Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.5 L+₹1.8 L (13.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹15.7 L+₹2.0 L (14.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹17.6 L+₹3.9 L (28.5%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹20.8 L+₹7.1 L (52.2%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹19.8 L
EMD Value
₹39,600
Closing Date
25 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Maint and repair of STPs under GE Gurdaspur.
2023_MES_616005_1
GE GSR-48/2023-2024
Open Tender
Civil Works
Item Rate
240 days
GE Gurdaspur
As per Tender Documents
8 documents required · 8 mandatory
₹500
₹39,600
30 Nov 2023
28 Aug 2023
2 Oct 2023
28 Aug 2023
25 Sept 2023
12 Sept 2023
Amount
Repair to STP main panel control panel by disconnecting all electric connections and dismentling the annuciator, alongwith all connected parts and reassembling after necesssary repair, replacement of lugs,dressing of cable, replacement of connector blocks, nuts bolts and washers of suitable size and joints complete all as specified and directed.
Dismantling and disconnecting of all electrical connections of non clog submercible pump rating 9.5 KW & discharge of 60 m3/hr , taking out from sewge well dismantling of pump, shaft impeller unit etc and shifting it to work shop for reparing and reassembling and return back from work shop after repair to the site by transport and lowering it to sewage well after testing and commissioning complete all as specifiec and directed by Engineer in charge. Note: Spare parts and rewinding shall be measured and paid separately.
Material and labour for Dismantling/opening the burnt motor, (Rotor & stator ) rewinding the motor with super enamelled copper winding as per existing gauge including insulation material cotton tape, varnish, insulation paper, sleeves and dry and backing etc including replacing of bearing and reassembling complete motor. complete all as directed. Note - The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation all as directed .
Supply and fix in replacement of SS impeller for 9.5 KW & discharge of 60 m3/hr non clog submersible pump as per existing make and capacity complete.
M&L for repair pump shaft by filling of suitable material by welding and turning of pump shaft of capacity 9.5 KW & discharge of 60 m3/hr non clog submersible pump complte all as specified and directed.
Supply and fix in replacement of mechanial oil seal for 9.5 KW & discharge of 60 m3/hr submersible pump as per existing make and capacity complete.
Supply and fix in repair of framed work such as grills, gratings, etc. with ends of bars shoulders and / or riveted, or forged into spikes , framed guard bars, barred iron doors, ladders, framed balusters, railings and similar article as in strainer fabrication for MBBR including welding work etc. conforming to Fe-290 Grade-E-165 complete all as specified and directed.
Supply and fixing in replacement of MCB 32 Amp, 4 pole with rupturing capacity10 KA C curve. Make Schenider /Legrand /Siemens .
S&F in replacement of MCCB 160 Amps 4 Pole 25KA, Make- L&T and equivalent complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCCB 63 Amps 4 Pole 25KA, Make- L&T and equivalent complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCCB 32 Amps 4 Pole 25KA, Make- L&T and equivalent complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of fan belt SPB-PT 1800 suitable for Air blower complete all as specified and directed.
S & F in replacement of fan belt SPZ-1600 suitable for sludge transfer pump complete all as specified and directed.
S & F in replacement of fan belt SPZ-1320 suitable for sludge feed pump complete all as specified and directed.
S & F in replacement of 3 pole power contactor MNX 25 heavy duty with contineous current rating of 25 Amp AC 3, 415 Volt complete all as specified and directed.
S & F in replacement of 3 pole power contactor MNX 32 heavy duty with contineous current rating of 32 Amp AC 3, 415 Volt complete all as specified and directed..
S & F in replacement of thermal over load relay 10 to 16 Amp, /415 Volt complete all as specified and directed.
S & F in replacement of electronic timer for star delta starter 415 volt timing range 3 sec to 60 sec. complete all as specified and directed.
S&F in replacement voltmeter digital LED type, 0-500V complete all as specified and directed.
S&F in replacement 3 phase digital LED type ammeter, 0-100 Amp complete all as specified and directed.
S&F in replacement indicator lamp RYB LED type complete all as specified and directed.
S & F in replacement for push button ON(green) / OFF(Red) set complate all as specified and directed.
M&L for Rewinding of Electric induction motor 60 HP( Motor of air blower ) including disconnecting electrical connection carefully and shifting to workshop and opening the electric motor rotar & stater. Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve and reassembling the motor shift at site and connecting, testing on load. Note - (a) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation all as directed
All as per item srl no 24 here in before but capacity of 10 to 15 HP (Motor of Anoxic Recirculation pump)
All as per item srl no 24 here in before but capacity upto 10 HP (Motor of sludge transfer pump , sludge feed pump, Centrifuge, dozing pump)
M&L for repair to Air compressor of capacity of 45 KW & discharge of 1840 m3/hr of deffusers coarse bubble/ nozzles including opening carefully and leaning/ repair/ replacement rotary turn lobe air blower with air filter, silencer, gauge, safety valves, drive bearing and bearing (Gear side) Oil seal drive end long shaft and short shaft, lip seals gear and bearing cover, gasket gear cover and welding grinding & polishing drive rotor shaft assembly as per bearing size. Replacement the recommended oil grade and greasing and assembling and testing on load. Note : (a) One year warrenty to be given by the contractor, any defects in the warranty period to be repaired by contractor without any extra cost to Govt. (b) Cost of air filter is included in quoted rate.
Supply and fix in replacement of CI Butterfly valve heavy grade with stainless steel stem & disc size150 mm dia complete all as specified and directed
All as per item Srl No 28 here in before but size 100 mm dia.
All as per item srl no 28 here in before but size 80 mm dia.
All as per item Srl No 28 here in before but size 50 mm dia.
Supply and fix in replacement cast iron non returning valve (Reflux with by pass) with flanged both ends of size150mm dia bore.
Supply and fix in replacement cast iron Non return butterfly valve 200 mm dia complete all as specified and directed
All as per item Srl No 33 here in before but size 150 mm dia.
S&F in replacement CI sluice valve class PN- 1.6 ISI marked with stainless steel spindle and gun metal working parts, flanged both ends of size 80 mm dia bore with hand wheel complete all as specified and directed.
S&F in replacement of gun metal/globe or gate valves of 20mm dia with iron wheel head, ISI marked confirming to IS-780, screwed both ends for iron pipe and fixed.
All as per item Srl No 36 here in before but size 25 mm dia.
Supply and fix in replacement of submercible PVC 2.5 Sqmm, 8 core copper cable , 1100 volts conforming IS 694:1990 complete all as specified.
Supply and laying LT cable XLPE insulated armoured heavy duty electric with aluminium conductor cable 1100 volt grade 150 Sqmm 3.5 core including taking out/down existing cable all as specified and directed. Note: Excavation and earth work, sand cushioning, brick protection, GI pipe shall be measured and paid separately.
Supply and laying LT cable XLPE insulated armoured heavy duty electric with aluminium conductor cable 1100 volt grade 50 Sqmm 3 core including taking out/down existing cable all as specified and directed. Note: Excavation and earth work, sand cushioning, brick protection, GI pipe shall be measured and paid separately.
All as per item Srl No 40 here in before but size 16 sqmm 4 core.
All as per item Srl No 40 here in before but size 10 sqmm 3 core.
Supply and laying PVC cable duty electric with aluminium conductor cable 1100 volt grade 2.5 Sqmm 3 core including taking down existing cable all as specified and directed.
Supply and fixing cable jointing kit 110 V grade cable for out door termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 150 Sqmm
Supply and fixing cable jointing kit 110 V grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 150 Sqmm
Material & labour for cleaning of Equalisation sewage tank (Dia 11.5m, height 3m) for 2.5 MLD STP, by cleaning with brush entire internal surface by removing dirt, sludge etc and throw away not exceeding 50m from site, applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water including using sludge cutter pump and suction pump suitable capacity surface complete in all in as specified and directed, using acid and other suitable methods, taking out air piping, descaling, clear holes and refixing the same all as specified and directed by Engineer in charge. Note - Quoted rates shall include for using ladder for man entring in to tank for removing of sludge from tank and de watering will be done by the contractor at his own arrangements.
Material & labour for taking out MBBR media from tank & cleaning of MBBR tank (Dia 7.8m & height 6.2m) for 2.5 MLD STP, by cleaning entire internal surface by removing dirt, sludge etc. with brush by applying bleaching powder and fresh water including relaying of MBBR media. The cleaning of tank includes following:- (a) Taking out MS/HDPE pipe with strainer , descaling the pipe and taking out the strainer, cleaning of strainer/ repair by suitable welding or replacement of stainless steel bars as required at site. (b) Descaling of air grid and cleaning of holes for air piping. (c) Applying two coats of epoxy paint over a coat of red oxide primer on all piping inside MBBR tanks and inner surface of tanks. Note: Supply only of new MBBR of required quantity shall be measured and paid separately under item No. 68 below.
Material & labour for cleaning of tube settler with intermediate tank ( length 12.7m, width 6.5m) for 2.5 MLD STP, by cleaning entire internal surface by removing dirt, sludge etc. with brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water, cleaning of channels and applying chemical inside Tube settler tank and applying two coats of epoxy paint over a coat of red oxide primer on inner surface walls of tanks. Note - Quoted rates shall include for using sludge cutter pump and ladder for man entring in to tank for removing of sludge from tank and de watering will be done by the contractor under his own arrangements.
All as per Srl item No 48 but of Hypo solution tank with chlorine tank for 2.5 MLD.
Material and labour for Cleaning of Grit chamber, Bar screen & stilling tank as described below:- (i) Dewatering with submercible / sludge pump to empty the sump/ tank upto base level. (ii) Removing sludge from sump wall and bottom with the help of special sludge pump and removing remaining dirt which may have hidden in rough slots of the bottom mannualy with brush.(iii) After cleaning the sump apply bleaching powder for disinsfection of sump. Note: - Cleaning of Grit Chamber, Bar Screen, Stiling chamber will be considered as one job for payment.
All as per Srl item No. 50 above but for treated water tank at STP 1 & STP 2.
All as per Srl item No. 50 above but for clear water tank at 8 difference locations.
S & F in repalcement of Single phase preventor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of MCB single pole rating 6 Amp 10KA complete all as specified and directed.
M&L for complete removal of existing paint and Painting of pipes of size upto 150 mm bore with two coats of synthetic enamel paint over one coat of red oxide primer including connected fittings, nut, bolts etc. complete all as specified and directed.
Painting of following installed machineries at 2.5 MLD STP by spraying one coat of synthetic enamel paint as per colour coding including preparation of surface complete all as specified and directed. (a) Sand Filter & Activated carbon filter (b) Anoxic recirculation pump 1 No (c) Air blower 2 Nos (d) DWPE Dosing pumps 2 Nos (e) Sludge transfer pumps 2 Nos (f) sludge feed pumps 2Nnos (g) Centrifuge 1 No Note:- Painting of connected pipes will be measured separately under item No 55 above.
Supply only fresh cow dung for maintaining MBBR complete all as specified and directed.
Supply only Uria for maintaining MBBR complete all as specified and directed.
Supply only DAP for maintaining MBBR complete all as specified and directed.
Supply only Jaggery for maintaining MBBR complete all as specified and directed.
Attending electric complaint of sewage/ water supply installation to check auto star delta starter, voltmeter, ammperemeter in pump panel, change over switch and making funtional by rectification of minor defects, replacing the brunt lugs of cables complete all specified and directed.
Removal of dry sewage from dry bed and deposting outside the cantt area complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of terminal block 4way/6way as required and directed, barrier type, panel mountable with current carrying capacity of upto 25A, suitable for voltage of 415 volts, complete with screws and other accessories complete all as specified and directed.
Supply and spraying glyphosate 41% SL Glykol Herbicide to remove vegatation from STP Installation area including T&P required for spraying complete all as specified and directed by Engr-in-Charge
Supply and fix in replacement of 4 Sqmm, 3 core PVC insulated & Sheathed copper flexible cable complete all as specified.
S&F in replacement of control wiring of control panel with new PVC insulated, unsheathed, copper stranded conductor wire 1.5sqmm size including testing all as direced by Engineer-in-Charge
Supply and fixing in replacement new generation energy saving IP66 street light luminiaries withlong life versatle pressure dia-cast aluminium road way luminaire with high power LED 45 watt including GI pipe bracket made out of GI pipe light grade 32 mm bore and bent to shape 1.5m long, MS clamps made out of MS flat iron of size 40mm x 5mm thick and drilling of hole for and including nuts, bolts and washers including painting MS clamps with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed.
Supply only floating type media black for MBBR as per sample complete all as specified and directed
Supply and Fixing in replacement CI pipe of 150 mm bore ISI marked with flanged ends centrifugally cast class A, with CI screwed and drilled flanges with rubber gasket joint etc. complete all as directed
Supply and Fixing in replacement ductile iron (DI pipes ) centrifugally cast (spun) pressure pipe class K-9 size 100 mm ISI marked with internal cement mortar lining and external zinc and bitumen coated pipe 100mm bore with all spogot and socket ends with push on rubber gasket joint etc all as directed.
All as per Srl item No 70 here in before but size 150 mm bore.
S&F in replacement GI tubing , medium grade, galvanised, with all fittings, laid in trenches of size 80 mm bore complete all as specified and directed.
All as per Srl item No 72 here in before but size 50 mm bore.
All as perSrl item No 72 here in before but size 25 mm bore.
All as per item srl no 72 here in before but size 20 mm bore.
S&F in replacement unplatisised PVC pipe of pressure rating 10kgf/sqcm with all fittings of size 15 mm bore fixed to wall, ceiling or in floors complete all as specified and directed.
S&F in replacement UPVC pipe (SCH-80) with all fittings laid in vertical position in MBBR of size 250 mm bore complete all as specified and directed. Note :- Pipes will be used in MBBR in vertical position
S&F in replacement UPVC pipe (SCH-80) with all fittings, of size 150mm bore complete all as specified and directed.
Supply and fixing in replacement 500 litres capacity, rotational moulded polythelene water storage tanks white ISI marked (cylindrical vertical with closed top), hoisted and fixed in postion complete all as specified and as directed.
Collection of treated water sample from STP l & ll and analysis quarterly and when directed and getting the sample tested from a govt approved laboratory and submission of report to Engr-in charge. Parameters such as pH, TSS (mg/l), TDS (mg/l), EC us/cm, COD (mg/l), BOD (mg/l), Chloride (mg/l), Sulphate (mg/l), Oil & Grease (mg/l), T. Coil MPN/100 ml, F. Coil MPN/100 ml, SAR (mg/l), Amn nitrogen (mg/l) TKN (mg/l), T. Phosphorus (mg/l), RSC (mg/l) or any other test as per CPCB Norms all as specified and as directed.
M&L for preparation of old painted surfaces of one MBBR tank and apply two coat of exterior acrylic emulsion paint, colour and make as approved by Engineer-in-Charge complete including marking/ writing of date of cleaning, due date of cleaning, capacity of tank in front side with two coats of synthetic enamel first quality paint including making background surface black and at height including Making good the distrubed surfaces as directed by Engineer-in-Charge. Note :- (a) Arrangement of scafoldings, safety belts, helments and other safety measures while painting are responsibility of contractor. The contractor should take the insurance of his workforce who are working on heights.The cost of the same is deemed to be included in the quoted rates.
All as per Srl item No 81 here in before but of tube settler tank with intermediate tank
All as per Srl item No 81 here in before but of Hypo solution tank
All as per Srl item No 81 here in before but of Grit chamber, Bar screen & stilling tank Note:- Painting of Grit Chamber, Bar Screen, Stiling chamber will be considered as one job for payment.
Demolition of old unserviceable valve pits and constructing of brick masonary pits of internal dimensions 1m x1m x1.2m. Brick work shall be in CM 1:4. PCC floor of the pit shall be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space, floor of the pit shall be 10 cm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, finished even and smooth without using extra cement, internal and external surfaces of the pit shall be plastered in CM (1:4) 15 mm thick. Coping shall be in PCC 1:2:4. The sluice valve and other fittings shall be housed in centre of the pit. The top cover of the pit will be made out of MS sheet 3mm thick and angle iron frame of size 50mm x50 mmx 6 mm with galvanised steel hindges two Nos and locking arrangements, duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded with 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same, GI plate connected with galvanised steel strip of size 25x4 mm by means of GI nuts, bolts and washers, strip laid in 50mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) Test point GI strip of size 25x4. (b) Watering pipe GI Medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 40mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.(d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover including excavation, earth work, gun metal test point, MS funnel with brass wire mesh including taking out existing earthing complete all as specified and directed.
Supply & fixing in replacement of float switch N1 10m for sewage pump including electric connection complete all as specified and directed
Supply & fixing in replacement of unserviceable flow meter electromagnetic type , average flow 2 mld complete all as specified and directed.
Supply only potassium dichromate for COD testing complete all as specified.
Supply only mercuric sulphate for COD testing complete all as specified.
Supply only farrous sulphate for COD testing complete all as specified.
Surface dressing n. exc 15 cm deep of soft/loose soil including site clearance to remove vegetation and/or small inequalities at STP installations area complete all as specified and directed by Engr in charge. Note :-Leveling of the disturbed surface will be done by tractor etc.
Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n.exc. 1.5m in depth for poles, stay, cable, pipe etc.and getting out including taking out brick protection complete all as specified.
Removal of excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, leveling,watering and well ramming in layers each n.exc 25 cm thick in soft/ loose soil all as specified.
Supply and lay brick common burnt sub class "B" old size for protection of cable laid in trenches for under ground cable all as specified.
M&L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers complete all as specified and directed.
M&L in replacement for gear oil fully synthetic EP 90, API GL-4/GL-5 or above for gear lubrication complete all as specified and directed by Engineer-in-Charge.
A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
SEALINE BUILDERS
KAILASH CONSTRUCTION CO
HARPAL ENGINEERS AND BUILDERS
kailu construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .