| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC | L1 | Accepted-AOC BID OF M/S HUSSAIN AND BROS IS HEREBY ACCEPTED BEING L1 BIDDER | |
| 2 | L2₹46.5 L+₹2.8 L (6.44%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 BIDDER | |
| 3 | L3₹49.7 L+₹6.0 L (13.7%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING L3 BIDDER |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
22 Mar 2023, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG DIVISION PIN 793002
SPECIAL REPAIR TO BLDG NO S 17 AND S 18 (FAFA OR) AT ARC UNDER GE SHILLONG
2023_MES_582188_2
GE/SHL/TOKEN-84 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE SHILLONG
₹94,000
Yes
20 May 2023
9 Mar 2023
23 Mar 2023
9 Mar 2023
22 Mar 2023
9 Mar 2023
Amount
AGE B/R SCHEDULE PART - I S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed.
Excavating in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified.
Removing excavated materia/soill n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
Returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm of hard/dense soil complete all as specified.
M & L for Pre-cast cement concrete block masonry type C1 , 1:3: 6, 20mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in mortar 1:6 , complete all as specified and as directed.
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for providing Hardcore of gauge n exc. 63 mm size broken stone or boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:4:8 type D2 ( Using 40mm graded agg) as in foundation and mass concrete complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 ( 12.50 mm graded aggregate) as in levelling course of tile flooring etc. complete all as specified and as directed.
M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors, dado , skirting and riser etc, set and jointed in cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing course in cement sand mortar 1:4 complete all as specified and directed
M&L Glazed ceramic colour tiles of size 450 x350 x 7mm thick in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete as specified and directed.
M&L for chequered cement concrete tile with grey cement and pigment (of approved tint) of size 20 cm x 20 cm x 25mm thick over and including 15 mm thick screed bed in cement Mortar 1:6, set, jointed and pointed in neat cement slurry complete all as specified.
Demolition cement Concrete (RCC chimney, RCC slab) of any description and in any position not otherwise specifically provided for complete all as specified.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in kitchen slab, cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete. Note:- Reinforcement steel will be measured & paid sepratly.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
Demolition of stone slabs and granite laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc all as specified and directed.
M& L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 20 mm thick screed bed in CM 1:3 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M& L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with 10 mm thick baking course in CM 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M & for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for rounding to edges of stone slabs one edge, such as in steps cooking plateform, and other similar situation complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection/path incl finishing even & smooth with using extra cement in, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 20mm graded aggregate) as in surface channels and drains complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.and applying cement slurry @3kg/Sqm (ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and as directed.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling,including dismantling wall and ceilling boards of any description including cover fillets complete all as specified and directed.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section of unframed work complete all as specified and as directed.
M&L for 2nd class hard wood plain fillets bullnosed, splayed, chamfered or rounded on one edge or face in section clean sawn, fixed with screws sec are exc 6 sq cm n exc 13 sq cm complete all as specified and as directed.
M&L for 2nd class hard wood plain fillets bullnosed, splayed, chamfered or rounded on one edge or face in section clean sawn, fixed with screws sec are exc 3 Sq cm and n exc 6 sq cm complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S & F 500 litres capacity , rotational molded, polythene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling complete all as specified and as directed. Make : Sintex, Polycon, waterwell.
Cleaning of service water tank capacity upto 500ltr RCC/PVC and the connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush, draining out the water in the tank and washing internally by using bleaching powder and again draining out the water in the tank and applying single coat of lime washing on RCC tanks( Rate includes cost of writing date of cleaning with paint after removing the old date by painting including disconnecting existing tanks,setting aside (or lowering if reqiured) for repairs claening etc and hoisting if required reconnecting and re-fixing in same position of capacity of water tanks of Exc 250 Ltrs & N.exc 500Ltrs all complete). all as directed by Engineer-in-charge for the following capacities:
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm th in CM 1:4 using finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and as directed on External surface. Note:- WPC will be measured & Paid separately
M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed.
M & L for rendering 05 mm thick in CM 1:3 on ceiling surfaces of cement concrete and finished the surface even and smooth without using extra cement complete all as specified & directed .
Supply only for water proofing compound complete all as specified and as directed.
M&L for complete removal of existing treatment from external surface of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer,complete all as specified and directed
M&L for preparation of new plaster external surface of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer,complete all as specified and directed.
Complete removal existing treatment and applying 1mm thick of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed.
M & L for preparation of new plastered/concrete surfaces of walls and applying 1mm thick of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified.
M & L for preparation of old decorated surfaces (plastered or unplastered) and applying two coat of white wash on the surfaces of ceiling complete all as specified and directed by Engr-in-Charge.
M & L for preparation of new plastered/concrete surfaces of ceiling, applying three coat of white wash on the surfaces of ceiling complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of Synthetic enamel paint complete all as specified.
Taking down GI tubing 15mm dia and connection including removable to store complete all as specified and directed.
Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete all as specified and as directed.
Refixing only 15mm tubes any grade, to walls and ceilings or laying in floors complete all as specified and directed.
Taking down GI tubing 20mm dia and connection including removable to store complete all as specified and directed.
Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete all as specified.
Refixing only 20mm tubes any grade, to walls and ceilings or laying in floors complete all as specified and directed.
M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete.
S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. .
S & F in repair 15 mm bore CP fancy type bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair Powder coated fancy type Anodised aluminium alloy curtain rod 25mm dia including PVC rings @ 100mm c/c with suitable brackets matching to curtain rod of make as as approved by GE complete all as specified and as directed. [ Additional supporting bracket shall be provided if length is exceeding 1.2m and rate quoted shall include for the same ]
S&F in repair brass chromium plated tubular towel rail 600mm long between the flanges and 20mm dia complete all as specified and directed.
S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F as in repairs.Vitreous China wash down water down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete.
S & F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as directed by Engineer-in-Charge
S&F in repair Stainless steel sink with draning board, made out of 1.00 mm thick sheet with waste fitting, cast iron cantilever brackets, connecting union overall size 915 mm x 460 mm with bowl size 410 mm x 330 mm x 160mm complete all as specified and directed by Engineer in Charge.(Make : Bluestar,Nirali or equivalent.)
S&F for stainless steel kitchen rack of size 36”x 36” x 10” complete all as specified and directed by Engg-in-charge.(Make : Bluestar,Prayag or equivalent.)
S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified and as directed.
S&F in repairs PVC (SWR) bend with access door of 110mm bore complete all as specified.
S&F in repairs PVC (SWR) bend with access door of 75mm bore complete all as specified.
S & F in repair 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed.
S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F in repair PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal complete all as specified and as directed.
S & F in repair 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specofied and directed.
S&F in repair PVC (SWR) pipes 50 mm dia single socketed in any length with rubber ring joints , laid in trenches or in floors as spout pipe complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC (1:5:10) type E2 (using 40mm graded agg) as in sub base of WC complete all as specified and as directed..
M&L for water proofing treatment to sunken portion of RCC slab with the following courses of treatment/specification :- (i) For Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in sunken portion with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (ii) Preparation of plastered roof surface and applying one coat of cold bituminous primer @ 0.25 ltr /Sqm conforming to IS:3384-1986. (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied by torch application over bituminous primer as specified. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. Note:-The work of sunken portion treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. Contractor shall submit documentary evidence on support of applicator engaged for approval of GE.
Taking down chowkhats or frame with shutter without taking off shutter from the frame exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame not exc 1.50 sqm & removing from site complete all as specified and directed.
Taking down shutter of any description n.exc 1 Sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but not exc 2.00 sqm each complete all as specified and directed.
S&F MS flat iron such as small articles for hold fast and similar work all as specified and as directed by Engineer-In-Charge.
M&L PCC (1:2:4) type B1 (20mm graded Aggregate) for fixing hold fast complete all as specified.
Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
S & F 30mm thick II class HW Glazed and skeleton windows, ventilators, etc are provided with stiles and rails with sash bar complete all as specified in SSR Part I section 8 clause 8.24 (b) all specified and directed.
Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Supply and fixing 100mm size butt hinges cold rolled medium weight, ISI marked complete all as specified and directed.
Supply and fixing 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
Supply and fixing 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
Supply and fixing 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed.
Supply and fixing 75mm size butt hinges cold rolled medium weight ISI marked complete all as specified and directed.
Supply and fixing 100mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
Supply and fixing 100mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
S & F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
S & F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all a specified.
Supply and fixing in repairs 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple, ISI marked, complete all as specified and directed.
Supply and fixing in repair 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
Supply and fixing in repair 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples comlete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed.
S&F Sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&F one side frosted glass 3 mm thick, glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
Forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete
Resecuring or easing & adjusting without taking down the shutter of any description exc 1 Sqm and n.exc 2 Sqm in same opening complete all as specified and directed.
S & F in repair 18/19mm thick Block boards, as in cupboards and simimlar work grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete all as specified and as directed.
S & F 40mm width of flaps when open Continuous (piano) hinges,mild steel, bright finish or electro galvanised complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and dircted.
S&F for MS frame work such as grills grating etc, with ends of bar shouldered and or riveled, or forged into spickes framed quared bars and similar work all as specified and directed by EIC.
S& F Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. inclug cleats, (Fe-410) brackets, etc.complete all as specified and as directed.
M&L for preparation of new steel surface and applying of two coat of synthetic enamel paint over a one coat of red oxide exc 10cm width or girth all as specified and directed by Engr-in-charge.
AGE E/M SCHEDULE PART - II Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Material and labour for point wiring with single core PVC insulated unsheathed cable of size 1.5 Sqmm nominal area with multi-stranded FRLSH copper conductor, 1100 Volt grade drawn through and including PVC non metallic surface casing capping of suitable size with all fitting and accessories including PVC modular board of suitable size for housing/mounting the modular switches/sockets, etc top covered with plastic laminated sheet 3mm thick including 1.5 Sqmm PVC insulated unsheathed single core FRLSH copper conductor earth continuity wire connected to common earth dolly complete for one light/fan point controlled by one way switch including making good disturbed surfaces complete all as specified and directed.
All as per Item No. 118 above but for One light point controlled by two 2-way switches,complete all as specified and directed.
All as per Item No. 118 above but for One bell/buzzer point controlled by one push button ,complete all as specified and directed.
All as per Item No. 118 above but for one 2/3 pin socket outlet, 5 Amps on independent board, complete all as specified and directed.
All as per Item No. 118 above but for one 2/3 pin socket outlet, 5 Amps on same board, complete all as specified and directed.
All as per Item No. 118 above but with FRLSH, ISI marked PVC insulated and unsheathed two single core multistranded copper cable of size 2.5 sqmm for one power point ,3 pin 15 Amps on independent board includingFRLSH, ISI marked PVC insulated unsheathed single core multi-stranded copper cable of size 2.5 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. Make- Cable- Finolex/RR cable/Havells, PVC Casing Capping- Presto plast/Finolex/Kalinga.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S&F Switch socket combination 2 in 1 5A/16A, 3 pin 1 flush type universal complete all as specified and directed.
S&F Switch socket combination 2 in 1, 5 A flush type complete all as specified and directed.
S&F socket outlet 2 in 1, 5 A flush type complete all as specified and directed.
Supply and fix switch piano type two way 240 volts, 6Amps all as specified and directedcat part No: 1066 of Anchor cona gold series or equivalent in SSK/Havells
Supply and fixing LED batten fitting 18 Watt, 6500K fixed to wall with 2 nos PVC block of suitable size complete all as specified and directed including taking down old unserviceable light fittings.
Supply & fixing bell push, 6 Amps, Flush type, Single pole, one way, modular, 230 volts complete all as specified and directed. Make : Anchor/SSK/Havells
S&F of bell electric, Dingdong type A.C. 230 Volts, single pole Make : Anchor/SSK/Havells
Supply & fixing 7 watt LED lamp B22 type complete all as specified & directed by Engr-in-Cjarge. Make : Phillips/Bajaj/Havells
M&L ceiling rose, 3 terminals PVC/polycarbonate, isolated body complete all as specified and directed.
S&F lamp holder, insulated body, with back plate for batten fitting complete. Make- Havells/anchor/Legrand.
Material and labour for sub main wiring with two single core 6.0 sqmm FRLSH, ISI marked PVC insulated multi stranded, unsheathed copper conductor cable and one single core unsheathed FRLSH , ISI marked, PVC insulated multistranded copper conductor cable of size 6.0 sqmm green colour as earth lead including PVC casing capping of suitable size complete all as specified and directed, including taking down unservicable one.(Note: two run of 6.0 sqmm cable , one run of earth wire of 6.0 sqmm and one run of PVC casing capping shall be measured as one length).Make- Cable- Finolex/RR cable/Havells, PVC Casing Capping- Presto plast/Finolex/Kalinga.
Supply and fix MCB Distribution board , 240 volts Single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed including taking down old unserviceable one.
Supply and fix MCB SPN, 240 Volt, 32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed iIncluding taking down old one.
Supply and fix MCCB Distribution board , 415 volts verticle triple pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed including taking down old unserviceable one.
Supply and fixing MCCB four pole 63 Amps, 415 Volts including taking down old one all as directed.
Supply and fix MCB SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed iIncluding taking down old one.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
M/S U.K ENTERPRISE
Ms Amrik Singh Bahra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .