Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | ₹32.1 L Quoted ₹32.5 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹34.3 L+₹1.8 L (5.60%)Rejected-Finance MES COLONY KUMBHIGRAM AIRPORT CACHAR ASSAM 788109 | KUMBHIGRAM | CACHAR | ASSAM | 788109 | ₹34.3 L+₹1.8 L (5.60%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹40.5 L+₹8.0 L (24.7%)Rejected-Finance H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | ₹40.5 L+₹8.0 L (24.7%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | Rejected-Technical 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | - | - | Rejected-Technical Category not as per NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Category not as per NIT |
| Sl No | Description | Qty | Unit | M/s JK Jangid and Company L3 | M/S SEWAK SINGH L1 | Goswami Traders L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity complete all as specified and as directed . | 50 | Each | 749 ₹37,450 | 200 ₹10,000 Lowest | 634 ₹31,700 |
| 2.00 | Supply and fix in repair heating element of 2.0 KW (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as specified and as directed . | 250 | Each | 1,614 ₹4,03,500 | 1,400 ₹3,50,000 | 1,367 ₹3,41,750 Lowest |
| 3.00 | Supply and fix in repair 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as specified and as directed . | 200 | Each | 591 ₹1,18,200 | 150 ₹30,000 Lowest | 500 ₹1,00,000 |
| 4.00 | Supply and fix in repair 600 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as specified and as directed . | 20 | Each | 791 ₹15,820 | 200 ₹4,000 Lowest | 670 ₹13,400 |
| 5.00 | Supply and fix in repair thermostat suitable for 25 ltr capacity Gyesers complete all as specified and as directed . | 100 | Each | 1,038 ₹1,03,800 | 350 ₹35,000 Lowest | 880 ₹88,000 |
| 6.00 | Supply and fix in repair thermostat suitable for 50 ltr capacity Gyesers complete all as specified and as directed . | 15 | Each | 993 ₹14,895 | 400 ₹6,000 Lowest | 840 ₹12,600 |
| 7.00 | Supply and fix in repair indicator bulb for geyser (Red & green) complete all as specified and as directed . | 80 | Each | 1,057 ₹84,560 | 40 ₹3,200 Lowest | 895 ₹71,600 |
| 8.00 | Supply and fix in repair geyser base plate assembly including rubber washer suitable for 25 ltr capacity Gyesers complete all as specified and as directed . | 10 | Each | 1,362 ₹13,620 | 350 ₹3,500 Lowest | 1,153 ₹11,530 |
| 9.00 | Supply and fix in repair geyser base plate assembly including rubber washer suitable for 50 ltr capacity Gyesers complete all as specified and as directed . | 10 | Each | 1,445 ₹14,450 | 400 ₹4,000 Lowest | 1,224 ₹12,240 |
| 10.00 | Supply and fix in repair glass wool sheet of size 8x4 Sqmm for insulation of 25/50 Ltrs capacity geyser, water cooler, Deep freezer etc complete all as specified and as directed . | 1 | Per Sqm | 749 ₹749 | 400 ₹400 Lowest | 634 ₹634 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
11 Jul 2025, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
REPAIR MAINT OF GEYSERS AND SUMMER APPLIANCE AC WATER COOLER, REFRIGERATOR DEEP FREEZER ETC INCLUDING FLAME PROOF FITTING AND FIXTURES IN AMN SHEDS AND POL DEPOT AND CONNECTED ALLIED WORKS UNDER GE NARANGI
2025_MES_716162_1
8073/B/E8
Open Tender
Civil Works
Item Rate
180 days
Guwahati
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Narangi
₹76,000
Yes
29 Nov 2025
21 Jun 2025
14 Jul 2025
21 Jun 2025
11 Jul 2025
5 Jul 2025
Amount
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity complete all as specified and as directed .
Supply and fix in repair heating element of 2.0 KW (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as specified and as directed .
Supply and fix in repair 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as specified and as directed .
Supply and fix in repair 600 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as specified and as directed .
Supply and fix in repair thermostat suitable for 25 ltr capacity Gyesers complete all as specified and as directed .
Supply and fix in repair thermostat suitable for 50 ltr capacity Gyesers complete all as specified and as directed .
Supply and fix in repair indicator bulb for geyser (Red & green) complete all as specified and as directed .
Supply and fix in repair geyser base plate assembly including rubber washer suitable for 25 ltr capacity Gyesers complete all as specified and as directed .
Supply and fix in repair geyser base plate assembly including rubber washer suitable for 50 ltr capacity Gyesers complete all as specified and as directed .
Supply and fix in repair glass wool sheet of size 8x4 Sqmm for insulation of 25/50 Ltrs capacity geyser, water cooler, Deep freezer etc complete all as specified and as directed .
Supply and fix in repair plug top 3 pin 15 amps ISI marked complete all as specified and as directed .
Material and labour for wall fastener of size 100 mm long, 8mm dia with double washers grouting making good in walls cement mortar (1:4) for fixing water heater, spilit AC outdoor after removing the existing unserviceable nuts /bolts and washers complete all as specified and directed.
Supply and fix in repair sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity exc.180 and n.exc 310 ltrs including sealing of the compressor with welding after assembling complete all as specified and as directed .
Supply and fix in repair sealed unit compressor suitable for Refrigarator/Deep Freezer capacity upto 180 ltrs including sealing of the compressor with welding after assembling complete all as specified and as directed .
Labour only attending complaints for refrigerator, deep freezer, water cooler of any make, any capacity complete all as specified and as directed .
Supply and fix in repair relay suitable for Refrigarator/ Deep Freezer of capacity upto 310 ltrs capacity complete all as specified and directed.
Supply and fix in repair condenser coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed.
Supply and fix in repair fan motor suitable for Refrigarator/ Deep Freezer of capacity upto 310 ltrs of existing make complete all as specified and directed.
Supply and fix in repair door rubber gasket complete suitable for refrigerator upto 310 ltrs capacity all as specified and directed.
Supply and fix in repair thermostatic switch of suitable for Refrigarator/Deep Freezer upto 310 ltrs capacity all as specified and directed.
Supply and fix in repair filter stainer of suitable for Refrigarator/Deep Freezer upto 310 ltrs capacity all as specified and directed.
Supply and fix in repair cabinet lamp with holder and push switch including replacement of electric wires for Refrigerator upto 310 Ltrs capacity complete all as specified and directed.
Supply and fix in repair ice chamber cabinet of Refrigerator of capacity upto 310 ltrs complete all as specified and directed.
Material and labour for leak testing with nitrogen dioxide as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried out in the presence of Engineer in Charge
Material and labour for servicing only in situ of Split type air conditioner 1.5/2.0 Ton capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete all as specified and directed.
All as per serial item No. 25 here-in-above but window type air conditioner 1.5/2.0 TR capacity.
Dismantling of Split type/Window Type air conditioner 1.5 ton capacity after removing indoor outdoor copper tube connection, electric wire connection and transporting to authorised workshop for reapir/replacement of compressor, cleaning of Cooling coil, condenser coil, fan motor and re-installing the same after complete repairs and testing of full load in presence of Engineer in Charge complete all as specified and directed . Note:- Sealed compressor will be measured and paid separately
All as per serial item No. 27 here-in-above but Split AC/window type air conditioner 2.0 TR capacity.
Supply only sealed compressor including sealing of the compressor with welding after assembling for 1.5 ton capacity Spilit type AC/ Window type AC complete all as specified and directed.
Supply only sealed compressor including sealing of the compressor with welding after assembling for 2.0 Ton Capacity Spilit type AC/window type AC complete all as specified and directed.
Supply and fix in repair running capacitor 45 MFD for window type/split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
Supply and fix in repair starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 ton capacity complete all as specified and directed.
Supply and fix in repair box type relay suitable for 1.5/2.0 ton split type/window type AC complete all as specified and directed.
Supply and fix in repair condenser coil unit complete for 1.5/2.0 Ton split type/window type AC complete all as specified and directed.
Supply and fix in repair capilary tube suitable for 1.5/2.0 ton split type/window type AC complete all as specified and directed..
Supply and fix in repair filter unit suitable for 1.5/2.0 Ton split type/window type AC complete all as specified and directed.
Supply and fix in repair swing motor suitable for 1.5/2.0 Ton split type/window type AC complete all as specified and directed.
Supply and fix in repair roller of indoor unit of split type A/C 1.5/2.0 Ton capacity all as specified and directed.
Supply and fix in repair fan blade with blower motor of window/split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
Supply and fix in repair control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed.
Supply and fix in repair control circuit (PCB) with remote device suitable for 1.5/2.0 Ton split type AC for inverter model type complete all as specified and directed.
Supply and fix in repair control circuit (PCB) with remote device suitable for 1.5/2.0 Ton window type AC complete all as specified and directed.
Supply and fix in repair copper tube of size 1/2'' dia for connection of indoor and outdoor unit of split AC complete all as specified and directed.
Supply and fix in repair copper tube of size 1/4'' dia for connection of indoor and outdoor unit of split AC complete all as specified and directed.
Supply and fix in repair insulation cover of size 5/8" for insulating copper tube of split type AC all per complete all as specified and directed.
Supply and fix in repair of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC complete all as specified and directed.
Supply and fix in repair FRLSH copper cable cord flexible 3 core PVC insulated and overall PVC sheathed of size 2.5 sqmm for making connection of AC/Geysers/Water coolers/Refrigerator etc complete all as specified and as directed.
Material and labour for leak testing with nitrogen dioxide required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as specified and as directed.
Material and labour for shifting split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Reinstallation of the same to new location after necessary servicing including testing and commisioning complete all as specified and as directed.
Material and labour for shifting window type AC 1.5/2.0 TR capacity including making good the disturbed surfaces of wall/floor including making of necessary staging and wooden frame complete all as directed.
Supply only R-32 Gas for air conditioning system complete all as specified and as directed
Supply only R-22 Gas for air conditioning system complete all as specified and as directed
Supply only R-134 Gas for refrigeartion system complete all as specified and as directed
Supply and fix in repair AC support bracket of size 500x500 mm ('L' Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed.
Supply and fix in repair Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 volts capacity and tested on completion complete all as specified and directed.
Supply and fix in repair Miniature Circuit Breaker (MCB) SP 6 to 32 Amps rating 240V, 10KA 'C' Curve complete all as specified and directed.
Supply and fix in repair Miniature Circuit Breaker (MCB) SPN 32 Amps rating 240V, 10KA 'C' Curve complete all as directed.
Dismantling of 40 Ltrs cooling capacity 80Ltrs storage type water cooler of sealed compressor 1/3HP capacity by cutting of refrigerant pipe, removing sealed unit compressor and blower motor/refrigeration system, Dismantling of refrigeration system with carbon tetra chloride, replacement of the chocked capillary tubes, strainer and dryer of required size, Cleaning and lubrication of blower motor and replacement of unserviceable noshing of shaft and assembling complete including Re-assembling all the components of water cooler in proper position including charging refrigerant gas as required, Leak testing of complete refrigeration system and testing the water cooler with cooling effects after installation in original position complete all as directed. (Note : Spare parts/components as required shall be measured and paid separately under relevant items here-in-after as supply only)
All as per serial item No. 58 here-in-above but for water cooler 150 ltrs capacity of sealed compressor 1/2HP capacity.
Supply compressor 1/3 HP capacity all as specified and directed.
Supply only compressor 1/2 HP capacity all as specified and directed.
Supply and fix in repair relay with overload protector for water coolers of 40/150 ltrs capacity all as specified and directed.
Supply and fix in repair thermostatic switch for water coolers 40/150 ltrs capacity all as specified and directed.
Supply and fix in repair float valve assembly complete for water cooler 40/150 ltrs capacity water storage type all as specified and directed.
Supply and fix in repair capacitor 4 to 12 MFD of blower for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed.
Supply and fix in repair tap chromium plated suitable for water cooler complete all as specified and directed.
Supply and fix in repair blower motor of capacity 1/3 HP suitable for 40/150 ltrs capacity water cooler all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) from board/outlet boxes including fittings and fixtures such as switches, ceiling rose, regulator, socket, batten holder, conical shade and light fittings, etc. removing materials from the site and making good disturbed surfaces of walls, floors, etc. complete all as directed and as specified.
Materials and labour for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Conduit conclead with all accessories including fabricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and as directed.
All as per item serial No 69 here-in-before but One 3 pin socket outlet 5 amps on the same board with other switches
All as per item No 69 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board
All as per item serial No 69 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable for 6 pin 15 Amp socket outlet on independent board and earth continuity wire with 2.5 sqmm cable complete all as specified and as directed.
Supply and fix switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
Supply and fix socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
Supply and fix switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
Supply and fix switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
Supply and fix ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed.
Supply and fix stepped type electronic fan regulator, two module size, flush type complete all as directed.
Supply and fix lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as specified and as directed.
Supply and fixing in repair batten type LED light fitting 1x 20W, 220V,AC decorative type with internal SPD upto 4kV and overload voltage protection upto 440V including flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in repair LED light fitting 1x16/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all accessories ,complete all as specified and directed . Make :- Crompton/ Sudhir/Phillips/Bajaj/Shyaam.
Supply and fix in repair LED light fitting 2x16/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all accessories ,complete all as specified and directed . Make :- Crompton/ Sudhir/Phillips/Bajaj/Shyaam.
Material and labour for replacement of CMRI certified LED flame proof well glass Luminaires (FLP-WP)-LM6 dies cast aluminium housing with heat resistant toughed glass IP 65 protection including lamp 30 w and all accessories complete all as specified and directed .
Supply and fix in repair switch, flame proof, rotary type, with terminal box in LM6 ,10/16A single pole 250V .complete all as specified and as directed.Make Crompton/ Sudhir/Phillips/ Bajaj/Shyaam
Supply and fix in repair switch, flame proof, rotary type, Direct Entry in LM6 ,10/16A double pole 250V .complete all as specified and as directed.Make Crompton/ Sudhir/Phillips/ Bajaj/Shyaam
Material and labour for flame proof zone I&II Gas group IIA/IIB weather proof submain wiring with two runs using approved colour coding as per IS zero hologen flame retardent HFFR smoke free non toxic non corrosive PVC insulated unsheathed flexible coppper conductor cable 1.5 Sqmm single core 1100 volts and one run earth wire of 1.5 sqmm in and including ERW stove enamelled black rigid conduit of requied size but not less than 25 mmdia flame proof conduit accessories such tee bend elbow junction box including taking down complete all as specified and directed .
Supply and fix in repair flame proof zone I&II gas group IIA/IIB weather proof DB SPN 415 V 8 way with bus bar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable gland suitable for hazordous area and confirming to IS-2147/62 neoprene gasket geree of protection IP 65 suitable for MCB SPN 32 Amps-01 No MCB Sp-6-20-6 Nos complete all as specified and directed.
Supply and fixing in repair LED building security light of capacity 60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core from light fitting to ceiling rose complete all as specified and as directed.
Material and labour for GI bracket made out of 40 mm bore light grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
Material and labour for wiring with 2 runs of 1.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and type of conduit complete all as specified and directed. Note: 2 run of 1.5 Sqmm cable and 1 run of 1.5 Sqmm cable along with conduit altogether shall be measured as one unit.
Material and labour for wiring with 2 runs of 2.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia steel conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and any type of conduit and any height and structure complete all as specified and directed. Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit altogether shall be measured as one unit.
Material and labour for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.
Material and labour for Sub main wiring with 2 runs of 6.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.
Supply and fix in repair/replacement for factory made, sheet steel distribution boards, TPN, 4 Way, double door,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed
Supply fix in repair MCB DB of sheet metal enclosure double door SPN 8 way IP -43 with 200 A rated bus bar and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed
Supply fix in repair MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC(1:2:4) type B-1 (using 20 mm graded stone aggregate )omplete all as specified and directed
Supply and fix in repair MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,B-series marked fixing in DBs (DBs catered separately in this Schedule) omplete all as specified and directed
Supply and fix in repair MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,B-series marked fixing in DBs (DBs catered separately in this Schedule)
Supply and fix in repair MCB tripple pole and neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified and directed.
Supply and fix in repair for MCCBs 415 V, 16 KA, 4P, 63 Amps complete all as specified and directed
Dismantling of old unserviceable flame proof fittings for height not exceeding 20 feet for repairs/replacement complete all as specified and as directed.
Material and labour for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to GI wire 4mm dia upto 7.5 mitre by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down complete all as specified and directed.
Goswami Traders (BID ID -3348670)
M/s JK Jangid and Company (BID ID -3354713)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .