| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹95.9 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹95.9 L Quoted ₹98.8 L | L-1 | Accepted-AOC Being lowest tenderer |
| 2 | L-2₹98.9 L+₹14,778 (0.15%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹98.9 L+₹14,778 (0.15%) | L-2 | Rejected-Finance Not being lowest tenderer |
| 3 | L-3₹1.1 Cr+₹15.3 L (15.5%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹1.1 Cr+₹15.3 L (15.5%) | L-3 | Rejected-Finance Not being lowest tenderer |
| 4 | L-4₹1.2 Cr+₹24.1 L (24.4%)Rejected-Finance | ₹1.2 Cr+₹24.1 L (24.4%) | L-4 | Rejected-Finance Not being lowest tenderer |
| 5 | L-5₹1.2 Cr+₹26.0 L (26.3%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | ₹1.2 Cr+₹26.0 L (26.3%) | L-5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
25 Oct 2024, 6:00 pmClosed
HQ CWE (U) DELHI CANTT-10
HQ CWE (U) DELHI CANTT-10
SPL REPAIR/RENEWAL TO WATER PIPE LINE AT TAURUS ENCLAVE, POLO ROAD, CASSEL ROAD, RDP AREA UNDER GE (U) WATER SUPPLY, DELHI CANTT-10
2024_MES_675679_1
CWE(U)/D-20/2024-25
Open Tender
Civil Works
Works
180 days
HQ CWE (U) DELHI CANTT-10
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE(U) Water Supply, Delhi Cantt -110010
₹2.1 L
Yes
11 Dec 2024
20 Sept 2024
1 Nov 2024
20 Sept 2024
25 Oct 2024
11 Oct 2024
Amount
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as directed.
Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point all as specified and as directed.
Boring holes under road pavement by bocky manually/mechanically in any type of soil upto 200 mm bore. Complete all as specified and directed.
Taking down old unsv cement pipe, joints, bends, elbow, tees, rubber joints upto 100 mm dia complete all as specified and directed.
Taking down old unsv cement pipe, joints, bends, elbow, tees, rubber joints upto 150 mm dia complete all as specified and directed.
Taking down old unsv cement pipe, joints, bends, elbow, tees, rubber joints upto 200 mm dia complete all as specified and directed.
Supplying, laying, jointing, testing and commmisioning of DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including rubber gasket joint (tyton joints) complete all as specified and as directed. Note : - Joints shall be measured and paid separetely
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Material and Labour for CI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 1538-1993 complete all as specified and directed.
Upto 150 mm bore
abobe 150 mm Upto 200 mm bore
Material and Labour for DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 9523 complete all as specified and directed.
Upto 100 mm bore
Upto 150 to 200 mm bore
Material and labour for Run lead joint including jointing material for CI/DI pipe of following size/bore :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of following size/bore :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Taking down old unsv MS pipe, joints, bends, elbow, tees upto 250 mm dia complete all as specified and directed.
Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') not less than 4 mm thick laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header/in trenchless and to connect out going water main CI/DI pipe line complete all as specified and directed. Note:- MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately.
100 mm bore
150 mm bore
200 mm bore
250 mm bore
Supplying and fixing, MS flanges of 100 mm bore not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed.
Supplying and fixing MS flanges of 150 mm bore not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed.
Supplying and fixing MS flanges of 200 mm bore not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed.
Supplying and fixing MS flanges of 250 mm bore not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed.
Material and labour for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of following sizes complete all as specified and directed.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply, fixing, jointing & testing Cast Iron Sluice Valve of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unsv NRV complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv water meter complete all as specified and directed at site. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.
80 mm bore
100 mm bore
150 mm bore
Taking up or down GI tubing and connections of the following sizes from trenches / wall / floor including cleaning for refixing or removal complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Refixing/relaying only GI pipe medium grade with all new fittings fixed complete to walls and ceiling or in floors on old/new position complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supplying & fixing gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778 of following sizes including taking out unsv gate valves complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Labour for cutting of CI /DI/GI pipe in position for reducing to required length for insertion of new tees, branches etc of 80 to 150 mm bore complete all as specified and directed.
Material and labour for fixing of water pressure gauge (0-5 Kg/cm square) 100mm dia size including boring, threading, welding in CI/DI/GI of any sizes and connected with suitable size of 'U' type MS/CP pipe with ON OFF cock all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site all as specified and as directed.
Material and labour for rendering 10 mm thick with cement mortar (1:6) on fair faces of brick work / concrete surfaces, finished the surface even and fair complete all as specified and directed.
Material and labour for GI tubing 'medium grade' with all accessories including bends, elbow, socket, union, nipple etc including taking up or down old unserviceable GI tubing complete all as specified and directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply, installation and testing flanged ends strainer/dirt box of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out old unsv strainer/ dirt box complete all as directed. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.
80 mm bore
100 mm bore
150 mm bore
Supply, fixing, jointing & testing butterfly valve (wafer type) of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, including taking out unsv butterfly valve complete all as specified and as directed. Note:- Jointing material shall deemed to be included in the unit rate of this item.
50 mm bore
80 mm bore
100 mm bore
150 mm bore
Material and labour for excavation in any type of soil through trenchless technology by HDD (Horizontal directional drilling method) including preparing and setting up the plant and equipment. Preparing new pipe work material including all related civil work and mechanical work like excavation, shoring/strutting etc. drilling, stringing, reaming and pulling back the new pipe work on the path alignment proper disposal of drilling fluid and ground penetrating radar survey to protect any exiting utilities at the pipe installation location restoration of site after completion all inclusive as per and STT IS No.2.3.2.2.2.2. second edition 2008 code of practice for trenchless technology suiting Indian condition for making horizontal bore of size 350mm dia suitable for HDPE pipe insertion under road crossing /hard standing including HDPE pipe 250 mm nominal dia of 25 mm min. wall thickness of grade PE 80 for protection of MS/DI pipe to any depth by manually or any means complete all as specified and directed.
Note:- (a) MS Pipe/DI will be measured and paid for separately under respective items. (b) Permission required from civil authority/department prior to executing the work is the responsibility of contractor and the cost for the same shall be deemed to be included in unit rate quoted by the contractor. (c) 250 mm HDPE pipe shall deemed to be included in the unit rate of this item.
Rahul Enterprises (BID ID -3137211)
Ridhi engineers and builders (BID ID -3142865)
Microsys Automation India (BID ID -3142968)
Saini Enterprises (BID ID -3143230)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .