Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-Finance | ₹1.4 Cr | L1 | Accepted-Finance Accept |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Feb 2026, 6:00 pmClosed
SE PHED Deeg
SE PHED Circle Deeg
Annual Rate Contract for Supply Installation of Motor Pump sets in existing sources in Division Kaman, District Deeg including defect liability period of Two year
2026_PHCJA_540779_1
NIT No 35/25-26
Open Tender
Civil Works - Water Works
kaman
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer PHED Kaman
₹80,000
Yes
30 Mar 2026
20 Feb 2026
27 Feb 2026
20 Feb 2026
26 Feb 2026
20 Feb 2026
Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
Up to 5.5 KW (7.5 HP) & head above 120 mtr.
7.5 KW (10 HP) & head up to 120 mtr.
7.5 KW (10 HP) & head above 120 mtr.
9.3 KW (12.5 HP) & head up to 120 mtr.
9.3 KW (12.5 HP) & head above 120 mtr.
11 KW (15 HP) & head up to 120 mtr.
11 KW (15 HP) & head above 120 mtr.
13 KW (17.5 HP) & head up to 120 mtr.
13 KW (17.5 HP) & head above 120 mtr.
15 KW (20 HP) and above, head up to 120 mtr.
15 KW (20 HP) and above, head above 120 mtr.
Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
Up to 5.00 HP
Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
Above 5 HP and up to 10 HP
Above 10 HP and up to 15 HP
Above 15 HP and up to 20 HP
Above 20 HP and up to 30 HP
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
3 core 4.0 Sq.mm
3 core 6.0 Sq.mm
3 core 10.0 Sq.mm
3 core 16.0 Sq.mm
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
10.0 Sq.mm, 4 core
16.0 Sq.mm, 4 core
25.0 Sq.mm, 3.5 core
35.0 Sq.mm, 3.5 core
Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
32 mm dia
50 mm dia
65 mm dia
Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.
63 mm dia
75 mm dia
90 mm dia
Providing, installation, testing and commissioning of Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm (water immersed, dry air filled, class "F" insulated TEWC motor integrally mounted on volute casing pump sets for drinking water) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.
Discharge 20 to 30 LPS and head 20 to 30 M
Discharge 20 to 30 LPS and head 31 to 40 M
Discharge 20 to 30 LPS and head 41 to 50 M
Discharge 31 t0 40 LPS and head 20 to 30 M
Discharge 31 t0 40 LPS and head 31 to 40 M
Discharge 31 t0 40 LPS and head 41 to 50 M
Discharge 41 t0 50 LPS and head 20 to 30 M
Discharge 41 t0 50 LPS and head 31 to 40 M
Discharge 41 t0 50 LPS and head 41 to 50 M
Discharge 51 to 60 LPS and head 20 to 30 M
Discharge 51 to 60 LPS and head 31 to 40 M
Discharge 51 to 60 LPS and head 41 to 50 M
Discharge 61 to 70 LPS and head 20 to 30 M
Discharge 61 to 70 LPS and head 31 to 40 M
Discharge 61 to 70 LPS and head 41 to 50 M
Discharge 71 to 80 LPS and head 20 to 30 M
Discharge 71 to 80 LPS and head 31 to 40 M
Discharge 71 to 80 LPS and head 41 to 50 M
Discharge 81 to 90 LPS and head 20 to 30 M
Discharge 81 to 90 LPS and head 31 to 40 M
Discharge 81 to 90 LPS and head 41 to 50 M
Discharge 91 to 100 LPS and head 20 to 30 M
Discharge 91 to 100 LPS and head 31 to 40 M
Discharge 91 to 100 LPS and head 31 to 40 M
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
NIT35TD.pdf
Tender Documents • 2.08 MB
BOQ_964021.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid