| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹13.9 L+₹4.0 L (41.0%)Rejected-Finance 1260 GANGAPUR GROUND FLOOR MANDIRTALA DUTTAPUKUR NORTH 24 PARGANAS WEST BENGAL 743248 | 24 PARAGANAS NORTH | WEST BENGAL | 743248 | L2 | Rejected-Finance Quoted higher than L1. | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically Rejected |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
22 Jun 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
University Engineer, C.U.
Office of the University Engineer Darbhanga Building, 87/1 College Street Kolkata- 700073, University of Calcutta.
NECESSARY EI REPAIRING WORKS FOR DEPT OF BIOTECHNOLOGY, BALLYGUNGE SCIENCE COLLEGE C.U.
2024_CU_689188_1
E-tender/Eng/EQ-655/23-24 (2nd call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
BALLYGUNGE SCIENCE COLLEGE CAMPUS, C.U.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹20,000
12 Nov 2024
7 Jun 2024
24 Jun 2024
7 Jun 2024
22 Jun 2024
7 Jun 2024
Amount
Distribution wiring in 2x22/0.3(1.5sq.mm) single core stranded FR PVC insulated & unsheathed copper wire in 20mm size PVC rigid conduit FR with 1x22/0.3(1.5sq mm) single core stranded "FR" PVC insulated…………..Modular type switch fixed on MOD GI switch board ....2no suitable size ph& N...original finish a) Ave run...8mtr.
Ave run 9mtr
Ave run 10mtr Switch board & vertical run both in concealed
Distribution wiring in 1.1KV grade 22/0.3(1.5sq.mm)single core stranded FR PVC insulated &unsheathed copper wire in 20mm size pvc rigid conduit FR with 1.1KV grade 1x22/0.3(1.5sq.mm)…to 6A 3pin mod type plug socket & switch on 4mod GI switch board…..building works a) On Board
Ave run 6mtr
ave run 7.5mtr
S&F 415V8way D/D Vertical TPN MCB DB for MCCB incomer with IP42/43 protection……earthing attachment 160A 8way,Legrand,L&T,Schneider incl s & F 415V four pole MCCB of breaking capacity 35KA with fixed thermal &fixed magnetic setting in existing DBs with necy connection 160A,Legrand,Schneider,L&T one no & TP MCB63A for outgoing 8 nos c characteristice breaking 10KA
S&F D/D horizontal TPN MCB DB with IP42/43…with neutral link & provision for earthing attachment 8way,Legrand,Schneider,L& T incl S & F240/ 415V MCB isolator on DIN rail of existing DBs & necy connection 100A FP,Legrand,Schneider,L&T as incomer &Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection SP 6-32Amps Legrand 24nos
S&F D/D horizontal SPN MCB DB with IP42/43…with neutral link & provision for earthing attachment 2+12way,Legrand,Schneider,L& T incl S & F240/ 415V MCB isolator on DIN rail of existing DBs & necy connection 63A DP,Legrand,Schneider,L&T as incomer &Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection SP 6-32Amps Legrand as outgoing 12 nos
supplying & Layingof PVc Arm.cable as below on existing cable tray & binding with suitable GI wire…AL.conductors 1.1 kv grade conforms to IS:1554(part 1)for following cross section incl S& F compression type gland with brass gland,brass ring,rubber ring for dust & moisture proof entry &Finishing the end of the following cable end by crimping method incl S & F dowels etc.a)1x50sq.mm 3.5C incl
1x 16sq.mm 2C
Supplying & Fixing only Twin flurescent light fitting suspended 25cm below the ceiling with 2no 20mm dia EI conduit supports fixed with "L" type MS clamp whose one side fixed on ceiling….1.10mtr length of luminaires which are as follows….. TMC 501 P 2xT-LED incl.mounting rail for TLED lamps & TLED Essential tube 1200mm..1600 Lumen 20w(Philips)(Philips/Havells/C&G) 2nos for each ser
Supplying & Fixing only single fluorescent light fitting complete with all accessories directly on wall… suitable size fastner..as required of luminaires which are as follows….. TMC 501 P 1xT-LED incl.mounting rail for TLED lamps incl Essential tube 1200mm..1600 Lumen 20w(Philips)(Philips/Havells/C&G) 1no for each ser(Philips/Havells/C&G)
S&F 240V ,16A 3pin mod type plug socket with 16A mod type switch without plug top on 4 mod GI mod type switch board…..continuity wire etc
S&F 240V , 3nos16A 3pin mod type plug socket with 3nos 16A mod type switch 20A mod switch type SP MCB & indicator without plug top on 2row 12 mod GI mod type switch board…..continuity wire etc
S&F240V 4nos 6A 3pin mod type plug socket with 4nos6A mod type switch,16A mod switch type MCB…2row 18 mod top cover…..continuity wire etc
S&F240V modular socket type(2mod) fan regulator(step) on existing mod GI switch board..connections etc
S& F 12" (300mm) sweep,1420 RPM exhaust fan(Make: EPC heavy duty, after making hole in wall & mending good damages & smooth cement finish …withnecy bolts & nuts(6mm dia x62mm long)
Supply & fixing after lowering the existing ceiling fan incl blade etc with necy disconnection of power supplyof ceiling fan 1200 mm(48") IS 374:2019 withBLDCmotor,minimum air delivery 210m3/min 3star BEE rating with service value >4.1 to<5.1,orient quasar,Havells,CG or equivalent
Disrtibution wiring in 1.1KV single core stranded FR PVC insulated & unsheathed copper wire in 20mm size PVC rigid conduit FR…as required 2x22/0.3(1.5sq.mm)+ 1x22/0.3(1.5sq.mm) ECC
2x36/0.3(2.5sq.mm)+ 1x22/0.3(1.5sq mm)ECC
2x56/0.3(4sq.mm)+1x36/0.3(2.5sq.mm)ECC
2x84/0.3(6sq.mm)+1x56/0.3(4sqmm) ECC
S&F 240V,25A mod type socket,25A mod type starter with 25A mod switch type DP MCB &6 mod GI….earth continuity wire etc
S & F earth busbar of galvanized MS flat of 25x6 mm on wall having clearence of 6mm incl providing of drilled holes…….as required inclconnecting the equipment to earth busbar incl S& F GI wire of size as below on wall staples inside wall as reqd & making connection with equipments with nut bolts etc & mending good damages. 10SWG
S D ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .