Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 108 BADA CHAKA NAINI ALLAHABAD | ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical document are not as per requirement |
| 5 | Rejected-Technical 1281 RAMJIPURAM BASTEPUR RAEBARELI RAEBARELI UTTAR PRADESH 229001 | RAE BARELI | UTTAR PRADESH | 229001 | Rejected-Technical document are not as per requirement |
Tender Value
₹11 L
EMD Value
₹11,000
Closing Date
27 Oct 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE. EDCH,MVVNL
TIPE IV/3, TRANSMISSION STAF COLONY DEVA ROAD, CHINHAT,Lucknow
CONSTRUCTION OF INCREASING CAPACITY OF 33/11 KV S/S AMAWA FROM ASSOCIATED 11 KV OUTGOING FEEDERS, DISTRICT-RAEBARELI
2020_MVVNL_519940_1
11/EWCL/2020-21
Open Tender
Miscellaneous Works
Fixed-rate
90 days
RAEBARELI
As per Tender Documents
2 documents required · 2 mandatory
₹3,540
A/CNo.-0758002100009592,IFCS Code-PUNB0586800
₹11,000
13 Nov 2020
12 Oct 2020
27 Oct 2020
12 Oct 2020
27 Oct 2020
12 Oct 2020
180 days
Amount
Dragging, loading, carriage and unloading of following store material with proper stacking from ESC Raebareli/Other site of MVVNL to JE's dump store and from store to work site.
5 MVA T/F
ACSR Panther Conductor
33 KV Bus Isolator
33 KV Fuse Set
33 KV Post Insulator
33 KV Lightening Arrester
33 KV VCB 800 Amp., 750 MVA
33 KV CT 200/100/1 Amp.
33 KV Single T/F Control Pannel with structure.
11 KV VCB 600/300/5 AMP, 350 MVA Incoming
11 KV VCB 200/100/5 AMP, 350 MVA Outgoing
11 KV 3x300 SQ MM XLPE
11 KV 3x185 SQ MM XLPE
11 KV 3x300 SQ MM XLPE Cable Outdoor
11 KV 3x300 SQ MM XLPE Cable Indoor
11 KV 3x185 SQ MM XLPE Cable Outdoor
11 KV 3x185 SQ MM XLPE Cable Indoor
MS Channel 125x65mm,
MS Angles 50x50x6mm
MS Angles 75x75x8,
MS Angles 75x75x6mm
MS Round Bar of 32 mm dia for earthmat
Rail Pcs of 90 Lbs 3.46M long 2 No. Pcs 6.92M @ 44.61 Kg./M
ST Pole 11 Mtr
V-type cross arm 65x65x6 mm,
MS Channel 100x50x2028 mm (Dropper for Fuse Set)
MS Channel 100x50x2240m Top Channel
MS Angle 40x40x5 mm (3.0 Kg/Mtr)
M.S. Angle Iron 65x65x6mm, 2700 mm long
Polymeric Disc Insulator T & C type 4500 Kg.
11 KV Disc fitting T & C type 4500 Kg.
Polymeric11 KV Pin Insulator with Pin
MS Channel 100x50x2028m for TPMO
Earthing of pole by MS Earthing rod 20x2500 mm & 6 SWG earthing wire etc Complete
MS Angle 65x65x6mm 2028 mm Mtr long for cable hoisting support
Stay (GI Stay rod 16x1800 mm, Stay 7/10 SWG 5 Kg.)
GI wire 8 SWG for guarding along/across the line
Guarding Angle 65x65x6mm (2500/1600 mm long)
ACSR Rabbit Conductor
Earth Mat: Laying of Earth mat in the switchyard by laying of MS Round Bar of 32 mm dia in (from 500mm to 750mm as per site) deep trenches with MS Round bar 32 mm dia, 3 mtr. Long earth electrodes as per drawing. The work includes welding of the MS Round, connecting all steel structures in the switchyard with the earth mat by means of GI Strip of size 50x6mm as per item below ( MS Round bar 32mm to be provided by deptt.) as per RES. No.-43.
Excavation of earth for laying mat
Driving of earth electrodes
Laying of earth mat MS Bar including cutting, shaping and binding etc.
Preparation of joints, proper making and welding of main earthmat bar joints and applying bitumen impregnated on joints i.e. end joints, Cross Joints, Lap Joints etc.
Welding of Riser Strip with earth mat and structure body. One set means one Riser Strip welding to main equipments.
Plinth of 5 MVA 33/11KV T/F: Construction of plinth of size 3.46 x4.46 Mtr. For 5MVA T/F suitable for 10 MVA T/F having 0.4 Mtr. above ground level. The work includes excavation of foundation, base concretion of CC 1:4:8 ratio (cement, fine sand & brick ballast) first class brick work in cement morter of rtio1:4 foundation CC in 1:4:8 ratio(cement, find sand & brick ballast) and RCC work in ratio 1:2:4 (cement, coarse sand and stone grit of 20mm gauge using MS bar of 10mm dia(tor) in reinforcement including its cutting, bending & binding in required shape. The work also includes laying of 2 No. 3.46 mtr. long rail pieces complete with cutting, welding & proper fitting etc. The plinth will be made as per drawing and shall be plastered/ finished on top and sides of the plinth (Rail pieces provided by department).
Fabrication, Errection & Grouting of Substation Structure: (a) Isolator Structure: Fabrication of Isolator Structure 3.5 mtr in height as per Drg.No.RES-39 digging of two no. pits of size 1.075x0.9x0.3 mtr. providing Stone Pad at the bottom of the pit and grouting of two legs of the isolator structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the isolator structure shall be properly finished with smoothing of edges. (MS Channel/Angles to be provided by the department).
Lightening Arrestor, P.I. ,Fuse Set & CT Structure: Fabrication of structure 3.5 mtr. in height as per Drg. No. RES-39, digging of two no pits of size 1.075x0.9x0.3 mtr. providing stone pad at the bottom of the pit and grouting of two legs of the Structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the structure shall be properly finished with smoothing of edges. (MS Channel/Angles to be provided by the department).
Plinth of VCB : Construction of Plinth of size 2.0 mtrx1.5mtrx0.9mtr. suitable for erection of upper structure of 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:3:6 (cement, find sand & brick ballast) 1st class brick work in cement mortor ratio 1:4:8 (cement, coarse sand and stone grit of 20mm gauge).
Erection and installation of 33/11KV 5MVA T/F : Erection and installation of 33/11KV 5 MVA T/F in a levelled position of the plinth. The work includes shifting of T/F to the site and above installation within the S/s premises, assembling, fixing and fitting of all accessories and filling of T/F oil to the desired level and ensuring that there is no leakage. All proper jumpering, connection, testing & commissioning of 33/11 KV T/F are included in the scope of work.
Earthing for power T/F by way of boaring and lowering of 40mm dia, 2.5 mm thick GI Pipe from ground upto the water level (minimum 30 Mtr deep) as per standard practice as per REC Drg. No.-41
Fabrication and grouting (1:4:8) of MS Angle 75x75x6 mm in L Shape & in proper size and alignment to provide support for the two separate earthing strips (50x6)mm size for power transformer neutral including supply & fixing of two no. flexible copper bonds for neutral earthing as per Drg. No.-41.
Fabrication and erection of cable support made of two pieces of MS channel 100x50mm, 3.0 mtr. long joined to each other by means of 5 no. MS Fat 50x6mm pieces of size 150mm long each by welding at equal intervals as per drawing and grouting in block of size 300x300x700mm (1:4:8) complete with one coat of ready mixed primer and two coats of Al. Paint. This includes providing of four no. MS Clamp made of MS Flat holding the cable including nuts & bolts and fixing of XLPE cable.
Installation of Isolators: Assembling and installation of line/ bus isolator on the isolator structure adjusting of opening mechanis in proper alignment so as to ensure smooth operation of the same. In case of line isolator proper operation of earth links shall also be ensured. The work includes fabrication & proper connection with earthmat by erth strip 50x6mm for proper flexing if required.
Installation of Lightening Arrestors : Assembling, installation & mounting of 3 No.(1set) L.A. on the L.A Structure/complete with making earth connections (separate) and line connections. The work includes fabrication for fixing if required.
Installation of P.I. : Assembling, installation & mounting of 1 set P.I. on the P.I. Structure/complete. The work includes fabrication for fixing if required.
Installation of CT: Installation of 3 No.(1 set) CT on the CT Structure alongwith CT J/B. The work includes fabrication for proper fixing if required with proper commissioning & testing.
Installation of Fuse : Installation of 3 Nos.(1 set) Fuse on the / Fuse structure . The work includes fabrication for proper fixing if required
Installation of VCB: Installation of 33KV VCB complete work including commissioning & testing.
Installation of Switchgears in Control Room: Shifting carefully & safely 11KV I/C & O/G switchgears from outside of the switchgear room, including grouting the two no. 100x50x6mm channel pieces (each 800 mm long including cutting to size) and foundation bolts in 1:2:4 CC(including cutting of CC of the floor and finishing of floor) as per direction of Engineer incharge, placing and fixing of switchgear on foundation providing G.I. Nuts & of proper size in proper position and alignment and checking, complete work with mounting of P.T. incoming S/G with proper testing & commissioning of switchgear.
Fixing and making Bus Bar connections in between all switchgears after cleaning and tapping with H.T. Tape, empire tape and PVC tape properly, providing and fixing of 6 mm thick Bakelite separators and plugging of all opening & holes with plastic compound complete work as per satisfaction of site incharge.
Shifting carefully and installation of 33KV Single circuit transformer control panel in control room including grouting of above as per testing & commisioning satisfaction of site incharge.
Earthing of 11KV & 33KV Switchgears: Laying of Earth mat for earthing of indoor equipments by means of GI Strip 50x6mm connecting to Pipe type earthing as per RESSPO norms. Joints will be welded with high quality arc welding.
Providing and fixing of 24 Volt Battery and battery Charger Complete.
Supply & Fixing of Rubber matt size 8/10 mm 2x4 Mtr.
HT Cable Laying : Laying & dressing of 11KV 3x300 Sq.mm XLPE cable from 5 MVA T/F to 11KV incoming Switchgear by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below and above the cable. The cable shall be duly protected by bricks, sand & stone slab. The work includes supplying of fine sand, bricks and stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable.
Layng & dressing of 11KV 3x185 Sq.mm XLPE cable from 11 KV outgoing Switchgear to 11 KV outgoing feeder double pole by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand & stone slab. The work includes supplying of fine sand, bricks and stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable.
Hoisting of 11KV Cable with 100 mm dia 3.5Mtr. long GI Pipe on the feeder cable before mounting the cable on the double pole, lifting, mounting and clamping of 11KV feeder cable boxes on the feeder double pole structure and making connection including supply of cable mounting clamps. The work includes the sealing of GI Pipes, lower end of the pipe is to be buried into the earth by about one foot. (GI Pipe, necessary clamp, nut & bolts etc to be provided by contractor.)
Hoisting of 11KV Cable to 11 KV switchgear & 33/11KV T/F.
Making of all connnection with the help of ACSR Dog/Panther Conductor and clamp of the Transformer bay.
Construction of Cable trench of size 300x300mm including brick work 1:4 in wall of the trench, brick ballast work in 1:5:10 on foundation plaster 12mm thick with coarse sand 1:4 and surface finishing with cement, providing MS Strip at an interval of 0.5 Mt. and MS Angle (25x25x5mm) running on both the edges of trench.
Construction of welded frame type control cable trench cover 0.5 Mt. long suitable for trench including cost of MS/Tor Bar.
Supply and laying of following size Copper Control Cable through underground/cable trench/trenching SGR interlinking through proper connections to T/F Control panel/protection board/Battery and Battery Charger/Bunch joints, Relay 33/11KV T/F junction Box/33KV VCB, CTs etc. as per site conditions:
2x2.5 Sq.mm
4x2.5 Sq.mm
6x2.5 Sq.mm
Control Cable Trey
Painting of all structures and equipments.
Providing and Fixing of Single Core PVC Cable, 1x630 sq.mm. & fixing between Transformer incoming 3x300 Sq.mm XLPE Cable and Transformer 11 KV/LV Side Bushing connector for reducing of tension at LV Side Bushing.
Dismentaling of Old existing Structures/ Equipments safely.
Carriage of old damage, unused Scrap material from site to Electy. Store Raebareli.
Construction of 11 KV feeders: (a) Excavation of foundation pit in mix soil/normal soil, soft & hard rock and its back filling and levelling etc. The size of the pit will be 800x900 mm and having a depth of 1/6 of the full length of the support. Erection of supports by providing stone pad, fixing all clamps and other accessories such as No. Plate, Danger Board, Barbed Wire (2Kg.), Painting etc. as per relevant drawing RESPO RES-6. This includes any fabrication, if required. (b) Grouting of above supports with cement, concrete (CC will be of cement coarse sand & brick ballast) Grouting will be done with the help of wooden/steel formers in a block of size 450 mm x 450 mm x 1/6 of the full length of the support in the CC 1:4:8 ratio as per RES-6 drawing including back filling and proper ramming. (c) Making of plinth of STP 300 mm, dia & 300 mm above ground level in CC of 1:4:8 & plastering of the same with 12 mm thick plaster of cement & sand in 1:4 ratio. (d) Earthing of supports with Earth Electrode 2.5 mtr. length including excavation of pit and driving M.S. Rod upto proper depth and connecting the earth electrode with the help of 6 SWG G.I. Wire and earthing lugs. RESPO RES-12 (MS rod and 6SWG GI Wire provided by department).
For Single Support 11Mtr. STP
For Section Double Pole 11 mtr. STP
For Single Sectional Support 11 mtr STP
For End Type Cable exposer Double pole 11 mtr STP for outgoing feeder including 11 KV TPMO, 11 KV Fuse set with necessery fixing clamp etc. with nut & bolts. (11 KV TPMO, 11 KV Fuse set with clamp, nut & bolt to be provided by contractor).
Grouting of stay roads 16x1800 mm including all works of excavation grouting by, cement concrete in size 0.60x0.60x0.3 mtr. with ratio 1:4:8 as per relevant drawing including back filling of earth and proper ramming. Fixing, tightening & nuzzling of stay with the poles and required tension as per drawing No.-RES-25
Laying, spreading, lifting, Stinging, jointing and final sagging of ACSR Rabbit Conductor in accordance with profiles and sag chart including binding, jumpering and fixing of all accessories in 3 nos. conductor in parallel with PG Clamp binding wire etc requested for job.
Guarding between two poles like single/double/Tri./Four Poles etc. to guardLT/11 KV/Telephone lines, Road/River Crossing etc. with G.I. Wire 6 SWG and G.I. Wire 8 SWG including fixing of guarding channel of requested site with clamps and nuts and bolts as per drawing RES-51.
Looping of branches of trees along the route of Line and disposal of the same after obtaining permission of competant Authority.
A. A. ENGINEERING CO.
KHUSHI ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .