Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹65.0 LAccepted-AOC ASSAM AS | HAILAKANDI | ASSAM | 788152 | 1 | Accepted-AOC ACCEPTED | |
| 2 | 2₹65.0 L+₹3,106.44 (0.05%)Rejected-AOC LOCATION ASSAM AS | 2 | Rejected-AOC REJECTED |
Tender Value
₹61.9 L
EMD Value
₹1.2 L
Closing Date
5 Feb 2024, 1:00 pmClosed
Superintending Engineer
Lakhimpur Building Circle, North Lakhimpur
Repair/Renovation of Model School at Murkongselek, Jonai in Dhemaji District
2024_PWBNH_35758_1
LBCNL/2023-24/Dhemaji/D-02
Open Tender
Civil Works - Building
Item Rate
360 days
LBC, North Lakhimpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,240
₹1.2 L
Yes
29 Feb 2024
29 Jan 2024
5 Feb 2024
29 Jan 2024
5 Feb 2024
29 Jan 2024
Amount
Providing and laying integral ement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: 22.7.1 :- With averager thicknmess of 120 mm and minimum thickness at khurra as 65 mm.
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In- Charge. The Joints system will be extruded aluminium base members, self aligning/ self centering arrangement and support plates etc. as per ASTM B221-02. The system wshall be such that it provides floor to floor/floor to wall expansion control system for various vertical location in load application areas that accomodates multi directional seismic movement without stress to its components. Sytem shall consist of metalprofiles with a universal aluminium base memners by utilizing manufacturer's pre-engineered self-centering arrangement that freely rotates/ moves in all directions. The Self- centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have waterlight joint is mandatory requirement all as per the manufacures design and as approved by Engineer-In-Charge. (Material shall confirm to ASTM 6063). 5.44.1:- Floor Joint of 100mm gap
Providing , hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, abnds, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement with 1:1.5:3 ( 1 cement : 1.5 Coarse sand (Zone-III) derived from natural sources ; 3 graded stone arggregate 20 mm nominal size derived from natural sources).
Steel reinforcemnet for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Half brick masonry with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundations and plinth in : 6.12.2 :- cement mortar 1:4 (1 cement : 4 coarse sand)
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.2 :- 1:4 (1 cement: 4 fine sand)
62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 Graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 ( 1 cement hardener mix : 2 graded stone aggregate. 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1:- water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade.
Providing and fixing Clorinated Polyvinyl horide (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints compplete as per direction of Engineer - in charge. External work 18.9.7 :- 65 mm nominal dia Pipes. Drain pipe from Roof slab to ground level
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S Sheets and galvanized with zinc coating of 120 gms/sqm ( both side inclusive) a per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm at 1200 mm centre to centre, one flange fixed to the ceiling etc 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095- (Part I) : 2011 ( Board with BIS certifications marks)
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side / top/ centre hung, with beading and all members suck as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joits mitred and flash butt welded and sash bars tenoned and riveted, including, providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excvluding the of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Wiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point wiyth 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point wiyth 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point wiyth 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 4 x 10 sq. mm + 1x 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as reqd. 4 x 16 sq. mm + 2 x 6 sq. mm earth wire
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 amps switch
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 A switch
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 A socket outlet
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6 pin 15/ 16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existiong modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as reqd.
Supplying and fixing following size/modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. 4 Module (125mm x 75mm)
Supplying and fixing following size/modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. 6 Module (200mm x 75mm)
Supplying and fixing following size/modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. 8 Module (125 mm x 125mm)
Supplying and fixing following size/modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. 12 Module (200mm x 150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the exisiting junction box/wooden block including connections etc. as required
Supplying and fixing brass batten/angle holder including connection etc as reqd.
Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as reqd.
Installation, testing and commissioning of Ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sq mm.FRLS PVC insulated, copper conductor, single core cable etc. as reqd.
Provding and fixing following rating and breaking capacity and pole MCCB with thermo amgnetic release and terminal spreadersin existing cubicle panel board including rilling holes in cubicle panel, making connections etc as reqd. 150A, 16KA, TPMCCB
Provding and fixing following rating and breaking capacity and pole MCCB with thermo amgnetic release and terminal spreadersin existing cubicle panel board including rilling holes in cubicle panel, making connections etc as reqd. 100 A, 30KA, FPMCCB
Supplying and fixingfollwoing way, single pole and neutral, sheet steel, MCB distribution board, 240 V , on surface/recess, complete with tinned cooper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as reqd. (But without MCB/RCCB/Isolator) 8 way, Double Door
Supplying and fixingfollwoing way, single pole and neutral, sheet steel, MCB distribution board, 240 V , on surface/recess, complete with tinned cooper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as reqd. (But without MCB/RCCB/Isolator) 12 way, Double Door
Supllying and fixing 5A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commisiioning as reqd. single Pole
Supllying and fixing 5A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commisiioning as reqd. Double Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc as reqd. 63 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc as reqd. 40 A
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A 240 v"c" curve DP MCB complete with connections, testing and commisioning etc. as reqd.
Earthing with copper earth plate 600 mm x 600 mmx 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc with charcoal/coke and salt as reqd.
Providing and layiing earth connections from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I pipe from earth electrode including connection with copper thimble excavation and refitting as reqd.
Supplying, installation, testiung and commisioning of ceiling fan, 1200 mm sweeep Usha made, APOLLP LX/or equivalent make complete with all accessories as reqd.
Supplying with fitting and fixing of LED 18/20W T-5 luminaries complte with all accessories such as ballast, starter etc directly on wall/Ceiling with making necessary connection as reqd.
Supplying and fitting of 9/12 watt LED lamp in the existing batten holder/Angle holder/bracelet/pendent holder etc as directed.
Sunil Gogoi
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .