Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹36.1 L+₹3.7 L (11.3%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹36.5 L+₹4.0 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹36.6 L+₹4.1 L (12.7%)Rejected-Finance 27 ABUSETH ROAD DEHU ROAD PUNE 412 101 | NA | NA | 412101 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹36.7 L+₹4.2 L (13.1%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
9 Sept 2020, 6:00 pmClosed
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim 737102
Repair maint of sewage line septic tank manhole and cleaning work including repair to drain protective works etc in old cantt under GE Gangtok
2020_MES_353672_5
8857
Open Tender
Miscellaneous Works
Item Rate
365 days
GE Gangtok
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹66,000
Yes
17 Sept 2020
2 Sept 2020
11 Sept 2020
2 Sept 2020
9 Sept 2020
3 Sept 2020
Amount
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out as in soft/loose soil for foundation etc. Complete all as directed by the Engr-in-Charge.
All as per item no 1 but for each additional 1.5m or part thereof in depth beyond the first 1.50 m complete all as directed.
Excavation over areas,n.exc 1.5m deep and getting out in soft/loose soil complete all as directed.
All as per item no 3 but for each additional 1.5m or part thereof in depth beyond the first 1.50 m complete all as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in thick as in Soft/Loose Soils complete all as directed by the Engr-in-Charge.
Removing surplus soils to a distance not exceeding 50 mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point complete all as directed by the Engr-in-Charge.
Demolition of precast block masonry or precast concrete article built in cement mortar complete all as specified and as directed.
Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillare, etc but exclusing ashlar facings, dressed stones work and precast concrete articles complete all as directed.
Demolition of reinforced cement concrete of any description and in any position such as pre-cast manhole cover or cover slab of septic tanks etc (reinforcement cut as required to facilitate demolition) complete all s directed by the Engr-in-Charge.
Demolition / Dismantling and breaking up of drain pipes (AC or PVC or SWR) 110MM bore (Internal), set in cement mortar all as directed by the Engr-in-Charge.
Demolition /Dismantling and breaking up of drain pipes (Salt glaze stone ware or reinforced cement concrete) 150mm bore (Internal), set in cement mortar including taking out from trenches and removing from site all as directed by the Engr-in-Charge.
Demolition of cement concrete (un-reinforced) of any description and in any position not specifically provided for complete all as directed by the Engr-in-Charge.
Taking down rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends,swan necks etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by the Engr-in-Charge.
Taking down cement plaster on brick or stone walls or concrete surface, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by the Engr - in- Charge.
Material & labour for precast PCC 1:3;6 type C1 (by using 20mm graded stone aggregate) block masinry with solid blocks, exc 10cm in width and setting in CM 1:6 complete all as directed by the Engr -in- Charge.
Material & labour for precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) s in manhole covers etc including necessary form work and set in CM 1:4 complete all as specified and as directed. NOTE : Reinforecement shall be measured and paid separately
Material & labour for RCC (1:2:4), type B- 1 (using 20mm graded stone aggregate) (nominal mix) as in cover slab of septic tank, slabs supported on walls, beams &columns etc complete all as specified and as directed.
M&L for use and waste of form work to soffits of suspended slab such as cover slab, rrof slabs, floor slabs, landing and similar works exceeding 200mm thick for flat fair finished surfaces of concerete complete all as specified and as directed.
Material & labour for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for colimns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. complete all as specified & as directed.
Material & labour for Mild Steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & as directed.
Material & labour for PCC (1:3:6), type C-2 (using 40mm graded stone aggregate ) as in foundations, filling and mass concrete complete all as specified & as directed.
Material & labour for PCC (1:3:6) type C-1 (using 20mm graded stone aggrgate ) as in coping including necessary form work complete all as specified & as directed.
Labour only for stone walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) including brought up to courses complete all as specified and as directed by the Engr-in-Charge.
All as per item No 23 here-in-before but except stone. NOTE : Stone buolders obtained from item No 8 here-in-before shall be re-used.
M&L for hand packing (any thickness) at back of retaining wall with broken stone or boulders and raising (or lowering) to required level complete,all as specified. NOTE :- Stone boulders obtained from item No 8 here - in - before shall be re-used.
Material & labour for rendering 15mm thick in CM (1:3) with using water proofing compound @ of 3% by weight of cement on fair faces of birck or concrete surfaces, finished even & fair with using extra cement complete all as specified and as directed.
Material & labour for rendering 15mm thick in CM (1:4) on other than fair faces of brick or concrete surfaces, finished even & fair with using extra cement complete all as directed.
M & L for PCC 1;3:6 type C-2 9by using 40mm graded stone aggregate) as cin bed to drain pipes 150mm bore,including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed by the Engr-in-Charge.
M & L ofr PCC 1;3:6 type C-2 (by using 40mm graded stone aggregate) as in bed to drain pipes 100mmbore, including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed by the Engr-in-Charge.
Material & labour for cutting into existing manholes for connecting new drains (internal dia pipe 150mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 sectrion ) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching all as directed by the Engr-in-Charge.
Material & labour for cutting into existing manholes for connecting new drains (internal dia pipe 100mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching all as directed by the Engr-in-Charge.
Cleaning of blocked sewage line 150mm bore by rodding with using sectional sewer rod / flexible sewer rod / steel rod or split bamboo stick throughly from both sides between adjacent manholes / inspection chamber to manholes of any depth and size including well flushing with water till clear flow of sewage line is observed including taking out sludge & other foreign particles from manhole & pipe lines and buried in earth pits and spreading and including of bleaching powder & 1kg/sqm over the sludge before filling of earth in layer of 30 cm complete all as specified and to the entire satisfaction of Engr-in-Charge.
All as per ser item No 32 above but sewage line of 100/110mm bore. Notes for Ser item No 32 & 33 (i) Length from manhole to manholes shall be measured in these item. (ii) Cleaning of sewage line to be started from down stram side, in this operation some pipe line will be cleaned automatically and need not be cleaned by rodding and the same shall not be measured for payment. (iii) The unit rate of the item shall be deemed to include the removal of sludge / waste water accumulated in manhole / inspection chamber due to cleaning of drain by rodding. (iv) Water required for cleaning the sewage line are the responsibility of the contractor and no extra payments will be made in this regard. (v) Cost of bleaching powder and lime deemed to be include in unit.
Cleaning of septic tank. Soakage well of any size by removing of sludge from inside the septic tank and removing to a distnace exc.250m but not exc.500m and buried the same in to earth pits including excavation of earth pits of required size & depth, depositing & spreading of sludge, returning in filling earth over sludge with and including bleaching powder @ 1 kg/sqm and removal of surplus soil to a distance not exc. 50m all complete as specified and as directed. NOTE : Earth to be filled over the pit over bamboo matting after sufficient absorption of liquid for a period of 48 hours and spreading of bleaching powder over the sludge before earth filling as directed by the Engr -n - Charge. Cost of bamboo matting,spreading of bleaching powder and excavating the earth pit and filling earth etc shall be include in the unit rate as quoted and size of pit shall be made accordingly as directed by the Engr-in-Charge. The measurement of sludge shall be taken as per size of earth pit with actual depth of sludge deposited in the earth pit after initial settlement of 48 hours.
Cleaning of blocked gully trap/floor trap etc of any size by rodding thoroughly to manhole and well flushing with water after cleaning and including remove of sludge and other materials obtained from cleaning, garbage to a pit made for this purpose and filling up to the earth complete all as specified and as directed.
Cleaning of blockages of WHB, EWC etc of any size by rodding thoroughly to manhole and well flushing with water after cleaning and including remove of sludge and other materials obtained from cleaning, garbage to a pit made for this purpose and filling up to the earth complete all as specified and as directed.
Cleaning of blocked man holes up to 60cm depth by removing of sludge from inside and removing to a distance exc 200m but not exc.500m and buried the same in to earth pits including excavation of earth pits of required size & depth, deposting & spreading of sludge, returning in filling earth over sludge and removal of surplus siol to a distance not exc.50m complete all as specified and as directed.
All as per item No 37 above but exc 0.60 metre but n. Exc 1.50 metre in deep.
All as per item No 37 above but exc 1.50 metre but n exc.3.0 metre in deep. Notes for Ser item 37 to 39 (i) The unit rate of the item shall be deemed to include the remival of sludge / waste water accumulated in manhole / septic tank / soakage chamber. (ii) Water required for cleaning the sewage line are the responsibility of the contractor and no extra payment wii be made in this regard. (iii) Cost of bleaching powder and lime deemed to be include in unit rate.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing servicable tiles to store and rubbish off the premises all as directed by the Engr-in-Charge.
Material & labour for non- skid Ceramic plain coloured tiles 7 to 8 mm thick (square / rectangular) conforming to IS 13712 grade B-II (a), approved make and colour shade, area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including screed bed or bedding layer 15mm thick in CM 1:4 complete all as specified.
Material & labour for glazed ceramic coloured tiles of size 300 x 200 mm x7 mm thick fixed on vertical surfaces such as dado /skirting, raiser to steps etc conformig to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including screed bed /backing layer of 10mm thick in cement mortar (1:3) complete all as specified & as directed.
Material and labour for Lacquer coated precast chequered cement concrete tiles made with grey cement and pigment of size 300 x 300 x 25 mm thick as in pavement / footpath, set and jointed in neat cement slurry and pointed with cement laid over and including screed bed/ bedding layer of 15mm thick in cement mortar (1:4) complete all as directd.
Supply & fix as in repair 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet,ball valve, float,handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete (excluding PVC connection pipe) as directed by the Engineer-in-Charge. Make : Hindware Model SLEEK ESSENCE DUAL FLUSH or equivalent approved.
Supply and fix in repair white vitreous china wash down water closet pan (pedestal pattern) EWC,of size 57 0x 460 x 380 mm with 'P' or 'S' trap,including fixing bolts, plastic water closet seat cover, closed pattern with flat bottom, and mild steel chromium plated or aluminum anodised hinging device, making all necessary connections and making good the disturbed surfaces of floor complete all as specified and as directed. Make Hindware Cat No. 20012 or equivalent approved make.
Supply and fix in repair white vitreous china squatting pan of 'ORISSA Pattern' , of size 580mm x 440mm (white) with intergal fot rest 'P' OR 'S' trap, front or back inlet, any pattern (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphon pipe etc complete including provision of PCC bedding and connection to trap, and to flushing pipe, antisyphonage pipe, etc.complete including making good to floor all as specified and directed by the Engr-in-Charge. Make :Hindware Cat No. 20042 or equivalent approved make.
Supply and fix in repairs vitreous china,white colour,flat back, wash hand basin of size 55 x 40 x79cm fixed with brackets, including providing 32mm dia PVC waste pipe,32mm bore CP waste coupling and making all necessary connections complete as directed. Make : ESSCO Cat Part No.ECS-WHT-803 or equivalent approved.
Supply and fix in repairs vitreous China (white) flat back urinal of size 465 x 265 mm, including providing and fixing plugs, bedding the urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing grating and union for discharge pipe including 32mm bore PVC discharge pipe complete all as specified and as directed. Make : Cera Cat No. 5001 or equivalent approved.
S&F as in repair 15mm bore pillar taps,cast copper alloy, with capstan heads, chromium plated screwed down high pressure with or without lettered ''Hot or Cold'' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed. Make : Continental series of Jaquar Cat No. CON 011KN or equivalent approved make.
S&F as in repair 15mm bore or two way Angular Stop Cocks, cast copper alloy,fancy type, chromium plated, with wall flange complete all as specified and as directed. Make : JAQUAR CODE- CON 059 KN or equivalent approved make.
Supply & fix fix in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. Make :Prayag Cat No. 323 or equivalent approved make.
S&F as in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
S&F chromium plated health faucet 8mm dia alongwith 1m flexible tube and wall hook fixed in position complete all as specified and as directed. Make : Cera F8030103 or equivalent approved make.
S&F wall mounted hot and cold water mixer with connecting lugs and wall flanges, cast copper alloy, chromium plated complete all as specfied and as directed. Make : Marc ES-520 or equivalent approved make.
S&F as in repair 110mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in flooor with all necessary clamps, bolts, bends, Tee etc complete all as specified and as directed.
Supply & fix in repair 150mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in floor with all necessary clamps, bolts, bends, Tee etc complete all as specified and as directed.
S&F for reinforced concrete pipes, class NP2, laid and jointed complete with collars of 300mm bore complete all as specified and as directed.
S&F for reinforced concrete pipes, class NP2, laid and jointed complete with collars of 450mm bore complete all as specified and as directed.
S&F for PVC (SWR) 75mm pipes single socketed in any length with rubber ring joints, laid in trenches or in floor with necessary clamps, bolt, bends, Tee complete all as specified and as directed.
S&F in repair 110mm bore PVC(SWR) bends any radius complete all as specified and as directed.
S&F in repair 150mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F 110mm bore PVC(SWR0 vent cowl fixed in position complete all as specified and as directed.
S&F in repairs, CI floor trap 100mm diameter of outlet, with gratings, including jointing to waste pipe fixed in PCC 1:2:4 type B-1 (using 20mm graded stone aggregat0 complete all as specified and as directed.
S&F PVC(SWR) 75mm junction single (Single T) equal or unequal complete all as specified and as directed.
Supply and fix PVC(SWR) 110mm junction single (Single T) equal or unequal complete all as specified and as directed.
S&F PVC(SWR) 75mm bore junction Double (double T) equal or unequal complete all as specified and as directed.
Supply and fix PVC(SWR) 110mm bore junction double (double T) equal or unequal complete all as specified and as directed.
S&F PVC (SWR) 75mm access door complete all as specified and as directed.
S&F PVC(SWR) 100mm access door complete all as specified and as directed.
S&F brass chromium plated trap 'P' or 'S' pattern of 32mm for wash basins and sinks with inlet and outlet, screwed for pipe or connections, and with one cleaning cap and fixed complete all as as specified and as directed.
S&F brass chromium plated trap 'P' or 'S' pattern of 40 mm for wash basins and sinks with inlet and outlet, screwed for pipe or connections, and with one cleaning cap and fixed complete all as as specified and as directed.
Supply only Integral Water Proofing Compound, conforming to IS-2465-2003 and/or as approved, complete all as specified and as directed.
Taking down 15mm dia steel tubing and connections, including cleaning and refixing or removal to store complete all as specified and as directed.
Refixing of old 15mm bore steel tubing and connections in new or old position (wall, ceiling or floor, etc) complete all as specified and as directed.
S&F galvanised steel water tubing 15mm bore, medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as directed.
S&F in repair 15mm bore bib taps cast copper alloy chromium plated, fancy type with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and as directed.
M&L for rendering 15mm thick in CM(1:4) on other than fair faces of stone masonary, finished even & fair with using extra cement complete all as specified and as directed.
M&L for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) 75mm thick in plinth protection/path finished even and fair complete all as specified and as directed.
M&L for plain cement concrete 1:3:6 type C-2 as in plum concrete in retaining walls etc including plums of stone boulders (Basalt, trap or any other approved) of size 200 to 300mm complete all as specified and as directed. Note : Boulder shall be measured and paid separately under item No. 10)
Supply only boulders exceeding 20cm and upto 30cm dia (Basalt, trap or any other approved) of size 200 to 300mm complete all as specified and as directed.
M&L for formwork to faces of walls, retaining walls, abutments, parapets and staircase, railing and similar work including attached pillasters, buttresses etc vertical or to better in rough finished surfaces complete all as specified and as directed.
M&L for RCC(1:2:4), type B1 (using 20mm gradd stone aggregate) as in walls, retaining walls, manhole wall ballast walls and the like any thickness above top of footings including attached pilasters and buttresses etc complete all as specified and as directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc as fair finished complete all as specified and as directed.
Supply only 75mm bore PVC pipe (SWR) single socketed, in any length with rubber ring joints, as in weep holes complete all as specified and as directed.
M&L for 100mm thick PCC 1:2:4 type B2 (using 40mm graded stone aggregate0 as in sub-base of floor etc complete all as specified and as directed.
M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in surface channels/drain including forming fair finihsed to drain channel complete all as specified and as directed.
M&L for extra for forming fair finished drain on channel 30cm inner girth in cement concrete using extra cement including form, moulds, mitred/stopped ends complete all as specified and as directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm complete all as specified and as directed.
S&F in repair 75mm bore PVC(SWR) bends any radius complete all as specified and as directed.
M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and as directed.
M&L for brickwork with sub class 'B' bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete complete all as specified and as directed.
M&L for RCC M-25(using 20mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beam, beams for glumes etc basement slab, under reamed piles & mass concrete complete all as specified and as directed.
M&L for RCC M-25(using 20mm graded stone aggregate) as in columns, pillars, posts & struts complete all as specified and as directed.
M&L for applying three coats of white washing including preparation of new/previously untreated surfaces of ceiling complete all as specified and as directed.
M&L for rendering 5mm thick in cement mortar (1:3) on fair face of concrete surfaces such as ceiling finished surface even and smooth without using extra cement complete all as specified and as directed.
M&L for forming square grooves in plaster n.exc 12mm deep and n.exc 15mm on face complete all as specified and as directed.
M&L for forming letters, figures etc by cutting 'V' grooves in new lime, cement-lime or cement plaster (per cm of height) complete all as specified and as directed.
KAMLESH ENTERPRISE
NISHA CONSTRUCTIONS
STAR CONSTRUCTION
M/S ANIL KUMAR THAKUR
MAHENDRA KHAWAS
DHARMINDER SINGH
BIJAY MITTAL
SHANTI KHAWAS AND SONS
KARMA TSETEN BHUTIA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .