| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC VILL JAMALPUR P O NAYA MAHMMADPUR DISTT BHOJPUR ARA PIN 802163 | ARA | BHOJPUR | BIHAR | 802163 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹41.0 L+₹97,814.50 (2.45%)Rejected-Finance HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹41.2 L+₹1.2 L (2.97%)Rejected-Finance MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹41.4 L+₹1.4 L (3.46%)Rejected-Finance W D BUILDING JP ROAD BHARALUMUKH GUWAHATI 781009 ASSAM | KAMRUP METRO | ASSAM | 781009 | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹41.8 L+₹1.8 L (4.42%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
31 Aug 2021, 6:00 pmClosed
GE NARANGI
GE Narangi C/O 99 APO Guwahati
COMPREHENSIVE REPAIR TO MD ACCN OF JCO OR REPAIR REPLACEMENT OF AC ROOF CEILINGS IN VARIOUS MD ACCN INCLUDING REPAIRS TO INTERNAL ELECTRIFICATION AND ALLIED WORKS IN PH II AREA UNDER GE NARANGI.
2021_MES_465254_1
8672/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE NARANGI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NARANGI
₹99,000
Yes
27 Oct 2021
4 Aug 2021
3 Sept 2021
4 Aug 2021
31 Aug 2021
18 Aug 2021
Amount
Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed.
M&LPre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed.
M&LPre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and directed. Note: To be executed for provision of ridges valley and hips.
S&F in repairs, suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner shall not be placed at more than 450mm from the adjacent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M & L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250) for fixing complete all as specified and as directed.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC 1:5:10 type E2 (using 40mm graded stone aggregate) as in filling/mass concrete in sunken floor complete all as specified and directed.
S&F GI water tubing 40 mm bore, medium grade with all fittings and fixed complete laid on floors as in spout pipe complete all as specified and as directed.
Demolition of plain cement concrete (Un-reinforced) in ground floors and paving n exc 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M & L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in back filling in pressed steel door and window frame complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4, type B0 (12.5 mm graded stone aggregate) as in floors finished the concrete surface even and smooth with using extra cement and pigment complete all as specified and as directed. Note : This item shall not be operated as sub base for floor tiles.
Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as "Supply only".
M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 5mm thick in cement mortar (1:3) on fair faces of RCC concrete surfaces and including applying cement slurry in bottom of slab, chajjas, fin, facias etc. complete all as specified and as directed.
M & L for rendering 15 mm thick, in cement mortar 1:4 on roof top or suken floors using water proofing compound at the rate of 3% weight of cement as per manufacturer instructions complete all as specified and as directed.
M & L for applying two coats of epoxy resin / polymer modified cementitious coating like brush bond of FOSROC or equivalent to wall, beams and floors of sunken portion complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish not exceeding 100 mtr distance from starting point. (ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 with mixing of WPC and surface finished fare and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm.
Supply only Integral water proofing compound ISI marked complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer including a coat of 1.00 mm (average) thick wall care putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for complete removal of old treated surfaces on walls and applying one coat of alkali resistant primer including a coat of 1.00 mm (average) thick wall care putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of weather proof paint complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M & L for preparation of old plastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.
Dismantling timber scantling 40Sqcm and over in section as in unframed work in any position complete all as specified and as directed.
M&L for 2nd class hard wood, in scantlings, clean sawn timber as in unframed work complete all as specified and as directed.
M & L for preparation of surfaces of wood and wood based surfaces new or old of any description and girth not otherwise described and treating with two coats of creosote oil complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each including builders hardware complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware complete all as specified and as directed.
M&L for 1.25mm thick factory made pressed steel frames of size 125x60mm for doors with single rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M&L for 1.25mm thick factory made pressed steel frames of size 105x60mm for doors with single rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
S & F 35 mm thick flush shutter, solid core construction with particle board core and plywood face panels, commercial type on both side complete all as specified and as directed.
S & F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (with out sash bar), edges of framing with plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and as directed.
S&F in repairs, 20 mm thick 2nd class hard wood boarding clean sawn, planed one side with butt joints and fixed with nails in any situation as in eaves board, etc. complete as specified and as directed.
M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood or wood based materials of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and as directed.
S & F factory made solid PVC door frame of size 40mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S & F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specfication, drawing and complete all as specified and as directed.
S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed.
S & F 200 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed..
S & F 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed.
S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F in repairs, stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F in repairs, mild steel PVC coated coloured 25 mm dia drapery rods for curtains including decorative end holders and brackets (wall to wall or flush to wall) for securing curtain rod,complete all as specified and as directed.
S & F box type steel windows with side hung shutters both mosquito proof and glazed shutter including projecting type hinges with steel handle and steel peg stay with glazing bars and 12 mm square bar or ground bar of approved design welded to steel window frame dovetailed or welded complete all as specified and as directed.
S&F steel ventilators with top hung shutter including hinges, steel peg stay complete including making good disturbed portion in PCC (1:2:4) type B-1 complete all as specified and as directed.
M & L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Hacking out old broken glass (any thickness, quality or description) from wooden/steel frame or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed.
S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares in exc 0.5 sq.m in each pane complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing complete all as specified and directed.
M & L for coloured Non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M & L for coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 15 mm thick screed bed or bedding layers in 15mm thick screed bed in cement motar 1:4 complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular )area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M & L for glazed ceramic coloured tiles 375x250x7mm/300x200x7mm thick, set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
S & F in repairs, 20mm bore, gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repairs, bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs, stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe.
S&F in repair, 15mm bore dia of conceled stop valves cast copper alloy fancy type chromium plated with long shank and cup complete all as specified and as directed.
S & F in repairs, 125 mm, dia chromium plated, swivel type shower rose with 190 mm long chromium plated shower arm and wall flange suitable for fixing 15 mm bore iron pipe complete all as specified and as directed.
S&F in repair, tubular towel Rail of 20mm dia and 60cm in length, D shaped, with brass chromium plated brackets complete all as specified and as directed.
S&F in repairs, soap dish chromium plated fixed to wall with chromium plated brass screws and plastic cleats complete all as specified and as directed.
S&F in repairs, Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and as directed.
S & F in repairs, sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortat to dwarf wall or including fixing cantiliver brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 405 mm x 355 mm x 178 mm complete all as specified and as directed.
S & F in repairs, kitchen plate rack made of stainless steel sheet not less than 0.63 mm thick of over all size 600 mm x 900 mm x 250 mm complete all as specified and as directed. Make : Prayag Cat No P-336 or Silver Shine Cat No-SSKPR-312 or equivalent make and model of Suyog
S & F in repairs, 10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets etc complete all as specified and as directed.
S & F in repairs, PVC connections 15mm dia with PTMT nuts of length 450mm complete all as specified and as directed.
S & F in repairs, vitreous china, wash hand basin, white, flat back size 550 mm x 400 mm including brackets including pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe,15mm dia PVC connection pipe complete all as specified and as directed
S & F in repairs, Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed.
S & F in repairs, 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed. Note : Excavtion & Earth work is deemed to be include in quoted rate.
S & F in repairs, 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S & F in repairs, 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed. Note : Excavtion & Earth work is deemed to be include in quoted rate.
S & F in repairs, 75mm bore PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S & F 110 mm dia PVC (SWR) bends of any radius complete all as specified and as directed
S&F 75 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed
S&F 110mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed.
S&F 75mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed.
S & F in repairs, PVC (SWR) nahani trap with grating 75 mm outlet dia, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repair 110mm bore PVC (SWR) vent cowl complete all as specified and as directed.
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 90 here-in-before but for One light point controlled by 2- two way 5 Amps switch
All as per item serial No 90 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board
All as per item serial No 90 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item serial No 90 here-in-before but for One bell point controlled by one switch 5 Amps bell push.
All as per item serial No 90 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC rigid conduit on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 96 here-in-before but for One light point controlled by 2- two way 5 Amps switch
All as per item serial No 96 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 96 here-in-before but for One 3 pin 5 Amp switch socket outlet on same board with other switches.
All as per item serial No 96 here-in-before but for One bell point controlled by one switch 5 Amps bell push.
All as per item serial No 96 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, modular switch , flush type single pole one way 6 Amps 240 volt complete all as specified and as directed.
S&F in repairs, modular switch , flush type single pole one way 16 Amps 240 volt complete all as specified and as directed.
S & F switch piano, flush type single pole two way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, switch piano, flush type single pole two way 5 Amps 230 volt complete all as specified and as directed.
S&F bell push, flush type, 5 Amps complete all as specified and as directed.
S&F in repairs, bell push, flush type, 5 Amps complete all as specified and as directed.
S & F in repairs, modular Bell push 6 Amp 240 volts, flush type complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and as directed.
S&F in repairs, socket outlet 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and as directed.
S&F in repairs, modular Socket outlet 2 in 1, 3 Pin 6 Amp flush type 240 volts complete all as specified and as directed.
S&F in repairs, socket outlet 3 Pin 15 Amp 240 volts complete all as specified and as directed.
S&F in repairs, modular Socket outlet 2 in 1, 3 Pin 6 Amp/16Amp flush type 240 volts complete all as specified and as directed.
S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
S&F in repairs, ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
S & F lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S&F in repairs, lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S & F stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
S&F in repairs, stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
S&F in repairs, modular stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
S & F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
S&F in repairs, call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
S&F in repairs, white cover plate with frame ,1 module complete all as specified and as directed.
S&F in repairs, white cover plate with frame ,3 module complete all as specified and as directed.
Dressing of pre-wired casing caping /PVC conduit of One light /fan/ exhaust fan point controlled by one number one way 5 Amp switch by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit , screws etc) complete all as specified and directed.
Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6 inch x 10 inch MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper multistranded cable complete all as specified and as directed. (Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items).
All as per item No132 here-in-above but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 8 inch MS box.
S&F in repairs, LED box type fitting of regal batten pre-wired including LED tube 1x20W ,fixed on PVC block connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed. Make:- Havells Model-REGALBATTENT8UPTO1X22WDSBSWH +CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Philips /GE/Crompton
S&F in repairs LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no of PVC block complete all as directed. Make:- Jaguar Model-LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XW or Make:- Havells Model-LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Cromptonor
S&F in repairs LED (double sided connection) ) ultra bright polycarbonate tube light 18/20 watt retrofit in existing flourescent tube light . Make Havells/crompton/Bajaj/Jaquar or euivalent.
S&F in repairs wall mounted decorative luminaire in design mesh suitable for 9W LED lamp B22 base ,including lamp 15watt complete all as specified and as directed. Make -Havells, cat no-LHDL07150099 or equivalent in crompton, Bajaj, Jaquar
S&F in repairs Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- Havells Model HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips / Crompton /GE.
S&F in repairs LED building security luminaries 35 Watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completion complete all as specified and as directed. Make: Havells CAT No. ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC or equivalent of Philips/Wipro/CG
M&L for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, and transporting to MES E/M store yard, and refixing on same location or other location complete all as specified and as directed.( Cost of repairing including replacement of spares if any will be measured and paiid seperately under relevent items of this schedule.
Strip opening of ceiling fan 1200 /1400 mm sweep, cleaning thoroughly bush & ball bearing by petrol, washing/cleaning fan blades with caustic soda thoroughly, provision of fresh greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge. Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Cutting the existing copper winding of AC ceiling fan 1200 mm//1400mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 metres long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only condenser ISI marked 230/240/250 volts AC 2.5 Mfd suitable for ceiling fan. (Make : Usha/Asian/EPCOS/Universal).
Supply only ball bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI
Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and as directed.
Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and as directed.
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed.
Taking down exhaust fan of size 200mm to 300mm sweep of any make and transporting from any location to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed. Note:- Cutting the existing copper winding, rewinding, Replacement of defective/ unserviceable parts if required shall be measured and paid separately under respective items .
Cutting the existing copper winding of AC exhaust fan 200mm to 300mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials incl varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only ball bearing suitable for exhaust fan upto 300 mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI
Supply only condenser ISI marked 230/240/250 volts AC 4.0 Mfd suitable for exhaust Fans complete all as specified and as directed. (Make : Usha/Asian/EPCOS/Universal).
M & L for painting of ceiling/exhaust fan complete with blades ,in situ with synthetic enamel paint Duco by spraying including filling cavities with filler ,ones coat after cleaning all dust etc.complete all as specified and as directed.
S&F in repairs, ventilating fans AC single phase 230/ 240 V of size 250 mm sweep with louver shutter with frame and necessary fixing accessories , writing MES No. with black synthetic enamel paint 2 cm high in letter complete with necessary connection up including provision of three core copper flexible cable with flexible wire cover of plastic white in colour and connection from ceiling rose to exhaust fan terminal etc complete all as specified and as directed. Make-Usha, Model-CRISP AIR LX EXHAUST FAN or equivalent make in Crompton, Bajaj Note: Old fan shall be deposit to E/M yard.
S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
S&F in repairs, MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.)
M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
Taking down carefully by unscrewing from board/outlet boxes, fitting and fixturessuch as switches, sockets,ceiling rose, lamp holders, brackets ceiling fitting ,bulkhead fitting, tube light fitting and regulator etc for reuse at site or carring to the store ( To be measured only when found in all respect complete for reuse) and making good disturbed surface of wall, flooretc complete all as directed by Engineer-in-Charge.
Refixing serviceable fittings/ fixtures as obtained from serial item no 160 here in before and connecting up with suitable size cable in location as directed by the Eng In charge .
S&F in repair telephonic wire used in home unit for smart meter ,4 wire RJ11 complete all as specified and as directed.
S & F in repairs, SMC Mild steel (Deep Drawn & Fabrication ) Polycarbonate meter box of suitable size accommodate 4 nos of three phase meter per box ,anticorrosive ,dust proof,rust proof ,shock proof self extinguishing property .resistance to heat,vermin & water proof ,ultra voilet stabilized and pilfer resistance including push fit locking system conforming to SMC materials ,IS: 14772 complete all as specified and as directed. Make -RMC/Sintex
Disconnecting the main power supply to distribution box and make a proper dressing of SPN/TPN/VTPN MCB/MCCB DBs of pre-connected MCBs by changing screw of DB cover ,earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box and duly connecting up complete all as specified and directed.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including demolition of old earthing complete all as specified and directed..
LAXMI CONSTRUCTION
M/S Bharat Construction
PK ENGINEERING
M/S MANOJ PAUL
M/s DAS AND CO
M/S SR BUILDERS
KAMAKHYA CONSTRUCTION & BUILDERS
M/s KRISHNA CONSTRUCTIONS
M/s Dhani Enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .