and floors wherever required.
17.1.1 White vitreous china Orissa pattern W.C pan of size580 X 440 mm with integral type foot rests. Each 16 4470.9 71534.4
17.3 Providing and fixing white vitreous china pedestal type water coset (Europenan type) with seat and lid , 10 litre low level white vitreous china flusing cistern & C.P flush bend with fittings & C.I.brackets , 40 mm flush bend, overflow arrangment with specials of standard make and mosquito proof coupling of approved municiple desine complete, including painting of fittings and brackets ,cutting and making good the wall and floiirs wherever required.
17.3.1 W.C pan with ISI marked white solid plastic seat and lid Each 8 5504.3 44034.4
17.4 Providing and fixing .white vitreous china flat back or wall corner type lipped front urinal basin of size 450 x 260 x 350mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and CP brass spreaders with brass unions and GI clamps complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required.
17.4.2 Range of two urinal basin with 5 litre white P.V.C. automatic flushing cistern. Each 8 5733.3 45866.4
17.7 Provding and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, , 32 mm C.P. brass waste of standard pattern, including paintings of fittings and brackets, cutting and making good the .wall wherever required.
17.7.4 White vitreous china flat back wash basin size 550X400mm with a single15mm CP brass pillar tap Each 32 2135.8 68345.6
17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required :
17.9.1 White glazed fire clay kitchen sink of size 600x450x250 mm Each 4 2778 11112
17.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever as required. :
17.10.1 Kitchen sink with drain board
17.10.1.1 510x1040 mm bowl depth 250 mm Each 1 5231.5 5231.5
17.31 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete. Each 32 1068.5 34192
17.33 Provding and fixing 600X120X5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with CP brass brackets and guard rail complete fixed with 40 mm long screws ,rawl plug etc, complete. Each 32 713.3 22825.6
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
17.28.2 Flexible pipe
17.34 Providing and fixing toilet paper holder.
17.7 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
A 17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. Each 32 325.1 10403.2
B 17.70.2 Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. Each 20 325.1 6502
17.71 Proving and fixing PTMT liquid soap container 109mm wid, 125mm high and 112 mm distancefrom wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour , weighting not less than 105 gms. Each 16 146.3 2340.8
17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. Each 16 204.7 3275.2
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. Each 16 424 6784
8.1 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and 0
8.10.2 Granite stone of approved shade Sqm 16 3542.9 56686.4
18.21 Providing and fixing PVC Unplasticised Connection pipe with brass ions :
18.21.2 45 cm length
18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 0
18.49.1 15 mm nominal bore Each 24 434.2 10420.8
18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS :8931
18.51.1 15 mm nominal bore Each 16 708.4 11334.4
18.52 Providing and fixing C.P. brass stop cock (concealed) of approved standard design and of approved make conforming to IS:8931 0
18.52.1 15 mm nominal bore Each 16 594.8 9516.8
18.53 Providing and fixing C.P. brass angle valve of approved quality conforming to IS :8931 0
18.58 Providing and fixing PTMT grating of approved quality and colour. 0
18.58.1 Rectangular type with openable circular lid
18.58.2.1 150 mm nominal size square 100mm diameter of the inner hinged round grating Each 16 169.7 2715.2
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. Each 16 299.4 4790.4
TOTAL FOR SANITARY FIXTURE & C.P FITTINGS =B 484012.30000000005
S.H. - II : WATER SUPPLY & RAIN WATER PIPE
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
A 18.7.2 20 mm dia. Nominal outer dia pipes Mtr. 30 233.9 7017
B 18.7.3 25 mm dia. Nominal outer dia pipes Mtr. 45 317.3 14278.5
C 18.7.4 32 mm dia. Nominal outer dia pipes Mtr. 40 395.2 15808
D 18.7.5 40 mm dia. Nominal outer dia pipes Mtr. 70 538.4 37688
E 18.7.6 50 mm dia. Nominal outer dia pipes Mtr. 75 791 59325
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.
Concealed work including cutting chases and making good the walls etc.
A 18.8.1 15mm nominal outer dia pipes Mtr. 90 278.2 25038
B 18.8.2 20mm nominal outer dia pipes Mtr. 70 350.8 24556
C 18.8.3 25mm nominal outer dia pipes Mtr. 95 463.1 43994.5
18.9 Providing and fixing Chlorinated polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, This includes jointing of pipes & fittings with one step CPVC solvent cement trenching,refilling and testing of joints complete as per direction of engineer in charge.
18.9.5 40 mm dia. Nominal outer dia pipes Mtr. 45 477.6 21492
18.13 Making connecting of G.I. distribution branch with G.I. Main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.
18.13.1 25 to 40 mm Nominal bore Mtr. 40 446.7 17868
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
A 18.17.1A 20 mm nominal bore Each 10 465.4 4654
B 18.17.1 25 mm nominal bore Each 10 532.3 5323
C 18.17.2 32 mm nominal bore Each 2 589.9 1179.8
D 18.17.3 40 mm nominal bore. Each 2 707.3 1414.6
E 18.17.4 50 mm nominal bore. Each 2 878.2 1756.4
18.19 Providing and fixing metal non-return valve of approved quality.
18.19.3 40 mm nominal bore
A 18.19.3.1 Horizontal Each 1 815 815
B 18.19.3.2 Vertical Each 1 1049.2 1049.2
18.46 Providing and fixing G.I. union in G.I.pipe including cutting and threading the pipe and making long screws etc.complete
A 18.46.2 20 mm dia. Nominal bore Each 12 185.6 2227.2
B 18.46.3 25 mm dia. Nominal bore Each 14 265.9 3722.5999999999995
C 18.46.4 32mm dia. Nominal bore Each 4 306 1224
D 18.46.5 40mm dia. Nominal bore Each 8 419.7 3357.6
E 18.46.6 50mm dia. Nominal bore Each 6 565.6 3393.6000000000004
12.78 Providing and fixing on wall face unplasticised-PVC (working pressure 4 Kgf per sqm) rain water pipes conforming to IS:4985including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion
12.78.2 110mm diameter Mtr. 292 257.5 75190
12.79 Providing and fixing on wall face unplasticised -PVC moulded fittings/ accessories for unplasticised PVC rainwater pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
12.79.1 Coupler
B 12.79.5.2 110mm bend Each 132 5544
12.79.6 Shoe (Plain)
12.8 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S screws of required length including cutting brick work and fixing in cement mortar 1:4( 1 cement: 4 coarse sand) and making good the wall etc. complete.
12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 14 47.9 670.6
TOTAL FOR WATER SUPPLY & RAIN WATER PIPE =C 443425.8999999999
S.H. III : DRAINAGE SYSTEM
2.1 Excavating trenches of required width for pipes, cables etc including excavation for sockets and dressing of sides, ramming of bottoms depth upto 1.5m ,including getting out the excavated soil , and then returning the soil as required,in the layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering and desposing of surplus excavated soil as dirceted within a lead of 50m
2.10.1.2 pipes cables etc exceeding 80mm dia but not exceeding 300 mm dia Mtr. 400 391.7 156680
19.6 Providing and laying non -pressure NP2 class(light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joints etc. complete
B 19.6.4 300 mm dia. R.C.C. pipe Mtr. 200 780 156000
19.7 Constructing brick masonary manhole in cement mortar 1:4 (1 cement, 4 coarse sand.) R.C.C. top slab with1:2:4 mix(1 cement, 2 coars e sand, 4 graded stone aggregate 20 mm nominal size) foundation cocrete 1:4:8 mix (1cement, 4 coarse sand, 8 graded stone aggregate 40 mm nominal size.) inside plastering 12 mm thick with cement mortar 1:3 (1 cement, 3 coarse sand.) finished with floating coat of neat cement and making channels in cement concrete 1:2:4. finished with floating coat of neat cement complete as per standard design.
19.7.1 Inside size 90x80cm and 45 cm deep including C.I. cover with frame ( light duty) 455x610 mm internal diamension tatal weight of cover and fram to be not less than 38 kg (weight of cover23 kg and weight of frame 15 kg )
19.7.1.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 45 7914.7 356161.5
88 24.1 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
24.1.1 All types of soil
89 24.2 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre and upto 150 metre depth below ground level.
24.2.1 All types of soil
90 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
24.3.1 100 mm nominal size dia Mtr. 90 546.1 49149
24.3.2 150 mm nominal size dia Mtr. 60 660.1 39606
91 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
24.4.1 100 mm nominal size dia Mtr. 60 573.1 34386
92 24.8 Gravels packing in tubewell construction in accordance with IS 4097 including providing graval fine/medium/coarse,in required grading & sizes as per actual requirement,all complete as per direction of Engineer-in charge. cum 14.16 1343.2 19019.712
93 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hrs 96 916.8 88012.79999999999
24.13 Providing & fixing suitable size threaded mild steel cap or spot welded plate to the top of borewell housing/ casing pipe ,removable as per requirement,all complete for borewell of,
94 24,14 Providing & fixing MS clamp of required dia to the top of housing/casing pipe of,removable as pe tubewell as per IS;2800(part-I), including necessary bolts & nuts of required size complete
95 24.15 Providing & fixing Bail plug/ bottom plug of required dia to the bottom of pipe assembly as per IS;2800(part-I),
TOTAL FOR DRAINAGE WORK =D 1361301.8120000002
TOTAL FOR PLUMBING WORK =(B+C+D) 2288740.012
Total civil work (E) Total 16721323.683174148
Electrical (Schedule Items)
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required.
a 1.3.3 Group C Each 150 1146 171900
2 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. Mtr 250 309 77250
3 1.6 Wiring for light/ power plug with 4 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in sufface / recessed medium class PVC conduit along with 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. Mtr 450 523 235350
4 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a 1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Mtr 150 201 30150
b 1.7.2 2 X 2.5 sq. mm + 1X 2.5 sq. mm earth wire Mtr 150 246 36900
5 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ reeessed PVC conduit as required.
6 1.24 Supplying and fixing following modula'r switch/ socket on the existing modular plate & switch box including connections but excluding modular plate.etc. as required.
a 1.24.1 5/6 amps switch Each 50 82 4100
b 1.24.3 15/16 amps switch Each 25 139 3475
c 1.24.4 3 pin , 5/6 amps socket outlet Each 50 112 5600
d 1.24.5 6 pin, 15/16 amps socket outlet Each 25 183 4575
7 1.27 Supplying and fixing following size/ modules, Gl box along with modular base and cover plate for modular switches in recess etc as required.
a 1.27.2 3 Module (100mm X 75mm) Each 25 266 6650
8 2.33 Supplying and fixing , following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as lncomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBS)
a 2.33.4 12 way, Double door, l/C 1604, MCCB Each 1 20409 20409
9 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required'
a 2.4.1 100 A , 30 KA, FPMCCB Each 1 8172 8172
10 2.12 Supptying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete w
a 2.12.1 6 A to 32'A, Single pole Each 25 237 5925
11 2.25 Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Each 8 3008 24064
12 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required. set 2 16675 33350
13 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. mtr 100 144 14400
14 5.15 Supplying and fixing fotrlowing types LED Flood / Track light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required.
15 5.1 Supplying and fixing 4' X 18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required. Each 148 521 77108
16 5.2 Supplying and fixing 2' X 9 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. Each 65 492 31980
17 5.8 Supplying and fixing surface / recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
18 5.9 Supplying and fixing recess / surface mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. Each 443 2663 1179709
19 5.11 Supplying and fixing wall mounted light bracket/ fixture made with polycarbonate suitable for single 9/10 watt LED lamp directly on wall including connections etc as required. ( But without lamp ) Each 63 1340 84420
20 5.12 Supplying and fixing post top / garden light (width 200 mm) made up of high grade unbreakable polycarbonate material suitable for upto 7 watt LED lamp including connections and earthing the body etc as required. ( But without lamp) Design will be get approved from E/I before purcahse Each 9 1114 10026
21 5.13 Supplying and fixing post top / gate light (width 250/300 mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( But without lamp) Design will be get approved from E/I before purcahse Each 18 1399 25182
22 5.15 Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required.
23 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
a 6.1.4 9/10 watt LED lamp Each 161 11270
b 6.1.5 12 watt LED lamp Each 31 239 7409
c 6.1.7 20 watt LED lamp Each 40 267 10680
24 7.4 Laying and fixing of one number pVC insulated and pVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
a 7.4.1 Upto 35 sq. mm (CIamped with 1 mm thick saddte) mtr 100 43 4300
25 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
26 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. Each 65 2482 161330
27 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
a 8.17.1 300 mm sweep Each 10 2572 25720
28 8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required Each 20 3670 73400
29 8.2 Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy duty fan including fixing the bracket, making connection, testing, commissioning etc as required. Each 40 9941 397640
30 DSR 25 32.5 Supplying, Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 5.5 Mtr (IDU to ODU), i/c drain pipe of suitable length and size, outdorr stand. R-32/R-410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary with min 5 year Original Equipment Manufacturer (OEM) warranty
both compressor and Printed Circuit Board (PCB). as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.
a 32.5.5 3.3 TR BEE 5 Star Rating Each 8 104086 832688
31 DSR 25 32.2 Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original
Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
a 32.2.4 2.0 TR with 5 Star BEE Rating Each 2 57396 114792
b 32.2.3 1.5 TR with 5 Star BEE Rating Each 1 43539 43539
32 DSR 25 31.14 Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : Make- as per approval of EIC
a 31.14.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm mtr 50 256 12800
b 31.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm mtr 120 487 58440
c 31.14.4 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm mtr 615 104550
33 DSR 25 4.1 Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.
a 4.1.3 200 mm width X 50 mm depth X 1.6 mm thickness mtr 100 775 77500
b 4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness mtr 100 866 86600
34 MP SOR 46.2 + GST Dismantling &shifting, installation, testing & commissioning of split air conditioning unit 1.0TR/1.5TR/2TRcapacity including indoor / outdoor unit complete as required within town. Each 40 68676
35 MP SOR 46.5 + GST Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any.
a 46.5.3 + GST UPTO 2.0 TR Each 40 96382.4
36 MP SOR 31.16 + GST Supply, fixing & testing of approved make of LED integral type bollard cylindrical/square shape housing cast aluminium dome shape top cover fixed with cylindrical shape acrylic cover having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc. as required. LED of 1 to 3 Watt each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare, comprises of driver PF> 0.95 & surge protection 10KV. IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
a 31.16.1 + GST Bollard LED 8-10 Watt cylindrical shape height > 700mm, color temp 3000-6000k Each 40 217780.8
37 DSR 25 26.2 Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for
reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV
surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery:
Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature with battery stand. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc Make- Vertic, APC, Numeric or approved equivalent as per approval of EIC
a 26.2.2 20KVA (Each Power module shall be < 10 KVA) Each 1 341772 341772
38 Analysis Rate Dismentaling keeping safe and hand Over defective and conventional Light fand and other electrical & electronics fittings to department Job 1 23386 23386
Electrical works (Schedule Items) ( F ) Total 6189346.2
Total Schedule Amount (Rs.) ( E+F ) Total Total 22910669.883174147
(Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य
NON-SCHEDULED ITEMS
S. No. ITEM NO. DESCRIPTION OF ITEMS Unit Quantity Quoted Rate In Figure(Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Rate In Word (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Amount (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect)
Civil Work (Non-Schedule Items)
1 NS-1 P/F Accoustic wall panel as per requrement Sqm 280
2 NS-2 Providing and laying modular carpet apporoved make and shade Sqm 310
3 NS-3 Establishment of submersible pump set ( Discharge 240 LPM & total Head 53 m.) of approved brand and make- Crompton / KSB, all complete as per direction of E/I. Each 2
4 NS-4 Providing and Fixing Acoustical Wooden Stage Flooring Compatible with Underground signal cabling and Pop-Up Boxes: Providing and fixing 65/75 X 18 thick in random length, 2nd class teakwood planks flooring with tongue and groove joints on a layer of 19 mm thick BWR grade ply of approved make and manufacture, fixed to hardwood joint 50 X 50 mm at 600 mm c/c in one direction and 60 X 50 mm Sal battens 600mm c/c on other direction, Hardwood joint resiliently supported on 100 X 100 mm Rubber Pads, the framework to be filled with 50mm thick Insulation Wool resin bonded insulation of density 24kg/cum. PU polishing of teakwood on the exposed surface: In horizontal/vertical plane (rate for flooring shall include providing additional framework required for housing microphone and power outlet junction - signal & Popup Stage boxes, If required providing and fixing hinged 18mm thick teakwood cover for the junction boxes.Work complete in all Respect. The Work shall be executed as per drawings, Specifications & Instruction of engineer in charge Sqm 190
Electrical (Non-Schedule Items)
1 NS-1 SITC of Networked DSP processor - Digital Signal Processing with following Specification Dedicated 8 Input & 16 output , Expandable upto 128x128 network I/O channels, telephone POTS, General Purpose Input 16 output 16 , LAN Port x2, USB B type port ,RS232 or better. (Make: JBL /HARMAN GROUP /Yamaha /TW/QSC/D&B ) Nos 1
2 NS-2 SITC of Digital Mixer - Digital audio mixer with 30 inputs or more,14 Aux outputs , DAW USB port, network port ,Remote mixing with your iPad,inbuilt recording and playback function Should support on-board digital audio routing, etc. (Make: JBL /HARMAN GROUP /Yamaha /TW/QSC/D&B ) Nos 1
3 NS-3 SITC of Mini Stagebox 32i/16i Compact Digital Stageboxes with Remote Controlled I/O Stagebox 32i and 16i combine high-quality components with a streamlined design, making it easy to add multiple channels of remote-controlled I/O to your Si-series mixing console. The Studer-designed mic preamps provide exceptional sound quality, while the compact form factor offers easy transport and fast configuration. Ideal for live engineers, houses of worship, bands, club owners and corporate installations, Soundcraft Mini Stageboxes allow you to replace heavy, expensive analog snakes with a single RJ45 Cat5 style Ethernet cable. (Make: JBL /HARMAN GROUP /Yamaha /TW/QSC/D&B ) Nos 1
4 NS-4 Supply of Bluetooth Audio Reciver The AIR LINK DW 20BR Bluetooth Wireless Stereo Receiver brings the convenience of high-performance audio-streaming to any installed or portable sound system. Specification Outputs Connectors - Balanced XLR, unbalanced ¼" /Impedance - 240 Ω /Max. output level - 4 dBu @ 1 kHz /Bluetooth -Frequency range :-2402 - 2480 MHz / Receiver range - Up to 30 m (100 ft) System Frequency response -20 Hz to 20 kHz (+0/-2 dB) / Signal-to-noise ratio >90 dB /Power adaptor -12 V DC, 400 mA,center positive Make :- Klark Teknik / OEM Each 1
5 NS-5 SITC of cardioid electret condenser microphone with 450mm Lenght or better A filter in the microphone grille shall suppress wind and pop noise. A programmable button shall operate in the operating modes ON/OFF, Push-To-Talk and Push-To-Mute. The microphone button shall be disabled when needed. The frequency response shall be selectable in two stages: linear or with low-cut filter to suppress lowfrequency noise. The LED ring to display the microphone status shall be deactivated when needed. The LED ring integrated in the microphone head shall illuminate red to display the ready-to-speak status of the microphone. The microphone shall have an excellent RFI shielding and is immune to wireless communication devices. The microphone shall operate with phantom power P12, P24 or P48. A preamp with electronically balanced signal output shall be integrated in the base. The gooseneck shall have two flexible 6 mm [0.24"] or better thin elements with a rigid tube in between. The housing shall be black, free from reflections and completely made of metal. The frequency response shall be 50 to 19,000 Hz. The open circuit voltage shall be 17 mV/Pa. The nominal impedance shall be 200 ohms. Each 12
6 NS-6 Supply installation testing & commissioning of Wired Vocal Microphone , Transducer type Dynamic Polar pattern Super cardioid Frequency response: 30 - 18,000 Hz Nominal impedance 600 Ω Connection 3-pin XLR male (Approved Make: Beyerdynamic/Shure/ Sennheiser)/ Equivalent Nos 0
7 NS-7 Supply installation testing & commissioning of Instrument Microphone with high-frequency reproduction ; Polar Pattern: Cardioid, Frequency response : 50-17,000 Hz ; Open circuit voltage : 2.4 mV/Pa, Nominal impedance : 600 Ω, Load impedance : ≥ 2 kΩ, Connection : 3-pin XLR tc. complete with installation as per the site requirement.(Approved Make: Televic/Shure/ Sennheiser) Nos 0
8 NS-8 Supply installation testing & commissioning of Handheld wireless microphone : Wirless Handheld UHF true diversity wireless system, cpl. with NE 600 S and SDM 669, PLL, pilot tone, ACT/SCAN-function, 16 preprogrammed frequencies, incl. softcase, batteries, rack mount brackets, MKV 11 and switching power supply(Approved Make: Televic/Shure/ Sennheiser) Nos 2
9 NS-9 Supply installation testing & commissioning of Lapel microphone : Wireless Lapel UHF true diversity wireless system, cpl. with NE 600 S, TS 601 and TG L55c lavalier microphone, PLL, pilot tone, ACT/SCAN-function, 16 pre-programmed frequencies, incl. softcase, batteries, rack mount brackets and switching power supply (Approved Make: Televic/Shure/ Sennheiser) Nos 1
10 NS-10 Supply installation testing & commissioning of Floor Boxes : Container for electrical connections, usually intended to conceal them from sight and deter tampering. Make - OEM Nos 6
11 NS-11 Supply installation testing & commissioning of Microphone stand (big) : Long Stands for microphone Make- OEM Nos 8
12 NS-12 Supply installation testing & commissioning of Microphone stand (short) : Short Stands for microphone ( Make - Falcom / MX / Kristal OEM ) Nos 6
13 NS-13 Supply installation testing & commissioning of Microphone Cable : Cable with thickness of 2 Core shielded cable Make - ( Falcom / B elden / Kristal ) Mtr 400
14 NS-14 Supply installation testing & commissioning of Microphone Cable : Cable with thickness of 4 pair 8 Core shielded cable Make - ( Falcom / B elden / Kristal ) Mtr 600
15 NS-15 Supply installation testing & commissioning of Speaker Cable : Cable with thickness of 2 Core 2.5 Sqmm Make - ( Falcom / B elden / Kristal ) Mtr 50
16 NS-16 Supply installation testing & commissioning of UL Listed All Type of connectors Like - Rj45,xlr,3.5JACK etc as site requried For inter connection of equipments.Make- OEM , Dlink , Nutrick, MX Lot 1
17 NS-17 SITC of Transmitter and Receiver with scaler 4k capable with HDMI Input and Twisted Pair Output - HDMI Tx & Rx extension module supporting 4K/UHD capability @ 60 Hz with 4:2:0 chroma subsampling Control over one CATx cable for upto 70m HDCP , EDID compliant Input Port: Tx - 1 x HDMI, Rx - 1 x HDBaseT Output Port: Tx - 1 x HDBaseT, Rx - 1 x HDMI 4K/UHD capability @ 60 Hz with 4:2:0 chroma subsampling HDBaseT compatible HDMI, HDCP, CEC, EDID compliant Distance upto 70m PoE Compatible Support RS-232, IR, and CEC control signals over HDBaseT. (Approved Make: Milestone / Linetek/ WyreStrom) Nos 1
18 NS-18 Supply installation testing & commissioning of Class D 4 Zone power amplifier Channels:- 2 ,Sensitivity -1.4V Rated Power Output (per channel)3000W 2Ω, 2100W 4Ω, 1200W 8Ω ,Signal to Noise Ratio (below rated 1 kHz power at 8 ohms) 103 dB (A-weighted) THD< 0.5% Frequency Response (at 1W, 20 Hz - 20 kHz)+ 0 dB, -1 dB Crosstalk (below rated power) 20 Hz to 1 kHz>70 dB Frequency Response 60 Hz~15 KHz ( ± 3 dB ) or better ; THD <0.5 % at 1 KHz, 1/3 rated power or better ; S/N >80dB or better ; Controls Volume control and power switch or better (Approved Make: JBL /RCF /HARMAN GROUP/TW/QSC/Yamaha ) Nos 2
19 NS-19 Supply installation testing & commissioning of Intractive Podium – unmatched interaction with various digital devices. Its ergonomic design allows you to collaborate with your partners, customers, and business associates with technological ease. Its modular form factor provides great productivity benefits, enabling easy mobility of the device. Body : Metallic ,Keyboard Slider : Available ,Document Camera Tray : Available ,Top Sliding: Available ,Electronic Monitor Lift : Available, Touch Monitor : Available ,Monitor Size : 21.5 inch , Gooseneck Mic : Optional Cooling Fans : Available CPU : Optional* Make - Peolelink / Bench Mark /MAXHUB nos 1
Total Schedule Amount (Rs.) Total
INFRASTRUCTURE DEVELOPMENT AUTHORITY
(A GOVERNMENT OF BIHAR UNDERTAKING)
(Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य
QUOTING SHEET FOR BIDDERS
Name of Contractor
Address of Contractor
E-mail ID of Contractor Whatsapp Enabled Mobile Number
NIT - 16/TEN/IDA/26
Sl no. Description Estimated Amount Rate Quoted by Contractor
% Above/Below TOTAL QUOTED AMOUNT Rs.(In Figure) TOTAL QUOTED AMOUNT Rs.(In Words)
1 Total Schedule Amount (Rs.) 22910669.883174147
2 Total Non-Schedule Amount (Rs.) To be Quoted!
TOTAL AMOUNT Rs. 33115805
(Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य
S.No. Particular Amount
1 Schedule Items 22910669.883174147
2 Non-Schedule Items
(Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य
SCHEDULED ITEMS
S.No. BCD SOR-22 DESCRIPTION OF ITEMS Unit Quantity Rate Amount
Civil Work (Schedule Items)
1 2.8.1 Earthwork in excavation in foundation trenches or drains(not exceeding 1.5m in width or 10 sqm on plan)including dressing of sides and ramming of bottom lift upto 1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m All kinds of soil. Cum. 250 360.75 90187.5
2.26 Filling available excavated earth(including rock)in trenches ,plinth,sides of foundation etc.in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead. Cum. 25 123.9 3097.5
2.28 Supplying and Filling in plinth with local sand and under floors including watering ,ramming consolidating and dressing complete. Cum. 80 287.3 22984
4 15.2 Demolishingcementconcreteincludingdisposalofmaterialwithin 50 metre lead:
S.H. III: MASONRY WORK
5 6.1A Brick work with bricks of class designation 100A in foundation and plinth in:
6.1.12/1 cement mortar 1:4 (1 cement : 4 coarse sand) cum 25 5017.9 125447.49999999999
6 6.3A Extra for Brick work in superstructure above plinth level upto floor V level cum 840.25 21006.25
7 6.21A Extra for providing and placing in position 2Nos. 6mm dia. MS bars at every third course of half brick masonry (with F.P.S. brick) sqm. 113.6 2840
SH-IV: CONCRETE WORK
8 5.37 Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended roportions as per IS : 9103 to accelerate/retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer - in - charge. M-25 grade Reinforced cement concrete by using 330 kg of cement per cum of concrete.
A 5.37.1 All works up to Plinth level cum 20 5562.4 111248
B 5.37.2 All works above Plinth level up to floor five level. cum 12 6372 76464
9 5.34 Add or deduct for providing richer or leaner mixes respectively at all floor levels.
10 5.9 Centering and shuttering including strutting,propping etc and removal of form for:
A 5.9.1 Foundation,footing,Bases of column etc for mass concrete. sqm 12 211.6 2539.2
B 5.9.3 suspended floors sqm 20 437.5 8750
C 5.9.5 Lintels,Beams,Plinth beams,girders,bressumers and cantilevers. sqm 24 404.7 9712.8
D 5.9.6 Columns,Pillars,Piers,Abutments,Posts and struts. sqm 25 494.4 12360
SH-V: STEEL WORK
5.22 Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding complete.
A 5.22.7A Thermo-Mechanically Treated barsTMTC-500-8mm dia Kg. 1200 94.5 113400
B 5.22.7B Thermo-Mechanically Treated barsTMTC-500-10mm dia Kg. 2500 92.6 231500
C 5.22.7C Thermo-Mechanically Treated barsTMTC-500-12mm dia Kg. 3000 90.8 272400
S.H. VI : WOOD & ALUMINIUM WORK
12 9.1 Providing wood work in frames of doors, windows, clerestroy windows and other frames, wrought framed and fixed in position:
9.1.1 Second class teak wood cum 5.5 120526.6 662896.3
9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
9.21.1 35 mm thick including ISI marked stainless steel butt hinges with necessary screws sqm 30 1775.3 53259
14 9.74 Providing and fixing bright finished brass tower bolt (barrel type) with necessary screws etc. complete.
9.103 Providing and fixing bright finished brass 100mm mortice latch and lockwith 6 lever handles with necessary screws etc. complete (best make of approved quality) Each 15 655.4 9831
9.81 Providing and fixing bright finished brass handle with necessary screws etc. complete.
9.82 Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. complete. Each 21 108.1 2270.1
9.88 Providing and fixing chromium plated brass 100 mm latch and lock with 6 levers and a pair of handles of approved quality with necessary screws etc. complete Each 6 733.1 4398.6
9.84 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564,embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete Each 21 810.1 17012.100000000002
20 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubula sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 450 418.4 188280
21 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
21.3.2 With float glass panes of 5.50 mm thickness(weight not less than 12.50 kg/sqm Sqm 300 1115.1 334530
22 9.127 Providing&Fixing decorative high pressure laminated sheet of plain/wood graining loss/matt /suede finish with high density protectivesurface layer and reverse side of adhesive bonding quality conforming to IS:2046 Type S, including cost of adhesive of approved quality.
S.H. VII : FLOORING WORK
23 11.72 Providing desination 100 A one brick flat soling joints filled with local sand including cost of watering texes, roualty all complete as per building specification and direction of E/l. sqm 150 283.3 42495
24 8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing etc. complete at all levels.
8.2.2 Granite of any colour and shade
8.2.2.2 Area of slab over 0.50 sqm sqm 50 4401.2 220060
8.3 Extra for providing edge moulding to 19 mm thick marble stone counters, Vanities etc. over item no. 8.2 mm thick marble stone counters, Vanities etc. over item no. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Granite work
26 11.41A Providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorptions less than0.08% and conforming to IS : 15622 of approved brand & manufacturer in all colours and shades, laid on 20mm thick cement motar 1:4 (1cement : 4 coarse sand) jointing with grey cement slurry @3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.
A 11.41A.2 Glazed Vitrified floor tile polished finish of size
B 11.41A.3 Glazed Vitrified tile Matt/ Antiskid finish of size
11.41A.3.1 Size of Tile 600 x 600 mm (for floor toilet) sqm 150.72 1054.3 158904.096
27 7.23 Stone work (machine cut edge) forwall lining etc. (veneer work) over 12 mm thick be dofcement lime mortar1:1:6 (1cement:1 lime putty: 6 fine sand ) including pointing in white cement mortar 1:2(1whitecement: 2 stonedust) with an admixture of pigment matching the stone shade: (To be secured to the backing bymeans of cramps which shall be paid for seperately)
A 7.23.1 Red sand stone- exposed face fine dressed with rough backing
B 7.23.2 White sand stone
28 14.72 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Sqm. 2500 178.3 445750
29 25.3 Cleaning the sand stone surface and removing dirt, dust, bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agent as approved by chaeological Survey of India/ Engineer-incharge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building/ structure, all as per direction of Engineer-in-charge (The rate is inclusive of all materials & labours involved except scaffolding). sqm 1500 75.3 112950
30 25.4 Providing and applying antifungal wash treatment using 3% solution of sodium pentachlorophenate, of reputed brand and manufacturer,on cleaned sand stone surface at desired locations as per direction of Engineer-in-charge (The rate is inclusive of all materials & labours involved except scaffolding). sqm 1500 29.8 44700
31 7.25 Providing and fixing gunmetal cramps of required shape for anchoring stonewall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2(1cement: 2finesand) including making the necessary chases.
32 13.11 Cement plaster in course sand 12mm cement plaster of mix :
13.11.4 1:6 (1Cement : 6 Coarse sand) Sqm. 1200 141.5 169800
13.13 20mm cement plaster of mix :
13.13.4 1:6 (1 cement : 6 coarse sand) sqm 1500 192.1 288150
S.H. IX : FINISHING WORK 0
34 13.74 Removing white or colour wash by scraping and sand papering and preparing the surface smooth including necessary repair scratches etc. complete sqm 3000 7.7 23100
35 13.93 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.93.1 Two or more coats on new work Sqm 1500 84.5 126750
13.80 A.1 Providing and applying white cement based putty of average thickness 1mm, of approved brand andmanufacturer, over the plasteredwall surface to prepare the surface even and smooth complete. Sqm 3000 81.1 243299.99999999997
13.92 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.
13.92.1 Two or more coat on new surface. Sqm 3000 86.4 259200.00000000003
38 13.116A Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this drybsurface is again fine wet rubbed smooth, which is further allowedto dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time Sqm 900 786.9 708210
39 2.37. DilutingandinjectingchemicalemulsionforPOSTCONSTRUCTIONAL anti-termites' treatrnent(including the cost of chemical emulsion)
2.37.5 Treatment at points of contact ot wood work by chemical emulsion chlordane. (in oil or kerosene based solution)® 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. metre 600 270.2 162120
SH-X: FALSE CEILING WORK
40 12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made up of special sections power pressed from M.S. sheet and galvanized in accordance with zinc coating of 120 gms/sqm as per IS:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts to the angle hanger of 25x25x5 mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connection clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of
20 mm and 30 mm long, the perimeter of ceiling fixed to wall/ partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long drive-all screws @230 mm interval including jointing and fixing to a flush finish of tapered and square edges of the gypsum board with recommended filler, paper tapes, finishers and two coats of primer suitable for gypsum board as per manufacturers specification and also including the coat of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per the drawing and specification and direction of the the Engineer-in-charge but excluding the cost of painting.
12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board Sqm 600 993 595800
41 12.62 Extra for any sunk or raised moulding in the plaster of paris (Gypsum anhydrous ) ceilng .All complete as per specification and direction of E/I. Sqm 283 169800
42 26.27 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture,design and pattern. The tiles should have Humidity Resistance (RH) of 99%,Light Reflectance≥85%,Thermal Conductivity k=0.057 w/m K,Fire Performance as per (BS 476 pt-6 & 7)in true horizontal level suspended on interlocking T- Grid of hot dipped all round galvanised iron section of 0.33mm thick(galvanized @120gsm)comprising of main T runners of 15x32mm of length 3000mm,cross T of size15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item(galvanised @80gsm) 50mm long 8mm outer diameter M-6 dash fasteners,6mm diameter fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm,spaced at 1200mm centre to centre along main 'T'. The system should rest on periphery walls/partitions with the help of GI perimeter wall angle of size 24x24x3000mm made of 0.40 mm thick sheet, to be fixed to the wall with the help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint,for all heights. The work shall be carried out as per specifications,drawings and as per directions of the engineer-in-charge.
26.27.2 With 20mm thick beveled tegular mineral fibre false ceiling tile (NRC0.7). Sqm. 477.36 2120.7 1012337.352
43 12.54X Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join,C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with
12.54X.1 GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (m nimum), including factory painted after bending. sqm 450 1626.3 731835
SH-XI: WATERPROOFING WORK
44 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C kitchen and thelike consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions. (ii) IInd course of 20mm cement plaster 1:3 (iii) litrd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area. (iv) lvth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC shet should be 100mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). sqm 351.5 480.6 168930.9
22.2 Providing and fixing APP (Atactic Polypropylene Polymer ) modifieid prefabricated five layer 3mm thick water proofing membrane,black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sq. mtr. by the same membrane manufacture of density at 25degree centigrate,0.87 -0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc. and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be : joint strength in longitudinal and transvers direction at 23 degree centigrate as 650 / 450 N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150degree . Cold flexibility shall be upto -2 degree centigrate when tested in accordance with ASTM, D-5147 . The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
46 22.21 Extra for covering top of membrane with Geotexitle , 120 gsm non woven, 100 5% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heatiig the membrane by Butane torch as per manufactures recommendation. sqm 85.2 255600
47 12.38 Providing gola 75 x 75mm in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement: 3 fine sand) as per standerd design:
12.38.1 In 75x75mm deep chase sqm 66 198000
48 12.39 Making khurras 45 x 45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20mm nominal size) overP.V.C sheet 1mx 1m x 400 micron, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement rounding the edes and making and finishing the outlet complete. Each 190 189.4 35986
49 12.52 Grading roof for water proofing treatment with
12.52.2 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate cum 300 3932.2 1179660
50 15.41 Dismantling cement asbestos,Celotaxorotherhardboardceiling or partitionwalls includingstackingof serviceablematerialsand disposal of unserviceable materials within 50 metres lead sqm 23.7 71100
51 CARRIAGE OF MATERIAL
A Coarse sand ( lead of 2K+55 P from Koilwar ) Cum. 200 1550.08 310016
B Local Sand ( Lead local 1K+2P) Cum. 120 310.469152 37256.298240000004
C Stone chips ( lead By Rail from Manpur) Cum. 300 1427.28 428184
D Red Bricks 100A(local lead 1K+7P) Per 1000 1200 1140.59 1368.708
E Cement 5 km P MT 518.09 62.1708
52 EXTRA FOR MATERIALS
A Add for Cement (PSC) MT 120 265.41 31849.200000000004
B Add for Bricks Per 1000 1606.89 1928.2680000000003
TOTAL FOR CIVIL WORK=A 13581916.483040001
SECTION -2 PLUMBING WORKS
S.H. - I : Sanitary Fixture & CP Fittings
53 17.1 Providing and fixing water closet squatting pan (Indian Type W.C. Pan) with 100mm sand cast iron P or S trap. 10 litre low fixtures complete , including cutting and making good the walls and level white P.V.C flushing cistern, including flush pipe, with manually controlled device (handle lever) confirming to IS 7231, with all fittings and floors wherever required.
17.1.1 White vitreous china Orissa pattern W.C pan of size580 X 440 mm with integral type foot rests. Each 16 4470.9 71534.4
17.3 Providing and fixing white vitreous china pedestal type water coset (Europenan type) with seat and lid , 10 litre low level white vitreous china flusing cistern & C.P flush bend with fittings & C.I.brackets , 40 mm flush bend, overflow arrangment with specials of standard make and mosquito proof coupling of approved municiple desine complete, including painting of fittings and brackets ,cutting and making good the wall and floiirs wherever required.
17.3.1 W.C pan with ISI marked white solid plastic seat and lid Each 8 5504.3 44034.4
17.4 Providing and fixing .white vitreous china flat back or wall corner type lipped front urinal basin of size 450 x 260 x 350mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and CP brass spreaders with brass unions and GI clamps complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required.
17.4.2 Range of two urinal basin with 5 litre white P.V.C. automatic flushing cistern. Each 8 5733.3 45866.4
17.7 Provding and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, , 32 mm C.P. brass waste of standard pattern, including paintings of fittings and brackets, cutting and making good the .wall wherever required.
17.7.4 White vitreous china flat back wash basin size 550X400mm with a single15mm CP brass pillar tap Each 32 2135.8 68345.6
17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required :
17.9.1 White glazed fire clay kitchen sink of size 600x450x250 mm Each 4 2778 11112
17.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever as required. :
17.10.1 Kitchen sink with drain board
17.10.1.1 510x1040 mm bowl depth 250 mm Each 1 5231.5 5231.5
17.31 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete. Each 32 1068.5 34192
17.33 Provding and fixing 600X120X5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with CP brass brackets and guard rail complete fixed with 40 mm long screws ,rawl plug etc, complete. Each 32 713.3 22825.6
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
17.28.2 Flexible pipe
17.34 Providing and fixing toilet paper holder.
17.7 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
A 17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. Each 32 325.1 10403.2
B 17.70.2 Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. Each 20 325.1 6502
17.71 Proving and fixing PTMT liquid soap container 109mm wid, 125mm high and 112 mm distancefrom wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour , weighting not less than 105 gms. Each 16 146.3 2340.8
17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. Each 16 204.7 3275.2
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. Each 16 424 6784
8.1 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and 0
8.10.2 Granite stone of approved shade Sqm 16 3542.9 56686.4
18.21 Providing and fixing PVC Unplasticised Connection pipe with brass ions :
18.21.2 45 cm length
18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931 0
18.49.1 15 mm nominal bore Each 24 434.2 10420.8
18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS :8931
18.51.1 15 mm nominal bore Each 16 708.4 11334.4
18.52 Providing and fixing C.P. brass stop cock (concealed) of approved standard design and of approved make conforming to IS:8931 0
18.52.1 15 mm nominal bore Each 16 594.8 9516.8
18.53 Providing and fixing C.P. brass angle valve of approved quality conforming to IS :8931 0
18.58 Providing and fixing PTMT grating of approved quality and colour. 0
18.58.1 Rectangular type with openable circular lid
18.58.2.1 150 mm nominal size square 100mm diameter of the inner hinged round grating Each 16 169.7 2715.2
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. Each 16 299.4 4790.4
TOTAL FOR SANITARY FIXTURE & C.P FITTINGS =B 484012.30000000005
S.H. - II : WATER SUPPLY & RAIN WATER PIPE
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
A 18.7.2 20 mm dia. Nominal outer dia pipes Mtr. 30 233.9 7017
B 18.7.3 25 mm dia. Nominal outer dia pipes Mtr. 45 317.3 14278.5
C 18.7.4 32 mm dia. Nominal outer dia pipes Mtr. 40 395.2 15808
D 18.7.5 40 mm dia. Nominal outer dia pipes Mtr. 70 538.4 37688
E 18.7.6 50 mm dia. Nominal outer dia pipes Mtr. 75 791 59325
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.
Concealed work including cutting chases and making good the walls etc.
A 18.8.1 15mm nominal outer dia pipes Mtr. 90 278.2 25038
B 18.8.2 20mm nominal outer dia pipes Mtr. 70 350.8 24556
C 18.8.3 25mm nominal outer dia pipes Mtr. 95 463.1 43994.5
18.9 Providing and fixing Chlorinated polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, This includes jointing of pipes & fittings with one step CPVC solvent cement trenching,refilling and testing of joints complete as per direction of engineer in charge.
18.9.5 40 mm dia. Nominal outer dia pipes Mtr. 45 477.6 21492
18.13 Making connecting of G.I. distribution branch with G.I. Main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.
18.13.1 25 to 40 mm Nominal bore Mtr. 40 446.7 17868
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
A 18.17.1A 20 mm nominal bore Each 10 465.4 4654
B 18.17.1 25 mm nominal bore Each 10 532.3 5323
C 18.17.2 32 mm nominal bore Each 2 589.9 1179.8
D 18.17.3 40 mm nominal bore. Each 2 707.3 1414.6
E 18.17.4 50 mm nominal bore. Each 2 878.2 1756.4
18.19 Providing and fixing metal non-return valve of approved quality.
18.19.3 40 mm nominal bore
A 18.19.3.1 Horizontal Each 1 815 815
B 18.19.3.2 Vertical Each 1 1049.2 1049.2
18.46 Providing and fixing G.I. union in G.I.pipe including cutting and threading the pipe and making long screws etc.complete
A 18.46.2 20 mm dia. Nominal bore Each 12 185.6 2227.2
B 18.46.3 25 mm dia. Nominal bore Each 14 265.9 3722.5999999999995
C 18.46.4 32mm dia. Nominal bore Each 4 306 1224
D 18.46.5 40mm dia. Nominal bore Each 8 419.7 3357.6
E 18.46.6 50mm dia. Nominal bore Each 6 565.6 3393.6000000000004
12.78 Providing and fixing on wall face unplasticised-PVC (working pressure 4 Kgf per sqm) rain water pipes conforming to IS:4985including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion
12.78.2 110mm diameter Mtr. 292 257.5 75190
12.79 Providing and fixing on wall face unplasticised -PVC moulded fittings/ accessories for unplasticised PVC rainwater pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
12.79.1 Coupler
B 12.79.5.2 110mm bend Each 132 5544
12.79.6 Shoe (Plain)
12.8 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S screws of required length including cutting brick work and fixing in cement mortar 1:4( 1 cement: 4 coarse sand) and making good the wall etc. complete.
12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 14 47.9 670.6
TOTAL FOR WATER SUPPLY & RAIN WATER PIPE =C 443425.8999999999
S.H. III : DRAINAGE SYSTEM
2.1 Excavating trenches of required width for pipes, cables etc including excavation for sockets and dressing of sides, ramming of bottoms depth upto 1.5m ,including getting out the excavated soil , and then returning the soil as required,in the layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering and desposing of surplus excavated soil as dirceted within a lead of 50m
2.10.1.2 pipes cables etc exceeding 80mm dia but not exceeding 300 mm dia Mtr. 400 391.7 156680
19.6 Providing and laying non -pressure NP2 class(light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joints etc. complete
B 19.6.4 300 mm dia. R.C.C. pipe Mtr. 200 780 156000
19.7 Constructing brick masonary manhole in cement mortar 1:4 (1 cement, 4 coarse sand.) R.C.C. top slab with1:2:4 mix(1 cement, 2 coars e sand, 4 graded stone aggregate 20 mm nominal size) foundation cocrete 1:4:8 mix (1cement, 4 coarse sand, 8 graded stone aggregate 40 mm nominal size.) inside plastering 12 mm thick with cement mortar 1:3 (1 cement, 3 coarse sand.) finished with floating coat of neat cement and making channels in cement concrete 1:2:4. finished with floating coat of neat cement complete as per standard design.
19.7.1 Inside size 90x80cm and 45 cm deep including C.I. cover with frame ( light duty) 455x610 mm internal diamension tatal weight of cover and fram to be not less than 38 kg (weight of cover23 kg and weight of frame 15 kg )
19.7.1.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 45 7914.7 356161.5
88 24.1 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
24.1.1 All types of soil
89 24.2 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre and upto 150 metre depth below ground level.
24.2.1 All types of soil
90 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
24.3.1 100 mm nominal size dia Mtr. 90 546.1 49149
24.3.2 150 mm nominal size dia Mtr. 60 660.1 39606
91 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
24.4.1 100 mm nominal size dia Mtr. 60 573.1 34386
92 24.8 Gravels packing in tubewell construction in accordance with IS 4097 including providing graval fine/medium/coarse,in required grading & sizes as per actual requirement,all complete as per direction of Engineer-in charge. cum 14.16 1343.2 19019.712
93 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hrs 96 916.8 88012.79999999999
24.13 Providing & fixing suitable size threaded mild steel cap or spot welded plate to the top of borewell housing/ casing pipe ,removable as per requirement,all complete for borewell of,
94 24,14 Providing & fixing MS clamp of required dia to the top of housing/casing pipe of,removable as pe tubewell as per IS;2800(part-I), including necessary bolts & nuts of required size complete
95 24.15 Providing & fixing Bail plug/ bottom plug of required dia to the bottom of pipe assembly as per IS;2800(part-I),
TOTAL FOR DRAINAGE WORK =D 1361301.8120000002
TOTAL FOR PLUMBING WORK =(B+C+D) 2288740.012
Total civil work (E) Total 16721323.683174148
Electrical (Schedule Items)
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required.
a 1.3.3 Group C Each 150 1146 171900
2 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. Mtr 250 309 77250
3 1.6 Wiring for light/ power plug with 4 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in sufface / recessed medium class PVC conduit along with 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. Mtr 450 523 235350
4 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a 1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Mtr 150 201 30150
b 1.7.2 2 X 2.5 sq. mm + 1X 2.5 sq. mm earth wire Mtr 150 246 36900
5 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ reeessed PVC conduit as required.
6 1.24 Supplying and fixing following modula'r switch/ socket on the existing modular plate & switch box including connections but excluding modular plate.etc. as required.
a 1.24.1 5/6 amps switch Each 50 82 4100
b 1.24.3 15/16 amps switch Each 25 139 3475
c 1.24.4 3 pin , 5/6 amps socket outlet Each 50 112 5600
d 1.24.5 6 pin, 15/16 amps socket outlet Each 25 183 4575
7 1.27 Supplying and fixing following size/ modules, Gl box along with modular base and cover plate for modular switches in recess etc as required.
a 1.27.2 3 Module (100mm X 75mm) Each 25 266 6650
8 2.33 Supplying and fixing , following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as lncomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBS)
a 2.33.4 12 way, Double door, l/C 1604, MCCB Each 1 20409 20409
9 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required'
a 2.4.1 100 A , 30 KA, FPMCCB Each 1 8172 8172
10 2.12 Supptying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete w
a 2.12.1 6 A to 32'A, Single pole Each 25 237 5925
11 2.25 Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Each 8 3008 24064
12 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required. set 2 16675 33350
13 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. mtr 100 144 14400
14 5.15 Supplying and fixing fotrlowing types LED Flood / Track light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required.
15 5.1 Supplying and fixing 4' X 18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required. Each 148 521 77108
16 5.2 Supplying and fixing 2' X 9 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. Each 65 492 31980
17 5.8 Supplying and fixing surface / recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
18 5.9 Supplying and fixing recess / surface mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. Each 443 2663 1179709
19 5.11 Supplying and fixing wall mounted light bracket/ fixture made with polycarbonate suitable for single 9/10 watt LED lamp directly on wall including connections etc as required. ( But without lamp ) Each 63 1340 84420
20 5.12 Supplying and fixing post top / garden light (width 200 mm) made up of high grade unbreakable polycarbonate material suitable for upto 7 watt LED lamp including connections and earthing the body etc as required. ( But without lamp) Design will be get approved from E/I before purcahse Each 9 1114 10026
21 5.13 Supplying and fixing post top / gate light (width 250/300 mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( But without lamp) Design will be get approved from E/I before purcahse Each 18 1399 25182
22 5.15 Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required.
23 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
a 6.1.4 9/10 watt LED lamp Each 161 11270
b 6.1.5 12 watt LED lamp Each 31 239 7409
c 6.1.7 20 watt LED lamp Each 40 267 10680
24 7.4 Laying and fixing of one number pVC insulated and pVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
a 7.4.1 Upto 35 sq. mm (CIamped with 1 mm thick saddte) mtr 100 43 4300
25 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
26 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. Each 65 2482 161330
27 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
a 8.17.1 300 mm sweep Each 10 2572 25720
28 8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required Each 20 3670 73400
29 8.2 Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy duty fan including fixing the bracket, making connection, testing, commissioning etc as required. Each 40 9941 397640
30 DSR 25 32.5 Supplying, Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 5.5 Mtr (IDU to ODU), i/c drain pipe of suitable length and size, outdorr stand. R-32/R-410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary with min 5 year Original Equipment Manufacturer (OEM) warranty
both compressor and Printed Circuit Board (PCB). as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.
a 32.5.5 3.3 TR BEE 5 Star Rating Each 8 104086 832688
31 DSR 25 32.2 Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original
Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
a 32.2.4 2.0 TR with 5 Star BEE Rating Each 2 57396 114792
b 32.2.3 1.5 TR with 5 Star BEE Rating Each 1 43539 43539
32 DSR 25 31.14 Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : Make- as per approval of EIC
a 31.14.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm mtr 50 256 12800
b 31.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm mtr 120 487 58440
c 31.14.4 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm mtr 615 104550
33 DSR 25 4.1 Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.
a 4.1.3 200 mm width X 50 mm depth X 1.6 mm thickness mtr 100 775 77500
b 4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness mtr 100 866 86600
34 MP SOR 46.2 + GST Dismantling &shifting, installation, testing & commissioning of split air conditioning unit 1.0TR/1.5TR/2TRcapacity including indoor / outdoor unit complete as required within town. Each 40 68676
35 MP SOR 46.5 + GST Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any.
a 46.5.3 + GST UPTO 2.0 TR Each 40 96382.4
36 MP SOR 31.16 + GST Supply, fixing & testing of approved make of LED integral type bollard cylindrical/square shape housing cast aluminium dome shape top cover fixed with cylindrical shape acrylic cover having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc. as required. LED of 1 to 3 Watt each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare, comprises of driver PF> 0.95 & surge protection 10KV. IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
a 31.16.1 + GST Bollard LED 8-10 Watt cylindrical shape height > 700mm, color temp 3000-6000k Each 40 217780.8
37 DSR 25 26.2 Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for
reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV
surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery:
Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature with battery stand. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc Make- Vertic, APC, Numeric or approved equivalent as per approval of EIC
a 26.2.2 20KVA (Each Power module shall be < 10 KVA) Each 1 341772 341772
38 Analysis Rate Dismentaling keeping safe and hand Over defective and conventional Light fand and other electrical & electronics fittings to department Job 1 23386 23386
Electrical works (Schedule Items) ( F ) Total 6189346.2
Total Schedule Amount (Rs.) ( E+F ) Total Total 22910669.883174147
(Re-Tender) बामेती परिसर में अवस्थित प्रशासनिक भवन एवं छात्रावास की मरम्मति, विधुत कार्य, रंग -रोगण एवं ड्रेनेज सिस्टम का कार्य
NON-SCHEDULED ITEMS
S. No. ITEM NO. DESCRIPTION OF ITEMS Unit Quantity Quoted Rate In Figure(Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Rate In Word (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Amount (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect)
Civil Work (Non-Schedule Items)
1 NS-1 P/F Accoustic wall panel as per requrement Sqm 280
2 NS-2 Providing and laying modular carpet apporoved make and shade Sqm 310
3 NS-3 Establishment of submersible pump set ( Discharge 240 LPM & total Head 53 m.) of approved brand and make- Crompton / KSB, all complete as per direction of E/I. Each 2
4 NS-4 Providing and Fixing Acoustical Wooden Stage Flooring Compatible with Underground signal cabling and Pop-Up Boxes: Providing and fixing 65/75 X 18 thick in random length, 2nd class teakwood planks flooring with tongue and groove joints on a layer of 19 mm thick BWR grade ply of approved make and manufacture, fixed to hardwood joint 50 X 50 mm at 600 mm c/c in one direction and 60 X 50 mm Sal battens 600mm c/c on other direction, Hardwood joint resiliently supported on 100 X 100 mm Rubber Pads, the framework to be filled with 50mm thick Insulation Wool resin bonded insulation of density 24kg/cum. PU polishing of teakwood on the exposed surface: In horizontal/vertical plane (rate for flooring shall include providing additional framework required for housing microphone and power outlet junction - signal & Popup Stage boxes, If required providing and fixing hinged 18mm thick teakwood cover for the junction boxes.Work complete in all Respect. The Work shall be executed as per drawings, Specifications & Instruction of engineer in charge Sqm 190
Electrical (Non-Schedule Items)
1 NS-1 SITC of Networked DSP processor - Digital Signal Processing with following Specification Dedicated 8 Input & 16 output , Expandable upto 128x128 network I/O channels, telephone POTS, General Purpose Input 16 output 16 , LAN Port x2, USB B type port ,RS232 or better. (Make: JBL /HARMAN GROUP /Yamaha /TW/QSC/D&B ) Nos 1
2 NS-2 SITC of Digital Mixer - Digital audio mixer with 30 inputs or more,14 Aux outputs , DAW USB port, network port ,Remote mixing with your iPad,inbuilt recording and playback function Should support on-board digital audio routing, etc. (Make: JBL /HARMAN GROUP /Yamaha /TW/QSC/D&B ) Nos 1
3 NS-3 SITC of Mini Stagebox 32i/16i Compact Digital Stageboxes with Remote Controlled I/O Stagebox 32i and 16i combine high-quality components with a streamlined design, making it easy to add multiple channels of remote-controlled I/O to your Si-series mixing console. The Studer-designed mic preamps provide exceptional sound quality, while the compact form factor offers easy transport and fast configuration. Ideal for live engineers, houses of worship, bands, club owners and corporate installations, Soundcraft Mini Stageboxes allow you to replace heavy, expensive analog snakes with a single RJ45 Cat5 style Ethernet cable. (Make: JBL /HARMAN GROUP /Yamaha /TW/QSC/D&B ) Nos 1
4 NS-4 Supply of Bluetooth Audio Reciver The AIR LINK DW 20BR Bluetooth Wireless Stereo Receiver brings the convenience of high-performance audio-streaming to any installed or portable sound system. Specification Outputs Connectors - Balanced XLR, unbalanced ¼" /Impedance - 240 Ω /Max. output level - 4 dBu @ 1 kHz /Bluetooth -Frequency range :-2402 - 2480 MHz / Receiver range - Up to 30 m (100 ft) System Frequency response -20 Hz to 20 kHz (+0/-2 dB) / Signal-to-noise ratio >90 dB /Power adaptor -12 V DC, 400 mA,center positive Make :- Klark Teknik / OEM Each 1
5 NS-5 SITC of cardioid electret condenser microphone with 450mm Lenght or better A filter in the microphone grille shall suppress wind and pop noise. A programmable button shall operate in the operating modes ON/OFF, Push-To-Talk and Push-To-Mute. The microphone button shall be disabled when needed. The frequency response shall be selectable in two stages: linear or with low-cut filter to suppress lowfrequency noise. The LED ring to display the microphone status shall be deactivated when needed. The LED ring integrated in the microphone head shall illuminate red to display the ready-to-speak status of the microphone. The microphone shall have an excellent RFI shielding and is immune to wireless communication devices. The microphone shall operate with phantom power P12, P24 or P48. A preamp with electronically balanced signal output shall be integrated in the base. The gooseneck shall have two flexible 6 mm [0.24"] or better thin elements with a rigid tube in between. The housing shall be black, free from reflections and completely made of metal. The frequency response shall be 50 to 19,000 Hz. The open circuit voltage shall be 17 mV/Pa. The nominal impedance shall be 200 ohms. Each 12
6 NS-6 Supply installation testing & commissioning of Wired Vocal Microphone , Transducer type Dynamic Polar pattern Super cardioid Frequency response: 30 - 18,000 Hz Nominal impedance 600 Ω Connection 3-pin XLR male (Approved Make: Beyerdynamic/Shure/ Sennheiser)/ Equivalent Nos 0
7 NS-7 Supply installation testing & commissioning of Instrument Microphone with high-frequency reproduction ; Polar Pattern: Cardioid, Frequency response : 50-17,000 Hz ; Open circuit voltage : 2.4 mV/Pa, Nominal impedance : 600 Ω, Load impedance : ≥ 2 kΩ, Connection : 3-pin XLR tc. complete with installation as per the site requirement.(Approved Make: Televic/Shure/ Sennheiser) Nos 0
8 NS-8 Supply installation testing & commissioning of Handheld wireless microphone : Wirless Handheld UHF true diversity wireless system, cpl. with NE 600 S and SDM 669, PLL, pilot tone, ACT/SCAN-function, 16 preprogrammed frequencies, incl. softcase, batteries, rack mount brackets, MKV 11 and switching power supply(Approved Make: Televic/Shure/ Sennheiser) Nos 2
9 NS-9 Supply installation testing & commissioning of Lapel microphone : Wireless Lapel UHF true diversity wireless system, cpl. with NE 600 S, TS 601 and TG L55c lavalier microphone, PLL, pilot tone, ACT/SCAN-function, 16 pre-programmed frequencies, incl. softcase, batteries, rack mount brackets and switching power supply (Approved Make: Televic/Shure/ Sennheiser) Nos 1
10 NS-10 Supply installation testing & commissioning of Floor Boxes : Container for electrical connections, usually intended to conceal them from sight and deter tampering. Make - OEM Nos 6
11 NS-11 Supply installation testing & commissioning of Microphone stand (big) : Long Stands for microphone Make- OEM Nos 8
12 NS-12 Supply installation testing & commissioning of Microphone stand (short) : Short Stands for microphone ( Make - Falcom / MX / Kristal OEM ) Nos 6
13 NS-13 Supply installation testing & commissioning of Microphone Cable : Cable with thickness of 2 Core shielded cable Make - ( Falcom / B elden / Kristal ) Mtr 400
14 NS-14 Supply installation testing & commissioning of Microphone Cable : Cable with thickness of 4 pair 8 Core shielded cable Make - ( Falcom / B elden / Kristal ) Mtr 600
15 NS-15 Supply installation testing & commissioning of Speaker Cable : Cable with thickness of 2 Core 2.5 Sqmm Make - ( Falcom / B elden / Kristal ) Mtr 50
16 NS-16 Supply installation testing & commissioning of UL Listed All Type of connectors Like - Rj45,xlr,3.5JACK etc as site requried For inter connection of equipments.Make- OEM , Dlink , Nutrick, MX Lot 1
17 NS-17 SITC of Transmitter and Receiver with scaler 4k capable with HDMI Input and Twisted Pair Output - HDMI Tx & Rx extension module supporting 4K/UHD capability @ 60 Hz with 4:2:0 chroma subsampling Control over one CATx cable for upto 70m HDCP , EDID compliant Input Port: Tx - 1 x HDMI, Rx - 1 x HDBaseT Output Port: Tx - 1 x HDBaseT, Rx - 1 x HDMI 4K/UHD capability @ 60 Hz with 4:2:0 chroma subsampling HDBaseT compatible HDMI, HDCP, CEC, EDID compliant Distance upto 70m PoE Compatible Support RS-232, IR, and CEC control signals over HDBaseT. (Approved Make: Milestone / Linetek/ WyreStrom) Nos 1
18 NS-18 Supply installation testing & commissioning of Class D 4 Zone power amplifier Channels:- 2 ,Sensitivity -1.4V Rated Power Output (per channel)3000W 2Ω, 2100W 4Ω, 1200W 8Ω ,Signal to Noise Ratio (below rated 1 kHz power at 8 ohms) 103 dB (A-weighted) THD< 0.5% Frequency Response (at 1W, 20 Hz - 20 kHz)+ 0 dB, -1 dB Crosstalk (below rated power) 20 Hz to 1 kHz>70 dB Frequency Response 60 Hz~15 KHz ( ± 3 dB ) or better ; THD <0.5 % at 1 KHz, 1/3 rated power or better ; S/N >80dB or better ; Controls Volume control and power switch or better (Approved Make: JBL /RCF /HARMAN GROUP/TW/QSC/Yamaha ) Nos 2
19 NS-19 Supply installation testing & commissioning of Intractive Podium – unmatched interaction with various digital devices. Its ergonomic design allows you to collaborate with your partners, customers, and business associates with technological ease. Its modular form factor provides great productivity benefits, enabling easy mobility of the device. Body : Metallic ,Keyboard Slider : Available ,Document Camera Tray : Available ,Top Sliding: Available ,Electronic Monitor Lift : Available, Touch Monitor : Available ,Monitor Size : 21.5 inch , Gooseneck Mic : Optional Cooling Fans : Available CPU : Optional* Make - Peolelink / Bench Mark /MAXHUB nos 1
Total Schedule Amount (Rs.) Total
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
SBD NIT-16 BAMETI.pdf
NIT • 2.89 MB
NIT-16-Re-Tender, BAMETI.pdf
NIT • 1.83 MB
NIT-16-Re-Tender, BAMETI.pdf
NIT • 1.83 MB
SBD NIT-16 BAMETI.pdf
NIT • 2.89 MB
TB NIT-16 BAMETI.xlsx
NIT • 0.08 MB
FB NIT-16 BAMETI.xls
NIT • 0.15 MB
FB NIT-16 BAMETI.xls
NIT • 0.15 MB
Download all tender documents and submit your bid