Loading…
Loading…
Tender ID
Tender Value
₹12.4 L
EMD Value
₹24,841
Closing Date
19 Mar 2026, 11:00 amClosed
Executive Engineer
Sector 11B, Chandigarh
Construction of Extension Block in Dispensary (Health and Wellness Centre) Sector 11, Chandigarh (IBM Scheme No. W1/2023/21882) (Air Conditioning Work)
2026_CHD_91227_1
PH7/2026/2652620
Open Tender
Public Health Products
Percentage
60 days
Chandigarh
Please refer to tender docs
2 documents required · 2 mandatory
₹0
₹24,841
13 Mar 2026
13 Mar 2026
19 Mar 2026
13 Mar 2026
19 Mar 2026
13 Mar 2026
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
HI - WALL SPLIT SYSTEMS Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary C10 compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only
1.5 TR with 5 Star BEE Rating
2.0 TR with 5 Star BEE Rating
TOWER TYPE SPLIT UNITS Supplying, Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 5.5 Mtr (IDU to ODU), i/c drain pipe of suitable length and size. R-32/R-410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required. Heating & Cooling
3.3 TR BEE 4 Star Rating
Providing & Fixing of Powder coated ready made heavy duty out door stand for out door unit as per site requirement to the entire satisfaction of Engineer- in Charge.
Providing & fixing of 3 core 2.5 sqmm flexible copper wire as per ISI specifications including connections etc. of approved make Havell/ Finolex/Ecko/Polycab etc. complete in all respect at site.
Providing and Fixing of PVC Rigid drain Pipe complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials Diplast Or Equalivent.
Providing and Fixing of 22 gauge soft copper piping of size 3/8” & 5/8” or as per original manufacturer of A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing to original condition. The rate per meter includes cost of 1 meter each of both 3/8” & 5/8” with insulation.
Providing and fixing of Voltage Stablizers with copper winding input range 170-280 volts nominal output 230 Volts +/- 10% complete in all respect. Make: Deol, Jewel, V-Guard or Equivalent
5 KVA Capacity
Providing and fixing water cooler full body stainless steel SS 304 with non CFC hermeticaly sealed reciprocating/ rotary type compressor complete in all respect 380-400 of approved make
P/F of Hi Flow water Filter-cum-Purifier including installation charges 3 Ltr/Minute. Make Aqua guardrd/Kent/Usha/Pure-it
Providing and fixing of MCCB 2 pole 32 Amp single phase compplete in all respect to the entire statisfaction of EIC as per approved make list.
Providing and fixing of PVC trunking batten copper pipe, drain pipe and wire in case exposed on walll.
Providing core cutting in brick and RCC wall by means of mechanioical equipement as direction by EIC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 16.16 MB
BOQ_111558.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .