| Sl No | Description | Qty | Unit | SM ENTERPRISES L1 |
|---|---|---|---|---|
| 0.00CRE - RE - VALIDATION | ||||
| 1.00CEILING SUSPENDED LAMINAR AIR FLOW UNIT (CLAF) - RE - VALIDATION | ||||
| 2.00Re-validation of Ceiling Suspended Laminar Air Flow Unit(s) (CLAF) already installed at site. Prior to testing, the contractor shall conduct a thorough visual inspection of the installed units for structural integrity, fastener tightness, suspension arrangement safety, filter housing seal condition, electrical wiring integrity, earthing continuity, blower condition, general cleanliness and the unit to be serviced where required. The units shall be powered up and checked for correct direction of rotation and absence of abnormal noise or vibration. Testing shall be carried out as per ISO 14644-3 / WHO GMP and other applicable guidelines. The testing programme shall minimum include: (1) Air velocity test. 2)Filter integrity test. (2) Non-viable particle count. (3) Monitoring of pressure differential. (4) Recovery test. (5) Air flow pattern test. (6) Stabilization time interval test (all mandatory validation test mentioned on HBL protocol shall be carried out as per requirement). Any deficiencies or non-conformances identified during testing shall be reported and rectified before validation acceptance. Validation documentation (IQ review/as-found and OQ as applicable) shall be prepared and submitted as per HBL format. | ||||
| 3.00AR Block | ||||
| 4.00 | Size (Overall) in mm: 2590 x 1340 x 650 | 1 | Nos | 5,000 ₹5,000 Lowest |
| 5.00 | Size (Overall) in mm: 2590 x 1250 x 650 | 1 | Nos | 5,000 ₹5,000 Lowest |
| 6.00 | Size (Overall) in mm: 1807 x 1340 x 650 | 1 | Nos | 5,000 ₹5,000 Lowest |
| 7.00 | Size (Overall) in mm: 1807 x 1340 x 650 | 1 | Nos | 5,000 ₹5,000 Lowest |
| 8.00 | Size (Overall) in mm: 1654 x 1340 x 475 | 1 | Nos | 5,000 ₹5,000 Lowest |
| 9.00QA/QC Block | ||||
Tender Value
₹4.2 L
EMD Value
₹10,600
Closing Date
27 Jun 2026, 3:00 pmClosed
Deputy General Manager Proc.
HLL BIOTECH LIMITED, Integrated vaccine complex, Survey no 192 195, Meleripakkam village, Chengalpattu PIN 603003
Revalidation, Testing Certification Of Cleanroom Equipment for ARB, QC, BVF WH Blocks at IVC Facility at HLL Biotech Limited, Chengalpattu, Tamil Nadu.
2026_HBL_280402_1
HBL/CRPEQP_II/IVC/CPT/26-27, Dt. 10.06.2026
Open Tender
Miscellaneous Works
Item Rate
25 days
Chengalapattu
Please refer Tender documents.
18 documents required · 18 mandatory
₹1,770
Yes
HLL Biotech Limited
₹10,600
Yes
ONLINE
24 Aug 2026
10 Jun 2026
29 Jun 2026
10 Jun 2026
27 Jun 2026
11 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | CRE - RE - VALIDATION | - | - | - | - |
| 1 | CEILING SUSPENDED LAMINAR AIR FLOW UNIT (CLAF) - RE - VALIDATION | - | - | - | - |
| 2 | Re-validation of Ceiling Suspended Laminar Air Flow Unit(s) (CLAF) already installed at site. Prior to testing, the contractor shall conduct a thorough visual inspection of the installed units for structural integrity, fastener tightness, suspension arrangement safety, filter housing seal condition, electrical wiring integrity, earthing continuity, blower condition, general cleanliness and the unit to be serviced where required. The units shall be powered up and checked for correct direction of rotation and absence of abnormal noise or vibration. Testing shall be carried out as per ISO 14644-3 / WHO GMP and other applicable guidelines. The testing programme shall minimum include: (1) Air velocity test. 2)Filter integrity test. (2) Non-viable particle count. (3) Monitoring of pressure differential. (4) Recovery test. (5) Air flow pattern test. (6) Stabilization time interval test (all mandatory validation test mentioned on HBL protocol shall be carried out as per requirement). Any deficiencies or non-conformances identified during testing shall be reported and rectified before validation acceptance. Validation documentation (IQ review/as-found and OQ as applicable) shall be prepared and submitted as per HBL format. | - | - | - | - |
| 3 | AR Block | - | - | - | - |
| 4 | Size (Overall) in mm: 2590 x 1340 x 650 | 1 | Nos | - | - |
| 5 | Size (Overall) in mm: 2590 x 1250 x 650 | 1 | Nos | - | - |
| 6 | Size (Overall) in mm: 1807 x 1340 x 650 | 1 | Nos | - | - |
| 7 | Size (Overall) in mm: 1807 x 1340 x 650 | 1 | Nos | - | - |
| 8 | Size (Overall) in mm: 1654 x 1340 x 475 | 1 | Nos | - | - |
| 9 | QA/QC Block | - | - | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.62 MB
TEDOCREII.pdf
Tender Documents • 0.61 MB
BOQ_327234.xls
BOQ • 0.35 MB
DATEEXTNCREII.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .