Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | ₹30.5 L Quoted ₹31.2 L | L1 | Accepted-AOC Awarded as first lowest bidder L1 |
| 2 | L2₹39.7 L+₹8.5 L (27.3%)Rejected-AOC GROUND FLOOR 281 1 D SHIVRAI NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | ₹39.7 L+₹8.5 L (27.3%) | L2 | Rejected-AOC Being second lowest bidder |
| 3 | L3₹40.5 L+₹9.3 L (29.9%)Rejected-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | ₹40.5 L+₹9.3 L (29.9%) | L3 | Rejected-AOC Being third lowest bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Requisite documents not submitted |
| 5 | Rejected-Technical NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | - | - | Rejected-Technical Not enlisted in Cat a(ii) |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
20 Mar 2024, 6:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIRS TO VARIOUS UTILITY SERVICES INCLUDING INTERNAL AND EXTERNAL ELECTRIFICATION SUMMER COOLING WINTER APPLIANCES AND EXTERNAL WATER SUPPLY SERVICES AT GANESHKHIND PUNE
2024_MES_638263_2
GERD/PSN/TOKEN/59 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
GERD PASHAN PUNE
₹70,000
Yes
30 May 2024
7 Mar 2024
22 Mar 2024
7 Mar 2024
20 Mar 2024
15 Mar 2024
7 Mar 2024 - 14 Mar 2024
Amount
Taking down carefully Copper/ aluminium point wiring (light, Fan, Exaust Fan, Bell, socket or power point) complete including fixture & fitting such as switches, sockets, power socket, bell, bell push, light fittings, regulator, bracket holder and making good disturbed surfaces of wall and ceiling etc. complete all as specified and directed.
Taking down carefully unserviceable sub main wiring any size and type including conduit/casing patti etc complete all as specified and directed.
Taking down unserviceable DBs any type / size including MCB and MCCBs by carefully disconnecting and making good disturbed surfaces complete all as directed.
Material and labour for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through in existing concealed / surface PVC/Steel conduit and accessories and replace laminated sheet 3mm thick on existing MS pressed steel terminal box for mounting of switches, socket regulator etc including 1.5 Sqmm PVC insulated unsheathed cable multistranded copper conductor and connecting to earth dolly for the following complete all as directed and specified by Engr-in-charge. (a) One light point controlled by one 5 Amps one way switch.
(b) One light point controlled by two Two way switch
(c) One ceiling Fan/ Exhaust Fan point controlled by one 5 Amps switch.
(d) One bell/buzzer point controlled by one bell push button on independent board.
(e) One 3 Pin 6 Amps socket point on the independent board.
(f) One 3 pin 6 Amp socket point on the same board alongwith other switch.
All as per item No-4 here-in-before but with 2.5 Sqmm cable for 15 Amp switch socket out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all as directed and specified by Engr-in-charge.
Material and labour for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through and including PVC casing & caping of suitable size including necessary tees, Junctions, bends etc fixing on wall/ roof and PVC switch board (or) hylam sheet of 3mm thick in existing MS Sunken board of suitable size for mounting of switches, sockets regulators etc including 1.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor and connecting to earth dolly for the following complete all as directed and specified by Engr-in-charge. (a) One light point controlled by one 5 Amps one way switch.
(b) One light point controlled by two way switch
(c) One ceiling Fan/ Exhaust Fan point controlled by one 5 Amps switch.
(d ) One bell/buzzer point controlled by one bell push button on independent board.
(e) One 3 Pin 6 Amps socket point on the independent board.
(f) One 3 pin 6 Amp socket point on the same board alongwith other switch.
All as per above item No-11 but with 2.5 Sqmm cable for 15 Amp switch socket out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all as directed and specified by Engr-in-charge.
Supply and fixing switch piano flush button type , singlepole one way 5 Amps complete all as specified and directed.
Supply and fixing Socket 2 in one 5 Amp complete all as specified and directed.
Supply and fixing switch piano flush button type , single pole two way 5 Amps complete all as directed.
Supply and fixing Bell push flush type SP 5 Amps complete all as specified and directed.
Supply and fixing switch socket combination out let 5 pin 6 Amps flush type complete all as specified and directed.
Supply and fixing switch socket out let 2 in 1, 3 pin 5 and 16 Amps flush type Universal complete all as specified and directed.
Supply and fixing of ceiling rose ,3 phase ,PVC polycarbonate ,insulated body complete all as specified and directed.
Supply and fix stepped type elctronic fan regulator 240 V 50 HZ , flush type complete including connection complete all as specified and directed.
Supply and fix call bell (Ding Dong) 240 V, 50 Hz complete all as specified and directed.
Supply and fixing LED tube light fittings 1x 20W, 220V, AC polycarbonate housing & integreated electronic driver type including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose at any height complete all as specified and directed.
Supply and fixing 2'x2' LED ultra modern slim recess armstrong/grid ceiling light fitting 1x36W including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose at any height complete all as specified and directed.
Supply and fixing LED tube light fitting 10W, 2 feet long wall mounted polycarbonate housing interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessories including suitable lamp, internally prewired & including connecting up with twin core twisted flexible copper cable of suitable size all as specified and as directed.
Supply and fix 10 W LED bulk head fitting environmental friendly, ultra modern, energy saving surface mounted fitting complete with all accessories incl twin core twisted flexible copper cable of suitable size Complete all as specified and as directed.
Supply and fixing LED glaze wall decorative light fitting environmental friendly, ultra modern, energy saving wall mounted fitting alongwith 10W LED bulb complete with all accessories including twin core twisted flexible copper cable of suitable size all as specified and as directed.
Supply and fixing LED security light fitting 25 watt with pressure dia cast housing, prismatic, polycarbonate diffuser and IP65 protection including 0.6 mtr long 20/25 mm (as per manufacturer standard) dia GI Pipe in 45 degree bend shape and necessary clamping devices required at site complete all as specified and directed by Engr-in-Charge.
Material and labour for Sub main wiring complete with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through including PVC casing capping of suitable size and including 1 run of 2.5 Sqmm PVC insulated unsheathed copper conducter with multistranded copper conductor as earth continuity complete all as specified and directed. Note : Two runs of copper conductor and one run of earth copper conductor and one run of casing capping shall be measured as one length.
Material and labour for Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through including PVC casing capping of suitable size and including 1 run of 4 Sqmm PVC insulated unsheathed copper conducter with multistranded copper conductor as earth continuity. Note : Two runs of copper conductor and one run of earth copper conductor and one run of casing capping shall be measured as one length.
Material and labour for Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through including PVC casing capping of suitable size and including 1 run of 6 Sqmm PVC insulated unsheathed copper conducter with multistranded copper conductor as earth continuity complete all as specified and directed. Note : Two runs of copper conductor and one run of earth copper conductor and one run of casing capping shall be measured as one length.
Material and labour for Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through in existing PVC/Steel conduit and including 1 run of 4 Sqmm PVC insulated unsheathed copper conductor with multistranded copper conductor as earth continuity complete all as specified and directed. Note : Two runs of copper conductor and one run of earth copper conductor shall be measured as one length.
Material and labour for Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through in existing concealed PVC/Steel conduit and including 1 run of 6 Sqmm PVC insulated unsheathed copper conductor with multistranded copper conductor as earth continuity complete all as specified and directed. Note : Two runs of copper conductor and one run of earth copper conductor shall be measured as one length.
Supply and fix in repair TPN DB suitable for Mounting MCB as Incomer of rating 63 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection, double door including connection with aluminium thimbles as required complete all as specified and directed.
Supply and fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 8 way with IP-43 IK-09 protection with metal door complete with appropriate size bus bar and neutral link,all as specified.
Material and labour for MCCB 4 pole, 415 volts,TMA type, 63 amps with breaking capacity 16KA and fixed board including spider link electrical connection as per site requirment complete all as specified and as directed.
Supply and fix MCB SPN 20-40 Amps 6 KA, 240 V connected through copper thimbles of suitable size complete all as specified and directed.
Supply and fix MCB SP 6-32 Amps 6 KA, 240 V connected through copper thimbles of suitable size complete all as directed and specified.
Supply and fix MCB TPN 63 Amps 10 KA, 240 V connected through copper thimbles of suitable size complete all as directed and specified.
Material and labour for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 Metre below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 (Use 20mm graded stone aggregate) chamber with RCC 1:2:4 type B1 (Use 20mm graded stone aggregate) in cover slab GI funnel with GI watering pipe 20mm dia medium grade, wire mesh, protection pipe 20mm dia GI pipe light grade for earth lead upto 7.50 metre long salt, charcoal complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 Metre below normal ground level connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 (Use 20mm graded stone aggregate) chamber with RCC 1:2:4 type B1 (Use 20mm graded stone aggregate) in cover slab GI funnel with GI watering pipe 20mm dia medium grade, wire mesh, protection pipe 20mm dia GI pipe light grade for earth lead upto 7.50 metre long salt, charcoal complete all as specified and directed by Engineer-in-Charge.
Taking down carefully after disconnecting electrical/water supply connections and transporting to the work shop for carry out the servicing / over hauling of the storage type electric water heaters (Geysers) of capacity 25 / 50 litres of any make / type by cleaing the inner surface of the tank / heating element with chemical to remove the scaling / rust & reassembling the same after replacing burnt out parts and refixing on its original position including testing complete all as directed.
Supply and fix in repair heating element of the following ratings as required at site including rubber washer/packing complete all as specified and directed. (a) 1/1.5 KW
Supply and fix in repair thermostat as per existing type suitable for geysers 25 / 50 litres, ISI marked complete all as specified and directed.
Supply and fix in repair 15mm steel hot water pipe with two brass adopters 18" long and fixing in position for hot water outlet connections complete all as specified and directed.
Supply an fix in repair PVC connection with two brass adaptors 18" long & fixing in position for cold water inlet connection complete all as specified and directed
Supply and fix in repair Gunmetal stop cock ISI marked 15mm dia & connecting up in position complete all as specified and directed.
Supply and fix in repair Gun metal Non-Return valve 15mm dia complete all as specified and directed
Supply and fix in repair indicator lamp rectangular / round type suitable for 25 litres geysers complete all as specified and directed
Supply and fix in repair pressure release valve 15mm dia complete all as specified and directed
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically & mechanically, dismantling, examine and transporting to the work shop & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete. Note : (i) Rewinding of fan shall be measured and paid seperately. (ii) Spare parts of ceiling fan shall be measured and paid seperately as supply only.
Material and labour for Re-winding of ceiling fan any sweep with same guage supper enameled copper wire to maintain speed at load complete all as specified and directed.
Material and labour for painting of ceiling fan any sweep taken down vide item No 56 by applying one coat of synthetic enamel paint after preparation of surface complete all as specified and directed
Supply only ball bearings for exhaust/ceiling fan of any sweep complete all as specified and directed. Make : SKF/NBC/FAG
Supply only GUN METAL BUSH for exhaust / ceiling fan of any sweep complete all as specified and directed.
Supply and fix in repairs fan condenser of following sizes :- (a) 2.5 mfd
(b) 4 to 6 mfd, Make : Asian/ EPCOS
Supply only rubber reel, nut bolts, washer, split pin complete set all as specified and directed.
Supply only Fan connector suitable for wire connection complete all as specified and directed.
Supply only canopy suitable for 1200mm ceiling fan complete all as specified and directed.
Taking down the repairable exhaust fan of 250 MM to 300 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value. Note : (i) Rewinding of fan shall be measured and paid seperately. (ii) Spare parts of ceiling fan shall be measured and paid seperately as supply only
(b) Material and labour for re-winding of exhaust fan 250 MM to 300 MM sweep, any make, taken down vide item No 66 with same guage supper enameled copper wire to maintain speed at load, complete all as specified and directed.
All as per above item No- 66 but exhaust fan 300 to 450mm sweep. (a) Servicing/overhauling the exhaust fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation resistance value. Note : (i) Rewinding of fan shall be measured and paid seperately. (ii) Spare parts of ceiling fan shall be measured and paid seperately as supply only
(b) Re-winding of exhaust fan 300 to 450 mm sweep, any make, taking down vide item No 68 with same guage supper enameled copper wire to maintain speed at load, complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc ,inlcuding making Electrical / Water supply connection and additions / Alterations to Existing Brackets, testing and taking down old unsericeable heater and depositing to MES store complete all as specified and directed.
Taking down the existing un-serviceable exhaust fan of any sweep including deposited to MES store and Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
Taking down the existing un-serviceable exhaust fan of any sweep including deposited to MES store and Supply and fixing PVC exhaust fan 250 mm sweep,single phase 230 volts, 50 Hz complete with copper wire for connection complete all as specified and directed.
Taking down the existing un-serviceable ceiling fan of any sweep deposited to MES store and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with new copper connection wires complete all as specified and directed.
Supply and fix PVC insulated and PVC sheated 3 core copper cable (P+E+N) of 2.5 Sqmm copper conductor complete all as specified and directed. Note : 3 runs of cable shall be measured in one unit length
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-40Amp, accuracy class-I 50Hz, conforming to IS13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including taking down of old meter and depositing to MES store complete all as specified and directed. Make : L&T/ Elmeasure/ Enercon
Supply and fix Rigid non-metallic PVC conduit 20mm medium grade inclusive of necessary tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
On load filteration of transformer oil by continueous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap complete all as specified. Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration.
Supply and topping up transformer oil of dielectric strength 60 KV at 2.5 mm gap in transformers of various capacity installed in various locations complete all as specified and directed. Notes : (a) New Transformer oil shall be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
Supply and fix in repair breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer complete all as specified and directed. Note : Rate quoted shall be deemed to include the cost of modification if any required to fix on existing MS Pipe.
Repair to gang operated air brake switch device upto 100 Amps,22 KV capacity including greasing/oiling of all moving contacts, renewal of nut bolts,washers of suitable sizes,unserviceable spares and jumper connections in all phases for smooth functioning of the devices all as directed by Engr-in-charge. Note : Unserviceable spares and jumper connections replaced shall be measured and paid separately as "Supply only"
Supply only the following items : (a) Male contact/moving contact with blade arcing horn of gang operated AB switch devices suitable for 22 KV
(b) Female contact /fix contact jaw arcing horn for gang operated AB switch devices.
(c) Tinned copper flexible jumper 200/200 Amps
(d) Post top Polymer insulators of gang operated AB switch devices.
(e) Middle post Polymer insulators of gang operated AB switch devices.
(f) Bottom post Polymer insulators of gang operated AB switch devices.
(g) MS jumper carrier.
(h) Back connector plate.
GI pipe, heavy grade 20 mm dia made to shape for gang operating from ground.
Repairs to drop out fuse complete upto 400 Amps,22 KV capacity including renewal of worn out nut bolts,washers,of suitable size /unserviceable spares and jumper connections for smooth functioning of the devices all as directed by Engr-in-charge. Note : Unserviceable spares and jumper connections replaced shall be measured and paid seprately as "Supply only"
Supply only the following items (to be incorporated under Item No 90 above) a) Fix top contact/ contact for drop out fuse.
b) Fix lower contact for drop out fuse.
c) Post insulators of drop out fuse.
Supply, install, testing and commissioning of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete , GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts suitably tinned to with stand weather complete all as specified and directed.
Supply and fix in repair Polymer Pin type insulator of 22 KV including necessary hardware complete all as specified and directed.
Supply and fix in repair Polymer disc type insulator, ball and socket type, white brown or green suitable for 22KV including necessary hardware complete all as specified and directed
Supply and fix in repair lightining distribution surge arrestor, non linear type MCOV, 18 KV, 5 KA with all fittings bolts nuts and washers etc all as specified and directed.
Material and labour for preperation of old painted steel surface of 6/4/2 pole structure HT/LT street light/HT steel tublar poles 8.5/9.0/11/13 mtr long above GL/coping including cross arms,channels,Flat iron,Clamps in LT/HT OH line by scraping with wire brush/ sand paper and applying one coat of aluminium paint including pole numbering all as specified and directed by Engr-in-charge for the following types:- a) HT 4 Pole structure 11 metre long
b) HT 2 Pole structure 11 metre long
c) HT pole 11 metre long
d) LT pole 8.5/9 metre long
Disconnecting the transformer outdoor type from HT/ LT system and opening carefully by draining out transformer oil upto HT/LT boxes for rectifying the leakage by replacing the unserviceable spare parts of capacity 50 to 750 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system after the leakages have been rectified and tested on available electric load complete all a specified and directed. Note : Defective parts replaced will be measured and paid separately as "Supply only" under respective items here in after.
Supply only LT bushings with brass studs of existing specification complete all as specified and directed.
Supply only top cover gasket set complete all as specified and directed.
Supply only HT bushing with stud 22 KV of existing specification complete all as specified and directed.
Material and labour for preparation of old painted surfaces of transformer, removing rusted scale/oil & painting of transformer with one coat of synthetic enamel paint of approved make duly Marking/ Writting MES/SM No. all as directed by Engr-in-charge for : (a) 160 to 250 KVA capacity of transformer.
(b) 300 to 500 KVA capacity of transformer.
Re-Stringing of HT/LT over head conductor and earth conductors complete all as specified and directed by Engr-in-charge
Material and labour for disconnecting from existing main taking out from LT Panel board for servicing & overhauling of LT ACB of any make 800 to 1600 Amp, 50Hz 415V AC Draw out type including taking out existing mechanism complete with servicing of operating machnism, triping mechanism and spring charging mechanism complete to make it funtioning smoothly and including replacement of unserviceable spares and fixing in its original postion with all connections and testing complete all as specified and directed. Note : Major spare parts are to be paid separetly under respective items here in after as supply only however cost of minor spares except mentioned in item no 110 to 113 below shall be deemed to be included in item rate quoted.
Supply only Following spare parts suitable LT ACB suitable 800A-1600 A Capacity :- (a) Main isolating contact (Male and Female) jaw type complete inclubing fixing accessories
(b) Shunt Trip coil/ Closing coil 415 VAC suitable for 800 amps ACB
(c) Under voltage tripping divicee (UVT) 415 volts
(d) Single phae CTS at rating 800/5A
Supply and fixed in repair MCCB 3 pole, 320 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed.
Supply and fixed in replacement of MCCB 3 pole, 250 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed.
Supply and fixed in replacement of MCCB 3 pole, 200 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed.
Supply and fixed in repair MCCB 3 pole, 125 Amps, 16 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type omplete all as specified and directed.
Supply and fix Pin type, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade including taking out existing unserviceable insulator all as specified and as directed.
Supply and fix insulator shackle type, porcelain, vitreous, white, brown or green insulator including galvanised and mild steel straps of size 31x5mm, washers, insulator bolts, washers and nuts, size of insulator 100 mm height, 115 mm dia with 14 mm dia bolts for 1100 Volts grade including taking out existing insulators complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-2 using 40mm graded aggregate as in foundations of stays and poles, copping of poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Supply and fix LED street light /road way luminaries 45 watts with pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket including taking down existing unserviceable fittings complete all as specified and as directed.
Supply and fix of LED street light /road way luminaries 60 watts with pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket including taking down existing unserviceable fittings complete all as specified and as directed.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300 x 200 x 105mm internal comprising, one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in & loop out suitable for single phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron all as specified and directed.
Supply and fixing in repair Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 8 kW single-Phase load .Contactor Rating: 40.Amps ( 2-pole ).MCB (single-pole) Rating:63.Amps (2 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (EnC Approved) Contactor: BCH/L&T/Schneider or equivalent MCB: Hager/Schneider/Legrand/L&T. Make:SWADEEP – 02EC 8kW1P
Supply, install test and commissioning of LT Panel Board CPRI approved cubical with kiosk type made of 3.15 mm thick outdoor type with IP 65 grade of protection CRCA sheet, powder coated, with support of 50mm x 50mm x 6mm angle iron bottom frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved aluminium bus bar of capacity 350 Amps- 4Nos, for each phases and neutral fixed on suitable insulator all housed in suitable bus bar chamber and provision and fixing of multifunction meter, CTs of suitable ratio, and LED pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations complete testing and commissioning including taking down existing LT Panel complete all as specified and directed and shall be consisting the following :- Incomer: MCCB with thermal magnetic release range 250 Amps, 4 pole,36 KA breaking capacity- 01 No, Outgoing: MCCB with thermal magnetic release range 125 Amps, 4 pole,36 KA breaking capacity- 02 No, coloured heat shrinkable PVC insulated aluminium bus bar 350 Amps, 3 phase, wire , LED Pilot lamps,( R,Y & B) -01 set , LED Digital multi function meter with CTs-01 set extended rotary handles and spreader terminals for all MCCBs.(Location: Shakkal Nagar Power house)
Supply, lay, connect, testing and commissioning of LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium multi stranded aluminium conductor heavy duty 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following sizes including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings/walls without cable duct) including taking down old unserviceable cable complete all as directed by the Engr-in-Charge for the following :- Notes : (i) Excavation, sand cushioning, cable cover will be measured and paid separately under relavant item here in before . (ii) Cost of jointing material e.g. lugs, thimbles, glands, nut bolt and washers shall include in quoted rates. (a) 120 Sqmm 3.5 core
(b) 50 Sqmm 3.5 core
(c) 35 Sqmm 3.5 core
(d) 25 Sqmm 4 core
(e) 16 Sq mm 4 core
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/ LT under ground cable and getting out in the following type of soil complete all as specified and as directed:- (a) Soft soil
(b) Hard soil
(c) Soft/ Disintegrated rock
(d) Hard Rock
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and lay in trenches reinforced precast concrete cable cover class LV, Type I, flat, size 250mm x150mm x 40mm for cable protection all as specified and directed by the Engr-in-Charge.
Material and labour for riddled earth filling in trenches to required width at bottom and top of cable cusioning including spreading leveling and consolidation complete all as specified and as directed. Note : Punned thickness shall be measured and paid.
Material and labour for 63 Amp, 4 pole, 6 way busbar chamber, busbar made of ETP grade copper, wall mounted type suitable for 415 volt, Ac including fixing arrangements clamps, glands, nuts and bolts complete all as specified and as directed by Engr-in-Charge.
Material and labour for straight through joint,heat shrinkable,type,for HT OH AB cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 to 120 sqmm,22 KV all as specified and directed by Engineer-in-charge.
Material and labour for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 95 sqmm, 22 KV all as specified and directed by Engr-in-charge
Cutting the tree branches which touches the LT/HT OH lines and 2.5 mtr away from centre line of HT/LT OH line span not exceeding 60 mtrs between poles and deposting the tree branches/leaves at 30 m distance away from site. Note : Any number of tree branches cut in one span will be measured as one length for payment purpose.
Material and labour for cleaning of water storage tank above / under ground sump by draining out complete water, scrapping the inner walls of tanks with wire brush / brooms, for removing the fungus, algae, soil, sludge mud etc complete including rewashing the inner walls of tank with fresh water to ensure complete cleaning including painting with water proof antifungal epoxy paint and writing on the outer walls of the tank with synthetic enamel paint the date of cleaning, due date of next cleaning & capacity complete all as specified and directed. Notes : (i) Cost of wire brush, brooms cleaning chemicals deemed to be included in the quoted rates. (a) Water storage tank/reservior of capacity 30000 to 50,000 Glns for fresh water in Ganeshkhind pump House.
(b) Over head Tank of capacity 100000 Glns
Material and labour for painting with one coat of synthetic enamel paint by using brush to motor and pump set including cleaning and preparing surface duly scraping old paint and writing SM/MES No.all as specified and directed by Engineer-in-charge for following:- (a) 40 to 75 HP motor
Material and labour for painting of old painted surfaces of pipe 100 to 150 mm dia including preparation of surfaces and applying one coat of synthetic enamel paint complete all as directed and required at site.
Material and labour for painting of old painted surfaces with one coat synthetic enamel paint by using brush to sulice valve and wheel of size 100 to 200 mm dia including cleaning with chemical agent and preparing surface duly scraping old paint all as specified and directed .
Material and labour for Overhauling of centrifugal pump sets by dismantling the pump set,opening,cleaning,greasing including renewal of spare parts and reassembling after repairs including,metaling,grinding etc transpotation, reinstalling back to position and testing complete for the following capacites of pump sets:- Note:-Spares parts renewed shall be measured and paid seperately as "Supply only". (i) 30 HP to 75 HP Pump DSM 4 RR/DSM 4 RM/DB 65/20
Supply only spares for 30 to 75 HP Pump DSM 4RR/DSM4 RM /DB 65/20, Pumps(Make:-Kirloskar pumps) (a) Shaft sleeve
(b) Shaft sleeve nuts ( set of 4)
(c) Bearing cartridge DE/NDE
(d) Bearing cover DE/NDE (set of 2) Split gland coupling
(e) Bearing cap (set of 2)Wear Ring
(f) Bearing lock nut
(g) Throat bush (set of 2)
(h) Gland packing 10MMSQ
(j) DSM 100/36 set of Gaskets
(k) DSM 100/36 set of 'O' rings
(l) Impeller 1st/ 2nd stage
Disconnecting the electrical and mechnical connection of burnt electrical motors from the site/location including transporting to and from workshop, rewinding of electrical motors by dismantling and removing the burnt out copper winding wire,cleaning the slots of stator with petrol and brushes,winding with polyster based super enameled copper wire of same guage of original one with proper class of insulation including varnishing and heating the coil and remove the air bubbles complete,stator/rotor after rewinding,reassembling all parts including reinstalling,connection to original position and testing on full load all as directed by Engineer-in-charge for capacity of motor as per following:- (a) 30 HP three phase motor 415 V
(b) 75 HP three phase motor 415 V
Supply only roller ball bearing/Double ball bearing thrust ball bearing of pumps/motor of following sizes:- (a)6309
Supply and fix power contactors MCE 110 Amp type with 2NO+2NC ,CP No.CS94137 in existing pumping set starter panel including necessary testing complete all as specified and directed.
Supply and fix in repair unserviceable pressure guage range 0 to 14 Kg/cm2 with 100 mm dia with one stainless steel cock.
Supply and Fix rubber packing sheet 3 mm thick complete all as specified and directed.
Supply and fix in replacement rubber bush for pin type coupling for any type of pump and motor complete all as specified and directed.
Supply and fix lead pig for repair of leaking joints complete all as specified and directed.
Supply and fix spun yarn for repair of leaking joints complete all as specified and directed.
Supply and fix lead wool for repair of leaking joints complete all as specified and directed.
Dismantling the disturbed valve chambers and construction of brick masonry vave chamber of the following sizes(internal dimensions) including necessary earth work excavation in any type of soil,PCC(1:4:8),type D2 in foundation,brick masonry of wall thickness of 230 mm in CM(1:6) rendering CM(1:6) internally and externally including to a depth of 15 cm below GL,3 mm thick hinged MS iron cover as specified in IS-3950-1979 embeded in PCC with locking arrangment and painting with two coats of distinctive color synthetic enamel paint over a coat of red oxide primer PCC(1:2:4) B1,50 mm thick coping and locking arrangment etc complete all as specified and directed:- (a) 900x900x1200 mm
(b) 1200x1200x1200 mm
Burning out leaking lead joints in position and removing of old lead as credit to contractor as per sch of credit from the following sizes complete all as specified and directed by Engineer-in-charge. (a) 80 mm dia bore of pipe
(b) 100 mm dia bore of pipe
(c) 150 mm dia bore of pipe
Material and labour for run lead joints for CI pipes/fittings complete with necessary jointing material such as pig lead and spun yarn,fire wood for jointing of pipes all as directed by Engineer-in-charge for the following sizes:- (a) 80 mm dia bore of pipe
(b) 100 mm dia bore of pipe
(c) 150 mm dia bore of pipe
Taking up or down GI water tubing including removing of all necessary connections/fittings as specified and directed by Engineer in Charge. (Note : excavation and earth work will be measured & paid separately) (a) 15 mm dia
(b) 20 mm dia.
(c) 25 mm dia
(d) 40 mm dia
(e) 50 mm dia
(f) 80 mm dia
Taking up or down CI/DI pipe 150mm including removing of all necessary connections/fittings as specified and directed by Engineer in Charge. Note :excavation and earth work shall be measured & paid separately
Supply and fix Ductile iron for 150mm dia pressure pipes, class K7 with spigot and socket ends conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and as directed. Note: Cost of Push-on type joints, either "Tyton or Fastite" joints, DI Specials, cutting of existing pipeline shall be deemed to be included in quoted rates.
Relaying and refixing the GI pipe after descaling / cleaning complete with the help of water & brush of the following size / bore obtained from Sl item No 181 above and connect in old / new positions, laid in trenches fixed on wall on floor including of necessary fittings such as bends, tee, unions, elbows, sockets etc (a) 15 mm dia.
(b) 20 mm dia.
(c) 25 mm dia
(d) 40 mm dia
(e) 50 mm dia
(f) 80 mm dia
Supply and fixing of GI tubing medium grade ISI marked fixed on wall, roof, floor complete with necessary accessories such as Tees union , bend ,elbow nipple reducer etc , all as required at site for branch connection including cutting threading all as directed by Enginner-in-Charge. (a) 15 mm dia
(b) 20 mm dia.
(c) 25 mm dia
(d) 40 mm dia
(e) 50 mm dia
(f) 80 mm dia
Material and labour in galvanized iron water tubing medium grade ISI marked laid in trenches complete with necessary accessories such as Tees union,bend,elbow nipple reducer etc all as required at site for branch connection including cutting threading all as directed (a) 15 mm dia
(b) 20 mm dia.
(c) 25 mm dia
(d) 40 mm dia
(e) 50 mm dia
(f) 80 mm dia
Disconnecting/taking down unserviceable worn out CI sluice valve with SS Spindle and supply and fix new CI sluice valve PN 1.6 with SS spindle as required at site and as directed by Engineer-in-charge:- (a) Sluice valve 100 mm dia
(b) Sluice valve 150 mm dia
(c) Sluice valve 200 mm dia
Supply and fix Foot valve ball type heavy duty suitable for 150 mm dia pipe line complete all as specified and directed.
Material and labour cutting of Roads / Plinth to width n exc 300mm and depth n exc 300 mm complete all as specified and directed. Note: PCC will be measured and paid separetely.
Material and labour PCC in 1:2:4 type B 1 by using 20 mm graded stone aggregate for making good road/foot path/hard standing/drain/ bldg plinth protection and foundation for motors, pumps and starters all as per site requirement and as directed by Engr-in-Charge.
Disconnection of existing water storage tank any type at 3.0mtr height and above, removal of water if any from the tank and cleaning the bottom and internal periphery of the tank by using wire brushes to remove the Mud, Algae, fungus etc without damaging the water tank and finally rinsing the tank by using chlorine/bleaching powder/altoc GP or any other similar type of disinfectent chemical as directed by Engr-in-Charge complete all as specified or as directed at site. Note : Date of cleaning shall be written after cleaning in format DD/MM/YY with synthetic enamel paint after removing the earlier date if found exisitng. (a) Capacity upto 1000 litre
Supply and fix in repairs ball valves high pressure of PTMT with epoxy coated luminium rod & highdensity plastic ball screwed for iron pipe and fixed for the following sizes at any height of building complete all as specified and directed :- Note : All T&P required for complete the work shall be arranged by the contractor and no any extra payment will be admissible on this account. (a) for 15mm dia
(b) for 20mm dia
(c) for 25mm dia
Repair to water supply line (Fresh water) with mechanical joint, of CI pipe line of size150 mm including taking out the leaked /puncture/cracked existing pipe , cutting of damaged portion of pipe through welding, making rough surfaces smooth and champhered by grinding and then connected through GI pipe jointing material adequate size complete as per site requirement. Note : Testing/commissioning the pipe line on full pressure after complete the job will be carried out and payment will made of this job if found sucess other wise the same will be done against and no extra payment will be made on this account.
Supply and fixing of CI/DI fitting for spigot socketed pipes such as Bends (any type, radius an angle) Tapers any tpe, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branc, `Y' junction, double branch, cross (all sockets or flanged ) collars, caps and plugs, Connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth Upto150 mm bore complete all as specified and directed.
Supply install testing and commissioning of Electromagnetic Digital water flow meter along with UPS back up suction/delivery size 150 mm dia on existing CI/DI water supply pipe line 150 mm Metering details as follow :- Type : Pulsed DC Meter size : DN 150 Coil housing : MS Liner : Hard Rubber Electrodes : SS316 Process connection : DIN PN 16 Flanges : Carbon Steel Area classification : Non‐Hazardous Protection class : IP 68 Mounting : Remote with 10 Mtr Cable Type : Microprocessor Based Output : 4 ‐ 20mA + MODBUS RS 485 Accuracy : ± 0.5% of measured value for velocity Display : LCD Display Parameters : Actual flow rate, totalized flow (8 digit) Local indication : Programmable by keys Power supply : 230V AC Housing : Aluminium Area classification : Non‐Hazardous Protection class : Weather Proof‐IP 65 Make: Krohne/Siemens/Spire Note: The rate shall be including PMC/MITC lab testing
YOGESH ELECTRICALS
SKS Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .