Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.6 L+₹4.8 L (14.5%)Rejected-Finance | L2 | Rejected-Finance Second lowest bidder | |
| 3 | L3₹38.5 L+₹5.6 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Third lowest bidder | |
| 4 | L4₹40.2 L+₹7.3 L (22.2%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest bidder |
Tender Value
₹38.9 L
EMD Value
₹77,800
Closing Date
10 Jul 2024, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
PROVN OF STAND BY POWER SUPPLY TO PUMP HOUSE NO 06, PROVN OF EMERGENCY EXIT/ENTRY EXIT, PROVN OF RING MAIN SYSTEM FOR WATER SUPPLYAND PROVN OF AIR CONDITIONERS (04 REVENUE WORKS) AT ATS BELAGAVI
2024_MES_659261_1
GE(AF)/SAM/TOK-19 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE AF Sambra
₹77,800
Yes
5 Sept 2024
12 Jun 2024
12 Jul 2024
12 Jun 2024
10 Jul 2024
28 Jun 2024
Amount
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc. and getting out in hard/dense soil complete all as specified and directed.
M&L for plain cement concrete in foundations, filling and mass concrete using 1:4:8 nominal mix type D-2 (using 40mm graded crushed stone aggregates) complete all as specified and directed.
M&L for 10mm dia and over TMT bar cut to length bent to shape required, including cranking, bending spiarlly for hooping for colums, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for 5mm dia and over upto 10mm dia TMT bar cut to length bent to shape required, including cranking, bending spiarlly for hooping for colums, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips for stirrups, spacers and binders complete all as specified and directed.
M&L for RCC in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete using M-20 Design Mix (using 20mm graded crushed stone aggregates) complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished surface of concrete of flat surface complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete of flat surface in square or rectangular shape complete all as specified and directed.
M&L for RCC in column using M-20 Design Mix (using 20mm graded crushed stone aggregates) complete all as specified and directed.
M&L for pre cast cement concrete block masonary in type C1 , 1:3:6 (using 20mm graded crushed stone aggregates) with solid blocks exc 10cm in width and setting in cement mortar 1:4 straight or curved on plan exceeding 6 m mean radius built in CM 1:4 complete all as specified and directed.
M&L for RCC in roof supported on wall, beam using M-20 Design Mix (using 20mm graded crushed stone aggregates) complete all as specified and directed.
M&L for RCC in roof beam supported on wall, column using M-20 Design Mix (using 20mm graded crushed stone aggregates) complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc in rough finished surface of concrete of flat surface complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:3 on faces of brick or concrete surfaces of ceiling soffit and finishing the surface even and smooth surafce without using extra cement complete all as specified and directed.
M&L for plastering 15mm thick in CM 1:6 on faces of brick or concrete surfaces of wall and finishing the surface even and smooth surafce without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on faces of brick or concrete surfaces of walls and finishing the surface even and smooth surafce without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:3 on unfair faces of brick or concrete surfaces of RCC roof top and finishing the surface even and smooth surafce without using extra cement mixed with water proofing compound complete all as specified and directed. Note:-Water proofing compound shall be measured and paid separately
Supply only intergral water proofing compound as per IS: 2645 complete all as specified and directed.
M&L for preparation of undecorated plastered surface of walls and applying two coats of oil bound distemper over one coat of primer over 2mm thick wall care putty complete all as specified and directed.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including 2mm thick wall care putty complete in all respect as specified & directed.
M&L for preparing, washing, rubbing down and complete removal of existing treatment for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces including 2mm thick wall care putty complete in all respect as specified & directed.
M&L for preparation of undecorated plastered surface of ceiling surface and applying two coats of oil bound distemper over one coat of primer over 3mm thick wall care putty over ceiling surface in two coats complete all as specified and directed.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new ceiling surfaces over 3mm thick wall care putty in two coats complete all as specified and directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, sub base to floor or similar items and finished surface even and smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling of brickwork, concrete masony work or stone/boulder masonry work, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floor and pavings not exceeding 15 cm thick (below or above ground level) and removing all the rubbish complete all as specified and directed
M&L for plain cement concrete 1:2:4 type-B2 (using 40 mm graded crushed stone aggregates) as in foundation and filling in mass concrete complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) as in 100mm thick hard standing or paving etc and spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in 75mm thick sub base to floor or similar items surface finished even and fair complete all as specified and as directed.
S&F framed work as in doors or gates of angles, tubes, flats or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running, rails and guiedes) and hanging; also fastening and fixing complete conforming to Fe-290 (Gde E 165) complete all as specified and as directed.
S&F framed work such as grills fancy type, gratings, etc with ends of bars shouldered and revited or forged into spikes,framed guard bars barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks, false ceilings, and similar work. Fe 290 Gde E-165 for portions framed and hung as gates, including wheels, pintle hinges, stops, hand made sliding bolts , hot rolled spikes etc. complete all as specified & directed
S&F Joist, channel, angle, or tee, flat etc., sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) and similar work. Fe 290 Gde E-165 complete all as specified & directed
S&F reinforced concrete pipes, class NP2, 450mm dia, laid and jointed with collars complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum getting out in hard/dense soil, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm width and girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Taking down cement plaster from concrete celing surfaces incl racking out joints hacking for key, scrubbing down with water etc complete including removing rubbish off the premises all as specified and as directed.
Restraining, resecuring of barbed wire fencing including making good staples securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. including fixing of existining concerntina coil as directed to any type complete all as specified & directed.
S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying of existing concertina coil with and provision of galvanised mild steel wire, staples or steel pins etc. complete all as specified & directed.
S&F concertina coil fencing, punched tape, coil 450mm dia having 7 to 8 nos rounds per 1 metre length, fixing on angle iron 'Y' shaped & placed over perimeter wall with GI staples and GI clips to retain horizontal including necessary bolts or GI barbered wire tied to angle iron, etc complete all as specified and directed.
M&L for for coloured glazed ceramic tiles joint less/edge cutted of size 450mmx300mmx6mm to 7mm thick as in vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 15mm thick backing/rendering in cement mortar (1:4) complete all as specified and directed. Note:- Those tiles fixed right angled to each other, the each tile should be chamfered/trim/sharp at 45 degrees at joint/corner/edge, the quoted rates are inclusive for this provn.
S&F 1.25mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S&F stainless steel (Grade 304) composite sections of hollow pipe/tube, flat, plates, angle section, fancy pipe top caps etc. of for sign board, display board welded with stainless steel rod, of any size, shape, description including welding, grinding, buffing, polishing and making curvature (wherever required) to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed.
M&L for 3mm thick aluminium composite exterior grade plain panel sheet of approved colour, size, shape, for sign board including necessary stainless steel nut bolts complete all as specified and directed. Make 3M or equivalent make as approved by GE
S&F 1mm thick radium based, hexagonal pattern retro reflective self adhesive plastic sticker sheet of approved colour as per size, design, pasted over board/ aluminium composite panel exterior grade sheet complete all as specified and directed.
S&F 1mm thick radium based, hexagonal pattern retro reflective self adhesive plastic sticker sheet of approved colour, size and any quantity, design, pasted over board/ aluminium composite panel exterior grade sheet including laser cutted figures such as direction signs, photoes, words and alphabets etc., complete all as specified and directed.
M&L for point wiring for one light/exhaust fan/fan point controlled by one switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable confirming to IS drawn through and including non metallic PVC conduit concealed/semi concealed including flush type metal GI boxes for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm. copper conductor as earth wire connected to common earth dolly and earth in distribution board including cutting of stone masonary/ wall complete all as specified and directed
All as per Srl item No.47 above but for one 5 Amps socket on independent board
S&F switch modular type single pole 6 Amps One Way AC 230V, 50HZ complete all as specified and directed
S&F celing rose surface backlite 63 mm dia two to three terminals complete all as specified and directed
S&F modular type socket 5A AC 230V, 50HZ complete all as specified and directed
S&F modular white cover plate with frame 2 module complete all as specified and directed
S& F modular white cover plate with frame 3 module complete all as specified and directed
M&L for sub main wiring with 2runs of 2.5 Sqmm PVC insulated FRLS Copper conductor cable including PVC conduit of Suitable along with one run of 2.5 Sq.mm FRLS copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly complete all as specified and directed
M&L for sub main wiring two single core PVC insulated cables with FRLS copper conductor 1100 Volts grade, 4 Sqmm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed up walls, roofs, or floors including one run of 4 Sqmm PVC insulated cable earthing wire and connecting up complete all as specified and directed. Note:- 3 runs of 4 sqmm cable and one run of PVC conduit / casing & capping will be measured as one unit length.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S&F post top lantern LED type 20 watt 230V AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed
S&F LED flood light 70 watts, 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed
S&F SPN DB 8 Way with 200 amps rated bus bar double door complete all as specified and directed
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN and current carrying capacity 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed
M&L for for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dia and frame all as shown in electric plate No 3 in page 497 of MES SSR Part I (2009) including testing complete all as specified and directed
Supplying and installing hi wall split units indoor/outdoor wall mounted splint AC unit star rated complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR including necessary bracket (where ever required) complete all as specified and directed. Make:-BLUE STAR, HITACHI, LG, VOLTAS, CARRIER
S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed. Make:-V Guard, Microtek
M&L for sub main wiring two single core PVC insulated cables with FRLS copper conductor 1100 Volts grade, 10 Sqmm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed up walls, roofs, or floors including one run of 10 Sqmm PVC insulated cable earthing wire and connecting up complete all as specified and directed. Note:- 3 runs of 10 Sqmm cable and one run of PVC conduit / casing & capping will be measured as one unit length.
S&F distribution board,double door, 4 way, SPN with 200 Amps rated bus bar 240 Volts including taking down old unserviceable DB complete all as specified and directed.
S&F MCB Single pole, 240 volts 6 to 32 Amps, 10 KA rupturing capacity, 'C' curve including taking down unserviceable MCB complete all as specified and directed.
S&F MCB Single pole & neutral 240 volts 40 to 63 Amps, 10KA rupturing capacity 'C' curve complete all as specified and directed.
S&F single pole and neutral enclosure with two pin and earth plug and socket with 20 amps MCB SP complete all as specified and directed.
Returning and filling in soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for cutting /breaking of cement concrete path or bituminous road of any thickness with or without reinforcement for taking up/down of DI/GI/CI pipes and connection and making good to match existing surface by PCC (1:2:4) type B1 (Using 20 mm graded stone aggregates) complete all as specified as directed.
Supplying, laying and testing 150mm nominal bore ductile iron pipe , spigot and socket including Rubber joints class K-7 complete all as specified and as directed. Note :- Specials and fittings will be measured and paid separately.
Supplying, laying and testing MS pipe 150mm bore including MS Flange (heavy duty) including rubber gasket packing suitable nuts, bolts, washers all fittings like brackets of any angle, short pieces, welding the flanges to MS pipe complete, applying two coats with black paint over one coat of red oxide primer externally on the pipe line complete all as specified as directed.
S&F cast iron / Mild steel fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) color, caps and plugs suitable for DI/CI pipe upto 150 mm dia complete all as specified and as directed.
M&L for construction of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolishing old valve pit complete all as specified and directed
S&F cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc including dismantling of existing unserviceable one for the 150 mm dia Pipe complete all as specified and directed
Supply, install, testing and commissioning of acoustic proof diesel engine driven generating set, fully wired, 415 Volts, AC, 3 phase 4 wire, 50Hz having capacity 24KW/30 KVA CPCB IV Norms continous rating at power factor 0.8 (lagging) as per IS-4722 and connections as per IE rules complete with liquid cooled 4 stroke Diesel engine with electric start with 12V DC battery, developing minimum 42 BHP at 1500 RPM under NTP prevailing at Sambra area, Belagavi considering derating factor and shall conform to IS:10000/150 3026/BS-5514 with provisions of 10% over loading for 1 hour for every 12 hours running with A1 class governing and all standard safety type, screen protected, revolving field, self excited, self regulated alternator conforming to BSEN-60034 with IP 23 protection complete with integrated AMF control panel with microprocessor based relays/MCCB/MCB's/Contactors, multifunction meter showing KWH, KVA, PF, Amps, Volts, frequency, indicating lamps, 12 Volt battery charging unit including 12 Volts battery etc required asper latest standard engineering practices including sound proof canopy designed to meet MoEF/CPCB Norms of 75 dBA at 1mtr at 75% load, fabricated from CRCA sheet and a structural/sheet metal base frame, with high quality noise absorbent and fire retardant grade acoustic insulation material conformity to IS : 8183 and integrated fuel tank of capacity not less than minimum 8 hrs running fuel filling arrangement from inside duly painted after necessary pre treatment process complete all as specified and as directed. Make : Cummins / Kirloskar / Greaves Cotton / Ashok Leyland Make of Alternator: Stamford (CGT)/ Kirloskar / Crompton Greaves Note: (i) The cost of PCC foundation as per the recommendation of OEM shall be deemed to be included in the quoted rate. (ii) Cost of fuel and other expenses for carrying out acceptance test of the DG set shall deemed to be included with the quoted rate.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 50 Sqmm 3.5 core aluminum conductor 1100volts grade underground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Supply and install ON LOAD change over switch 415 Volt in sheet metal enclosure type 4 pole of capacity 63 Amps (suitable for open execution and to be fitted in the standard control panel or as per site requirement) complete all as specified and directed
Supply , install, testing and commissioning of LT feeder pillar box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 40X40X3 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified
BUSBAR :- copper bus bar 200 Amps, 415 Volt , supported on non hygroscopic fibres, studs and brass screws for mounting -04 Nos
INCOMING: MCCB of 4 pole of capacity 63 amps with breaking capacity of 10 KA adjustable thermal and magnetic setting - 01 No.
INDICATING DEVICES: (a) LED Indicating lamps for Main Supply indicating R, Y, B -- set of 3 (b) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator -- 03 Nos
OUTGOING FEEDERS: (a) MCCB of 4 pole of capacity 63 amps with breaking capacity of 10 KA adjustable thermal and magnetic setting - 01 No. (b) Compartment for 63 Amp Change Over Switch
S&F DWC pipe IS-16205, size inner dia 50 mm, outer dia 63 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and directed
M&L for earthing complete with galvanized steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not le. than 1.5 m below normal ground level connected to Galvanized Strip 32mmx6mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 15 mm dia light grade pipe for protection of earth electrode 20 mm dia funnel for watering all as specified and directed and tested on completion.( LT Panel ) complete all as specified and directed
M&L for earthing complete with Copper earth plate electrode 600mmx600mmmx3.15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not le. than 1.5 m below normal ground level connected to Copper Strip 20mmx3mm by means of bolts and nuts checknuts and washers of copper all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 15 mm dia light grade Pipe for protection of earth electrode 20 mm dia funnel for watering all as specified and directed and tested on completion.(For DG SET) cmplete all as specified and directed
RAJENDRA KRISHNA SARAF
M/s. VIJAY ELECTRICALS
ASHIRWAD ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .