| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.9 LAdmitted-Finance 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | L1 | Admitted-Finance | |
| 2 | L2₹94.1 L+₹21,894 (0.23%)Admitted-Finance VOLTAS HOUSE B 2ND FLOOR T B KADAM MARG CHINCHPOKLI MUMBAI 400 033 | MUMBAI | MUMBAI | MAHARASHTRA | 400033 | L2 | Admitted-Finance | |
| 3 | L3₹97.9 L+₹4.0 L (4.28%)Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L3 | Admitted-Finance | |
| 4 | L4₹1.1 Cr+₹14.9 L (15.8%)Admitted-Finance OFFICE NO 44 45 2ND FLOOR CRYSTAL PLAZA HIRANANDANI COMPLEX PLOT NO 18 27 SECTOR 7 KHARGHAR RAIGAD MAHARASHTRA 410210 | RAIGAD | MAHARASHTRA | 410210 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SPEEDFROST SERVICES PVT LTD L1 | Powermech Services Private Limited L4 | Bluestar Limited L3 | VOLTALIMITED L2 |
|---|---|---|---|---|---|---|---|
| 1.00Semi-comprehencive maintenance (preventive + breakdown) of following central AC plant equipments (excluding chillers) as per tender technical specifications (for 24 months): | |||||||
| 1.01 | Air Handling Units upto 50 TR capacity (Chilled water type) - 13 nos. (Service frequency - quarterly) | 104 | Service | 3,500 ₹3,64,000 Lowest | 6,600 ₹6,86,400 | 15,000 ₹15,60,000 | 9,375 ₹9,75,000 |
| 1.02 | Air Handling Units upto 40 TR capacity (Chilled water + DX type, including ODU) - 09 nos. (Service frequency - quarterly) | 72 | Service | 3,000 ₹2,16,000 Lowest | 6,600 ₹4,75,200 | 12,000 ₹8,64,000 | 7,500 ₹5,40,000 |
| 1.03 | Air Handling Units upto 17 TR capacity with ODU (Dx type) - 08 nos. (Service frequency - quarterly) | 64 | Service | 28,000 ₹17,92,000 | 3,960 ₹2,53,440 | 5,100 ₹3,26,400 | 3,187.5 ₹2,04,000 Lowest |
| 1.04 | Fan coil units up to 3 TR capacity - 46 nos. (Service frequency - quarterly) | 368 | Service | 2,000 ₹7,36,000 | 2,750 ₹10,12,000 | 1,125 ₹4,14,000 | 563 ₹2,07,184 Lowest |
| 1.05 | 40 HP capacity, centrifugal chilled water pumps - 04 nos. (Service frequency - quarterly) | 32 | Service | 5,000 ₹1,60,000 Lowest | 6,380 ₹2,04,160 | 12,000 ₹3,84,000 | 7,500 ₹2,40,000 |
| 1.06 | 25 HP capacity, centrifugal chilled water pumps - 03 nos. (Service frequency - quarterly) | 24 | Service | 4,500 ₹1,08,000 | 4,400 ₹1,05,600 Lowest | 7,500 ₹1,80,000 | 4,688 ₹1,12,512 |
| 1.07 | 60 HP capacity, centrifugal condenser water pumps - 02 nos. (Service frequency - quarterly) | 16 | Service | 5,000 ₹80,000 Lowest | 6,820 ₹1,09,120 | 18,000 ₹2,88,000 | 11,250 ₹1,80,000 |
| 1.08 | 25 HP capacity, centrifugal condenser water pumps - 03 nos. (Service frequency - quarterly) | 24 | Service | 2,800 ₹67,200 Lowest | 4,730 ₹1,13,520 | 7,500 ₹1,80,000 | 4,688 ₹1,12,512 |
| 1.09 | Induced draft cooling towers of 500 TR capacity - 02 nos. (Service frequency - quarterly) | 16 | Service | 10,000 ₹1,60,000 | 6,710 ₹1,07,360 Lowest | 59,375 ₹9,50,000 | 25,000 ₹4,00,000 |
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
7 Aug 2024, 6:00 pmClosed
Chief Engineer and Director, ESG
Chief Engineer and Director, Engineering Services Group, BARC, Trombay, Mumbai-400085
Maintenance of HVAC and mechanical systems at BARC Hospital and CTCRS building, Anushaktinagar, Mumbai - 400 094.
2024_BARC_816946_1
BARC/CSS/ET/10/2024-2025
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
730 days
BARC Hospital, Anushaktinagar, Mumbai
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹2.0 L
BARC Hospital, Anushakti Nagar
27 Aug 2024
18 Jul 2024
9 Aug 2024
18 Jul 2024
7 Aug 2024
26 Jul 2024
18 Jul 2024 - 29 Jul 2024
25 Jul 2024
Amount
Semi-comprehencive maintenance (preventive + breakdown) of following central AC plant equipments (excluding chillers) as per tender technical specifications (for 24 months):
Air Handling Units upto 50 TR capacity (Chilled water type) - 13 nos. (Service frequency - quarterly)
Air Handling Units upto 40 TR capacity (Chilled water + DX type, including ODU) - 09 nos. (Service frequency - quarterly)
Air Handling Units upto 17 TR capacity with ODU (Dx type) - 08 nos. (Service frequency - quarterly)
Fan coil units up to 3 TR capacity - 46 nos. (Service frequency - quarterly)
40 HP capacity, centrifugal chilled water pumps - 04 nos. (Service frequency - quarterly)
25 HP capacity, centrifugal chilled water pumps - 03 nos. (Service frequency - quarterly)
60 HP capacity, centrifugal condenser water pumps - 02 nos. (Service frequency - quarterly)
25 HP capacity, centrifugal condenser water pumps - 03 nos. (Service frequency - quarterly)
Induced draft cooling towers of 500 TR capacity - 02 nos. (Service frequency - quarterly)
Induced draft cooling towers of 150 TR capacity - 03 nos. (Service frequency - quarterly)
Fume Hood/ Smoke/ Air exhaust blowers - 10 nos. (Service frequency - quarterly)
Kitchen exhaust system - 02 nos. (Service frequency - quarterly)
Cold Storage System of 3 TR capacity - 06 nos. (Service frequency - quarterly)
20 HP capacity, centrifugal domestic water pumps - 03 nos. (Service frequency - quarterly)
Inline centrifugal/ axial exhaust fan upto 500 Watt. capacity - 12 nos. (Service frequency - quarterly)
Air Curtain - 06 nos. (Service frequency - quarterly)
Semi-comprehencive maintenance (preventive + breakdown) of following low temperature equipments as per tender technical specifications (for 24 months):
1.0/1.5 TR capacity split/window type air-conditioners (Qty-440 nos) (Service frequency - quarterly)
2.0 TR capacity split type air-conditioners (Qty-44 nos) (Service frequency - quarterly)
14 TR capacity Precision air-conditioners, Make- Bluestar, Model - PCX502DTR1 (Qty-02 nos) (Service frequency - quarterly)
3.0 TR capacity Ducted split air-conditioners, Make- Bluestar, Model- DSA361R2 (Qty-05 nos) (Service frequency - quarterly)
Water coolers having capacity up-to 150 ltrs. (Qty-25 nos) (Service frequency - monthly)
Water purifier of BARC technology (UF membrane based) (Qty-71 nos) (Service frequency - monthly)
Overhauling/Brought Down Servicing of 1.0/1.5/2.0 TR capacity split ACs by dismantling indoor unit from location (as instructed by department)
Providing V-belt of following types as & when required as per technical specification:
Providing CI taper lock pulley with bush of following sizes as & when required as per technical specification:
A/ 100-140 mm pitch dia
A/ 150-180 mm pitch dia
A/ 200-250 mm pitch dia
B/ 125-150 mm pitch dia
B/ 160-190 mm pitch dia
B/ 200-225 mm pitch dia
B/ 250-280 mm pitch dia
Providing spare parts for centrifugal pumps/blowers/cooling tower as per technical specification:
Deep groove ball bearing suitable for 25-35 mm shaft OD
Deep groove ball bearing suitable for 38-50 mm shaft OD
Mechanical Seal of 35-45 mm seal bore
Mechanical Seal of 50-75 mm seal bore
Flat belt for cooling tower (11-1KR189 FLAT BELT KW15)
Providing & installing spare parts / items for upto 600 ltr. Capacity refrigerator as per technical specification:
Replacement of non-inverter compressor along with gas charging
Replacement of inverter compressor along with gas charging
Finding out leak by pressure testing, repairing of the same, vacuumizing & gas charging
Heater tube as per OEM
Relay with overload protector as per OEM
Bimetallic thermostat with thermal fuse
Freezer/ condenser fan motor (ac/dc) for refrigerator as per OEM
Timer for auto defrost as per OEM
Thermostat for temperature control as per OEM
Providing & installing door gasket as per original size
Repair of PCB of digital refrigerators through OEM
Providing PCB set of digital refrigerators through OEM
Arranging repair through OEM authorised service engineer
Providing spare parts / items for air-conditioners & outdoor units as per technical specification:
Replacement of non-inverter compressor of upto 2.0 TR capacity as per OEM with gas charging
Replacement of Inverter compressor of upto 1.5 TR capacity as per OEM with gas charging
Replacement of non-Inverter compressor fur cold storage unit or Dx ODUs with gas charging
Repair of PCB (with sensor) of non-inverter AC
Repair of PCB (with sensor) of inverter AC through OEM
Providing PCB (with sensor) of non-inverter AC
Providing PCB (with sensor) of inverter AC through OEM
Repair of IDU blower motor/condenser fan motor (if winding ok)
Providing new IDU blower motor/condenser fan motor
Replacement of defective al/cu condenser coil with new copper condenser coil including installation, pressure testing, gas charging and commissioning for split ACs of upto 2 TR capacity
Replacement of defective evaporator coil with new copper coil including installation, pressure testing, gas charging and commissioning for split ACs of upto 2 TR capacity
Providing IDU mounting plate as per site requirement
Providing remote control along with dry cell as per tender specification
Providing S2/P2 protected metallic explosion proof capacitors as per capacity & quantity mentioned in technical specification
Arranging repair through OEM authorised service engineer
Providing spare parts / items for BARC technology water purifiers as per technical specification:
Pre-filter
UF membrane (Washable)
Spiral UF membrane (Auto clean)
Carbon filter
SS/ABS frame with bracket for BARC technology water purifier
BARC technology based UF membrane type 3-stage water purifier including piping/ accessories
Providing caustic soda for coil/filter cleaning application as per technical specification
Condenser water treatment chemical to control algal, bacterial and fungal growth, chilled water chemical to control corrosion & scale formation along with cooling coil cleaning chemical
Cooling tower water treatment microbiocide chemical (non-flammable)
Cooling coil cleanser chemical (acidic & non-flammable)
Providing Drive belt dressing spray for increasing belt life as per technical specification
Carrying out installation/ Re-installation work of split ACs as per site requirement as & when required
Providing & installing rigid u-PVC piping with fittings
Robotic duct cleaning as per technical specification
Repairing of damaged/leaked gate valves upto 8 inch dia including oiling/greasing/servicing/painting and replacing gland etc in case when body is not damage
Winding/repairing & bearing change of fan motors upto 1/2 HP capacity
Modification in GI ducting along with necessary fittings from following sheet thickness:
Providing & replacing fire retardant flexible canvass connection
Carrying out FRP lining work of 3 layer thickness
SS316 100 mm dia glycerin filled dial type compound gauge (-1) to 4kg pressure range
Replacement of old/ defective follopwing items as per technical specification:
Aluminium powder coated grilles/diffusers with volume control dampers
Aluminium powder coated grilles/diffusers without volume control dampers
GI volume control damper
Providing MS supports and structures as per site reuqirement, e.g. Square pipe, ISMB, ISMC, angles, flats, plates, mesh etc.
Painting of MS pipeline/supports of various sizes, chilled water pipeline of varios sizes, FRP ducts etc with one coat of primer & two coats of paint of approved colour
Providing GI items like elbows, reducers, slip on flanges, nut-bolts, washer etc.
Disposal of scrap like thermocol/ nitrile rubber/ plaster materials / PVC fills etc beyond the limit of MMR by suitable truck as per technical specification
VOLTALIMITED
Bluestar Limited
Powermech Services Private Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 12.80 MB
Tenderdocument10.pdf
Tender Documents • 1.40 MB
TECHNICALBID10.xls
Tender Documents • 0.19 MB
BOQ_858527.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .