| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹32.0 L+₹2.5 L (8.50%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIRS TO ROOF WATER PROOF TREATMENT AND REPAIR OF SUNKEN FLOOR WALLS AND CHAJJA AT MH AND RH AREA UNDER GE MH AND RH KIRKEE
2020_MES_385785_2
8154/E8
Open Tender
Civil Works
Item Rate
180 days
KIRKEE AND AUNDH
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH RH KIRKEE
₹80,000
Yes
11 Jan 2021
17 Nov 2020
12 Dec 2020
17 Nov 2020
11 Dec 2020
28 Nov 2020
17 Nov 2020 - 23 Nov 2020
60 days
Amount
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for and M & L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregates for filleting, benching, slightly rounding or chamfering on edges, filling undulations / depressions in roof surface, providing concrete platform for tanks wherever required as directed.
Taking down / removing existing water proofing treatment from RCC roof slab including removal of plaster bed below felt / membrane and disposal of the same to distance exceeding 50m but not exceeding 100m as and where directed and M & L for 10 mm thick screeding / rendering in cement mortar 1:4 on concrete roof surface, using Water Proofing Compound @ 3% by weight of cement, surface finished even and smooth without using extra cement all as directed. Note: Water Proofing Compound shall be measured and paid separately.
Supply only intergral water proofing compound.
Demlotion of cement concrete of any description and in any position not otherwise specifically provided for all as specified.
M & L for cleaning the plastered /concrete surface with wire brush and applying water proofing treatment as under:- (a) Apply a uniform coat of primer at 0.70 Kg/sqm over cement plaster. (b) 3mm thick and weighing not less than 3.6 Kg/sqm Atactic Polypropylene Polymer (APP) modified bitumen - based prefabricated five layer water proofing membrane reinforced with non woven polyester mattt black finished over compatible primer at 0.40 Ltr/Sqm of density at 25 degree centigrade 0.87 - 0.89 Kg/litre and viscosity 70-160 cps or cold sticker and torch application of membrane with 10 cm overlap both ways after necessary preparation of surface complete as per manufacturers instructions. (c) Apply two coats of bitumastic - aluminium paint over the membrane.
M&L for waterproofing treatment to RCC sunken slab as specified below. Make: PIDILITE or equivalent:- (a) Clean the sunken protion of toilet/Bath/WC/Kitchen throughly to remove laitance, dirt, dust etc. (b) Form angle fillet of size 40mm x 40mm along the junction of wall and floor using polymer modified mortar (Dr Fixit Pidicrete URP or eqpt). (c) Sanitary pipes entering through walls and floors shall be sealed with "Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout " Dr Fixit Bathseal Grout" or eqvt Nahani traps to be fitted securely and the gaps around it to be grouted in the same manner. (d) Apply one coat of a Bitumen modified polymer coating "Dr Fixit Bathseal Plus" or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely. (e) In the remaining area, in dry sustrate condition brush apply first coat of the same coating and further apply second coat when first coat is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproof coating "Dr Fixit Pidifin 2 K " or eqvt can be further applied right upto 2.1m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely. (f) After 2 to 3 days , sunken portion must be overlaid with a 50mm thick concrete screed M 15 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2. (g) After completing plumbing work in the toilet /WC/Bath Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile adhesive and ready -to-make Tile grouts of appd makes such as Dr Fixit, FOSROC SIKA, MC BUCHEMIE, ROFF, etc
M & L PCC (1:5:10) using 40mm graded aggregate as in mass concrete or as in sunken floor complete all as specified & directed
Cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment/surface and M&L for carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
Cleaning the surfaces of kitchen sunk (mori) with wire brush, detecting the sources of leakages and replacement of any defective fittings/fixtures of any type Imaterial like material like Nahani trap of 100 mm dia etc, sealing the joint of pipe/nahani trap with surrounding using PU sealant of Pidilite or equivalent, and M&L for replastering with 15mm thick in cement mortar 1:3 mixed with water proofing compound as per manufacturers instructions by providing slope at Nahani Trap'with good finishing all as specified and directed. Note :- The quoted rate shall be inclusive of cost of waterproofing compound, PU sealant and Nahani Trap.
Making hole and M&L for fixing thr metallic packer for hydrophobic PU foam and Sealer as per manufacturers specification. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
Open the fittings like Y, bend, Tee etc from the outlet pipe filing properly the loose joint between bend and outlet pipe with solvent and fixing properly to ensure leakage free joint and making good
M&L for water proofing treatment of External walls DFT: 110 microns by applying two coats of elestromeric coating Raincoat, material covering capabity 3 Sqm per litre in 2 Coats without dilution & 1 coat of efflorescent resistant primer 10sqm/litre/coat after cleaning the surface throughly and sealing all cracks with acrylic sealing compound as per the manufacturers specifications and directions of Engr-in-Charge Make :- Raincoat shall be of PlDlLlTE or equivalent. The product shall have following properties: Elongation > 100% as per ASTM D 412, Tensile strength : 2.5 Mpa as per ASTM D 412, Water Resistance conforming to SS 500, Crack bridging ability conforming to Class A4 as per EN 1062 Part 7, Positive hydrostatic pressure > 7 bar as per DIN 1048, Anti-carbonation property complying EN 1062 Part 6, RCPT conforming to ASTM C 1202.
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tile with heavy duty tile cleaner preferbly of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, or equivalent , curing , cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
Cleaning the surfaces of existing RCC Slab with wire brush and M&L for application of one coat of CORE COAT LP (F) minimum 1mm thick (12 to 14Sqm per coat for 1mm thick coat per pack) or equivalent approved in PIDILITE and grouting with a coat of neat cement slurry using 2.70 Kg /Sqm of cement admixed with liquid water proofing admixture and one coat of SBR cement all as directed. Make :- Core coat shall be of Buildcore Chemical /or equivalent approved product of PIDILITE.
Cleaning the surfaces of existing RCC Slab with wire brush and M&L for application of 2 coats of Fastflex, minimum 1mm thick (1.5Kg/sqm) or equivalent approved in PlDlLlTE and grouting with cement slurry using expansive additive Pidicrete AM, @ 225gm/bag of cement and one coat of SBR latex all as directed. Make :- PIDILITE or equivalent, all as directed by Engineer-in-Charge.
M&L for treating the dampness of wall with Siliconate injection grout (The spacing of holes shall be 2 Nos holes in every 1m) by making 12mm to 15mm holes at an inclination of 455 degrees to the extent of 112 to 3/4 of the wall thickness and inject the diluted chemical liquid (1 :4) (Min 10 Ltrs), in the lowest possible point by using a pressure grouting machine with a pressure of approximately 3 Kg/sqcm' till the point of return of liquid and seal the treated holes with suitable compound and washed thoroughly the treated areas with water all as directed.
Water proofing treatment to RCC UG sump/RCC water retaining Over head tank etc of any height and radius etc by Prowding & applying 2 coats of two component acrylic based, food grade cementitious based water proofing system, Fastflex on all over the areas and joints, after cleaning it With high pressure waterjet with necessary surface preparation by hacking Wire brushing , cleaning loose particles by wire brush , cutting cold joints, junctions by 50X50mm groove by means of electric breaker and pack it with extra strong SBR based cement sand mortar(1 :3) after pre wetting the RCC surface then apply two coats bonding agent @ 0.65Kgs/Smtr per coat . The system includes treatment wth two coats on joints where ever required as per manufacturers specification, etc, complete. The product shall have Tensile strength : 2.6 N/mm2 as per ASTM D 412, Elongation at break, % : 120 as per ASTM D 412, Adhesion strength : 1 N/mm2 as per ASTM D 4541, crack bridging : 2mm as per ASTM C 836, Water penetration (5 bar pressure) : 1% as per BS EN 12390, Hardness, Shore A : 60 as per ASTM D 2240, RCPT permeability : 92% as per ASTM C 1202-97.
Providing & applying 15 to 25mm thick (avg) waterproof screed plaster on vertical & horizontal RCC surface over the treated layer with CM (1:4) using cement sand mixed With waterproofing admixture LW+, make as approved by the Engineer, etc, complete, & trowel finish the surface as directed by the Engr-in-Charge followed by filling the water retaining structure, for 24 hrs to obtain water tightness test result.
M&L for cutting our cracks to V-section in existing roof or terrace, cleaning out, and filling solidly with a cement and clean dry sand 1:1 (by weight) , all as specified and directed.
M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM (1:3) with WPC, finished even and smooth without using extra cement all as specified and directed
S&F Rolled sections of Fe-410-W (Gde E-250) quality as in main and cross beams , hip and jack rafters, purlins where connected to common rafters and running rails etc with angle cleats or other connecting plates all as specified and directed by the Engr-in-Charge.
Dismantling asbestos cement (corrugated, semi-corrugated etc) as in roof coverings and S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550 Mpa as in roof coverings /cladding to wall , fixed with self tapping screws as specified and directed.
Dismantling of CI pipes or PVC pipes upto 150 mm dia fixed to wall etc complete all as specified and directed.
Dismantling of CI pipes or PVC pipes 100 mm dia fixed to wall etc complete all as specified and directed.
S&F in repairs 100mm cast iron sanitary connection socket to fit WC out-let, all as specified and directed by engineer-in-charge.
S&F in repairs 75mm bore Cast iron cowls, all as directed.
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store
Taking up or down steel tubing of 25 to 32 mm bore and connections, including cleaning for re-fixing or removal to store
Supply & fixing mild steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel tubes of size 25 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed
S&F in repairs Cast iron soil 100 mm bore , waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors , or in any position all as specified and directed.
S&F in repairs Cast iron floor trap 100 mm bore with grating including jointing to waste pipe and fixed with PCC 1:2:4, all as specified and directed.
S&F in repairs Cast iron bend 100 mm size with duck's foot or heelrest , all as specified and directed.
S&F in repairs Cast iron bend 75 mm size with duck's foot or heelrest , all as specified and directed.
S&F in repairs Cast iron branch piece single 100 mm bore with duck's foot or heelrest all as specified.
S&F in repairs Cast iron branch piece single 75 mm bore with duck's foot or heelrest all as specified
S&F in repairs Cast iron soil 75 mm bore , waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors, all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises complete all as specified and directed.
M&L Coloured ceramic tiles in vertical surface 300x200mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile laid over and including 10 mm thick backing coat in CM 1:4 all as directed.
M&L Coloured ceramic tiles in vertical surface 300x450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile laid over and including 10 mm thick backing coat in CM 1:4 all as directed.
M&L non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry to match the work using colour tiles over screed bed on bedding layer of mortar 15mm thick is CM 1:6 over cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in floors 25 mm thick, all as specified and directed.
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:4) complete all as specified and directed.
Renewing Glazed ceramic tiles of any sizes and Colour/shade in patches, area n exc 5 Sqm including removing and cleaning old tiles, preparing beds and laying or setting , jointing and pointing new or tiles complete all as specified and directed
Dismantling water tanks and removing to store of 500 ltr capacity all as specified and directed.
Dismantling water tanks and removing to store of 1000 ltr capacity all as specified and directed.
Dismantling water tanks and removing to store of 2000 ltr capacity all as specified and directed.
S&F in repair rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part- I of capacity 500 ltrs all as specified and directed .
All as per item No 49 but of 1000 ltrs capacity all as specified and directed.
All as per item No 49 but of 2000 ltrs capacity all as specified and directed.
S&F in repairs 20mm Ball PTMT valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed.
S&F in repairs 15 mm Ball PTMT valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed.
S & F in repairs PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and directed. (Make : CERA, Hindware or Equivalent )
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, sheet cover complete all as specified and directed.
S&F in repair bib taps cast copper alloy screwed down crutch or buttefly handle screwed both ends for iron pipe brass ferrrule of size 15mm bore all as specified and directed.
S&F in repairs stop cock cast copper alloy screwed down, high pressure, with crutch of butterfly handle screwed both ends to iron pipe of size 15mm, all as specified and directed.
S&F in repairs of Stack clamps for any bore of pipe out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends pof stays to wall or roof all as specified and directed.
S&F in repairs Health faucet brass chromium plated two way bib tap with connecting decorative pipe including all accessories required for fixing of 15 mm bore of pipe all as directed.
S&F in repairs 15mm Brass CP mixer tap for mixing " Hot or Cold" water screwed down for iron pipe all as directed (Make : Jaguar, CAT Part No FUS- 29273UPR)
S&F in repairs Elevated height raiser seat for EWC Commode Make : JE 06 Inches)
S&F in repairs grating square or rectangular 150mm dia of PTMT (minimum weight 100 gms, all as specified and directed.
S&F in repairs of chromium plated shower roses 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union, all as specified and directed.
S&F in repairs PVC connection both side brass unions internal for size 15mm dia and 450mm long all as specified and directed.
S&F in repairs angle cock 15mm bore, two way, chromium plated, fixed to GI or steel tubing incl fittings complete all as specified and directed. Make - Jaguar Model No ALI-85053 Angular Stop Cock with Wall Flange
S & F Wash basins, flat back, vitreous China , size 560x400mm including fixing on brackets and providing 32/40 mm dia PVC waste coupling, PVC connection 600mm long and waste pipe of 32mm dia all as specified and directed
S&F pillar taps in repairs 15mm bore dia, fancy type, cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered HOT or COLD with long screwed shanks and fly nuts screwed for iron pipe and fixed all as specified and directed.
Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc, all as specified and directed.
M & L for rendering 15mm thick on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement all as specified and directed.
M & L for rendering 15mm thick on fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement.
M&L rendering 10 mm thick in cement mortar 1:4 om fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement all as specified and directed.
Preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of primer all as specified and directed.
M&L for of preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer over 3mm thick Birla wall care putty finished even and smooth, all as speciified and directed
M&L for preparation of new plastered surface and for applying three coats of white wash on ceiling all as specified and directed.
M & L for preparation of old decorative surface of walls with steel wire brushes of smoke spots, moulds, efflorescent salts including filling of spots with POP and applying of two coat of cement base paint over a coat of primer all as specified and directed.
M & L for prepartation of old decorated surfaces by scraping down old decorative surface of walls with steel wire brushes of smoke spots, moulds, efflorescent salts and applying 3mm thick, Birla putty and making smooth surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer all as specified and directed.
M&L for old painted steel surface of any description , over 10cm in width or girth , not otherwise described for and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L painting to steel surfaces of any description over 10cm width or girth including preparation of new or untreated surfaces and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specifed and directed .
S&F Cast iron rainwater socketed pipes of 150mm dia, fixed with cement joints with ears , all as specified and directed. ( Note : Quoted rates shall be deemed of work to be carried out upto Roof top i.e 04th floor height with provn of scaffolding/ ladders / any hanging devices or other eqpts for work etc and saftey harnices and this Note is applicable for all items of Sch of wall related works)
S&F in repairs Cast Iron RWP Branch , single of 150mm dia all as specified .
S&F in repairs Cast iron RWP, Shoes of 150mm dia, all as specified.
S&F PVC (SWR) pipes 110 mm dia single sockets, in any length rubber ring joints, laid in trenches or in floor all as specified and directed.
S&F in repairs PVC (SWR) 110mm dia bends any radius all as specified and directed.
All as per descritpion of item No 82 above but PVC (SWR) pipes 160mm bore all as specified and directed
All as per descritpion of item No 83 above but PVC (SWR) 160mm dia bend all as specified and directed
S&F in repairs PVC (SWR) branch 110mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
S&F in repairs PVC (SWR) junction110mm bore single ( single t) equal or unequal all as specified and directed.
S&F in repairs (SWR) pipes 75 mm dia single sockets , in any length rubber ring joints, laid in trenches or in floor all as specified and directed.
S&F in repairs PVC (SWR) 75 mm dia bends any radius all as specified and directed.
S&F in repairs PVC (SWR) branch75 mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
S.R.M.K Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .