Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹43.6 L
EMD Value
₹87,154
Closing Date
14 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA
ADDITION ALTERATION OF BUILDING NO-56 FOR IMPLIMENTATION OF BASE REPAIR FACILITIES UNDER GE NAGROTA
2022_MES_500624_2
GEN-64/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE NAGROTA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NAGROTA
₹87,154
Yes
20 Feb 2022
27 Jan 2022
16 Feb 2022
27 Jan 2022
14 Feb 2022
31 Jan 2022
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness.
Excavating in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for foundation etc. and getting out in Sof t/ loose soil
M & L PCC 1:4:8 type D-2 (Using 40 mm grade aggregate) in foundation, filling and mass concrete
Use and waste of formwork for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces
Use and waste of formwork for sides of columns posts, struts,piers square or rectangular or polygonal rough finished surface of concrete all as specified.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in foundation, plinth beams,footings etc,.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in columns.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in floor or roof beams linital beams complete all as specified and directed
Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr as specified.
M & L TMT bar 10mm dia and over cut to length bend to shape required indd cranking bending spirally for column, hooking ends & binding with and incld mild steel wire (annealed) not less than 0.90mm dia or securing with chips as directed
M & L TMT bar but 5mm dia and over upto and including 10mm dia in stirrups, spacers and bindersincluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip as directed
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified.
M&L rendering 15 mm thick on external faces brick /concrete surfaces other than fair faces of wall in cement mortar 1:4 rendering is to be finished even and smooth (without using extra lime or cement all as specified and directed.
M & L preparation of new decorated surfaces of external walls and applying two coat of cement base paint over a coat of primer complete as specified and directed
M&L for rendering 15 mm thick in CM 1:6 on other than fair face of brick work/ stone wall surfaces finished even and smooth with out using extra cement all as specified.
Preparing new plastered surfaces of wall and applying two coats of oil bound distemper over 1 to 2 mm thick wall care putty over a coat of primer on walls etc all as specified .
Complete removal of existing treatment of old walls and applying two coats of oil bound distemper over 1 to 2 mm thick wall care putty over a coat of primer on walls etc all as specified .
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, gusset plates, or flat sections) including distance pieces, cleats etcFe 410 -W (GdeE- 250) qualityA complete all as specified.
M&L Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer all as specified and directed.
M & L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for glazed ceremic tiles 350x250x7 mm/450x300x7mm thick, as in dado, vertical surfaces set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 10 mm thick rendering in CM (1:4) complete all as specfied and directed.
M&L for 25mm thick PCC type BO 1:2:4 (12.5mm graded aggregate in flooring finishing rough to recieveing Top layer for flooring complete all as specified and directed.
Machine cut kota stone flooring 18-20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) (Each stone not less than 55 cms x 55 cms) over 25mm thick PCC (1:2:4) type B1 over 15mm thick screed bed in CM ( 1:4) as in floor finished rough and applying a coat of cement slurry @ 03 Kg/Sqm of surface complete all as pecified and directed.
Machine cut kota stone slab 18-20mm thick in skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) over 15 mm thick rendering in CM ( 1:4) including taking out of existing dado.
S&F vitrified ceramic tiles 10mm thick,(square/rectangular ) polished ,light shade area of each tiles not exceeding 0.36sqm, in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified.
M&L for screed bed or bedding layer of cement mortar 15mm thick in CM 1:6 for laying floor finish complete all as specified.
S&F vitrified ceramic tiles 10mm thick,(square/rectangular ) polished ,light shade area of each tiles not exceeding 0.36sqm, on vertical surface such as skritting etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade Skitting etc including 10mm thick rendering in CM 1:4 complete all as specified.
S&F Aluminium anodized snap grid (powder coated) frame work of grid size 605x605mm including hangers 6mm dia GI (upto 1200mm long) for false ceiling including notching and preparing holes, including aluminium cleat/corner pieces and GI 4mm dia suspenders with utterfly clips, wall angle of size 24 x 24mm, main runner (teee) of size 24 x 38mm, cross tee of size 24 x 28mm, (No of suspenders shall be decided by the GE as per actual size requirement) including 4mm thick non asbestos fibre cement plain builiding boards fixed to aluminum snap grid and providing two coats of white wash including preparation of surfaces including dismantling wall and ceiling board, any thickness includiing cover fillets if any all as specified and directed.
S&F Aluminum frame of natural anodized aluminum min 1.5mm thick of size 101.60x44.45mm including necessary jointing cleats and fixing frame to wall/floor complete in all respect as per manufacture instructions and incluiding making good disturbed surfaces complete all as specified and directed by Engr-in-charge (Aluminum frame will be provided with/without groves & to accommodate glass, grill etc as per site requirement).
S&F aluminum doors shutter air tight with natural anodized party glazed with and including 5mm thick tinted glass and party panel with and including 12mm thick prelaminated particle board (All aluminum member Top, Bottom, Vertical & Middle of shutter made of size 82.55 x 44.45 x 1.50mm thick (Minimum) including necessary cleats glazing clips, 5mm thick tinted glass, rubber packing with anodized aluminium beading/glazing clip size 19.00 x 17.30 x 0.70mm wt 0.097 Kg/RM of both side and fixing aluuminum fitting ie SS hinges 100mm three numbers, handles 200mm long two number, tower bolts 150mm two numbers and mortize lock with 06 lever one number in each leaf. All aluminum member and fitting should be ISI marked complete in all respect as per manufacture instructions and as directed by Engr-in-Charge.
S&F aluminum window fixed type with three track (min 1.5mm thick) with three shutters made of 18x40x1.25mm section (one for wire mesh and two for tinted glass) with rubber gasket beading and locking arrangement etc complete all as specified incl 5.5mm thick tinted glass and GI wire mesh of size .56mm dia of wire and 1.40mm aperture incluiding making good disturbed surfaces complete all as specfied and directed.
M & L for PCC 1:2:4 type B-1 as in benching coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas rails cills, bed blocks etc.
M&L for 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and dirceted.
M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified.
S&F for 1000 ltrs capcity Rotational moulded polythene water storage tanks (cylindered vertical closed top ) hoisted and fixed in position all as spd in SSR Part –I, complete all as specified and dirceted. Make :-Vectus or Supreme Note:- Samples have been kept in GE office.Contractors shall quote their rate accordingly.
S&F for 2000 ltrs capcity Rotational moulded polythene water storage tanks (cylindered vertical closed top ) hoisted and fixed in position all as spd in SSR Part –I, complete all as specified and dirceted. Make :-Vectus or Supreme Note:- Samples have been kept in GE office.Contractors shall quote their rate accordingly.
Cutting chases,pinning for tubing and making good to facing where required and pointing in cement mortar 1;3 ,cutting exc 10cm but n.exc 20cm girth all as specified and as directed by Engineer-in -Charge.
Supply and fixing in repair ball Valve high pressure of PTMT with PVC float and fly nut complete screwed for iron pipe or brass ferrule and fixed with 20mm dia complete all as specified and directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, completeall as specified and directed by Engr-in-charge
S&F aluminum window fixed type with rubber gasket beading and locking arrangement etc complete all as specified incl 10mm thick toughtened glass incluiding complete all as specfied and directed.
M&L for PCC 1:2:4 type B 1 using (20 mm graded aggregate) as in blocks for hold fasts, benching, coping apex stones, bed plates and the like including weathering slightly rounded or chamfered angles and throating all as specified and direct. Note: Form work required for these items included in the unit rate of this item.
M & L for cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) 100mm thick as in sub base to receiving the top layers/ finish complete all as specified.
M&L Cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) 100mm thick as in flooring finshed cement concrete surface even and smooth without using extra cement all as specified.
S&F vitrified pavit ceramic tiles 10mm thick,(square/rectangular ) polished ,light shade area of each tiles not exceeding 0.36sqm, in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified. Note:- Samples have been kept in GE office.Contractors shall quote their rate accordingly.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5 m above the starting point
Returing filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick.
Cement concrete 1:4:8 type D-2 (using 40mm graded agg.) as in concrete bed to drain pipe including packing under and hunching against the sides of pipe after they are laid and tested for 150mm dia SGSW pipe.
SGSW drain pipes laid in trenches 150mm dia and jointed as specified.
Excavating in post holes (orsimilar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft soil complete.
M&L structural steel for staging of (OHT) frameed in angle/channel and Flat bracing including base piece Fe 410 -W (GdeE- 250) qualityA complete all as specified.
M&L for Reinforced cement concrete 1:2:4 (nominal mix) as in slabs supported on walls, beams and coloumns and the like slab laid in slops all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified.
M&L 18 to 20 mm thick Granite black (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over 15 mm thick CM 1:4 as directed by Engr-in-charge.
M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified.
S & F in repair bib taps 15mm bore cast copper alloy chromonium plated with, screwed down, screwed for iron pipe.
M&L nahani trap 100mm dia with grating including joining to waste pipe with run lead jointing and setting/fixed in cement concrete type B-1 (1:2:4) fixed in repair complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) PVC casing caping in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following;- (a) One light point controlled by one switch 5 Amp.
(b) One ceiling fan/exhaust fan point controlled by one switch 5Amp
(c) One socket out let 5Amp controlled by one switch on same board.
(d) One socket out let 5 Amp controlled by one switch on independent board.
All as per item No 58 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board.
All as per item No 58 here in before but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4 sqmm cable as earth continuity conductor for controlled by two pin and earth plug and socket complete with one single pole MCB 20 amp 240V
S&F switch piano flush type 5 Amps single pole one way complete,
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete.
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete.
S&F of ceiling rose surface type 65mm x 50mm 2 to 3 terminal complete .
Supply and fixing swing type wall mounting fan 450 mm sweep single phase AC 230/240V complete for wall mounting incl grouting, holding down bolts, nuts, and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan. Make per model No Airboll Hi-speed of Havells and equivalent in Bajaj / CG.
Supply & fixing heavy duty Exhaust fan 450 mm sweep single phase AC 230/240V complete with louvers Make : Havells/ Bajaj/CG
S&F Single pole & neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp 240V
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete.
S&F MCB DP 63 Amps 10 KA 230 volts "C" series complete
S&F MCB single pole 6 to 30 Amps 10 KA 230 volts "C" series complete
M&L Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V 50 Hz. Cat part no.112181 BLRB-DB 118 of Bajaj or equivalent in approved make.
S&F white powder coated CRCA housing with LEDs 36W, 230 V, 50 Hz Surface mounting LED 2 feet x 2 feet luminaries, Sweamless front frame with flat white hight transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat part no.BZSSQL 36W WH of Bajaj or equivalent in approved make.
S&F high pressure die-cast aluminium with black opening and separate compartment for maintaing driver with IP 66 with LEDs flood light 250W, 230 V, 50 Hz Surface mounting complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat part no.HPLLEDFL25060D of HPL or equivalent in approved make.
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link TPN 4 way suitable for MCCBas incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar including 125 A MCCB as incomer 16 KA complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site incl taking out of exsing UNSV DB with MCBs.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core
Supply and fixing wall mounted busbar chamber 415V, 3 Phase 4 wire, 50Hz AC supply system fabricated from stainless steel with 3mm thick for outer cell TPN aluminium busbar of cap 100 Amp 4 pole 8 ways complete all as specified and directed by Engr-in-Charge. Make : Havells cat part No : IHBC010008 or equivalent in approved make.
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sq mm as earth continuity conductor connected to commen earth and earth dolly complete incl taking out existing UNSV service connections.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete.
ASHOKA ENGINEERS AND BUILDERS
R.K. Works
U K Engineering Works
SUNIL AND CO
Nitika electricals and engineers works
Mahajan Auto Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .