| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹48.4 L+₹90,064 (1.90%)Rejected-Finance 37 4TH CROSS ASHWATHNAGAR SANJYANAGAR POST BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹50.8 L+₹3.4 L (7.10%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
21 Oct 2024, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF PUMP MOTOR STARTERS DOZING SYSTEM BOREWELLS SWIMMING POOLS COMPRESSORS AND OTHER CONNECTED ITEMS AT AFS JALAHALLI
2024_MES_676173_1
8908/E8
Open Tender
Electrical and Maintenance Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹1 L
21 Nov 2024
23 Sept 2024
23 Oct 2024
23 Sept 2024
21 Oct 2024
7 Oct 2024
23 Sept 2024 - 30 Sept 2024
Amount
M&L for taking down defective centrifugal pump set 100 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at same location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The contactor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contactor. (e) Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 100 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
M&L for taking down defective centrifugal pump set 50/60 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at same location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The contactor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contactor. (e) Please note that this penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 60 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply and fix in replacement of mechanical flexible UT tyre rubber coupling suitable for 60 HP centrifugal pump set with cast iron flange, natural rubber coupler, mild steel clamping ring, high tensile strength Grade suitable size of Hex bolts, including aligning motor - centrifugal pump with a tolerance of +- 4mm, testing complete all as specified and directed.
M&L for rewinding of squirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 100HP motor capacity.
M&L for suitable size of gland packing for 100 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply & fix in replacement of 3 Pole power contactor AC 415 V 160 Amps , AC3 ( inductive load ) type with Aux contact 2 NO + 2 NC 50 Hz Model No. as per existing frame suitable for 100 HP Pump sets complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 100 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be include in quoted rate.
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay 105 to 156 A for 100 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
M&L for rewinding of squirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 50/60 HP motor capacity.
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 60 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
M&L for suitable size of gland packing for 60 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply & fix in replacement of 3 Pole power contactor AC 415 V AC3 ( inductive load ) type 100 Amps, AC3 type 2 NO + 2 NC 50 Hz Model No. as per existing frame suitable for 60 HP Pump sets complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay 75 to 110 A for 60 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
Supply & fix in replacement Single phase preventer for motor in the existing panel board with new one at water supply installations complete all as specified and as directed.
Supply & fix in replacement Star Delta timer 0-30/60 sec complete all as specified and as directed.
Supply and fix as in repair 4 Pole MCCB ,415 volts,fixed type ,160 Amp, 50 Hz, with rupturing capacity 25 KA in the existing pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand
M&L for taking down defective centrifugal pump set 40 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The contactor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case of services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contactor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Taking down defective centrifugal pump set 25 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The contactor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contactor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only split casing gaskets suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of squirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 40 HP motor capacity.
M&L for suitable size of gland packing for 40 HP pump set as per manufacturer's design complete all as specified and as directed.
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 40 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay suitable for 40 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
Supply & fix in replacement of 3 Pole power contactor AC 415 V AC3 ( inductive load ) type 40 Amps with add on aux contact 2 NO + 2 NC 50 Hz Model No. as per existing frame suitable for 25 HP Pump set complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
M&L for rewinding of squirrel cage induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 25 HP motor capacity.
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed the 25 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay 30 to 43 A for 20/25 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
M&L for suitable size of gland packing for 25 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply and fix as in repair 4 Pole MCCB ,415 volts,fixed type ,125 Amp, 50 Hz, with rupturing capacity 25 KA in the existing pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand
Taking down and relaying of existing DI water pipe lines of size 300 mm bore but of any type including all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing DI water pipe lines of size 200 mm bore but of any type includings all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 300 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grase etc complete all as specified and directed. Note :- DI fitting/special will be measured and paid separately. Note: Excavation & earthwork shall be measured & paid seperately
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 200 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grase etc complete all as specified and directed. Note :- (i) DI fitting/special will be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid seperately
Supply and fixing in replacement Sluice valve of size 300 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Material and Labour for dismantling the brass spindle from 300 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of 300 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
Material & Labour as in repair for Construction of Valve pit having inner dimensions 1200 mm x 1200 mm x 1200 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class 'B' old size bricks built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.
Supply and fixing in replacement Sluice valve of size 200 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Material and Labour for dismantling the brass spindle from 200 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of 200 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
S&F in replacement foot valve (confirming to IS-4038) cast iron of size 200 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed.
Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 200 mm ISI marked, CI body suitable for 200 mm dia pipe line complete all specified and directed
Supply and fix replacement of U/S leather packing suitable for foot valve 150 to 200 mm dia, suction pipe flanged connected to pumpsets including replacement of nuts and bolts etc all as specified and directed
Clearing the bushes trunk girth not exceeding 10 .00 cm and area around valve chambers upto 1.0 mtrs and depositing at a distance not exceeding 50 mtrs from starting point complete all as specified and directed
Demolition of Brickwork or precast concrete block walling including wall quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and concrete articles built in cement mortar complete all as specified or directed.
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in cement mortor 1 : 4, complete, in walls all as specified and directed.
Supply and fix as in repair TPN MCB ,415 volts,fixed type ,63 Amp, 50 Hz, with rupturing capacity 10 KA in the existing pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 300 mm dia, by dewatering the leakage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure any leakage with pressure test complete all as specified and directed , Note : Pipes and mechanical collar are measured and paid seperately
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 300 mm bore complete all as specified and as directed.
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 200 mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure any leakage with pressure test complete all as specified and as directed. Note : Pipes and mechanical collar are measured and paid seperately
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 200 mm bore complete all as specified and as directed.
Over hauling and repair to Chemical Dosing Pump Granual based chloronome plants Range pump house by cleaning the FRP 150 Ltrs Tank, and cleaning of filters and NRV , checking and cleaning the delivery pipe line for chocking , cleaning of chlorination plant and maintainig properly including checking the level of oil in the gauge and topping up as and when required, checking the glands and maintain the plant in all respect and replacement of minor spare for smooth functioning of Chlorination Plant all as directed by Engineer in charge. Note:- The unit rate quoted shall be deemed to include for the cost of replacement of minor spares such as 'O' rings , nut/screws,washers,bolt, cleaning waste , tools for routine day to day maintenance and necessary servicing to keep the plants in running condition on all days including Sunday and holidays, Replacement of other major spares shall be measured and paid for separately under respective item of BOQ
All as per item No 87 but at E & ITI OH Tank complete all as specified and directed.
All as per item No 87 but at Double Tank complete all as specified and directed.
All as per item No 87 but at ETI OH Tank complete all as specified and directed.
Supply only O-tolodine chlorine solution in packing of 200ml bottle for testine of chlorine content in water
Supply only Chlorine dosing piston pump unit complete
Supply only Rubber ring for mixing chamber
Supply only PVC NRV set with glass ball for suction and delivery adopter 20 mm dia
Supply only Teflon gland square type 3 mm for smooth functioning of Chlorination plant
Supply only PVC diaphram valve 25 mm dia heavy duty
Supply only Agitator mixing assembly with motor
Supply only Chlorine test kit with coloured sample Complete with all testing fitments and OT - solution in Rexene finished box Complete all as specified and as directed
Supply of calcium based high strength chlorination chemical for water in granular form chlorine concentration level having 65%-70% chlorine content packed in 45 Kg capacity in factory sealed HDPE Container superior quality suitable for treatment of drinking water complete all as specified and directed. Note:The material should be delivered at watersupply installation as per direction of AGE E/M as & when required during the contract period.
Taking down defective centrifugal/Monoblock pump set 10 HP to 15 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The contactor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contactor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only split casing gaskets suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 10 HP to 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Taking down defective centrifugal /Monoblock pump set upto 4 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The contactor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contactor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only coupling bolt with nuts suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Ball bearing suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only split casing gaskets suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable forupto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for upto 4 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for the up to 15 HP motor capacity.
M&L for suitable size of gland packing for 10 HP to 15 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay 15 to 21 A for 15/10 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 10 HP to 15 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
Supply & fix in replacement of 3 Pole power contactor AC 415 V AC3 ( inductive load ) type 25 Amps with add on aux contact 2 NO + 2 NC 50 Hz Model No. as per existing frame suitable for 15/10 HP Pump sets complete all as specified and as directed. Make : L & T / Indo Asian /Schneider
M&L for rewinding of electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation /base, cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation/ base of sunction sweeper by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load complete all as specified and directed for 4 HP motor capacity.
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the upto 5 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
Supply and Fixing as in replacement MCCB, 4 poles 415 Volts, 100 Amps, 16 KA, 50 Hz, AC, adjustable thermal and magnetic type in the existing pump starter panel including connecting up incoming/out going cable with suitable lugs and testing complete all as specified and as directed. Make : Legrand/Indo asian/L&T
M & L for Fixing in repairs Water Level Indicator consisting of float ball, nylon rope, Scale for water level indication made out of MS frame with pulley and indicating pointer for OHT at different places all as specified and directed .
Supply and fixing in repair of 3 phase star delta pump starter suitable for 25 HP centrifugal pump with over load relay of suitable current rating,timer relay ,single phase preventor fixing in existing enclosure including all connected accessories complete all as specified and directed Make : L&T/Indoasian/Schenider/Havells
Taking down and relaying of existing DI water pipe lines of size 150 mm bore but of any type includings all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing DI water pipe lines of size 100/80 mm bore but of any type includings all fittings after removal of scaling, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grase etc complete all as specified and directed. Note :- (i) DI fitting/special will be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid seperately
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 100 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grase etc complete all as specified and directed. Note :- (i) DI fitting/special will be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid seperately
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 80 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grase etc complete all as specified and directed. Note :- (ii) DI fitting/special will be measured and paid separately. (i) Excavation & earthwork shall be measured & paid seperately
M & L for DI specials and fittings as per IS for spigot and socketed pipes or flanged pipe for water mains branch lines such as bends(any type radious and angle ) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pices,single branch,Y juntion, double branch, cross, including connecting pieces one end flanged and other socket or spigot and bell mouth pices suitable for rubber joint,tyton joint up to 150 mm bore and conforming to IS-9523: 2000 complete all as specified and directed
Supply and fixing in replacement Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Material and Labour for dismantling the brass spindle from 150 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of 150 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 150 mm ISI marked, CI body suitable for 150 mm dia pipe line complete all specified and directed
S&F in replacement foot valve (confirming to IS-4038) cast iron of size 150 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed.
Material and Labour for Cutting DI pipes in position for insertion of new tees and socket of size 150 mm dia Complete all as specified and as directed.
Supply and fixing in replacement butterfly valve (confirming to IS-13095) of size 150 mm dia Cl body, ISI marked with IS-13095 having double door convex shape to prevent eddies and reaches head loss, neoprene rubber sealing and fitted complete all specified and directed
Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Material and Labour for dismantling the brass spindle from 100 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Supply and fix replacement of leather packing suitable for foot valve 80 to 100 mm dia, suction pipe flanged connected to pumpsets including replacement of nuts and bolts etc all as specified and directed
Material and Labour for gland packing in leaking Sluice Valves of 100 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 100 mm ISI marked, CI body suitable for 100 mm dia pipe line complete all specified and directed
S&F in replacement foot valve (confirming to IS-4038) cast iron of size 100 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed.
Supply and fixing in replacement Sluice valve of size 80mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.
Material and Labour for dismantling the brass spindle from 80 mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS/bronze, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of 80 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
S&F in replacement foot valve (confirming to IS-4038) cast iron of size 80 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed.
Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 80 mm ISI marked, CI body suitable for 80 mm dia pipe line complete all specified and directed
Supply and fixing in replacement Non return valve (confirming to IS-5312) (NRV) of size 65 mm ISI marked, CI body suitable for 65 mm dia pipe line complete all specified and directed
Material and Labour for Plain Cement Concrete (1:2:4), type B1 (using 20 mm graded crushed stone aggregate) as in Coping, bands benching etc including finishing the concrete surfaces even and smooth without using extra cement including necessary form work Complete all as specified and directed.
Material & Labour as in repair for Construction of Valve pit having inner dimensions 900 mm x 900 mm x 900 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class B old size built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber Covers will be measured and paid separately under relevant item of this schedule.
Supply and fixing Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, hinges and handles etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 for valve pit chamber, raising main support and motor foundation supports etc.complete all specified and directed.
Material and labour for Fabricate supply and fix valve chamber covers made out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted cover all as directed.
Material and labour for Painting with two coats of synthetic enamel paint over coat of zink chrome on surfaces of any description, over 10cm in width or girth,not otherwise described complete all specified and directed.
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 150 mm dia, by dewatering the lekage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure any leakage with pressure test complete all as specified and as directed. Note : Pipes and mechanical collar are measured and paid seperately
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 150 mm bore complete all as specified and as directed.
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 100 mm dia, by dewatering the leakage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure any leakage with pressure test complete all as specified and as directed. Note : Pipes and mechanical collar are measured and paid seperately
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 100 mm bore complete all as specified and as directed.
Supply and fixing in replacement of Air Release Valve of size 40 mm dia Cl body, ISI marked of IS 14845 of 1.6 PN including with fixing arrangement of existing 150 mm dia DI pipe line with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.
M & L for Fixing in repairs Water Level Indicator consisting of float ball, nylon rope, Scale for water level indication made out of MS frame with pulley and indicating pointer for UG sump at different places all as specified and directed .
Supply and fix as in repair TPN MCB ,415 volts,fixed type ,40 Amp, 50 Hz, with rupturing capacity 10 KA in the existing pump starter panel including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make: Indoasian/L&T/ Legrand
M&L for dewatering of Swimming Pool of size 50m x 25m (Olympic size pool ), Cleaning of Swimming pool bed,vertical walls complete with high pressure water jet to remove all masses, algae and dirt and removal of dirty water with sludge using non clog sludge machine and disposal of the same to a safe distance & applying of anti bacterial sterlization spray to walls, floors and applying muriatic acid, caustic soda or any other cleaning agent without damaging the existing tiles. Finally washing total surfaces with fresh water and make ready for fill up and ceilings all as directed. Note: (a) The Rate quoted by the contactor is deemed to include labours,tools and acessories and provision stickering of date of cleaning on the existing board letter / figures White or Black colour and size as per existing font. (Date of Cleaned in formate of (DD/MM/YY) Note : chemicals used for cleaning/PH level stablizer/anti Baterial/anti algae controller are supplied under relevant items
All as per Sl Item No.168 here-in-before but Diving Pool of size 20 x 20 Meter complete all as specified and as directed.
All as per Sl Item No 168 here-in-before but Balancing Tank of capacity 1,00,000 Gallon complete all as specified and as directed.
Supply only swimming pool grade Copper Sulphate crystal of superior quality including stocking/ Handling and shifting complete all as specified and directed.
Supply only Soda ash free from impurity class I suitable for swimming pools and adding/mixing as per direction of Engr-in-Charge to maintain water quality including stocking/ Handling and shifting complete all as specified and directed.
Supply only swimming pool grade calcium based (Sodium Hypochloride) for water disinfectant as liquid form in sealed container having, chlorine concentration level not less than 12% and adding/mixing complete all as specified and as directed.
Supply only Swimming pool grade Hydro Chloric Acid (HCL) for regulating PH value of the pool complete all as specified and as directed.
Supply only non ferrous Alum powder/crystal free from impurity class I suitable for swimming pools and adding/mixing as per direction of Engr-in-Charge to maintain water quality including stocking/ Handling and shifting complete all as specified and directed.
Supply only Algae control gel/liquid free from impurity class I suitable for swimming pools and adding/mixing as per direction of Engr-in-Charge to maintain water quality including stocking/ Handling and shifting complete all as specified and directed.
Supply only chemically non reactive/lab quality Plastic mug 1 ltrs capacity complete all as specified and as directed.
Supply and fix in replacement of chemically non reactive/Lab quality Plastic bucket 35 ltrs capacity complete all as specified and as directed.
Supply and fix in replacement of nylon brush (soft quality) with wooden/HDPE base of size 3' feet long, 2.5" (Inch) wide localy available best quality, suitable for fix with suction sweeper.complete all as specified and as directed.
Supply and fix in replacement of nylon brush with HDPE base of size >18" Inch wide and handle > 20 feet long wide localy available best quality for cleaning walls of swimming pool complete all as specified and as directed.
Supply and fix in replacement of flexible pipe from suction sweeper pumps and Supply & fix PVC flexble hose pipe 50mm OD including necessary jubilee clamps complete all as specified and as directed.
Supply and fix in replacement of nylon rope 25mm dia for suction sweeper ( as per sample) complete all as specified and as directed.
Material and labour for opening the pressure filter vessel located in swimming pool of dia 2.8 Meter and height 2.6 meter for the following works:- (a) Opening the man hole cover and taking out entire filter media ie, existing stone aggregate , sand, quartz , slugde, algae etc (b) Cleaning of entire surfaces of sides , top and bottom of vessel by applying hydrochloric acid and thorough rinsing and make the vessel fit for re-filling the filter media. (c) Applying one coat of approved anti corrosive paint to entire internal surfaces of pressure filter including preparation of surfaces. (d) Re-fill the filter media with approved material of stone aggregate, river sand and white quartz in layers and properly packed upto existing level. All the material shall be rinsed thoroughly by using hydochloric solution and maintain the PH value at the range of 3 to 5. (e) Applying two coat of synthetic ename paint to external surface of pressure filter vessel preparation of surface etc and all as directed.
Supply and fix in replacement single phase 240V 50Hz DOL starter with OLR relay suitable for upto 4 HP monoblock pump sets inculding proper termination,testing and all connected acessories all as are specified and directed.
Material and labour for Making arrangement to flush out the existing pipe line of any type 110 to 150mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Material and labour for Making arrangement to flush out the existing pipe line of any type 160 to 200 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 185 to 186 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in quoted rate. (ii) Excavation and earth work required will be measured and paid seperately. (iii) The flushing out will be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This will be inclusive in quoted rate.
Material and labour for removing the submersible pump set of capacity up to 7.5/15 HP including pipes and submersible cables complete from the exisiting bore well of depth up to 200 mtr by any suitable method i.e either manual.vehicle mounted motorized system and disconnecting the pump motor to locate the faults in presence of Engr-in-Charge, transporting to Wksp and carry out repairs, reassembling, lowering to bore well after repairs, testing and commissioning complete all as specified and directed
M&L for taking out, dismantling pump and motor of submersible pump set of capacity upto 7.5/15 HP to carry out repairs and replacements , duly rewinding and replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing and inserting in borewell after repair complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below as supply only. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The contactor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contactor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only GM Bush suitable for 15 HP submersible pump set as per manufacturer's design complete all as specified and as directed.
Supply only SS coupling bearing suitable for 15 HP submersible pump set as per manufacturer's design complete all as specified and as directed.
Supply only sleeve MS key for impeller suitable for 15 HP submersible pump set as per manufacturer's design complete all as specified and as directed.
Supply only Sand Guard suitable for 15 HP submersible pump set as per manufacturer's design complete all as specified and as directed.
Supply only oil seal thrust bearing suitable for 15 HP submersible pump set as per manufacturer's design complete all as specified and as directed.
M & L for servicing of submersible starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 7.5 HP /15 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
S & F in repair Over load Relay range of (1.6 -2.5 Amps ) , max-10A (as per sample) for 1.5 HP starter (Dol/Star delta) complete all as directed.
S & F as in replacement ON load change over switch 4 pole 250 Amps in sheet metal enclosure complete all as specified and as directed. make :- Havells /L&T/Indo Asian
M & L for Over hauling and repair/replacement of unserviceable items of Portable RO unit of capacity 80 LPD by disconnecting all pipe lines , filters catridges, RO Membrane , motor, float valve and water storage tank, all filter catridges(Pre Activated carbon ,Post Activated carbon, inline sedimant , pre particle filter), motor carbon brushes, pressure pump diaphram, float valve,solenoid valve,12/24v SMPS power supply unit , damaged piles lines , bends ,tee , elbow, water flow restrictor including cleaning of water storage tanks and testing (TDS ), fixing of pre filters all respect and replacement of minor spare such as carbon brush ,tee ,elbow,pipe line,teflon tape,screws,nuts etc include in this quoted rate for smooth functioning of RO Plant complete all as specified and as directed. Note : Major spare parts are measured and paid seperately as supply only under relevant items of BOQ.
Supply only Reverse Osmosis membrane with clamps suitable for RO unit all as specified
Supply only Inline sediment filter with clamps suitable for RO unit all as specified
Supply only pre particle filter with food grade housing arrangement and with clamps suitable for RO unit all as specified
Supply only pre-activated carbon filter with clamps suitable for RO unit all as specified
Supply only Pressure pump 12/24v suitable for RO unit all as specified
Supply only float switch suitable for RO unit all as specified
Supply only Post-activated carbon filter with clamps suitable for RO unit all as specified
Supply only RO pressure Pump Diaphram Head unit suitable for RO unit all as specified
Supply only TDS,PH,Chlorine mesauring digital device all as specified
Supply only solenoid 12/24v suitable for RO unit all as specified
Supply only 12/24v SMPS suitable for RO unit all as specified
Supply and fixing as in repair pre filter housing element with suitable size of filter to protect RO including PVC pipe of required length and all connected items complete all as specified and directed.
S & F in repair Over load Relay range of (0.1 -1.5 Amps ) , max- 5A (as per sample) for 0.5 HP starter (Dol/Star delta) complete all as directed .
Excavation in trenches for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
M & L for Bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed.
Supply and fix for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc along with suitable fittings for cable protection .
Material and labour in repair for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD. (iv) Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items.
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thromoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 01 No. (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 25 KA - 02 Nos. (c) Soft starter of capacity of 60 HP pump including suitable adjustable OLR relay , along with single phase preventer (d) MCB SPN of 240 V of capacity 40 Amps 10 KA - 02 Nos. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The contactor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
M&L flat three core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 6 Sqm nominal area complete including taking out old unserviceable cable complete all as specified and directed. Make :- Havells/Polycab/Finolex/KEI
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 Amp by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contactor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contactor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contactor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contactor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contactor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contactor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contactor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contactor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit, complete including taking down, complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contactor shall submit load bearing capacity certificate from the manufacturer.
Material and labour as in repair for Earth pit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Squre Bar embeded in PCC (1:3:6) type C-1 using 20 mm graded stone agreegate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 250X300X 3 mm thick fixed on side of earth pit cover complete painting and writing over the plate ie. Type , Result, Date of measurement and pit number with Black background with white and complete all as specified and as directed.
Supply and fixing as in repair for aluminium earth continuity conductor or main earthing lead fixed to wall / roof top of for lightning arrester fixed to OHT other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, aluminium using porcelain clit/post insulators with screw / self dril GI screw with rubber washer , complete all as specified and directed.
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thromoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :- PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 01 No. (Incomer). (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 06 Nos. (d) MCB SPN of 240 V of capacity 40 Amps 10 KA - 02 Nos. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The contactor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). Note :- An amount of Rs 120264.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S J S PRAKASAM (BID ID -3146113)
M/S SRI BALAJI ENTERPRISES (BID ID -3145961)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .