BINDEY KUMAR
DIRECTOR
SHEIKHPURA PATNA
BINDEY KUMAR
DIRECTOR
Group D: Obstetrics & Gynaecology Laparoscopic Set
144200
NIT No.28/2026-2027/Bio-Medical Eqpt/IGIMS/Store/D
Open Tender
GENERAL
Sheikhpura
• Status of Bidder:
Manufacturer or Authorized Agent of the Manufacturer
Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER?S AUTHORISATION FORM as per FORMAT placed at Annexure ? III)
• Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
• Certificate towards market standing of minimum 05 years in the area of supply, installation, commissioning and maintenance of IT Equipment?s.
• Certificate for sole ownership / partnership
• Statement of financial standing from bankers
• Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
• Notary certified User List (List of Govt./Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
• Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt. /Semi Govt. /Reputed Pvt. Institutions/organization for the quoted items.
• Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the dept. or Institution after a minimum period of six months of installation
• Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
• Whether rates quoted are inclusive of all taxes or not.
• Whether rates are quoted as per format mentioned in the Bidding Document or not.
• Affidavit to the effect that the bidder is not blacklisted by any Govt. agency or has no pending case either Civil or Criminal against them.
• Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. /Semi Govt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
• Bid Security amount deposited is enclosed or not. If yes, please mention the details.
• Original Technical Catalogue of the quoted model.
• Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of three years as mentioned against each item including all spares, accessories, consumables etc., (Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
• Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of seven years after expiry of warranty period of three years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
• Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document. (Clause No- 13 of ?Instruction to Bidder ?& clause no- 3, 4 and 5 of Condition of contract.)
• Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column.
• Compliance Statement with relation to the terms & conditions as mentioned in the document.
• PAN and copies of Income Tax Returns for the last three years.
• Duly attested copy of GST registration certificate.
• Should have OEM authorization against this tender.
GENERAL
ITEM RATE
L1
1
21 documents required · 21 mandatory
₹2,500
Processing Fee: 1180
Conference Hall (Ground Floor, New Administrative Building), IGIMS, Patna
25 Nov 2026
25 Nov 2026
28 Dec 2026
25 Nov 2026
20 Dec 2026
25 Nov 2026
27 Nov 2026
180 days
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt /IGIMS/Store
A.: To be filled by the bidder and submitted along with the Technical Bid.
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Status of Bidder:
· Manufacturer or Authorized Agent of the Manufacturer
· Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER’S AUTHORISATION FORM as per FORMAT placed at Annexure – III)
2 Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
3 Certificate towards market standing of minimum 05 years in the area of supply and or maintenance of bio-medical equipments.
4 Certificate for sole ownership / partnership
5 Statement of financial standing from bankers
6 Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
7 Notary certified User List (List of Govt.
/Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
8 Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt./Semi Govt.//Reputed Pvt. Institutions/organization for the quoted items. ( same model)
9 Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the deptt. or Institution after a minimum period of six months of installation
10 Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
11 Whether rates quoted are inclusive of all taxes or not.
12 Whether rates are quoted as per format mentioned in the Bidding Document or not.
13 Affidavit to the effect that the bidder is not
blacklisted by any Govt. agency or have no pending case either Civil or Criminal against them.
14 Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. / Pvt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
15 Quality Assurance Certificate like ISI, ISO-9002, IP/BP, CE, FDA (US) or any other (please specify)
16 Bid Security amount deposited is enclosed or not. If yes, please mention the details.
17 Original Technical Catalogue of the quoted model
18 Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of three years including all spares, accessories, consumables etc.,
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
19 Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of seven years after expiry of warranty period of three years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
20 Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document.( Clause No- 13 of “ Instruction to Bidder “ & clause no- 3, 4 and 5 of Condition of contract.)
21 Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column Mere writing” Complied shall not be accepted.
22 Compliance Statement with relation to the terms & conditions as mentioned in the document.
23 PAN and copies of Income Tax Returns for the last three years.
24 Duly attested copy of GST registration certificate.
B: To be filled by the Bidder and submitted along with Price Bid
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Item wise price for the item(s) as mentioned in the Bidding Document and as per format attached as Annexure – I(a) or I (b)
2 Rate for Comprehensive Annual Maintenance Contract as per terms & conditions mentioned in the Bidding Document and as per format attached as Annexure - II
Note: If the above-tender details are not mentioned and required documents are not attached at appropriate places, the offer of the bidder(s) shall be summarily rejected. Hence, bidder(s) are advised to go through the bidding document carefully and tender be prepared with all the required documents to avoid rejection of offer.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt /IGIMS/Store
ELIGIBILITY CRITERIA Mentioned Page no.
1 Manufacturers or their authorized dealers/Indian subsidiaries/direct importers having a place of business in any of the States of India are eligible to participate in this tender.
2 The bidder and manufacturer of the equipment offered should be in the business of the supply and installation of same / similar equipment for the last five calendar years.
3 (a) The manufacturer should have completed at least 05( Five ) nos. installations of the quoted items in Govt. /Pvt. Institutions /Hospitals in India. The installations mentioned by the manufacturer in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
(b) The bids quoted as the authorized representative of the manufacturer meeting the above criteria 02 (a) should have also supplied and installed at least 03( Three) nos. installations of the quoted items in Govt. /Pvt. Institutions/ Hospitals in India in last five years from the last date of submission of tender. The installations mentioned by the authorized representative in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
4 The Bidder should be public undertaking /Autonomous Body /Public Ltd./Pvt. Ltd. Company or proprietary firm /Partnership Firm and should be in medical equipment business since last five years in India. The Bidders having manufacturing facility in their name in India for the majority of the items offered by them shall be given preference.
5 The Bidder (manufacturer or their authorized agent) should have had average annual financial turnover of Rs. 50 Lakh during the last three years ending s 31st March 2026.
6 Bidders who have the capability to attend repairs of these equipment within the time mentioned in this bidding document and who are willing to provide stand by equipment or replace the faulty equipment if the repair/down time extends beyond 72 hours from the time of reporting of the fault within the next 48 hours (total down time should not exceed 5 days in one instance). The bidders who have the capability to ensure the uptime mentioned in this document (Documentary proof shall be submitted on the after sales facilities and expertise of the bidder.)
7 Bidders are not offering the equipment of a firm /company that has
been blacklisted by Indira Gandhi Institute of Medical Sciences – Patna or blacklisted/debarred by any other State / Central Government's organization.
Note: Notwithstanding anything stated above, the Institute reserves the right to assess the Bidder’s capability and capacity to perform the contract satisfactorily before deciding on award of contract, should circumstances warrant such an assessment in the overall interest of the purchaser.
The Institute reserves the right to ask for a free demonstration of the quoted equipment at a pre determined place acceptable to the purchaser of technical acceptability as per the tender specification, before the opening of the price tender.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- Group D
1: Laparoscopic Set
4K UHD Medical Grade Monitor Screen Size of 32 Inch (From Same OEM) or more – 01 No. and 55 inch or more (From Same or Different OEM along with MDD Certified Product to use inside the OT): 01 No. :–
The monitors should have following specification :
2- Dimensional endoscopic video camera in 4K resolution (3840*2160)
3-Dimensional endoscopic video camera in 4K resolution (3840 *2160)
Slot for Video Scopes (Digital Scopes/Chip on tip) like Video Choledochoscope, Video Cystoscopes etc.
· 3D in 4K resolution
· 2D in 4K resolution
· 2D in Full HD resolution
· 3D in Full HD resolution
· Facility to be connected to 4K UHD and FHD video source.
· Color Space – BT.2020 emulation.
· Aspect ratio : 16:9 or better.
· Effective Resolution : 3840 X 2160 Pixels.
· Inputs : 1 x DP 1.2, 1 x DVI–D, 1 x 3G–SDI / 1 x 12G SDI / 1 x HDMI 2.0, 1 x USB.
· Outputs : 1 x DVI–D, 2 x 3G–SDI / 1 x 12G SDI.
2. 4K UHD Camera Control Unit (CCU) :
· The system should be digital endoscopic video camera with maximum resolution of 3840 x 2160 pixels and progressive scan to guarantee genuine 4K.
· The system should have facility of 3x Digital Zoom Lens or more.
· System should have facility to offer various visualization modes for surgery and diagnosis by shifting the color spectrum like BLUE & GREEN light for recognition of the finest tissue structures and their differentiation / ICG florescence technology for biliary mapping, blood flow, vascularity. (If any hardware / software requirement for this said facility, then bidder / manufacturer has to quote it as optional in Schedule XI as Percentage).
· The CCU should be complete with all accessories so as to connect 4K UHD Telescope and process and display the signals in their native resolution.
· Picture in Picture of visualization modes.
· Automatic adjustment of light source intensity.
· Resolution : 3840 x 2160 Pixels.
· Video output : 1 Display Port 1.2 / 2 XHDMI,1 x DVI–D output, 1 x 12G–SDI output, LAN connection, 4 x USB connection.
· Input : Keyboard input for character generator.
3. 4K UHD Camera Head :
· Pixels : 3840 x 2160 Pixels.
· Microprocessor controlled.
· Lens : Integrated Zoom Lens, f = 18 mm.
· Color Space : BT.2020 emulation.
· Must have different control buttons to control the camera functions / presets from sterile zone (at least one of them freely programmable).
· The surgeon should not feel any heat output from the camera head during long procedures.
4. Light Source 400 W LED / Xenon with Fiber Optic Cable – 01 No. :
· Cold Light Fountain / Xenon Light Source which also be suitable to use for ICG technology.
· Lumens : 2000 and above / equivalent top 300 watt Xenon.
· Color Temperature : approximately 6000 K.
· Should have touch display which provides an intuitive & user-friendly interface that directly displays relevant data.
· Lamp life of approx. 30,000 hrs (or more) (if xenon light source the bidder will supply minimum 5 xenon bulb with the system & time to time replacement of xenon bulb must be responsible of bidder / manufacturer till the equivalent of lamp life of 30000 hours).
· 4.8 mm fiber optic cable and 300 cm long (02 Nos.).
· Certified To : IEC 601–1 & UL 544 CE, according to MDD, protection class 1 / CF.
5. 4K UHD Image / Video Recording and Data Archiving System (From same or Different OEM along with MDD / Certified product to use inside the OT) :
· State of the art user friendly medical grade system from same or different OEM (certified to be used in OT) should be offered with following features :
· User should have full control of the system from the sterile field via camera head buttons, optional touch screen or optional foot switch.
· Still images and videos (optional with audio) in 2D or 4K UHD.
· Internal memory : minimum 2 TB.
· Playback of 2D and 4K UHD content.
· Must have an touch panel support display size of 10" to control the image management system & for simplification of data input. (approximately).
· Classification : MDD, CSA.
· Must have ergonomically designed space to arrange all the laparoscopic systems, camera head as well as proper handles for easy movements.
· Good size lockable dual castors having controls for straight movement.
· Must have adequate number of power points with switches with safety features.
· Must have a power cord of minimum 3 meter length.
7. Electronic Thermo Insufflator :
· Fully automatic electronically microprocessor controlled gas filling system.
· Flow rate of 30 – 40 litres per minute.
· Audio visual signals in case of malfunction or excessive pressure.
· Connectible to CO2 from medical gas pipeline / cylinders.
· Easily accessible control keys on front / top panel.
· Side by side display of actual and preset parameters : flow rate, pressure and gas consumed.
· Should have feature like pre heating of gas to body temperature.
· Should have feature easy evacuation of smoke and mist.
· Memory for retention of previous pressure settings.
· Should include pin-index connection to small / big gas cylinder with regulator, high pressure hose, mains cord, silicone tubing set – 02 Nos., universal wrench and gas filter – 05 Nos.
8. Irrigation Unit :
· Pump for irrigation and suction.
· Maximum irrigation pressure 400 mm Hg.
· Suction pressure 0.75 bar.
· Control from control panel and / or foot pedal.
· Overflow protection on suction bottles.
· Accessories should include silicone tubings – 02 Nos., bacterial filter – 05 Nos. and bottles with cap.
9. 4K Telescopes :
All telescope should have following :
Low risk of object burn, Colour coded for identification, Autoclavable, Fibre optic light transmission incorporated.
Compatible Telescopes with the 4K system should be quoted with dimensions as below :
· 10 mm, 0 Degree, 29 cm or more working length – 02 Each.
· 10 mm, 30 Degree, 29 cm or more working length– 02 Each.
· 5 mm, 0 Degree, 29 cm or more working length – 01 Each.
· 5 mm, 30 Degree, 29 cm or more working length – 01 Each.
10. Telescopes for 3D in 4K resolution with integrated camera head
· 3D imaging via two distal 4K sensors
· Camera and Telescopes should be one piece
· 10mm 30 degrees - 1 No.
· Switching of 3D to 2D can be done.
· Free from Focus and Depth of Filed should be 30-200mm
· Autoclavable.
· Sterilization tray for the scope should be quoted.
· 3D Should be able to perform both White light and Near Infrared application.
· Reusable Veress 10 & 13 cm Pneumoperitoneum Needle : Spring loaded blunt stylet luer lock length 10 / 15 cm.- 02 No. Each
· Reusable Trocar : 5 mm : Multifunctional valve, insufflation stopcock and threaded sleeves, pyramidal tip, length (10.5 cm). 04 No.
· Reusable Trocar : 10 / 11 mm : Multifunctional valve, insufflation stopcock and threaded sleeves, pyramidal tip, length (10.5 cm). 04 No.
· Reusable Trocar : 12 mm : Multifunctional valve, insufflation stopcock and threaded sleeves, pyramidal tip, length (10.5 cm). 04 No.
· Safety Trocar with Port : 10 mm length approx 10.5 mm. 04 No.
· Spare Sealing Trocar Caps for Trocar : 5 – 6 mm. 05 No.
· Spare Sealing Trocar Caps for Trocar : 10 – 11 mm. 05 No.
· Reusable Reducer Sleeve : 10 / 11 mm to 5 / 4 mm. 02 No.
· Reusable Reducer Sleeve : 12 mm to 6 / 5 mm. 02 No.
· Suction and Irrigation Cannula : Size 5 mm, length 36 cm, used with suction & irrigation handle. 02 No.
· Grasping Forceps – Toothed 2 x 4 Teeth : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Grasping Forceps – Toothed 2 x 3 Teeth : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Maryland Forceps : Double action jaws , rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Grasping Forceps – Atraumatic : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Grasping Forceps – Allis : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Grasping Forceps – Rt Angled : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Grasping Forceps – Mixter : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Grasping Forceps – Plain Dissection & Grasping : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Grasping Forceps – Babcock : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Hook Scissors : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Micro Scissors : Single / Double action jaws, size 5 mm, length 33 – 36 cm. 02 No.
· Laparoscopic Knife : 5 mm, 30 – 36 cm length. 02 No.
· Rotating Metzenbaum Scissors : Double action jaws, rotating with connector pin for unipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Bipolar Coagulating Forceps : Size 5 mm, length 33 – 36 cm fenestrated. 02 No.
· Bipolar Coagulating Forceps : Size 5 mm, length 36 cm, 3 mm width of jaws. 02 No.
· Maryland Bipolar : Double action jaws, rotating with connector pin for bipolar coagulation, size 5 mm, length 33 – 36 cm, dismantling facility. 02 No.
· CO2 Connector : Compatible with CO2 "B" type cylinder. 02 No.
· High Frequency Cord : For 5 mm & 10 mm hand instruments with monopolar electrodes, spatula tip. 02 No.
· High Frequency Cord : For 5 mm & 10 mm hand instruments with monopolar electrodes, hook tip. 02 No.
· Knot Pushers : Eye type, length 33 – 36 cm. 02 No.
· Needle Holder Coaxial Type : Size 5 mm, tungsten tip, straight handle with ratchet, single moving jaw, length 33 – 36 cm. 02 No.
· Assistant Needle Holder : Size 5 mm, tungsten tip, straight handle with ratchet, single moving jaw, length 33 – 36 cm. 02 No.
· Clip Applicator – Medium Large : Rotatable, provision for locking the shaft conveniently, 10 mm, compatible with clip. 02 No.
· Trocar under Optical Vision : Trocar with endo tip size : 10 mm & 5 mm, cannula rotatable with multifunction valve, working length : 11 cm. The endo tip cannula should compatible with 10 mm telescope for under vision entry into peritoneum. 02 No.
· Grasping Forceps – Toothed 2 x 3 Teeth: Double action jaws, rotating with connector pin for unipolar coagulation, size 10 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Grasping Forceps – Toothed 2 x 4 Teeth: Double action jaws, rotating with connector pin for unipolar coagulation, size 10 mm, length 33 – 36 cm, dismantling facility. 02 No.
· Suction Irrigation Cannula: 10 mm. 02 No.
· Hassan Cone: Adaptable to 10 mm trocar. 02 No.
· Bowel Grasper: 10 mm fenestrated, rotatable. 02 No.
· Blunt Obturator: For 11 mm port. 02 No.
· L – Hook: Size 5 mm, length 33 – 36 cm with pin for cautery, well insulated hook with small un- insulated working part. 01 No.
· Spatula : Size 5 mm, length 33 – 36 cm with pin for cautery. 01 No.
· Fascia Closure Instrument: Size 2.8 mm, length 17 cm. 01 No.
· Washers : For 5 & 10 mm cannula and reducers. 02 No.
· Container : Metal & Plastic : For sterilization and storage of telescopes different sizes. 02 No.
· Container : Metal & Plastic : For sterilization and storage hand instruments and other accessories, different sizes. 02 No.
· Uterine Manipulator, complete consisting of: Handle, Manipulator, Sheath Cap, diameter 37 mm, length 30 mm Cap, diameter 42 mm, length 30 mm Spiral Insert, diameter 15 mm Spiral Insert, diameter 20 mm Working Insert, length 60 mm Working Insert, length 40 mm Tube Connector, length 190 mm 2x 27500 LUER-Lock Tube Connector The set indicated here only takes into account the instrument setting for Total Laparoscopic Hysterectomy. 01 No.
11. Additional Terms and Condition :
· All the Equipments & instruments are from same manufactures / OEM to avoid compatibility issues and to get better service support through out the warranty & CMC period.
· Prices of all Equipments / Instruments / Consumables / Accessories must be quoted and consider as rate contract through out the CMC & Warranty period of the tender.
Price of all items mentioned in the BOQ must be considered for price evaluation.
12. Standards, Safety and Training :
· Should be FDA / CE / UL / BIS / CDSCO approved product.
· Manufacturer should have ISO certification for quality standards.
· Comprehensive training for users and support services till familiarity with the system.
· Electrical safety conforms to standards for electrical safety IEC 60601–1 (Or equivalent International / National Standard) General Requirement for Electrical Safety of Medical equipment.
· The equipment complies with the requirement of the Medical Device Directive of Class I Equipment and Electromagnetic Compatibility; all supporting documents must be provided.
13. Documentation :
· User / Technical / Maintenance manuals to be supplied in English.
· Log book with instructions for daily, weekly, monthly and quarterly maintenance checklist. The job description of the hospital technician and company service engineer should be clearly spelt out.
· Cost of spare parts, consumables and accessories not mentioned in the BOQ and which are not covered under warranty & CMC period, has to quote in Schedule XI as percentage value in the Technical Bid. List of consumables with price frozen for 10 years, or else will be consider to be cover throughout the warranty & CMC period.
· Calibration and Routine Preventive Maintenance Support as per manufacturer documentation in service / technical manual has to be done throughout the warranty & CMC period.
· Compliance report to be submitted in a tabulated and point wise manner clearly mentioning the page / para number of original catalogue / data sheet and the offer details has to submit in the technical bid. Any point, if not substantiated with authenticated catalogue / manual, will not be considered.
· Certificate of inspection and quality control indicating the S / N for all non-consumable items with date at the time of installation.
· All the technical specifications accepted in the compliance statement must be supported by Original Literature from the firm / OEM with Highlighting, Numbering & Flagging in the compliance statement.
14. Environmental Factors :
· Shall meet IEC–60601–1–2 : 2001 (Or Equivalent BIS) General Requirements of safety for Electromagnetic Compatibility or should comply with 89 / 366 / ECC; EMC–Directive.
· The unit shall be capable of operating continuously in ambient temperature of 30 – 40 deg C and relative humidity of 15 – 90 %.
· The unit shall be capable of being stored continuously in ambient temperature of 10 – 40 deg C and relative humidity of 15 – 90 %.
15. Warranty and Maintenance :
· Mandatory 2 PMs / Year with unlimited breakdown calls has to be attended by the bidder / manufacturer throughout the warranty & CMC period at site i.e. NEIGRIHMS, SHILLONG.
Duly signed Mandatory PM reports has to be submitted periodically, falling which necessary action will be initiated as per term& condition of the tender.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- D
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
LOCATED WITHIN INDIA.
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
EMAIL ID OF AGENCY
Scheduled Brief description of goods Make: Model: Country of origin Qty./Nos. Ex-factory/ Ex-warehouse/ Ex-Showroom/ off-the shelf (a) Excise duty (If any) % and value. (b) GST (If any) % and value (c) Pcaking and forwarding charge (d) Inland transportation, isurancer for a period inculing 3 months delivery, loading/unloading and incidental cost till consignee site. (e) Incidental services (Including installation and commissioning, supervision, demonstration and training) at the consignee site. (f) Unit Price( at consingee site basis (g) a+b+c+d+e+f Total unit price (at consignee site) Basis Rs. 4x5 (g)
TOTAL AMOUNT IN FIGURE
TOTAL AMOUNT IN WORDS
Note: Bidders are requested to submit price bid in above format otherwise the bid submitted will be regected.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/ 2026-2027/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- D
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
COMPREHINSIVE ANNUAL MAINTENANCE CONTRACT PRICES SCHEDULE
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
S. No. Item Description 1st Yr. 2nd Yr. 3rd Yr. 4th Yr. 5th Yr. 6th Yr. 7th Yr. Total Comprehensive annual maintenance contract over a period of seven years after expiry of warranty period of three years from the date of successful installation. (a+b+c+d+e+f+g)
a b c d e f g h i
1 Name of the equipment Make: Model: Qty:
2 Name of the equipment Make: Model: Qty:
3 Name of the equipment Make: Model: Qty:
4 Name of the equipment Make: Model: Qty:
5 Name of the equipment Make: Model: Qty:
6 Name of the equipment Make: Model: Qty:
7 Name of the equipment Make: Model: Qty:
8 Name of the equipment Make: Model: Qty:
9 Name of the equipment Make: Model: Qty:
10 Name of the equipment Make: Model: Qty:
11 Name of the equipment Make: Model: Qty:
12 Name of the equipment Make: Model: Qty:
13 Name of the equipment Make: Model: Qty:
14 Name of the equipment Make: Model: Qty:
15 Name of the equipment Make: Model: Qty:
16 Name of the equipment Make: Model: Qty:
17 Name of the equipment Make: Model: Qty:
18 Name of the equipment Make: Model: Qty:
19 Name of the equipment Make: Model: Qty:
20 Name of the equipment Make: Model: Qty:
Scope of contrct (details as mentioned in the clause No. - 13 of "Instruction to Bidder" & Clauses No. 3,4 and 5 of Condition of Condition of Contract".)
a) The rate of Comprehensive Annual Maintenace Contract as mentioned above shoul cover the Complete system.
Complete System should include the basic unit and allied supporting components like UPS, stabilizer Computer System,
Printer, De-ionizer, dehumififer etc to be supplied by the bidder along with basic unit.
b) Preventifve maintenance visit: Four Maintenance visits at ragular interval for usual mintenance & supervision failing which
25% of the contract amount per visit would be deducted as penalty.
c) Break down maintenance visit: As & when requrd
d) Response Time: Within 48 Hours.
e) Uptime Guarantee: 95% of 365 days
f) The above-mentioned charges should includes labour charges for maifntenance and breakdown visits per year, spares,
accessories and all type of consumables requird for the maintenaed charges: it should be clearly mentiond with frequency of
replacement and with rate. The validity of rate of suchf items should also be mentioned vclearly. What will be the rate of
such item must be mentioned.
g) Payment of Comprehensive Annual Maintenance Contract would be made on half yearly basis after completion of work and
satisfctory working report . In no case, advance payment is to be considerd.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Bidding 28.pdf
NIT • 1.00 MB
Tender Notice (Website).pdf
NIT • 0.55 MB
TechnicalSheet.xls
NIT • 0.09 MB
PriceBid.xls
NIT • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .