Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 47 C MODEL TOWN EXTENSION LUDHIANA PB | LUDHIANA | PUNJAB | 141001 | ₹1.4 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC low |
| 2 | L2₹1.6 Cr+₹5.5 L (3.59%)Rejected-AOC 1111 PHASE 3 MODEL TOWN BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.6 Cr+₹5.5 L (3.59%) | L2 | Rejected-AOC high |
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
25 Oct 2024, 12:00 pmClosed
EXECUTIVE ENGINEER
Ropar Canal and Ground Water Division WRD Punjab
Estimate for Repair of Nangal Lift Scheme including Replacement of RCC Pipes,Repair of Pumps Complete in all respect, Repair of Building etc.
2024_WR_127554_2
33/22A/2024-25
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
180 days
village nikku nangal Teh. Sri Anandpur Sahib
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
₹2.7 L
Yes
Ropar Canal and Ground Water Division WRD Punjab
25 Nov 2024
11 Oct 2024
25 Oct 2024
11 Oct 2024
25 Oct 2024
11 Oct 2024
14 Oct 2024
Amount
Excavationmanuallyintrenchesforpipelines withstraight or opencutting instreetsand lanes inbuiltupareawherewidthof street / Lane fromwall towall is less than3meter including trimming and dressing sides levellingofbedsof trenchestocorrectgrade, cutting joint holes, refilling consolidation,watering, including thecost of dewateringof rainwater,diversionfor traffic, night signals. Providing & fixing caution boards,watching, fencing, etc. and removal of surplus soil from thesiteupto15meter distance complete in all respects a)Earth work upto 1.5 m. Depth b) All classes of soil except rocky
Excavation by mechanical means(JCB or Hydraulicexcavator) intrenchesforpipelines with straight or open cutting in streets or openarea including trimming anddressing sides levellingof bedsof trenches tocorrect grade, cutting joint holes, refilling consolidation,watering, including thecost of dewateringof rainwater,diversionfor traffic, night signals. providing & fixing caution boards, crossingover trenches foraccess to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the towninvolvingleadupto15metercompletein all respect. a) Earth work upto 1.5 m. Depth for i) All classes of soil except rocky
Excavation by mechanical means(JCB or Hydraulicexcavator) intrenchesforpipelines with straight or open cutting in streets or openarea including trimming anddressing sides levellingof bedsof trenches tocorrect grade, cutting joint holes, refilling consolidation,watering, including thecost of dewateringof rainwater,diversionfor traffic, night signals. providing & fixing caution boards, crossingover trenches foraccess to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the towninvolvingleadupto15metercompletein all respect. a) Earth work upto 1.5 m. Depth for ForOrdinarysoil havinggravel upto 40%
Dismantling concrete d) cement concrete plain 1:2:4 mix
Dismantling concrete b) cement concrete plain 1:4:8 or 1:5:10
Cement concrete 1:2:4 With stone ballast or shingle mixingbymechanicalmeansusingconcrete mixer volumetric type
Cement concrete 1:5:10 with stone ballast 40 mm gauge mixingbymechanicalmeansusingconcrete mixer volumetric type
Dismantling of Flexible Pavement (By mechanical means), dismentalling of flexible pavement thickness above 50 mm by mechanical means and disposal of dismantaled material up to a lead of 1000 meters , stacking serviceable and unserviceable material seprately as per technical clause 202 of MORT&H specification
Firstclassburntbrickworklaidincementsand mortar 1:4 in foundation and plinth
12.5 mm thick cement plaster 1:3
Reinforced cement concrete M-20 mechanically batchmixed using batch type concretemixer asper IS:1791andvibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Cold twisteddetormed (Ribbed/ Tor steel)Bars (Fe500gradeasper IS1786-2008) , forR.C.C works,wherenot includinginthecompleterateof RCC including bending and binding placing in position complete
Provind lowering precast concrete NP-2 plain end pipes and collar with reinforcement, in trenches to correct gradient and alighnment, cutting of reinforcement cement concrete plain end pipes. Stringing in trenches, joining end and fixing collar with cement mortor 1:2 as per IS 458:2003 into trenches for all depths and laying out same to correct alignment, gradients,levels etc. complete in all repects. RCC Pipe NP-2 500 mm I/D PIPE
Provind lowering precast concrete NP-2 plain end pipes and collar with reinforcement, in trenches to correct gradient and alighnment, cutting of reinforcement cement concrete plain end pipes. Stringing in trenches, joining end and fixing collar with cement mortor 1:2 as per IS 458:2003 into trenches for all depths and laying out same to correct alignment, gradients,levels etc. complete in all repects. RCC Pipe NP-2 400 mm i/d pipe
Provind lowering precast concrete NP-2 plain end pipes and collar with reinforcement, in trenches to correct gradient and alighnment, cutting of reinforcement cement concrete plain end pipes. Stringing in trenches, joining end and fixing collar with cement mortor 1:2 as per IS 458:2003 into trenches for all depths and laying out same to correct alignment, gradients,levels etc. complete in all repects. RCC Pipe NP-2 350 mm i/d pipe
Provind lowering precast concrete NP-2 plain end pipes and collar with reinforcement, in trenches to correct gradient and alighnment, cutting of reinforcement cement concrete plain end pipes. Stringing in trenches, joining end and fixing collar with cement mortor 1:2 as per IS 458:2003 into trenches for all depths and laying out same to correct alignment, gradients,levels etc. complete in all repects. RCC Pipe NP-2 300 mm i/d pipe
Provind lowering precast concrete NP-2 plain end pipes and collar with reinforcement, in trenches to correct gradient and alighnment, cutting of reinforcement cement concrete plain end pipes. Stringing in trenches, joining end and fixing collar with cement mortor 1:2 as per IS 458:2003 into trenches for all depths and laying out same to correct alignment, gradients,levels etc. complete in all repects. RCC Pipe NP-2 250 mm i/d pipe
Providing,fixingandjointingISIMarkedGun Metal peet valves (HeavyPattern)asper IS 778withhandwheels,onG.I.Pipelines laid inthegroundor insidebuildings includingall carriages complete 65mmi/dGunMetalpeetvalveheavy pattern
Providing,fixingandjointingISIMarkedGun Metal peet valves (HeavyPattern)asper IS 778withhandwheels,onG.I.Pipelines laid inthegroundor insidebuildings includingall carriages complete 80 mmi/dGunMetalpeetvalveheavy pattern
Providingand laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS1239) B Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. 65mm i/d
Providing & fixing double air valve ISI Markedasper IS-14845includingjointing all carriages complete. C.I Double air valve (Size 100mm)
Providing&fixingC.I/D.I Flangedend, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, includingjointing, testing&cost of Nut ,Bolt & insertion sheet, all carriage complete (with theapproval of Engineer in charge) Class PN-1. as per ISI 500mm i/d Sluice Valves flanged
Providing&fixingC.I/D.I Flangedend, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, includingjointing, testing&cost of Nut ,Bolt & insertion sheet, all carriage complete (with theapproval of Engineer in charge) Class PN-1.6 as per ISI 400mm i/d Sluice Valves flanged
Providing&fixingC.I/D.I Flangedend, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, includingjointing, testing&cost of Nut ,Bolt & insertion sheet, all carriage complete (with theapproval of Engineer in charge) Class PN-1.6 as per ISI 350 mm i/d Sluice Valves flanged
Providing&fixingC.I/D.I Flangedend, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, includingjointing, testing&cost of Nut ,Bolt & insertion sheet, all carriage complete (with theapproval of Engineer in charge) Class PN-1.6 as per ISI 300 mm i/d Sluice Valves flanged
Providing&fixingC.I/D.I Flangedend, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, includingjointing, testing&cost of Nut ,Bolt & insertion sheet, all carriage complete (with theapproval of Engineer in charge) Class PN-1.6 as per ISI 250mm i/d Sluice Valves flanged
P/F of Alfa valve 300 mm
P/F of Alfa valve 250 mm
Providing, laying, fixing, testing and commissioning of 'C' Class heavydutyMS Pipe conforming to Indian Standard IS : 1239/3589 includingfittings like tees, bends, sockets, elbows, flanges, tapers, nutsbolts, gaskets etc. in ground with anti corrosive treatment withwrappingcoating tape (4mm pypkotetape)asperIS:10221includingcost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 150 mm i/d
Providing, laying, fixing, testing and commissioning of 'C' Class heavydutyMS Pipe conforming to Indian Standard IS : 1239/3589 includingfittings like tees, bends, sockets, elbows, flanges, tapers, nutsbolts, gaskets etc. in ground with anti corrosive treatment withwrappingcoating tape (4mm pypkotetape)asperIS:10221includingcost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 200 mm i/d
Proving&fixingISIMarkedNon-returnvalves flanged end class PN-1.0 as per IS:5312/2004 inpipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used insteadof classPN- 1.0 , than5%will be paid extra b Class PN-1.0 as per ISI with gun metal flap 150mm i/d Non-return valve
Proving&fixingISIMarkedNon-returnvalves flanged end class PN-1.0 as per IS:5312/2004 inpipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used insteadof classPN- 1.0 , than5%will be paid extra b Class PN-1.0 as per ISI with gun metal flap 200 mm i/d Non-return valve
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Scraping Cement Plaster
Scraping White wash and colour wash
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below.
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Windows of area 3 sqm and below.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Wall paintingwith plastic emulsion paint of approvedbrandandmanufacturer togivean even shade (two or more coats)
Finishingwallswith acrylic smooth exterior paintof requiredshadewithtwoormorecoats applied @ 1.67 litre/10Sqm over and includingbasecoatofwaterproofingCement Paint applied @ 2.20 Kg/10 Sqm
Dismantlingcementconglomeratefloors25mm to 50mm thick including concrete base
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS :15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code- IS-2202-1) 1999 (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 4) 35mm thick
Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe 4kgf per sqm (ring fitted type-A) as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-incharge.
Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. c) Door and window frame of size113mmx60mmx with 35mm wide single rebate
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) ii) area above 0.50 sqm
Wire Gauge Red meranti wood Super (18 to 19 kg per cft. Approx.) door shutter without springs housed in chowkats a)35mm thick
Redmeranti Sinker quallity (20 to21kg per cft. Approx.) doors shutter windows shutter includinghinges,screwandcords etc. Complete fixed in position a Panelled, glazed or glazed and panelled. Ii 35 mm thick
Providing&Fixing glass panes with nails and putty or wooden strip complete in all respec b)Glazing area above 0.09 sqm ii)4mm thick or 10.78 Kg/ sqm
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m x 0.6m consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3
Providing and fixing in position Grating of approved make (to the approval of Engineer in charge)150 mm x 150 mm . For gully trap PVC Grating (P.T.M.T)
Excavation for Roadway (By Manual Means) ( a)Excavation for roadway in soil by manual means including carrying of cut earth to embankment site with all lead and lifts up to 50m as per technical clause 301 of MORT&H specifications
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code 15658 (2006)
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Corrugated G.I. Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. Limpot and bitumen washers complete excluding the cost of purling rafters and trusses
1.2meter highG.I. barbedwire fencingwith1.8 meterangle ironposts40x40x6mmplacedevery 3meterscentretocentre0.6meterbelowground level, every 15th post, end post, corner post suitably strutted and providedwith 9 horizontal linesandtwodiagonalsinterwovenwithhorizontal wires fixed with GI staples, turn buckles etc. including foundation concrete 1:2:4 of size 0.30x0.30x0.75mfor eachpost completeasper technical clause 808 of MORT&H specifications
Iron grated doors, including pintle hinges & arrangements.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
G.I. Sheet gutters 0.80mm thick semicircluar 15cmdiametre including fixingwithclamps and making connections with rain water pipes.
Ridges and valleys45 cmoverall, inplainG.I. Sheet0.80mmfixedwithgalvanzedironJ.andL. hooks10mmdiameter,G.I. Limpet andbitumen washers complete
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Ii) Size 550 mm x 400 mm x 815 mm
Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.a) C.P. brass towel Rails size 15mm dia 610mm long
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) a) size 600mmx450 mm
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. 1) C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C)C.P.brass 15mm Angle valve without flange
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. A)PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut
Providing and fixing jet spray with 2'-6" long PVC pipe.(a) With C.P. Brass nut
Providingand fixing inpositionSWRUPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.(d) for 75 mm outer dia) b)
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. A)75 mm x 75mm
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank (i) Triple Layer Tanks
Providing&fixinginpositiononterrace(atall floor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer-in-charge) complete in all respect For 500 l tank
Providing and fixing in position G.I. Tank Nippleof approvedmake (to theapproval of Engineer-in-charge) in PVCWater storage tanks complete in all respect G.I. tank nipple 20mm i/d
Providing and fixing in position automatic brass Ball Cock in tanks.B Brass Ball Cock with rod and Plastic Ball (ii) 20 mm i/d
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Providing, fixing and jointing ISI Marked Gun Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. (b) 20 mm i/d Gun Metal peet valve heavy pattern.
Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. a)110 mm o/d
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge),havingthermalstabilityforhot& cold water supply, including all CPVC plain&brass threaded fittings i/c fixing thepipewithclamps at 1.00mspacing includingjointingofpipes&fittings,with onestepCPVCsolventcementandtesting of pipes complete as per direction of Engineer-in-Charge SDR11CPVCpipes&fittings20mm o/d
INTERNAL- EXPOSED ON WALL : ProvidingandfixingChlorinatedPolyvinyl Chloride(CPVC)pipesasperIS15778(ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, includingallCPVCplain&brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointingof pipes&fittingswithonestep PVCsolvent cement andtestingofpipes completeasperdirectionofEngineer-in Charge SDR11CPVCpipes&fittings20mm o/d
EXTERNAL INTHEGROUND : Providing and fixingChlorinatedPolyvinylChloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge),havingthermalstabilityforhot& coldwatersupplyincludingallCPVCplain &brass threaded fittings. This includes jointingof pipes&fittingswithonestep CPVCsolvent cement,&testingof joints excludingcostofexcavationcompleteas per direction of Engineer-in-Charge. SDR11CPVCpipes&fittings20mm o/d
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete1:2:4benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspectionchambercoverandframe(Weight as per I.S.I specifications) painted with 3 coatsofblackbitumasticpaintconformingto I.S.I complete as per standard design a)Size450mmx450mminsidewithRCC 455mmx455mmcoverandframe light duty double seal
Constructing soakpit1.20x1.20x1.6mdeep, 230mmthick1:5brickworkhoneycombwith bricks of Ist Class filled with brickbats includingS.W. drainpipe100mmDiametre and1.20m longcompleteasper standard design
Providingand fixing inpositionsingel socket SWRUPVCsoilwasteorantisyphonagepipes asper IS13592ofE.D.Cmanufactureor of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A d)75mmo/dsinglesocket SWRUPVC pipe lines laid complete
Providingand fixing inpositionsingel socket SWRUPVCsoilwasteorantisyphonagepipes asper IS13592ofE.D.Cmanufactureor of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A d)100 mmo/dsinglesocket SWRUPVC pipe lines laid complete
Providingand fixing inposition15mmC.P. Pillarcock foamflow ofapprovedmake(to the approval of Engineer-in-charge)
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½"deepfor wallsandCI3"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface):aWiring fan point (Without fan box)
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½"deepfor wallsandCI3"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface):Wiring light point
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½"deepfor wallsandCI3"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface):Wiring 6Amp. wall socket point
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½"deepfor wallsandCI3"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface):Wiring 16/20Amp. power plug control point
RECESSEDPVCCONDUITPIPEWIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½"deepfor wallsandCI3"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface):Wiring light point with double control switches.
DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal DoubleDoorDistributionBoards IP43 IK09metal door (dustprotected) asper IS8623-1&3, IEC61439-1&3suitable for flush mounting with fully insulated copperbusbars, shroudedneutral bars, earthbars,cementspillprotector,color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label andof requiredno. ofways formounting miniaturecircuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/RCCB's/RCBO'sasincomerand SPMCB's asoutgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer andSPMCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc a) SP&NDoubleDoorDistributionBoard4way each
Erectionof Ceiling/ Cabin/ Exhaust fan having connectionwith PVC insulated PVCsheathed two single core copper conductor (FR) cable 0.75sq.mm complete a) Erection of Ceiling fan
ErectionofExhaust fanwith louver shutter on the wall/ window grill
Erectionof light fixturesonwall/ceiling having connectionwith PVC insulated PVCsheathed two single core copper conductor (FR) cable 0.75sq.mm complete: Erection of 1X20/28/36/40W Box Type (LED/ Fluorescent) light fixture
MINIATURE CIRCUIT BREAKERS SupplyanderectionofMiniatureCircuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacityof 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existingMCBdistributionboardasper PWDGeneral Specifications including connections with suitable size of thimbles/lugs: a)MCB Single Pole 6-32amp. (10kA, Curve-C)
MINIATURE CIRCUIT BREAKERS SupplyanderectionofMiniatureCircuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacityof 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existingMCBdistributionboardasper PWDGeneral Specifications including connections with suitable size of thimbles/lugs:b )MCBSinglePole50,63amp. (10kA,Curve C)
Supply & erection of PVCCasing 'n' Capping (Double Lock) ISImarked for wiringpurposesincludingcostofbends (L), (U), (T) & inspection boxes etc., where necessary including other petty material a) PVC Casing 'n' Capping Size 20mm x 12mm
Supply&erectionofPVCConduitPipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other pettymaterials etc.,asperPWDGeneral Specifications ii)HeavyGaugePVCConduitPipe25mmdia. (On Surface
SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: a Overall size 1sq.mm (Un-sheathed)
SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: b Overall size 1.5sq.mm (Un-sheathed)
SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: c) Overall size 2.5sq.mm (Un-sheathed)
SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: c) Overall size 4 sq.mm (Un-sheathed)
SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: c) Overall size 6 sq.mm (Un-sheathed)
Suuply of Tubelight set 20 w
Suuply of Led Bulb 20 w
Suuply of Fan 48"
Suuply of Flood Light 50 w
Crane 35 tonnes Lifting Purpose
Front End Loader 1 cum bucket capacity
Repair Of Control Panel 1) Conductor MN 100
Repair Of Control Panel 2)Over Load Relay
Repair Of Control Panel 3) Control Wire
Repair Of Control Panel 4)MCCB 630 Amper
Repair Of Control Panel 5)spare Link Kit
Repair Of Control Panel 6)Alminium strip control
Repair Of Control Panel 7) On Off Switch, Lamp, Ampere, Volt Meter And Painting Of Control Panel
Repair Of Control Panel 8)Labour Charges Control Panel
Repair Of 100 Hp Motor 1) Motor Rewinding 100 Hp
Repair Of 100 Hp Motor 2) Bearing 6316 skf
Repair Of 100 Hp Motor 3) Bearing No 316
Repair Of 100 Hp Motor 4)Connection Plate
Repair Of 100 Hp Motor 5)Connection Leeds
Repair Of 100 Hp Motor 6)Thimble Cupling Set
Repair Of 100 Hp Motor 7)Coupling Set 100 Hp
Repair Of 100 Hp Motor 8)Coupling Set 75 Hp
Repair Of 100 Hp Motor 8)Carriage Motor
Repair Of PF panel 1) Shant Capacitor Haevy Duty 160 KVA
Repair Of PF panel 2)Connector 33KVA
Repair Of PF panel 3) MCB 63 AMP
Repair Of PF panel 4) Control Wire, Thimble & Toping
Repair Of PF panel 5)MCCB 250 Amp L/T Make With Lenk
Repair Of PF panel 6) Excide 90 amp
Repair Of PF panel 7) Battery Charger
Repair Of Pumps 1) Pump Repair 100 Hp Ampler Repair
Repair Of Pumps 2) Gland Dori Sleve
Repair Of Pumps 3) Pressure Ring Plate
Repair Of Pumps 4) Neck Ring GM
Repair Of Pumps 5) Jain Kit
Repair Of Pumps 6)Bearing Size
Repair Of Pumps 7) Bearing 6308 SKF C4
Repair Of Pumps 8) Carriage of Pump from Workshop
Repair Of Pumps 9) Labour Charges
Repair of VCB (Vaccum Circuit Breaker)including oil etc and labour
Any Other Items
AMANDEEP SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .