Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.6 LAccepted-AOC 256 MUNDHELA KHURD NEW DELHI 73 | WEST | DELHI | 110008 | L-1 | Accepted-AOC Work Awarded | |
| 2 | L-2₹3.6 L+₹420 (0.12%)Rejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L-2 | Rejected-Finance L2 rejected | |
| 3 | L-3₹4.0 L+₹38,632 (10.7%)Rejected-Finance | L-3 | Rejected-Finance L3 rejected |
Tender Value
Refer Docs
EMD Value
₹8,848
Closing Date
12 Jul 2023, 12:00 pmClosed
Ex. Engineer (Elect)-II
OFFICE OF THE Ex. ENGINEER (ELECT)-II, SHAHDARA (N) ZONE, Keshav Chowk, Delhi-110053
Provision of Semi High Mast Light Pole with 150 Watt LED fitting at Opposite Dev Medicos and Near SI Office main road Johripur in Ward No. 240 Under Shahdara (North) Zone
2023_MCD_159950_1
EE(E)-II/SNZ/MCD/23-24/TC-4/2
Open Tender
Electrical Works
Item Rate
90 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹8,848
19 Jul 2025
5 Jul 2023
13 Jul 2023
5 Jul 2023
12 Jul 2023
5 Jul 2023
Amount
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. Wire on surface or in recess for loop earting along with existing surface/recessed conduit/submain wiring/cable as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. 63 mm dia (OD- 63mm & ID-51mm nominal).
Supply of XLPE Insulated PVC Sheathed AI. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098 (Part-I) 1998 as required. 2x10sqmm
Fabrication , Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thik (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumfrential weld. It should also included accessories For High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmitrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, provinding of cutting, bending and placing in position, reinforcementc of cold twisted bars of 12 mm dia- 2100mm long (approx) -13 nos. (with 150mmspacing) as required with positioning of foundfation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering. The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c ,4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacture shall be embossed on the pole. Galvanization as per relevant IS.
SITC of 150 W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd. with IP 66 Protection (a) Total system wattage= 150 watt+/- 5%. (b) Luminaire Efficacy>= 100 Lm/w. (c) Power Factor>=0.95. (d) Protection Class-IP-66
M/S. A.K. Electricals
The Electrician
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .