| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1MILL VFD PANEL FOR 450 KW MOTOR | |||||
| 1.01 | Motor Duty Class IV- Accordingly VFD to be selected
• VFD Rating: 560 kw (Suitable for Constant Torque)
• Input Supply: 415V, 3Phase, 50 Hz
• VFD Rated Current: 1035A Minimum
• VFD Type: 6 Pulse
• The VFD should be rated for minimum 1035A at 50 Deg C Ambient Temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed range (VFD sizing/Derating Calculation to be provided to match this specification and motor overload class)
• Overload class-IV for Mill application:
150% Overload for 1 Hour
200% Overload for 120 Sec
Scope of Supply
• IP-42 floor mount panel, RAL 7035, bottom cable entry, (Make: Rita/BCH/Eldon/VFD OEM)
• LCD Graphical HMI on Panel Door
• Input ACB-1250A MDO Type, 3 Phase
• Multi Function Meter
• External input/DC Choke- 3% impedance for Harmonic Suppression
• VFD Output Filter- LC Filter/Choke- Minimum 3% Impedance
• AC VFD Module withRS 485 Modbus Communication, AI- 3 Nos, AO- 3 Nos & Relay Output – 3 Nos.
• VFD Start/Stop/Reset Push button on panel door
• VFD Speed inc-Dec push button on panel door
• RYB/Run/Trip indication
• Control wiring should be from Tin Platted Copper cable to avoid corrosion. (Control function shall be suitable for Mill application)
• Local/Remote/DCS Selector switch (One AI/2 AO/ 3 DO/2 DI for DCS operation)
• Galvanic Isolators for all 3 Analog input & Outputs
• Auxiliary contractor- (Relays are not acceptable)
• Back Curved high speed Cooling fan with MCB
• Control supply transformer with MCB
• Temperature Scanner -8 Window for Mill Motor
• Common mode Filter for reduces motor bearing noise and bearing current, thereby increasing motor bearing life.
• DOL Starter for Motor cooling with MPCB
• Panel space heater with thermostat
• Panel light with door switch
LCS/Remote Station
• IP55 Enclosure
• Start/Stop Push buttom, VFD Run/ Trip Indication) & FWD/REV Switch
• RPM Meter- 0 to 1500 RPM
Make: Amtech, ABB, Delta & CG
Note: Your Organization is responsible for the installation, commission and operation of the drive for the crushing season 2026-27 | 1 | Nos | 100 | ₹100 |
| 1.02 | Motor Duty Class IV- Accordingly VFD to be selected
• VFD Rating: 630 kw (Suitable for Constant Torque)
• Input Supply: 415V, 3Phase, 50 Hz
• VFD Rated Current: 1190A Minimum
• VFD Type: 6 Pulse (Control= DTC & safety= STO)
• The VFD should be rated for minimum 1190A at 50 Deg C Ambient Temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed range (VFD sizing/Derating Calculation to be provided to match this specification and motor overload class)
• Overload class-IV for Mill application:
150% Overload for 1 Hour
200% Overload for 120 Sec
Scope of Supply
• IP-42 floor mount panel, RAL 7035, bottom cable entry, (Make: Rita/BCH/Eldon/VFD OEM)
• LCD Graphical HMI on Panel Door
• Input ACB-1250A MDO Type, 3 Phase
• Multi Function Meter
• External input/DC Choke- 3% impedance for Harmonic Suppression
• VFD Output Filter- LC Filter/Choke- Minimum 3% Impedance
• AC VFD Module withRS 485 Modbus Communication, AI- 3 Nos, AO- 3 Nos & Relay Output – 3 Nos.
• VFD Start/Stop/Reset Push button on panel door
• VFD Speed inc-Dec push button on panel door
• RYB/Run/Trip indication
• Control wiring should be from Tin Platted Copper cable to avoid corrosion. (Control function shall be suitable for Mill application)
• Local/Remote/DCS Selector switch (One AI/2 AO/ 3 DO/2 DI for DCS operation)
• Galvanic Isolators for all 3 Analog input & Outputs
• Auxiliary contractor- (Relays are not acceptable)
• Back Curved high speed Cooling fan with MCB
• Control supply transformer with MCB
• Temperature Scanner -8 Window for Mill Motor
• Common mode Filter for reduces motor bearing noise and bearing current, thereby increasing motor bearing life.
• DOL Starter for Motor cooling with MPCB
• Panel space heater with thermostat
• Panel light with door switch
LCS/Remote Station
• IP55 Enclosure
• Start/Stop Push buttom, VFD Run/ Trip Indication) & FWD/REV Switch
• RPM Meter- 0 to 1500 RPM
Make: Amtech, ABB, Delta & CG
Note: Your Organization is responsible for the installation, commission and operation of the drive for the crushing season 2026-27 | 1 | Nos | 100 | ₹100 |
| 1.03 | Motor Duty Class IV-Accordingly VFD to be selected
• VFD Rating: 630kw (Suitable for Constant Torque)
• Input Supply: 415V, 3 Phase, 50 Hz
• VFD Rated Current: 1190A Minimum
• VFD Type: 6 Pulse
• The VFD Should be rated for minimum 1190A at 50 Deg C Ambient Temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed rang ( VFD sizing/Derating Calculation to be provided to match this specification and motor overload Class)
• Overload Class-IV for Mill Application:
• 150% Overload for 1 Hour
• 200% Overload for 120 Sec
(Control= DTC & Safety= STO)
Make: Amtech, ABB, Delta & CG | 1 | Nos | 10 | ₹10 |
| 1.04 | Motor Duty Class IV-Accordingly VFD to be selected
• VFD Rating: 560kw (Suitable for Constant Torque)
• Input Supply: 415V, 3 Phase, 50 Hz
• VFD Rated Current: 1035A Minimum
• VFD Type: 6 Pulse
• The VFD Should be rated for minimum 1035A at 50 Deg C Ambient Temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed rang ( VFD sizing/Derating Calculation to be provided to match this specification and motor overload Class)
• Overload Class-IV for Mill Application:
• 150% Overload for 1 Hour
• 200% Overload for 120 Sec
(Control= DTC & Safety= STO)
Make: Amtech, ABB, Delta & CG | 1 | Nos | 10 | ₹10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
VFDNIT.pdf
Tender Documents • 1.92 MB
VFDBID.pdf
Additional Documents • 0.39 MB
BOQ_351239.xls
BOQ • 0.28 MB
VFDCorrigendum.pdf
PDF • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].