| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Lowest Bid Value. | |
| 2 | L2₹22.3 L+₹31,861 (1.45%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L2 | Rejected-AOC Higher Bid Value. | |
| 3 | L3₹26.5 L+₹4.5 L (20.6%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-AOC Higher Bid Value. |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
10 Jul 2021, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
CERTAIN SPECIAL REPAIRS / REPLACEMENT OF E/M ITEMS AT HQTC BANGALORE
2021_MES_451235_1
8802/GE/42
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹58,000
Yes
7 Sept 2021
14 Jun 2021
12 Jul 2021
14 Jun 2021
10 Jul 2021
28 Jun 2021
15 Jun 2021 - 23 Jun 2021
Amount
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fittings such as switches, ceiling rose, pendants, regulators, sockets, light fittings and removing retrieved materials and making good the disturbed surface, complete all as specified and directed.
Taking down ceiling fan, cealing cable end, dismantaling blades, and removing fan including painting and refix the same including connecting up and provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
Point wiring with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl heavy grade PVC casing caping ISI marked including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor branded PVC moulded modular gang box fixed on wall surface with Modular suitable plate with cover and suitable screws for housing switches socket outlets fan regulators etc., complete all as specified and directed for the following ;- Make:- .Finolex / Ravi Cab / NICCO or equivalent make.
One light/Ceiling fan point controlled by one single pole 5 Amps switch
One switch socket out let point 5 Amps on independent board
One socket out let point 5 Amps on same board with other switches
One bell point controlled by one bell push
All as per item No 3 here in before but with copper conductor cable FLRS 2.5 sqmm for one 3 pin socket outlet,15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Switch piano flush type single pole one way 6 Amps, complete all as specified and directed.
Bell push piano type 6 Amps, complete all as specified and directed.
Socket 2/3 pin multi purpose 6 Amps flush type, complete all as specified and directed.
Switch piano type 16 Amps flush type universal, complete all as specified and directed.
Socket multi purpose 2-in-1, 6 pin 6/16 Amps flush type universal, complete all as specified and directed.
PVC ceiling rose 65 x 50 mm surface type with 3 terminals, complete all as specified and directed.
Stepped type electronic fan regulator flush type, complete all as specified and directed.
Calling bell, 230 V, AC, single pole fancy type Ding Dong Bell and including taking out unserviceable old bell, complete all as specified and directed.
Lamp holder, insulated body with back plate for batten fittings including 09 watt LED bulb, complete all as specified and directed.
Sub main wiring with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 6 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly, fixed as in repairs, complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
Taking out old underground cable of any size and any core, complete all as speciifed and directed.
Cable XLPE insulated screened PVC bedded, galavanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor, complete all as specified and directed for the following sizes :-
240 sqmm 3.5 core.
120 sqmm 3.5 core.
16 Sqmm 4 core
10 Sqmm 2 core
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in hard/dense soil for laying of cable trenches, complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm, complete all as specified and directed.
Removal of surplus soil (excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed.
Sand cushioning with fine sand as specified in clause 14.5 of SSR Part-I to under ground cable in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed.
Unreinforced precast concrete cable cover as in 1:1½:3, type A-1, class LV, Type I, flat, of size 250mm X 150mm X 40mm laid dry over power cable for protection, complete all as specified and directed.
Tubes 'light grade' galvanised 50 mm dia with all fittings in trenches for passing of cables, complete all as specified and directed.
Cutting existing road surfaces or hard standing 0.45 mtr depth (22 CM thick comprising bituminous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing, complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 110mm dia suitable for 0.4mpa working pressure, complete all as specified and directed.
Rigid PVC trunking white colour of 180mm x 50mm with cover for service/ miscellaneous cable complete with fitting such as joints/Tec/elbow/coupler etc., com[lete all as specified and directed.
400 Amps ON LOAD Change Over switch front handle operated 415V 50hz four pole all open execution type, complete all as specified and directed.
MCCBs 250 Amps Four Pole 35KA in replacement of old unserviceable MCCB's, complete all as specified and directed.
PVC (SWR) 'S' trap 110mm bore, fixed as in repairs, complete all as specified and directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms), fixed as in repairs, complete all as specified and directed.
PVC (SWR) 110mm bore floor trap, plain with grating including jointing with solvent cement, fixed as in repairs, complete all as specified and directed.
15mm Bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, fixed as in repairs, complete all as specified and directed.
Shiva Shakthi Electrical Enterprises
RRK PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .